• 제목/요약/키워드: Multi-load Method

검색결과 625건 처리시간 0.025초

Development and Evaluation of Rollator for Elderly Farmers

  • Lee, Kyung Suk;Kim, Kyung Ran;Kim, Hyo Cher;Chae, Hye Seon;Kim, Sung Woo;Seo, Min Tae
    • 대한인간공학회지
    • /
    • 제33권6호
    • /
    • pp.487-497
    • /
    • 2014
  • Objective: This study aims to develop and evaluate a multi-purpose rollator, which may be used as a seat, as a traditional walker, or as a storage basket for elderly farmers. Background: The rollators on the market are not user-friendly designed and seen inconvenient for elderly farmers to use, although they are sold at considerably high price. Since they lack enough space to load stuffs and are not durable or stable enough, they do not seem to be suitable for elderly farmers to use in rural areas. Method: Two types of methods were used in this study. First, the survey consisted of 19 questions was conducted among elderly farmers in rural areas, after using the developed rollator, to evaluate the usability of the rollator developed in this study. Second, EMG experiment was conducted to compare the existing rollator and developed rollator quantitatively. Through this experiment, we tried to verify the differences of muscle responses, when using the traditional and the developed ones, which have their own brake system, in the ramp. Results: The developed rollator was highly evaluated in most of the questions in the usability survey, except for the 'Weight' category in which the opinions were divided into three different types (Worse: 31%, Similar: 30%, Better: 36%). The result of EMG experiment showed that the existing rollator (7.4%MVC) demands more muscle strength than the developed rollator (5.5%MVC) does. By statistically analyzing the results of upper limb and lower limb respectively, we found out that all the muscles except deltoid in upper limb showed statistically significant differences in muscle activity when using the existing and the developed rollator. However, there was no statistical difference in lower limb muscles. Conclusion: The developed rollator in this study has maximized the functionality of the brake system, the storage and the chair, which were pointed out as the weaknesses of existing rollators. Furthermore, the developed rollator is designed to be more user-friendly, safe, durable, and effective for elderly farmers to use in rural areas, where roads are rough and bumpy. Application: We expect that the emergency brake system developed in this study would be utilized for other convenience equipment, such as strollers and carts, and that it would be able to develop and produce more secure and reliable equipment in the future.

Cyclostorm : WAC 기반 모바일 앱의 자바스크립트 처리 효율 향상을 위한 클라우드 컴퓨팅 서비스 (Cyclostorm : The Cloud Computing Service for Uplifting Javascript Processing Efficiency of Mobile Applications based on WAC)

  • 방지웅;김대원
    • 전자공학회논문지
    • /
    • 제50권5호
    • /
    • pp.150-164
    • /
    • 2013
  • WAC (Wholesale Application Community) 기반 모바일 웹 애플리케이션의 보급이 널리 확산됨에 따라 자바스크립트와 HTML (Hyper Text Markup Language)로 구현된 애플리케이션의 처리 성능이 점차 이슈화되고 있다. 단순한 처리 기능만을 갖는 구조라면 현재 통용되는 브라우저에서도 문제가 없지만 자바스크립트의 처리량이 점점 증가 할수록 브라우저의 처리 부담 또한 가중된다. 현재 상용화 되어 있는 모바일 브라우저에서는 자바스크립트의 처리에 시간 및 용량의 제한을 두고 있다. 이러한 문제점의 해결을 위한 대안으로서 HTML 5에서는 기존의 자바스크립트에서는 지원하지 않는 멀티 스레드 구현을 위한 Web Worker를 제공하고 있다. Web Worker는 싱글 스레드에서 처리하는 일정 부분을 별도의 스레드를 통해서 처리하는 메커니즘을 제공한다. 하지만 이는 모바일상의 Native 애플리케이션만큼의 처리 능력을 보장하는 것이 아니며 근본적인 처리 속도 개선 방법으로는 미흡하다. Cyclostorm은 이러한 모바일 상에서의 자바스크립트 처리를 클라우드 상의 컴퓨터 서버에 이전함으로써 모바일 클라이언트로서의 자원적 한계를 극복하고 고성능 처리 서비스를 제공하여 Native 애플리케이션 만큼의 성능을 보장한다. 성능 평가 실험에서 Cyclostorm은 기존의 모바일 브라우저에서의 자바스크립트 처리보다 최대 6배 빠른 처리 속도를 보이고 있고 HTML 5의 Web Worker보다는 3~6배정도의 빠른 성능을 보이고 있다. 또한 메모리 부분에서도 서버 측에 존재하는 메모리를 사용하기 때문에 전반적으로 기존의 방법보다는 낮은 사용량이 측정 되었다. 본 논문에서는 현재 모바일 산업에서 화두가 되고 있는 WAC 기반에서 모바일 브라우저가 갖고 있는 한계를 극복하고 기존 웹 애플리케이션의 성능을 획기적으로 개선할 수 있는 클라우드 컴퓨팅 서비스인 Cyclostorm을 소개한다.

