• Title/Summary/Keyword: Multidetector Computed Tomography

Search Result 79, Processing Time 0.035 seconds

Application of Dual Tree Complex Wavelet for Performance Improvement of CT Images (CT 영상의 화질개선을 위한 이중트리복합웨이블릿의 적용)

  • Choi, Seokyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.7
    • /
    • pp.941-946
    • /
    • 2019
  • Computed tomography (CT) has been increasing in frequency and indications for use in clinical diagnosis and treatment decisions. Multidetector CT has the advantage of shortening the inspection time and obtaining a high resolution image compared to a single detector CT, but has been pointed out the disadvantage of increasing the radiation exposure. In addition, when the low tube voltage is used to reduce the exposure dose in the CT, noise increases relatively. In the existing method, the method of finding the optimal image quality using the method of adjusting the parameters of the image reconstruction method is not a fundamental measure. In this study, we applied a double-tree complex wavelet algorithm and analyzed the results to maintain the normal signal and remove only noise. Experimental results show that the noise is reduced from 8.53 to 4.51 when using a complex oriented 2D method with 100kVp and 0.5sec rotation time. Through this study, it was possible to remove the noise and reduce the patient dose by using the optimal noise reduction algorithm. The results of this study can be used to reduce the exposure of patients due to the low dose of CT.

Submandibular sialolithiasis with CT and scintigraphy: CT values and salivary gland excretion in the submandibular glands

  • Ogura, Ichiro;Hayama, Kazuhide;Sue, Mikiko;Oda, Takaaki;Sasaki, Yoshihiko
    • Imaging Science in Dentistry
    • /
    • v.47 no.4
    • /
    • pp.227-231
    • /
    • 2017
  • Purpose: Sialolithiasis is one of the most prevalent large obstructive disorders of the submandibular glands. The aim of this study was to investigate submandibular sialolithiasis with computed tomography (CT) and scintigraphy, with a particular focus on the relationship between CT values of the submandibular glands and their excretion rate. Materials and Methods: Fifteen patients with submandibular sialolithiasis who underwent CT and salivary gland scintigraphy were included in this study. The relationship between the CT values of submandibular glands with and without sialoliths and salivary gland excretion measured using salivary gland scintigraphy was statistically analyzed. Dynamic images were recorded on the computer at 1 frame per 20 seconds. The salivary gland excretion fraction was defined as A (before stimulation test [counts/frame]) / B (after stimulation test [counts/frame]) using time-activity curves. Results: The CT values in the submandibular glands with and without sialoliths was $9.9{\pm}44.9$ Hounsfield units(HU) and $34.2{\pm}21.8HU$, respectively (P=.233). Regarding the salivary gland excretion fraction using scintigraphy, the A/B value in the submandibular glands with sialoliths ($1.09{\pm}0.23$) was significantly lower than in the submandibular glands without sialoliths($1.99{\pm}0.57$, P=.000). Conclusion: Assessments of the CT values and the salivary gland excretion fraction using scintigraphy in the submandibular glands seem to be useful tools evaluating submandibular sialolithiasis.

Assessment of Breast Volume Change after Transverse Rectus Abdominis Myocutaneous Flap

  • Park, Sang Uk;Shim, Jeong Su
    • Archives of Plastic Surgery
    • /
    • v.39 no.6
    • /
    • pp.631-635
    • /
    • 2012
  • Background The evaluation of a breast after breast reconstruction depends on a surgeon's subjective criteria. We used computed tomography (CT) scans to obtain an objective evaluation of the postoperative results by measuring the breast volume of patients who had undergone breast reconstruction using pedicled transverse rectus abdominis myocutaneous (TRAM) flaps. This research will help in the objective postoperative evaluation of reconstructed breasts, and also in the preoperative flap size designs. Methods A total of 27 patients underwent breast reconstruction using pedicled TRAM flaps after mastectomy from September 2007 to July 2010. Of these, 10 patients who were followed up and underwent CT scans 2 or more times during the follow-up period were included in this study. We evaluated the change in breast volume over time using CT scans, and the interval breast volume change between CT scans. Results All of the 10 patients' reconstructed breasts showed a volume decrease over time. The breast volume changes in the intervals between CT scans were as follows: 5.65% decrease between the first CT and second CT scan, 2.3% decrease between the second CT and third CT scan, (statistically significant) and 1.89% decrease between the third CT and forth CT scan. (not statistically significant). Conclusions This research shows the possibility of objectively evaluating the postoperative breast volume changes. The findings will be helpful in designing the size of TRAM flaps to use on defects after mastectomy. Based on these results, we should also closely observe the reconstructed breast volume for at least 2 years.

