• Title/Summary/Keyword: Multi-use Facilities

Search Result 227, Processing Time 0.036 seconds

A Study on The Color Examination and Color Planning in the Different Type of Classroom (학교 교실의 용도별 색채분포 및 색채계획에 관한 연구)

  • 김은정;김기환
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2003.05a
    • /
    • pp.65-68
    • /
    • 2003
  • The purpose of this study is examine the color planning in the different type of classroom to establish interior color planning. This study also uses environmental planning and practical use of basic data for color planning to future school facilities. The summary of this study is as followed. The primary school and middle school classrooms as well as the open space classrooms floor color recommended of brown and the primary school wall color is light yellow, middle school wall color is light yellow and brown. The high school classroom color is recommended brown and wall color to light yellow and green system. The recommended floor color of primary school which includes in computer room and language study room, library of the multi-purpose of media room recommended are gray, brown and pink. The recommended wall color in primary school is light gray. The middle school floor color propose gray and light brown and wall recommended color is light brown, gray, ivory with the high school the computer room, language study room and library. The floor color is recommended gray, green and the wall propose blue. Moreover, recognize that importance of color effectiveness in school interior facilities considering with Interior covering material in class room.

  • PDF

Measurement of Air Contaminants Emission from Interior Finish Material (실내 건축 마감자재의 공기오염물질 방출량 분석)

  • Kim, Yun-Deok;Lim, Soo-Young
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.14 no.1
    • /
    • pp.58-65
    • /
    • 2007
  • For the moderns who spend more than 80% of the time inside a building, interior environment became important since it directly affects their health. Recently as noxiousness of the air contaminants of the interior space stood out as well as the above trend, the Ministry of Environment enacted a lawto maintain the interior air quality at certain level of standard in the multi use facility and newly constructed apartment. To make the indoor air clean, removal technology of various contaminants should be developed and interior materials with chemical treatment should be restrained. In other words, selection of interior finish affects indoor air quality from the initial design stage to the construction stage. However, only limited contaminants emission data of building materials are supplied by related companies. There is no average contaminants emission data for overall materials. Moreover, high cost and equipments for one time measurement of VOCs emission of interior finish are the obstacles of active research and data measurement. Therefore, this paper searched the current condition of average VOCs & HCHO emission of various interior finish based on the study requested to research center from the building material company through Stands Test Method for Indoor Air Quality.

Development of the Noise Prediction Program to apply in Construction Site (현장 적용성을 향상시킨 건설현장 소음예측프로그램 개발)

  • Oh, Jin-Kyun;Park, Hye-Na;Sohn, Jang-Ryul
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.302-309
    • /
    • 2009
  • Nowadays, the construction sites are growing in city every year, so complaints for construction noise have increased more and more. To analyze this noise scientifically, construction noise prediction program was developed in 1998 and 2005 but it is too difficult to apply program in field because there is few soundproof facilities and it can't understand the coordinate system and so on. The aim of this study is to develop noise prediction program to apply in construction sites. For this, the problems of existing program was analyzed and survey was performed to get requestion of field overseer and upgraded program. To get reliability of program, it was compared with sound measurement value in field. As a result, construction sound prediction program have various soundproof facilities data than existing program. It can also analyze multi receiver point at the same time for several construction machinery. Most of all, it is more powerful to set receiver or source in the axis of X, Y, Z. so program user can make use of it easily. An average of difference is -0.9$\sim$1.8dB.

  • PDF

Development of the Noise Prediction Program to apply in Construction Site (현장 적용성을 향상시킨 건설현장 소음예측프로그램 개발)

  • Oh, Jin-Kyun;Park, Hye-Na;Sohn, Jang-Ryul
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.4
    • /
    • pp.409-417
    • /
    • 2009
  • Nowadays, the construction sites are growing in city every year, so complaints for construction noise have increased more and more. To analyze this noise scientifically, construction noise prediction program was developed in 1998 and 2005 but it is too difficult to apply program in field because there is few soundproof facilities and it can't understand the coordinate system and so on. The aim of this study is to develop noise prediction program to apply in construction sites. For this, the problems of existing program was analyzed and survey was performed to get requestion of field overseer and upgraded program. To get reliability of program, it was compared with sound measurement value in field. As a result, construction sound prediction program have various soundproof facilities data than existing program. It can also analyze multi receiver point at the same time for several construction machinery. Most of all, it is more powerful to set receiver or source in the axis of X, Y, Z. so program user can make use of it easily. An average of difference is -0.9~1.8 dB.