디바이스 ID 기반의 하이브리드 PKI 공인 인증 보안 기법 (Hybrid PKI Public Certificate Security Method Based on Device ID)

  • 손영환;최운수;김기현;최한나;이대윤;오충식;조용환
    • 한국컴퓨터정보학회논문지
    • /
    • 제15권5호
    • /
    • pp.113-124
    • /
    • 2010
  • 본 논문에서는 안전한 사용자 인증의 초석인 인증서의 원천지 무결성 보장과 함께 사용자의 편의성 향상을 위한 방안으로써, PKI 인증서 인증기법에 디바이스 ID에 기반한 하이브리드 공인 인증 기법을 제안하여 기존 하이브리드 PKI 공인인증서 인증기법에서의 사용자 편의성과 보안성을 향상시키고자 한다. 본 논문에서 제안하는 모델의 특징은 크게 다섯 가지로 설명할 수 있다. 첫째, 사용자 스스로 각각의 인증 상황 및 보안 수준에 맞는 정책을 선택 할 수 있어 사용자의 편의성을 향상 시킬 수 있다. 둘째, 정책별 디바이스 ID의 해시 값인 DLDI Key(Device Location Dependence ID Key)의 비교를 통해 사용자 인증서의 원천지 무결성을 보장할 수 있다. 셋째, EOTP Key(Event of One Time Password Key)를 통해서 인증서를 암호화, 복호화 하는 키의 값을 매 인증 시도마다 변경시킴으로써 보안성을 향상 시킬 수 있다. 넷째, 인증서에 Index 값을 추가시켜 멀티 디바이스에 인증서의 저장이 가능하다. 다섯째, 보안 카드 등 인증서의 원천지 무결성 보장을 위한 추가적인 장치가 필요치 않아, 인증 처리 시간의 지연을 단축시킬 수 있으며 인증 서버의 연산 부하를 감소시킬 수 있다.

말뚝지지 전면기초의 설계를 위한 실용적 해석방법에 관한 연구 (A Practical Analysis Method for the Design of Piled Raft Foundations)

  • 이승훈;박영호;송명준
    • 한국지반공학회논문집
    • /
    • 제23권12호
    • /
    • pp.83-94
    • /
    • 2007
  • 말뚝지지 전면기초는 말뚝기초를 경제적으로 설계할 수 있는 개념으로 주목을 받고 있으나, 전면기초, 말뚝, 지반간의 상호작용이 복잡하여 아직 국내에서 쉽게 실용화가 되고 있지 않은 실정이다. 저자들은 말뚝지지 전면기초의 실용화를 위해 필수적이라고 할 수 있는 효율적인 근사해석 프로그램을 개발하였으며, 본 논문에 그 내용을 간략하게 소개하였다. 개발된 프로그램에 적용된 해석모델은 크게 두 부분으로 구성되는데, 하나는 스프링 위에 놓인 유한요소의 기초판 해석모델이고, 다른 하나는 다층지반에 대하여 말뚝의 비선형성 및 상호작용의 영향을 고려할 수 있는 군말뚝 해석모델이다. 두 모델간의 적합조건을 만족시키기 위한 반복계산과정을 통해 지반과 말뚝의 강성을 구하여 말뚝지지 전면기초의 설계에 필요한 거동 예측결과를 얻을 수 있다. 해석기법의 검증을 위하여 정밀한 3차원 유한요소해석 및 기존에 개발된 근사해석방법들과의 비교분석을 수행하였으며, 이를 통해 개발된 프로그램이 기초요소간의 상호작용을 합리적으로 고려하면서도 비선형 해석이 가능하고 다층지반에 대한 적용성이 좋아 말뚝지지 전면기초의 해석 및 설계를 위한 실용적 목적에 잘 부합하는 성능을 갖는 것을 알 수 있었다.

