복수의 TMD를 이용한 고층건물의 진동조절 (Vibration Control of Tall Buildings using Multiple Tuned Mass Dampers)

  • 민경원;홍성목
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1992년도 봄 학술발표회 논문집
    • /
    • pp.26-29
    • /
    • 1992
  • Modern tall buildings are subject to wind induced oscillations. Those oscillations can cause discomfort to the occupants. To control these motions, tuned mass dampers have been used. In this paper, component node synthesis, based on Lagrange multipliers formulation. is applied to the along-wind motion of tall buildings with multiple tuned mass dampers. Spectral densities of accelerations of top floor are compared by changing the numbers and locations of tuned mass dampers. It is found that multiple tuned mass dampers can be more effective than single tuned mass damper in reducing the acceleration response.

  • PDF

110Watt 4등용 형광등 안정기 개발 (Development of Electronic Ballast for 110Watt lamps)

  • 한재현;조계현;박종연
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 하계종합학술대회 논문집 V
    • /
    • pp.2927-2930
    • /
    • 2003
  • This paper has been studied the ballast for multiple lamps. Many fluorescent lamps are demanded in where industrial buildings and public buildings. Using the proposed ballast for multiple lamps, we can decrease the cost and the space for installing. Also in the paper, the protection circuit is introduced for over voltage and current. The general problem of the ballast for multiple lamps is to shut down the ballast circuit in the ease of one abnormal lamp. But the proposed method is not shut down all the circuit even if one lamp is in an abnormal condition.

  • PDF

다중이용업소의 화재사례 분석을 통한 안전관리 개선방안 연구 (A Study on Ways to Improve Safety Management through Analysis of Fire Cases in Multiple-user Buildings)

  • 이재욱
    • 문화기술의 융합
    • /
    • 제8권3호
    • /
    • pp.191-201
    • /
    • 2022
  • 본 연구에서는 다중이용업소의 안전관리에 대한 법적 운영실태 분석과 다중이용업소에서 발생한 대형화재 사례분석 등을 통하여 다중이용업소 화재 및 안전관리에 대한 문제점을 도출하고 재발 방지를 위한 개선책을 제시하고자 한다. 연구를 위하여 먼저 다중이용업의 이론적 고찰을 통하여 업종의 현황과 화재 발생 현황 등을 조사한 후 다중이용업에 대한 선행연구 분석을 하였다. 그리고 법적·제도적 현황을 분석하여 충청북도 제천 화재, 인천 인현동 화재, 서울 송파구 화재 등의 사례를 통하여 문제점을 도출하였다. 그 결과, 첫째, 화재 초기대응 능력 강화의 필요성. 둘째, 비상구 유지·관리의 철저. 셋째, 실내 장식물의 합리적인 규제의 필요성. 넷째, 소방안전 교육·훈련의 강화. 다섯째, 소방 및 안전시설 등의 설치 기준 강화. 여섯째, 안전관리에 대한 경각심의 고취가 필요하다는 결과를 도출하고 법·제도적 내용과 비교·분석하여 이에 따른 해결방안을 제시한다. 다중이용업소 화재의 원인을 보면 건물주, 영업주, 종사자들이 자기 영업장에서 화재가 발생할 리가 없다는 생각을 가져 경각심이 부족하다. 소방관서와 관련 행정기관의 교육과 홍보를 통하여 경각심을 고취시켜야 할 것이다.

건물유형 및 지역조건에 따른 ECO2 및 TRNSYS의 냉난방부하 비교분석 (Comparison Analysis of Cooling and Heating Demand by Building Type and Region using ECO2 and TRNSYS)

  • 박동진;이현재;오진환;권영식;양재광;남유진
    • 한국지열·수열에너지학회논문집
    • /
    • 제19권4호
    • /
    • pp.1-7
    • /
    • 2023
  • In Korea, it is also mandatory for most buildings to receive energy efficiency rating certification from 2020 for the purpose of reducing greenhouse gas emissions and expanding green buildings. However, the issue of the accuracy of the ECO2 program continues to be raised, and comparisons have been made with dynamic energy analysis programs in a single type of building according to a single area. However, comparisons between multiple building types and multiple areas are insufficient. Therefore, in this study, cooling and heating loads according to multiple building types and multiple areas were analyzed through ECO2 and TRNSYS programs. The regions were supposed to be Seoul, Daejeon, Gwangju, and Busan and the building types were supposed to be office buildings and apartment houses. The annual average building load values from ECO2 were higher than those from TRNSYS. Among residential buildings across the four regions, the largest discrepancy was 41.4% in Seoul. Conversely, for commercial buildings, the most significant difference in annual average loads was noted in Gwangju, at 37.9%.

Development of Load Prediction Equations of Office Buildings

  • Seok, Ho-Tae;Kim, Kwang-Woo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제10권2호
    • /
    • pp.65-71
    • /
    • 2002
  • The objective of this study is to evaluate the design parameters and to develop the cooling and heating load prediction equations of office buildings. The building load calculation simulation was carried out using the DOE-2.1E program. The results of the simulation were used as data for multiple regression analysis which could develop the load prediction equations.

사무소 건설의 설계변수 열성능 평가 및 부하예측방정식 개발 (Thermal Performance Evaluation of Design Parameters and Development of Load Prediction Equations of Office Buildings)

  • 석호태;김광우
    • 설비공학논문집
    • /
    • 제13권9호
    • /
    • pp.914-921
    • /
    • 2001
  • The objective of this study is to evaluate the design parameters and to develop the cooling and heating load prediction equations of office buildings. The building load calculation simulation was carried out using the DOE-2.1E program. The results of the simulation was used as a data for ANOVA and multiple regression analysis which could develop the load prediction equations.