Comparison of the diagnostic performance of panoramic and occlusal radiographs in detecting submandibular sialoliths

  • Kim, Jun Ho;Aoki, Eduardo Massaharu;Cortes, Arthur Rodriguez Gonzalez;Abdala-Junior, Reinaldo;Asaumi, Junichi;Arita, Emiko Saito
    • Imaging Science in Dentistry
    • /
    • v.46 no.2
    • /
    • pp.87-92
    • /
    • 2016
  • Purpose: The aim of this study was to assess and compare the diagnostic performance of panoramic and occlusal radiographs in detecting submandibular sialoliths. Materials and Methods: A total of 40 patients (20 cases and 20 controls) were included in this retrospective study. Cases were defined as subjects with a submandibular sialolith confirmed by computed tomography (CT), whereas controls did not have any submandibular calcifications. Three observers with different expertise levels assessed panoramic and occlusal radiographs of all subjects for the presence of sialoliths. Intraobserver and interobserver agreement were assessed using the kappa test. Sensitivity, specificity, accuracy, positive and negative predictive values, and the diagnostic odds ratio of panoramic and occlusal radiographs in screening for submandibular sialoliths were calculated for each observer. Results: The sensitivity and specificity values for occlusal and panoramic radiographs all ranged from 80% to 100%. The lowest values of sensitivity and specificity observed among the observers were 82.6% and 80%, respectively (P=0.001). Intraobserver and interobserver agreement were higher for occlusal radiographs than for panoramic radiographs, although panoramic radiographs demonstrated a higher overall accuracy. Conclusion: Both panoramic and occlusal radiographic techniques displayed satisfactory diagnostic performance and should be considered before using a CT scan to detect submandibular sialoliths.

Diameters of the Thoracic Aorta Measured with Multidetector Computed Tomography (다중검출 전산화 단층촬영을 이용하여 측정한 흉부대동맥의 직경)

  • Lee, Gun;Lim, Chang-Young;Lee, Hyeon-Jae
    • Journal of Chest Surgery
    • /
    • v.42 no.1
    • /
    • pp.79-86
    • /
    • 2009
  • Background: Background: Computed tomography (CT) is the main tool for detecting abnormalities of the thoracic aorta, but conventional CT only shows the cross-sectional images. These CT images have some limitations fo accuratly measuring the thoracic aortic diameters at various levels. Multidetector computed tomography (MDCT) overcomes these limitations. We measured the thoracic aortic diameter perpendicular to the loop-shaped thoracic aortic course and this was studied in relation to age, gender, height, weight, the body surface area, the body mass index and the presence of hypertension. Material and Method: Thirty hundred thirty one patients (males: 141 patients and females: 190 patients) who had no abnormalities of the thoracic aorta were investigated using MDCT aortography. They were divided into three age categories: 20~39 years old, 40~59 years old and over age 60. The image was reformed with multiplanar reconstruction and the diameter of the aorta was measured perpendicular to the aortic course at 5 anatomic segments. Level A was the mid-ascending aorta, level B was the distal ascending aorta, level C was the aortic arch, level D was the aortic isthmus and level E was the mid-descending aorta. Result: The mean age was 49.5 years old for males and 54.9 years old for females (p<0.05). The mean diameter of the thoracic aorta at level A was 31.1 mm, that at level B was 30.2 mm, that at level C was 26.5 mm, that at level D was 24.0 mm and that at level E was 22.6 mm. The diameters at all the levels were gradually increased with age. Hypertensive patients had larger diameters than did the non-hypertensive population. There was a positive correlation between the ascending aortic diameter (levels A&B) and height and the body surface area, but there were no statistical differences at the aortic arch (level C) and the descending aorta (levels D&E). There were no statistical differences of the weight and body mass index at all levels. Conclusion: The diameters of the thoracic aortas were directly correlated with gender, age and hypertension. Height and the body surface area were only correlated with the ascending aorta. Weight and the body mass index have no statistical difference at all levels. We measured the age related thoracic aortic diameters and the upper normal limits and we provide this data as reference values for the thoracic aortic diameter in the Korean population.

