• Title/Summary/Keyword: Multi-standards

Search Result 509, Processing Time 0.023 seconds

Sensing method of multi-component forces and moments using a column structure (기둥을 이용한 다축 힘/모멘트 감지 방법에 관한 연구)

  • Shin, H.H.;Kang, D.I.;Park, Y.K.;Kim, J.H.;Joo, J.W.;Kim, O.H.
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.837-841
    • /
    • 2001
  • The column-type sensing element in building and mechanical construction parts was designed as three forces and three moments sensor by attaching strain gages approximately. Compared to conventional multi-component sensor, the designed sensor can solve the problem about low stiffness and high cost. The radius of the column was designed analytically and compared with finite element analysis. The coupling errors between components were minimized by using addition and subtraction procedure of signals. The fabricated sensor was tested by using a deadweight force standard machine and a six-component force calibration machine in Korea Research Institute of Standards and Science(KRISS). The calibration showed that the multi-component force/moment sensor had coupling error less than 19.8 % between $F_x$ and $M_y$ components, and 9.0 % in case of other components.

  • PDF

Compressed Sensing-Based Multi-Layer Data Communication in Smart Grid Systems

  • Islam, Md. Tahidul;Koo, Insoo
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.7 no.9
    • /
    • pp.2213-2231
    • /
    • 2013
  • Compressed sensing is a novel technology used in the field of wireless communication and sensor networks for channel estimation, signal detection, data gathering, network monitoring, and other applications. It plays a significant role in highly secure, real-time, well organized, and cost-effective data communication in smart-grid (SG) systems, which consist of multi-tier network standards that make it challenging to synchronize in power management communication. In this paper, we present a multi-layer communication model for SG systems and propose compressed-sensing based data transmission at every layer of the SG system to improve data transmission performance. Our approach is to utilize the compressed-sensing procedure at every layer in a controlled manner. Simulation results demonstrate that the proposed monitoring devices need less transmission power than conventional systems. Additionally, secure, reliable, and real-time data transmission is possible with the compressed-sensing technique.

Multi-Symbol Binary Arithmetic Coding Algorithm for Improving Throughput in Hardware Implementation

  • Kim, Jin-Sung;Kim, Eung Sup;Lee, Kyujoong
    • Journal of Multimedia Information System
    • /
    • v.5 no.4
    • /
    • pp.273-276
    • /
    • 2018
  • In video compression standards, the entropy coding is essential to the high performance compression because redundancy of data symbols is removed. Binary arithmetic coding is one of high performance entropy coding methods. However, the dependency between consecutive binary symbols prevents improving the throughput. For the throughput enhancement, a new probability model is proposed for encoding multi-symbols at one time. In the proposed method, multi-symbol encoder is implemented with only adders and shifters, and the multiplication table for interval subdivision of binary arithmetic coding is removed. Compared to the compression ratio of CABAC of H.264/AVC, the performance degradation on average is only 1.4% which is negligible.

Performance Evaluation of Turbo Codes by Soft Detection Metrics of STBC over an IEEE 802.16e Link (IEEE 802.16e 링크에서 시공간 블록 부호의 연판정 검출에 따른 터보 부호의 성능평가)

  • Kim, Young-Min;Kim, Soo-Young;Lim, Kwang-Jae
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.47 no.2
    • /
    • pp.1-8
    • /
    • 2010
  • Multi antenna techniques using space-time codes can achieve diversity gains in a multi-path environment without additional bandwidth requirement. Most of the 4G candidate standards including the IEEE 802.16e adopt multi-input multi-output (MIMO) schemes to achieve either high throughput performance or diversity gains. In these 4G candidate standards, turbo codes using an iterative decoder with soft input soft output are used to overcome serious channel fading. For this reason, the estimated signal values from MIMO detectors should be soft decision detection values. In this paper, we propose efficient methods to estimate soft decision detection values for various space time coding schemes, and provide the simulation results of turbo coded space time coding scheme over an IEEE 802.16e link.