  • PDF

Performance-based design of seismic isolated buildings considering multiple performance objectives

  • Morgan, Troy A.;Mahin, Stephen A.
    • Smart Structures and Systems
    • /
    • 제4권5호
    • /
    • pp.655-666
    • /
    • 2008
  • In the past 20 years, seismic isolation has see a variety of applications in design of structures to mitigate seismic hazard. In particular, isolation has been seen as a means of achieving enhanced seismic performance objectives, such as those for hospitals, critical emergency response facilities, mass electronic data storage centers, and similar buildings whose functionality following a major seismic event is either critical to the public welfare or the financial solvency of an organization. While achieving these enhanced performance objectives is a natural (and oftentimes requisite) application of seismic isolation, little attention has been given to the extension of current design practice to isolated buildings which may have more conventional performance objectives. The development of a rational design methodology for isolated buildings requires thorough investigation of the behavior of isolated structures subjected to seismic input of various recurrence intervals, and which are designed to remain elastic only under frequent events. This paper summarizes these investigations, and proposed a consistent probabilistic framework within which any combination of performance objectives may be met. Analytical simulations are presented, the results are summarized. The intent of this work is to allow a building owner to make informed decisions regarding tradeoffs between superstructure performance (drifts, accelerations) and isolation system performance. Within this framework, it is possible to realize the benefits of designing isolated buildings for which the design criteria allows consideration of multiple performance goals.

A Systematic Review of Commercial Building Greening with CiteSpace

  • Yimeng Wu;Zhendong Wang;Kai Li;Hao Wang
    • 국제초고층학회논문집
    • /
    • 제12권4호
    • /
    • pp.273-285
    • /
    • 2023
  • The commercial buildings greening can generate multiple benefits to achieve a sustainable building and business environment. However, a comprehensive systematic review of commercial buildings greening across multiple disciplines has yet to be reported. This study conducted a systematic analysis of 39 literature on commercial building greening from Web of Science over the past 19 years and utilized CiteSpace to visualize the academic evolution and trends in this field. Key findings were: 1) The number of publications in the past five years has increased, indicating that commercial building greening research has received widespread attention. 2) The large number of publications means that the research field of commercial building greening is relatively broad. 3) The study of commercial building greening has become a global participation and cooperation research topic. The top cooperating countries mainly come from the United States and Europe, while the differences in cooperation between institutions in developing countries are less significant. 4) The greening of commercial buildings is more related to research on behavioral activities. 5) The research on commercial building greening has developed from architecture and plants to interdisciplinary fields, including psychology, economics, and management. 6) The cost of commercial buildings greening is generally an obstacle to installation. This study provides specific references for stakeholders and plays a crucial role in determining the evolution of commercial building greening research and predicting future research needs and opportunities.

Diagrid Systems for Structural Design of Complex-Shaped Tall Buildings

  • Moon, Kyoung Sun
    • 국제초고층학회논문집
    • /
    • 제5권4호
    • /
    • pp.243-250
    • /
    • 2016
  • Today's architectural design trend based on the recognition of pluralism has led to multiple design directions for all building types including tall buildings. This contemporary design trend has produced many complex-shaped tall buildings, such as twisted, tilted, tapered and freeform towers. Among many different structural systems developed for tall buildings, the diagrid system, with its powerful structural rationale and distinguished aesthetic potential, is one of the most widely used systems for today's tall buildings. This paper studies structural performance of diagrid systems employed for complex-shaped tall buildings. Twisted, tilted, tapered and freeform tall buildings are designed with diagrid structures, and their structural performances are investigated. For the twisted diagrid study, the buildings are twisted up to 3 degrees per floor. In the tilted diagrid study, the angles of tilting range from 0 to 13 degrees. The impact of eccentricity is investigated for gravity as well as lateral loads in tilted towers. In the study of tapered diagrid structures, the angles of tapering range from 0 to 3 degrees. In the study of freeform diagrid structures, lateral stiffness of freeform diagrids is evaluated depending on the degree of fluctuation of free form. The freeform floor plans fluctuate from plus/minus 1.5 meter to plus/minus 4.5 meter boundaries of the original square floor plan. Parametric structural models are generated using appropriate computer programs and the models are exported to structural engineering software for design, analyses and comparative studies.

Outrigger Systems for Structural Design of Complex-Shaped Tall Buildings

  • Moon, Kyoung Sun
    • 국제초고층학회논문집
    • /
    • 제5권1호
    • /
    • pp.13-20
    • /
    • 2016
  • Today's architecture can be best understood only through the recognition of pluralism, and, as is true of other building types, multiple design directions are prevalent for tall buildings. This contemporary design trend has produced many complex-shaped tall buildings, such as twisted, tilted and tapered form towers. Among many different structural systems developed for tall buildings, the outrigger system, with its inherent structural efficiency and flexibility in façade design, is widely used for contemporary tall buildings. This paper studies structural performance of outrigger systems employed for complex-shaped tall buildings. Twisted, tilted and tapered tall buildings are designed with outrigger structures, and their structural performance is investigated. For the twisted outrigger study, the buildings are twisted up to 3 degrees per floor. In the tilted outrigger study, the angles of tilting range from 0 to 13 degrees. The impact of eccentricity is investigated for gravity as well as lateral loads in tilted towers. In the study of tapered outrigger structures, the angles of tapering range from 0 to 3 degrees. Parametric structural models are generated using appropriate computer programs for these studies, and the models are exported to structural engineering software for design and analyses.