• 제목/요약/키워드: Multi-piping

검색결과 61건 처리시간 0.022초

주조 오스테나이트 스테인리스강 상경계 균열부 산화물 분석 (Analysis of Oxide Layers in Phase Boundary Crack of Cast Austenitic Stainless Steel)

  • 최민재;김성우
    • 한국압력기기공학회 논문집
    • /
    • 제19권2호
    • /
    • pp.171-178
    • /
    • 2023
  • For the phase boundary crack found in the gasket made of cast austenitic stainless steel in the nuclear power plant, the oxide layers were analyzed through SEM and TEM. The results showed that cracks initiated and propagated along the austenite/δ-ferrite phase boundary, the propagation path was changed to penetrate the inside of the phase. The oxide layer located at the periphery of the crack along the phase boundary was identified as a complex multi-layered spinel structure, and Cr-rich carbides were also detected in the oxide. The cracks that propagated inside the austenite matrix were attributed to the presence of high external stresses and impurities.

유한요소법을 이용한 수평형 다단원심펌프의 내진해석 (Seismic Analysis of Horizontal-Type Multi-Stage Centrifugal Pump using Finite Element Method)

  • 조진래;이홍우;김민정;하세윤
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제27권6호
    • /
    • pp.790-796
    • /
    • 2003
  • As a fluid machinery for piping liquid in the reactor cooling system, multi-stage centrifugal pump requires the structural dynamic stability against external dynamic excitation. This paper is concerned with the finite element analysis of its eigen behavior and seismic response to RRS(Required Response Spectrum) curves in the case of SSE (Safe Shutdown Earthquake). Through the finite element analysis, the major vibration characteristics of multi-stage centrifugal pump(MSCP) are investigated and seismic qualification based on the IEEE codes is executed. The numerical results show that the MSCP used in this study has enough seismic strength.

내진실험 연구를 위한 다지점 가진 지동대의 활용 (Applications of Seismic Test using Multi-platform Shaking Table System)

  • 최형석;김남식;정진환
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2013년도 추계학술대회 논문집
    • /
    • pp.126-131
    • /
    • 2013
  • As the testing instrument for seismic research, the multi-platform shaking table system of SESTEC in the Pusan National University was introduced to suggest the multi-support shaking table testing methods and also to investigate its ability and applicability. 2 spans single-pylon cable-stayed bridge model, 3 spans girder bridge model and nuclear piping system model are presented and the acceleration and displacement table feedbacks of the each tests are compared to verify the simultaneous excitation ability in time domain and frequency domain.

  • PDF

Modelling of multidimensional effects in thermal-hydraulic system codes under asymmetric flow conditions - Simulation of ROCOM tests 1.1 and 2.1 with ATHLET 3D-Module

  • Pescador, E. Diaz;Schafer, F.;Kliem, S.
    • Nuclear Engineering and Technology
    • /
    • 제53권10호
    • /
    • pp.3182-3195
    • /
    • 2021
  • The implementation and validation of multi-dimensional (multi-D) features in thermal-hydraulic system codes aims to extend the application of these codes towards multi-scale simulations. The main goal is the simulation of large-scale three-dimensional effects inside large volumes such as piping or vessel. This novel approach becomes especially relevant during the simulation of accidents with strongly asymmetric flow conditions entailing density gradients. Under such conditions, coolant mixing is a key phenomenon on the eventual variation of the coolant temperature and/or boron concentration at the core inlet and on the extent of a local re-criticality based on the reactivity feedback effects. This approach presents several advantages compared to CFD calculations, mainly concerning the model size and computational efforts. However, the range of applicability and accuracy of the newly implemented physical models at this point is still limited and needs to be further extended. This paper aims at contributing to the validation of the multi-D features of the system code ATHLET based on the simulation of the Tests 1.1 and 2.1, conducted at the test facility ROCOM. Overall, the multi-D features of ATHLET predict reasonably well the evolution from both experiments, despite an observed overprediction of coolant mixing at the vessel during both experiments.

하나로 유동모의 설비의 유체순환계통 해석 (The Analysis of Flow Circulation System for HANARO Flow Simulated Test Facility)

  • 박용철
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2002년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.419-424
    • /
    • 2002
  • The HANARO, a multi-purpose research reactor of 30 MWth open-tank-in-pool type, has been under normal operation since its initial criticality In February, 1995. Many experiments should be safely performed to activate the utilization of the HANARO. A flow simulation facility is being developed for the endurance test of reactivity control units for extended life times and the verification of structural integrity of those experimental facilities prior to loading in the HANARO. This test facility is composed of three major parts; a half-core structure assembly, flow circulation system and support system. The flow circulation system is composed of a circulation pump, a core flow pipe, a core bypass flow pipe and instruments. The system is to be filled with de-mineralized water and the flow should be met the design flow to simulate similar flow characteristics in the core channel of the half-core test facility to the HANARO. This paper, therefore, describes an analytical analysis to study the flow behavior of the system. The computational flow analysis has been performed for the verification of system pressure variation through the three-dimensional analysis program with standard k-$\epsilon$ turbulence model and for the verification of the structural piping integrity through the finite element method. The results of the analysis are satisfied the design requirements and structural piping integrity of flow circulation system.