Radio transmission link design based on a test bed considering a multi-beam active phase array antenna (다중빔 능동위상배열 안테나를 고려한 테스트베드 기반 Radio 전송링크 설계)

  • Youn, Jong-Taek;Kim, Yongi;Park, Hongjun;Park, Juman
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.11
    • /
    • pp.1574-1580
    • /
    • 2021
  • This paper designs and presents the results of an air network simulation radio transmission link applied with a multi-beam active phase array antenna simulator in a testbed system for verifying an air network currently underway as a technology development task. Using the Ku band, the Radio transmission link was designed in consideration of the link budget to satisfy the requirements for the system being developed. Considering short-distance links and long-distance links, the required EIRP and G/T performance scales of multi-beam repeaters and mission planes were applied to confirm the minimum and maximum link margins based on Eb/No. In this Radio Transmission Link design, the application analysis results such as rainfall availability are used to effectively establish standards when selecting the operating radius of the multi-beam relay system and related system standards.

Major Issues and Improvement Measures for Disputes between Construction Companies and Residents Related to Defects in Multi-Family Housing Complexes (건설사와 입주민의 공동주택 하자분쟁 쟁점 및 개선 방안)

  • Bang, Hong-Soon;Kim, Ok-Kyue
    • Journal of the Korea Institute of Building Construction
    • /
    • v.22 no.1
    • /
    • pp.103-114
    • /
    • 2022
  • In the area of construction defects, residents have a tendency to focus on visually identifiable defects, while construction companies focus on defects that affect the structural and functional integrity of apartment housing. Accordingly, construction companies and residents have conflicting views on defects in apartment housing. To address this issue, this study aimed to accurately identify the main disputes surrounding defects in multi-family housing complexes or multi-dwelling unit apartment housing caused by such sharply different perspectives and suggest improvement measures. First, standards to determine different defects and remuneration standards between the Ministry of Land, Infrastructure and Transport and the court were analyzed. Then, problems were derived through an analysis of defects in past court cases, and the differences in perspectives between construction companies and residents were identified based on defect data from various construction companies. To tackle these issues, a classification measure for establishing a defect database for multi-family homes was also proposed.

A Review of Accounting Standards for Tax Effect Accounting (세효과회계에 관한 각국의 동향)

  • Jung Moon-Hyun;Roh Hyun-Sub
    • Management & Information Systems Review
    • /
    • v.7
    • /
    • pp.93-111
    • /
    • 2001
  • In this article, we perform an international overview of accounting standards for tax effect accounting(or income taxes). Specially, we compare accounting standards for tax effect accounting of U.S. and International Accounting Standards. The principal component of U.S. accounting standards for tax effect accounting is as follow. Statement of Financial Accounting Standards No. 109, Accounting for Income Taxes (SFAS No. 109) represents the culmination of a multi-year process in which Financial Accounting Standards Board (FASB) reviewed and subsequently modified the requirements for accounting for income taxes. SFAS No. 109 requires an 'asset and liability' approach for the accounting for income taxes. That is, deferred income taxes are viewed as assets and liabilities of the firm, and deferred tax expenses id determined by the current-year change in the firm's deferred tax liabilities and assets. Previously, Accounting Principles Board Opinion No. 11, Accounting for Income Taxes (APB No. 11) required a 'deferral' approach to accounting for income taxes. The primary intent of the deferral approach was to match tax expense with corresponding revenues and expenses for the year in which the revenues and expenses were recognized in the financial statement. Unlike the SFAS No. 109, APB No. 11 did not require firms to adjust deferred tax balances for subsequent events such as changes in tax rates or laws. And, the principal deference between SFAS No. 109 and the previous statement on accounting for income taxes, SFAS No. 96, is that SFAS No. 109 requires firms to recognize deferred tax assets for the tax benefits of tax credit or operating loss carryforwards, no matter how likely the firm was to realize these benefits, and this was one of the reasons for its demise.