A Case Study of Measuring and Analyzing Electric Energy Usage in University Facilities Using Smart Plug (스마트플러그(IOT)를 이용한 대학시설의 전기에너지 사용량 계측 및 분석 사례 연구)

  • Park, Jun-Young;Lee, Chun-Kyong;Park, Tae-Keun
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.9
    • /
    • pp.27-34
    • /
    • 2018
  • The purpose of this study is to demonstrate and analyze the function of a Smart Plug before and after it is applied on the electrical appliances by controlling standby power usage. The research measures and analyzes the amount of electrical energy used while activating the Smart Plug with two types of appliances in a university facilities. The smart plugs were applied into a Group 1 appliances (Multi-function device, computer, laptop, Air con) which completely hinder the standby power, and a Group 2 appliances (Refrigerator, cold and hot water dispenser) which does not completely hinder the standby powers due to the characteristics of the function. First, the total standby power saving of all electrical appliances (Group 1 and Group 2) using the Smart plug was measured as 4.59%. Second, the energy saving of the Group 1 products was analyzed as 26.43%. Third, the standby power saving of the air conditioners from mid October to early December was measured as 31.06%, during the seasons when air conditioning was not actively in use. The research indicates that all specified appliances did have better energy efficiency with the Smart plug regardless of the amount of energy usage.

Compact AUV platform system designed for the experiment of underwater multi-agent development

  • Watanabe, Keisuke
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.2036-2041
    • /
    • 2005
  • The underwater multi-agent technology has many potential for the various activities related to ocean development/conservation in the near future. For example, in such fields as water pollution investigation, aquaculture control, or coral reef research, we feel a growing need for a system that realizes underwater continuous monitoring in the wide rang e. In this case, the target monitoring area will be sliced planar hierarchically toward the depth as monitoring layers, and many AUVs arranged on each layer track the given trajectory and gather various environmental information continuously, with communicating each other in the layer or with other layers. To realize those systems we need to develop AUV multi-agent technologies. So we are now building basic systems for basin experiment for the development of AUV multi-agent behavior. We must experience many situations and problems to be solved for the development of its elemental technologies by using real systems as well as our computer simulations. In this paper we introduce our concept of the experiment in the near future and the hardware/software design of our two types of handy AUVs and ultrasound ranging/communication system for that experiment. One AUV is designed using a 17inches-diameter glass sphere with DOS/V and RT-Linux based subsystems, which is intended to use not only in the basin but also in the calm real sea. The other AUV is designed for the basin experiment using a 7inches-diameter acrylic sphere with low-cost embedded system with SH-2 based subsystems. The basin experiment to verify the basic AUV facilities and ultrasound ranging for position detection was carried out.

  • PDF

A Study on the Mask Microbial Contamination by Working Environment and Wearing Time (착용자 환경 및 시간에 대한 마스크 미생물 오염 연구)

  • Seo, Hyekyung;Kwon, Young-il;Lee, Seong Yeoun;Kang, Byoung-kab;Myong, Jun-Pyo;Jang, Hoyeong;Kim, HuiJu;Shim, SuA;Park, SungWook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.31 no.4
    • /
    • pp.427-439
    • /
    • 2021
  • Objectives: This study aims to investigate differences in microbial contamination according to the duration and environment of mask wearing. Methods: Forty-five participants were recruited from workers in an offices, multi-purpose facilities, and a schools. After wearing of KF94 mask for two. four, and six hours, the microorganisms adsorbed on the outer and inner layers of the mask were inoculated on BAP(Blood Agar Plate), Chocolate agar, and SDA plates. The bacterial count (CFUs: colony-forming units) cultured in each plate was measured and analyzed for changes in filtration efficiency. Results: The microbial contamination of masks worn in classrooms, offices, and multi-purpose facilities showed a significant difference depending on the environment (p<0.000). The measured CFUs increased significantly according to the time wearing the mask. The difference between the inner and outer layers of the mask was also significant (p<0.05). However, there was no statistical difference in the filtration efficiency of the masks by duration time (p=0.515). Conclusions: Masks worn by workers in the offices, multi-purpose facilities, and schools showed an increase of microbial contamination with the amount of time wearing the mask. The results indicate that the masks used in daily life may have adverse health effects if they are worn for a long time or reused over several days without the realizing that the masks can be contaminated with biological hazards. Guidelines on the safe threshold time for mask use should be established through further research.