Analysis of Bone Mellow Density in Adults of Domestic Local Area Using Multi-Detector Computed Tomography: Focus on Corelation About Eating Habits, Lifestyle, Physical Features and Social Characteristics (다중 검출 전산화단층촬영을 이용한 국내 일부 지역 성인의 골밀도 현황 분석: 식습관, 생활습관, 신체적, 사회적 특성과의 상관관계를 중심으로)

  • Lee, Tae Hui;Kim, Tae-Hyung;So, Woon Young;Lim, Hei Gyeom;Lim, Cheong-Hwan;Park, Myeong Hwan;Cheoun, Myung-Ki
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.517-526
    • /
    • 2016
  • This study analyzed the correlation between BMD (bone mineral density) value calculated in the MDCT (multidetector computed tomography) and lifestyle, physical features and social characteristics. From July 15 2015 to June 6 2016, we converted from HU (hounsfield unit) value measured by using MDCT to T-score for BMD of 141 patients (male: 63, female: 78) in W medical center. We measured the 2nd, 3rd and 4th lumbar spine and analyzed the correlation between gender differences in BMD and lifestyle, physical features and social characteristics. Statistical significance was validated using independent sample T test with one way Anova. Gender BMD was confirmed that a statistically significant difference (p<0.05). BMD values decreased with increasing age but for the statistically men, there was no significant difference from 20s to 50s, it only showed a significant difference in 20s and 60s (p<0.001). For the statistically women, there was no significant difference from 20s to 40s. but since 50s BMD was decreased rapidly, which showed a significant difference (p<0.001). women showed significant differences for the menstruation and menopause, childbirth, alcohol, cereals and greasy food in bone mineral density (p<0.05) but there were no significant differences in men. The bone mineral density values calculated by the MDCT and lifestyle, physical features and social characteristics correlation analysis method is considered to be used as a basis for estimating the state in BMD and osteoporosis management.

Acute Pulmonary Embolism: Clinical Characteristics and Outcomes in a University Teaching Hospital (한 대학병원에서 급성 폐색전증으로 진단된 환자들의 임상적 특성 및 예후)

  • Chae, Jin-Nyeong;Choi, Won-Il;Park, Jie-Hae;Rho, Byung-Hak;Kim, Jae-Bum
    • Tuberculosis and Respiratory Diseases
    • /
    • v.68 no.3
    • /
    • pp.140-145
    • /
    • 2010
  • Background: Pulmonary embolism (PE) is a common clinical problem in the West that is associated with substantial morbidity and mortality. The diagnostic modality has been changed since 2001. This study retrospectively reviewed the PE mortality with the aim of identifying the risk factors associated with mortality since the multidetector computed tomography (MDCT) was introduced. Methods: We analyzed 105 patients with acute PE proven by multidetector CT or ventilation perfusion scan. The primary outcome measure was the all-cause mortality at 3 months. The prognostic effect of the baseline factors on survival was assessed by multivariate analysis. Results: The main risk factors were prolonged immobilization, stroke, cancer and obesity. Forty nine percent of patients had 3 or more risk factors. The overall mortality at 3 months was 18.1%. Multivariate analysis revealed low diastolic blood pressure and the existence of cancer to be independent factors significantly associated with mortality. Forty two PE patients were examined for the coagulation inhibitors. Four of these patients had a protein C deficiency (9.5%), and 11 had a protein S deficiency (26%). Conclusion: PE is an important clinical problem with a high mortality rate. Close monitoring may be necessary in patients with the risk factors.

Hepatic Pseudolymphoma Mimicking a Hypervascular Tumor: A Case Report (과혈관성 종양으로 오인된 간의 가성림프종: 증례보고)

  • Im, Bora;Jang, Suk Ki;Yeon, Jae Woo;Paik, So Ya;Park, Sang Jong;Kim, Hyuk Jung
    • Journal of the Korean Society of Radiology
    • /
    • v.79 no.6
    • /
    • pp.348-353
    • /
    • 2018
  • Hepatic pseudolymphoma is a rare benign liver mass that is characterized by proliferation of non-neoplastic lymphocytes extranodally. To the best of our knowledge, only 46 cases have been reported in the English literature. We described the case of a 75-year-old woman with hepatic pseudolymphoma mimicking a hypervascular tumor. After the histological confirmation of the rectal neuroendocrine tumor, CT scan revealed a 1.0 cm-sized, poorly-defined and low-density nodule in the liver. On MRI, the hepatic nodule showed an arterial enhancement and a low-signal intensity on the hepatobiliary phase. On diffusion-weighted imaging, the hepatic nodule showed a high signal intensity on a high b-value. On fluorodeoxyglucose (FDG) positron emission tomography (PET)/CT, it revealed a high standardized uptake value nodule. The US showed the hypoechoic nodule and the US-guided biopsy confirmed the hepatic pseudolymphoma.