  • PDF

초고온가스로 압력용기용 Gr. 91 강의 장시간 크리프 수명 예측 방법 개선 (Improvement of Long-term Creep Life Prediction Method of Gr. 91 steel for VHTR Pressure Vessel)

  • 박재영;김우곤;;김선진;김민환
    • 한국압력기기공학회 논문집
    • /
    • 제10권1호
    • /
    • pp.64-69
    • /
    • 2014
  • Gr. 91 steel is used for the major structural components of Generation-IV reactor systems, such as a very high temperature reactor(VHTR) and sodium-cooled fast reactor(SFR). Since these structures are designed for up to 60 years at elevated temperatures, the prediction of long-term creep life is important for a design application of Gr. 91 steel. In this study, a number of creep rupture data were collected through world-wide literature surveys, and using these data, the long-term creep life was predicted in terms of three methods: the single-C method in Larson-Miller(L-M) parameter, multi-C constant method in the L-M parameter, and a modified method("sinh" equation) in the L-M parameter. The results of the creep-life prediction were compared using the standard deviation of error value, respectively. Modified method proposed by the "sinh" equation revealed better agreement in creep life prediction than the single-C L-M method.

탄소강배관 다중 UT 측정두께를 활용한 감육여부 판별법 개발 (Development of Wall Thinning Distinction Method using the Multi-inspecting UT Data of Carbon Steel Piping)

  • 황경모;윤훈;이찬규
    • Corrosion Science and Technology
    • /
    • 제11권5호
    • /
    • pp.173-178
    • /
    • 2012
  • To manage the wall thinning of carbon steel piping in nuclear power plants, the utility of Korea has performed thickness inspection for some quantity of pipe components during refueling outages and determined whether repair or replacement after evaluating UT (Ultrasonic Test) data. When the existing UT data evaluation methods, such as Band, Blanket, PTP (Point to Point) Methods, are applied to a certain pipe component, unnecessary re-inspecting situations may be generated even though the component does not thinned. In those cases, economical loss caused by repeated inspection and problems of maintaining the pipe integrity followed by decreasing of newly inspected components may be generated. EPRI (Electric Power Research Institute) in USA has suggested several statistical methods, TPM (Total Point Method), LSS (Least Square Slope) Method, etc. to distinguish whether multiple inspecting components have thinned or not. This paper presents the analysis results for multiple inspecting components over three times based on both NAM (Near Area of Minimum) Method developed by KEPCO-E&C and the other methods suggested by EPRI.

3관식 시스템 히트펌프의 충전량 변화에 따른 성능 특성에 관한 연구 (The performance of a heat pump with 3-piping system at various charging conditions)

  • 송인식;최종민;주영주;정현준;강훈;김용찬
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.288-293
    • /
    • 2008
  • The cooling load in winter is significant in many commercial buildings and hotels because of the usage of office equipments and the high efficiency of wall insulation. The development of a multi-heat pump that can cover heating and cooling simultaneously for each indoor unit is required. In this study, the performance of a multi-heat pump with 3-piping system was investigated as a function of refrigerant charge and its performance was analyzed in cooling mode, heating mode, and heat recovery mode. COP in the heating or cooling mode showed little dependence on refrigerant charge at overcharge conditions, while those were strongly dependent on refrigerant charge at undercharge conditions and outdoor inlet temperature. In the heat recovery mode, the performance of the system was very sensitive to charge amount at all conditions. Optimum charge amount in the heat recovery mode was 14% lower than that in the cooling mode at the standard condition because the refrigerant only passed the indoor units. It is required to store the excessive refrigerant charge in a storage tank to optimize the system performance at operating modes.

  • PDF

노후 공동주택의 친환경적 개량화방안에 관한 주민의식 조사연구 (A Study of Residents' Consciousness on the Environmental Friendly Renovation of Deteriorated Multi-family Housing)

  • 이태구
    • 한국주거학회논문집
    • /
    • 제11권3호
    • /
    • pp.53-63
    • /
    • 2000
  • The purpose of this study is to improve design method for renovating an environmental friendly residential space where nature and humans could coexist. In the present study, five deteriorated multi-family housing complexes have been selected and one hundred and thirty eight dwellers have been asked about ecological important factors through the questionnaire. This study presents the adaptable solutions, such as are the enlargement of unit space or area, the renovation of facade, the functional change for dwellings on the ground level, the open piping of circulation systems, the expansion of community facilities(include greenarea), the build up of spatial hierarchy and the housing development set reuse planning forth as a premise, for the aspects of dwelling unit, building block and site planning.

  • PDF

AN INVESTIGATION OF SURFACE VORTICES BEHAVIOR IN PUMP SUMP

  • Kang, Won-Tae;Shin, Byeong-Rog
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2011년 춘계학술대회논문집
    • /
    • pp.592-595
    • /
    • 2011
  • A numerical investigation on a suction vortices, free vortices and subsurface vortices behavior in the model sump system with multi-intakes is performed A test model sump and piping system were designed based on Froude similitude for the prototype of the recommended structure layout by HI-9.B Standard for Pump Intake Design of the Hydraulic Institute. A numerical analysis of three dimensional multiphase flows through the model sump is performed by using the finite volume method of the CFX code with multi-block structured grid systems. A ${\kappa}-{\omega]$ ShearStressTransportturbulencemodelandthe Rayleigh-Plesset cavitation model are used for solving turbulence cavitating flow. From the numerical analysis, several types of vortices are reproduced and their formation, growing shedding and detailed vortex structures are investigated. To reduce abnormal vortices, an anti-vortex device is considered and its effect is investigated and discussed.

  • PDF