Development of IoT Sensor-Gateway-Server Platform for Electric Fire Prediction and Prevention (전기화재 예측 및 예방을 위한 IoT 센서-게이트웨이-서버 플랫폼 개발)

  • Yang, Seung-Eui;Kim, Hankil;Song, Hyun-ok;Jung, Heokyung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.05a
    • /
    • pp.255-257
    • /
    • 2021
  • During the winter season, when electricity usage increases rapidly every year, fires are frequent due to short circuits in aging electrical facilities in multi-use facilities such as traditional markets and jjimjilbangs, apartments, and multi-family houses. Most of the causes of such fires are caused by excessive loads applied to aging wires, causing the wire covering to melt and being transferred to surrounding ignition materials. In this study, we implement a system that measures the overload and overheating of the wire through a composite sensor, detects the toxic gas generated there, and logs it to the server through the gateway. Based on this, we will develop a platform that can predict, alarm and block electric fires in real time through big data analysis, and a simulator that can simulate fire occurrence experiments.

  • PDF

Demand Characteristics and Analysis of Changes in Spatial Accessibility of Public Sports Facilities (공공체육시설 수요특성 및 공간적 접근성 분석)

  • Kim, Seong-Hee;Kim, Yong-Jin
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.7
    • /
    • pp.283-293
    • /
    • 2017
  • This study analyzed the actual conditions of use of public sports facilities and characteristics of the users of the facilities through surveys and measured the spatial imbalance of the public sports facilities currently supplied by using gravity potential model. This study also suggests evaluation criteria that may be considered for efficient location selection by examining the change of accessibility to the facilities that meet the needs of users in the future. As the results of the questionnaire survey, unlike current usage, the users hoped for badminton, weight training and swimming. And we could confirm the demand for the expansion of the multi - purpose indoor gym which can carry out such activities in the areas. As the result of the analysis on the difference in accessibility of the public sports facility, there were some large variations in the regions. It was found that a balanced supply of facilities was needed in terms of equity. In particular, when analyzing by considering the population estimates of 2025, It is analyzed that the accessibility will be reduced to about 60% compared to that of 2015. In addition, it is evaluated as the best alternative in terms of overall efficiency that the location of the facilities should be in Munsan area where population growth is expected in the future.

Development of General-Purpose Remote Maintenance Controller Gateway for Multi-Modal Photovoltaic Equipment (이기종 태양광 설비 지원을 위한 범용 RMC 게이트웨이 개발)

  • Lim, Su-Chang;Hong, Seok-Hoon;Park, Chul-Young;Song, Beob-Seong;Kim, Jong-Chan
    • Journal of Korea Multimedia Society
    • /
    • v.23 no.10
    • /
    • pp.1307-1317
    • /
    • 2020
  • In recent years, the PV plant is gradually increasing in korea and has begun to focus on PV system O&M(Operation and Management). The legacy PV system can hardly be gathering realtime information. That is why it is difficult for the facility to respond immediately to situations in which problems arise. This leads to economic losses due to reduced power generation. In this study, we implemented an RMC(Remote Maintenance Control) gateway that supports multi-area equipment(inverters, junction boxes, switchboards, environmental sensors) that are not limited to specific manufacturers. It provides a function to visualize the collected data. Users can easily check the power generation and operation status of PV system equipment. In the future, we will develop an algorithm capable of analyzing beta factors that cause equipment performance degradation, parts aging, and deterioration using data collected from facilities. We intend to use this algorithm as a fundamental technology for O&M by transplanting it to the RMC gateway.