Difference in glenoid retroversion between two-dimensional axial computed tomography and three-dimensional reconstructed images

  • Kim, Hyungsuk;Yoo, Chang Hyun;Park, Soo Bin;Song, Hyun Seok
    • Clinics in Shoulder and Elbow
    • /
    • v.23 no.2
    • /
    • pp.71-79
    • /
    • 2020
  • Background: The glenoid version of the shoulder joint correlates with the stability of the glenohumeral joint and the clinical results of total shoulder arthroplasty. We sought to analyze and compare the glenoid version measured by traditional axial two-dimensional (2D) computed tomography (CT) and three-dimensional (3D) reconstructed images at different levels. Methods: A total of 30 cases, including 15 male and 15 female patients, who underwent 3D shoulder CT imaging was randomly selected and matched by sex consecutively at one hospital. The angular difference between the scapular body axis and 2D CT slice axis was measured. The glenoid version was assessed at three levels (midpoint, upper one-third, and center of the lower circle of the glenoid) using Friedman's method in the axial plane with 2D CT images and at the same level of three different transverse planes using a 3D reconstructed image. Results: The mean difference between the scapular body axis on the 3D reconstructed image and the 2D CT slice axis was 38.4°. At the level of the midpoint of the glenoid, the measurements were 1.7°±4.9° on the 2D CT images and -1.8°±4.1° in the 3D reconstructed image. At the level of the center of the lower circle, the measurements were 2.7°±5.2° on the 2D CT images and -0.5°±4.8° in the 3D reconstructed image. A statistically significant difference was found between the 2D CT and 3D reconstructed images at all three levels. Conclusions: The glenoid version is measured differently between axial 2D CT and 3D reconstructed images at three levels. Use of 3D reconstructed imaging can provide a more accurate glenoid version profile relative to 2D CT. The glenoid version is measured differently at different levels.

A Computed Tomography Analysis of the Success of Spinal Fusion Using Ultra-Low Dose (0.7 mg per Facet) of Recombinant Human Bone Morphogenetic Protein 2 in Multilevel Adult Degenerative Spinal Deformity Surgery

  • Liu, Gabriel;Tan, Jun Hao;Yang, Changwei;Ruiz, John;Wong, Hee-Kit
    • Asian Spine Journal
    • /
    • v.12 no.6
    • /
    • pp.1010-1016
    • /
    • 2018
  • Study Design: Retrospective cohort study. Purpose: To report on spinal fusion assessment using computed tomography (CT) after adult spinal deformity (ASD) surgery using ultra-low dose recombinant human bone morphogenetic protein 2 (RhBMP-2). Overview of Literature: The reported dose of RhBMP-2 needed for successful spinal posterolateral fusion in ASD ranges from 10 to 20 mg per spinal level. This study reports the use of ultra-low dose of RhBMP-2 (0.07 mg per facet) to achieve spinal fusion in multilevel ASD surgery. Methods: Consecutive patients who underwent ASD surgery using ultra-low dose RhBMP-2 were recruited. Routine postoperative CT analysis for spinal fusion was performed by two spine surgeons. Inter-observer agreement was calculated for facet fusion (FF) and interbody fusion (IBF) at 6 and 12 months after the procedure. Results: Six consecutive ASD patients with a mean age of 62 years (28-72 years) were examined. Each patient received a total dose of 12 mg with an average dose of $0.69{\pm}0.2mg$ (0.42-1 mg) per single FF and $1.38{\pm}0.44mg$ (0.85-2 mg) for IBF. Total 131 FF and 15 IBF were examined in the study, with 88 FFs and nine IBFs being analyzed specifically at 6 months after the surgery. FF and IBF reported by surgeons A and B at 6 months were 97.7% vs. 91.9% FF, respectively (${\kappa}=0.95$) and 100% vs. 100% IBF, respectively (${\kappa}=1$). Two patients underwent longitudinal follow-up CT at 12 months, and the FF rates reported by surgeons A and B were 100% vs. 95.8%, respectively (${\kappa}=0.96$). Five out of nine facet (56%) non-unions were identified at the cross-links. The remaining four facet pseudarthrosis were noted at 1-2 spinal levels caudal to the cross-links. At the final clinical follow-up, there was no rod breakage, deformity progression, neurological deficit, or symptom recurrence. The Oswestry Disability Index improved by an average of $32.8{\pm}6.3$, while the mental component summary of the 36-item Short-Form Health Survey improved by an average of $4.7{\pm}2.1$, and physical component summary improved by an average of $10.5{\pm}2.1$. Conclusions: To our knowledge, this is the first study to report a CT that defined 92%-98% FF and 100% IBF using the lowest reported dose of RhBMP-2 in multilevel ASD surgery. The use of ultra-low dose RhBMP-2 reduces the RhBMP-2 related complications and healthcare costs.