설비공학 분야의 최근 연구 동향 : 2013년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2013)

  • 이대영;김사량;김현정;김동선;박준석;임병찬
    • 설비공학논문집
    • /
    • 제26권12호
    • /
    • pp.605-619
    • /
    • 2014
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2013. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and relative parts including orifices, dampers and ducts, fuel cells and power plants, cooling and air-conditioning, heat and mass transfer, two phase flow, and the flow around buildings and structures. Research issues dealing with home appliances, flows around buildings, nuclear power plant, and manufacturing processes are newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for general analytical model for desiccant wheels, the effects of water absorption on the thermal conductivity of insulation materials, thermal properties of Octadecane/xGnP shape-stabilized phase change materials and $CO_2$ and $CO_2$-Hydrate mixture, effect of ground source heat pump system, the heat flux meter location for the performance test of a refrigerator vacuum insulation panel, a parallel flow evaporator for a heat pump dryer, the condensation risk assessment of vacuum multi-layer glass and triple glass, optimization of a forced convection type PCM refrigeration module, surface temperature sensor using fluorescent nanoporous thin film. In the area of pool boiling and condensing heat transfer, researches on ammonia inside horizontal smooth small tube, R1234yf on various enhanced surfaces, HFC32/HFC152a on a plain surface, spray cooling up to critical heat flux on a low-fin enhanced surface were actively carried out. In the area of industrial heat exchangers, researches on a fin tube type adsorber, the mass-transfer kinetics of a fin-tube-type adsorption bed, fin-and-tube heat exchangers having sine wave fins and oval tubes, louvered fin heat exchanger were performed. (3) In the field of refrigeration, studies are categorized into three groups namely refrigeration cycle, refrigerant and modeling and control. In the category of refrigeration cycle, studies were focused on the enhancement or optimization of experimental or commercial systems including a R410a VRF(Various Refrigerant Flow) heat pump, a R134a 2-stage screw heat pump and a R134a double-heat source automotive air-conditioner system. In the category of refrigerant, studies were carried out for the application of alternative refrigerants or refrigeration technologies including $CO_2$ water heaters, a R1234yf automotive air-conditioner, a R436b water cooler and a thermoelectric refrigerator. In the category of modeling and control, theoretical and experimental studies were carried out to predict the performance of various thermal and control systems including the long-term energy analysis of a geo-thermal heat pump system coupled to cast-in-place energy piles, the dynamic simulation of a water heater-coupled hybrid heat pump and the numerical simulation of an integral optimum regulating controller for a system heat pump. (4) In building mechanical system research fields, twenty one studies were conducted to achieve effective design of the mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, and renewable energies in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment is mostly focused on indoor environment and building energy. The main researches of indoor environment are related to infiltration, ventilation, leak flow and airtightness performance in residential building. The subjects of building energy are worked on energy saving, operation method and optimum operation of building energy systems. The remained studies are related to the special facility such as cleanroom, internet data center and biosafety laboratory. water supply and drain system, defining standard input variables of BIM (Building Information Modeling) for facility management system, estimating capability and providing operation guidelines of subway station as shelter for refuge and evaluation of pollutant emissions from furniture-like products.