  • PDF

Development of magnetocardiograph system using YBCO SQUID magnetometers (YBCO SQUID 자력계를 이용한 자기심장검사장치 개발)

  • Kim, I.S.;Oh, S.H.;Lim, H.K.;Lee, Y.H.;Lee, S.G.;Park, Y.K.
    • Progress in Superconductivity
    • /
    • v.8 no.2
    • /
    • pp.158-163
    • /
    • 2007
  • YBCO do superconducting quantum interference device (SQUID) magnetometers based on bicrystal junctions have been fabricated for magnetocardiograph (MCG) measurements. We could fabricate YBCO SQUID magnetometers having magnetic field noise of about $20fT/Hz^{1/2}$ at white noise region. We have developed an MCG system employing the high performance SQUID magnetometers. The lightweight MCG system, requiring liquid nitrogen as a coolant, consists of 6-channel SQUID sensors, an adjustable patient bed with sliding motion, and data analyses software. The MCG system could record quite clear MCG signals in a room with moderate magnetic shielding. In normal operation with multi-position MCG measurements, we could obtain clear 48-point mappings of magnetic field map and current source map with high enough signal qualities far clinical trials.

  • PDF

Fabrication of Planar Multi-junction Thermal Converter (평면형 다중접합 열전변환기의 제작)

  • Kwon, Sung-Won;Park, S.I.;Cho, Y.M.;Kang, J.H.
    • Journal of Sensor Science and Technology
    • /
    • v.5 no.4
    • /
    • pp.17-24
    • /
    • 1996
  • Planar multi-junction thermal converters were fabricated for precise measurements of the ac voltage and current by an ac-dc transfer method. A heater and a thermocouple array were fabricated onto a sandwiched membrane, $Si_{3}N_{4}$ (200 nm) / $SiO_{2}$ (400 nm) / $Si_{3}N_{4}$ (200 nm), a thickness of $0.8\;{\mu}m$ and a size of $2{\times}4\;mm^{2}$, which is supported by a surrounding frame. The NiCr heater is located at the center of the membrane vertically. Hot junctions of $48{\sim}156$ pairs of thermocouples (Cu-CuNi44) are located near or onto the heater, and cold junctions are located onto the silicon frame. Output of the thermal converters for 10 mA dc input was $76\;mV{\sim}382\;mV$ dependent on a model, and short term stability of the outputs was ${\pm}5{\sim}15\;ppm$/ 10 min with 5 mA dc input. Responsivity in air was in the range of $3.9{\sim}14.5V/W$. Responsivity of the model BF48 in air which has 48 thermocouples was 2 times or greater than that of 3 dimensional multi-junction thermal converter in vacuum which has 56 thermocouples. AC-DC transfer differences with an input of 10 mA or less were less than ${\pm}1\;ppm$ in the frequency range from 5 Hz to 2 kHz, and about $2{\sim}3\;ppm$ at 5 kHz and 10 kHz.

  • PDF

Research & Development of High Performance & Multi-Functional New Grouting Materials for Ground Improvement & Reinforcement (고성능 다기능 특수 그라우트 신재료 개발 및 기초지반보강재로의 사례 연구)

  • Park, Bong-Geun;Cho, Kook-Hwan;Na, Kyung;Yoon, Tae-Gook;Lee, Yong-Jun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.338-350
    • /
    • 2010
  • As existing materials for ground reinforcement, chemical grout material using cementitous materials and waterglass was used. But many problems in terms of ground reinforcement effects were implicated. In this study, for development and applicability verification of new materials, viscosity, fluidity, permeability, Self-Leveling, keeping of drilled hole, antiwashout underwater, resistance of water (groundwater dilution and minimize material eluting) and the early strength and long-term strength characteristics of developed materials was confirmed, and material standards, and establishing construction standards for the various model tests were conducted. As a result, high viscosity, flowability, permeability and keeping of drilled hole characteristics are excellent, in addition to the early strength properties, dilution does nat occur to groundwater, including groundwater is available for dealing with environmental issues. Application of basic and reinforcement method by Filler function in addition to structure can also or development of a new concept can be expected. In addition, middle and large-diameter drilled shaft, micropile, ground anchors, soil-nailing, steel pipes multi-grouting reinforcement for cement injection process could be used enough to even be considered.

  • PDF