• Title/Summary/Keyword: Multi-level power inverter

Search Result 157, Processing Time 0.029 seconds

Configurations of High Power VSI Drives for Traction Applications Using Multi Level Inverters and Multi Phase Induction Motors (멀티레벨 인버터와 다상 유도기를 이용한 견인기용 대전력 VSI의 구조와 특성)

  • Gopakumnr, K.;Ryu, Hong-Je;Kim, Jong-Su;Im, Geun-Hui
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.500-504
    • /
    • 1997
  • Current source inverter drives of auto sequentially commutated type are very popular in high power applications, because of simple power circuit configuration with four quadrant operation. But the six-step current output create harmonic problems and the input power factor of such a drive is not always good. In this respect pulse width modulated drives using gate turn off thyristors ( GTO ) are finding application, especially in traction drives. However the switching and snubber loses of a GTO do not permit the inverter switching frequency go beyond a few hundred hertz.This will again introduce low frequency harmonic problems. Multi level inverters of the 3-level and 5-level can be considered as an alternative to overcome the low switching frequency harmonic problem of the 2-level GTO inverters. But with multi level inverters the complexity of the power circuit increases. In this paper a combination of multi level ( 2-level and 3-level ) inverters and multi phase induction motor ( 3-phase and 6-phase) configurations are presented for high power VSI drives for traction applications with reduced inverter switching frequency requirements coupled with reduced voltage rating for the power switch.

  • PDF

Implementation of a High Efficiency Grid-Tied Multi-Level Photovoltaic Power Conditioning System Using Phase Shifted H-Bridge Modules

  • Lee, Jong-Pil;Min, Byung-Duk;Yoo, Dong-Wook
    • Journal of Power Electronics
    • /
    • v.13 no.2
    • /
    • pp.296-303
    • /
    • 2013
  • This paper proposes a high efficiency three-phase cascaded phase shifted H-bridge multi-level inverter without DC/DC converters for grid-tied multi string photovoltaic (PV) applications. The cascaded H-bridge topology is suitable for PV applications since each PV module can act as a separate DC source for each cascaded H-bridge module. The proposed phase shifted H-bridge multi-level topology offers advantages such as operation at a lower switching frequency and a lower current ripple when compared to conventional two level topologies. It is also shown that low ripple sinusoidal current waveforms are generated with a unity power factor. The control algorithm permits the independent control of each DC link voltage with a maximum power point for each string of PV modules. The use of the controller area network (CAN) communication protocol for H-bridge multi-level inverters, along with localized PWM generation and PV voltage regulation are implemented. It is also shown that the expansion and modularization capabilities of the H-bridge modules are improved since the individual inverter modules operate more independently. The proposed topology is implemented for a three phase 240kW multi-level PV power conditioning system (PCS) which has 40kW H-bridge modules. The experimental results show that the proposed topology has good performance.

Harmonic Optimization Techniques in Multi-Level Voltage-Source Inverter with Unequal DC Sources

  • Aghdam, M. Ghasem Hosseini;Fathi, S. Hamid;Gharehpetian, Gevorg B.
    • Journal of Power Electronics
    • /
    • v.8 no.2
    • /
    • pp.171-180
    • /
    • 2008
  • One of the major problems in electric power quality is the harmonic contents. There are several methods of indicating the quantity of harmonic contents. The most widely used measure is the total harmonic distortion (THD). Various switching techniques have been used in static converters to reduce the output harmonic content. This paper presents and compares the two harmonic optimization techniques, known as optimal minimization of the total harmonic distortion (OMTHD) technique and optimized harmonic stepped-waveform (OHSW) technique used in multi-level inverters with unequal dc sources. Both techniques are very effective and efficient for improving the quality of the inverter output voltage. First, we describe briefly the cascaded H-bridge multi-level inverter structure. Then, we present the switching algorithm for the inverter based on OHSW and OMTHD techniques. Finally, the results obtained for the two techniques are analyzed and compared. The results verify the effectiveness of the both techniques in multi-level voltage-source inverter with non-equal dc sources, clarifying the advantages of each technique.

Multi-level PWM Inverter Considering the number of Output Voltage level and Current rating (출력전압 레벨 수와 전류정격을 고려한 PWM 다중레벨 인버터)

  • Park, N.S.;Seo, J.J.;Park, S.J.;Kim, K.H.;Cho, S.E.;Kim, C.U.
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.659-662
    • /
    • 2005
  • In this paper, we proposed the novel hybrid multi-level inverter using combination of the output voltage of transformers to reduce the THD(Total Harmonic Distortion) and improve the waveform of output voltage. The proposed multi-level inverter used the output of transformer which is 1times, 2times, 4times of input of the transformers. So we increased the output voltage from the reduce the number of switching component and transformer. Also, we tested the proposed prototype 15-level inverter to clarify the proposed electric circuit and reasonableness of control signal for the proposed multi -level PWM inverter.

  • PDF

3-Phase Transformer Isolated Multi-level Inverter Using Common Arm (공통암을 이용한 3상 변압기 절연 멀티레벨 인버터)

  • Song, Sung-Geun;Park, Sung-Jun;Kim, Dong-Ok;Lim, Young-Cheol;Kim, Kwang-Heon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.2
    • /
    • pp.149-156
    • /
    • 2007
  • The number of transformer and the size of transformer in inverter using 3-phase transformer could be reduced compare with a multi-level inverter using single phase transformer. but still the 3-phase transformer inverter needs many switches. In this study, we proposed the isolated multi-level inverter using 3-phase transformers and common arm, in this paper. Also, using phase angle control method with switching frequency equal to output fundamental frequency, harmonics component of output voltage and switching loss can be reduced. Finally, We tested multi-level inverter to clarify electric circuit md reasonableness through Matlab simulation and experiment by using prototype inverter.

Field Application of H-Bridge Multi-level Inverter for Fluidized Bed Combustion Boiler Secondary Air Fan (200MW 석탄화력 순환 유동층 보일러 이차공기송풍기용 H-브릿지 멀티레벨 인버터 현장적용)

  • Kim, Bong-Suck;Ryu, Ho-Seon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.5
    • /
    • pp.424-431
    • /
    • 2007
  • This thesis proposed H-Bridge Multi-Level Inverter for Fluidized Bed Combustion Boiler Secondary Air Fan in 200MW thermal power plant. The adjustable speed drive systems improve the efficiency in lightly load condition and extend the life span of motor by limiting the over current at starting. H-Bridge Multi-level Inverter is composed of the several series low voltage power cell inverters, which have the independent isolated do link, in each phase. KEPRI(Korea Electric Power Research Institute) has successfully completed to develop, install, and commission H-Bridge Multi-level Inverter(6.6kV, 1MVA). This thesis gives a full detail about H-Bridge Multi-level Inverter, proposed boiler DCS(Distributed Control System) logic, and commissioning test result.

Reliability Improvement of H-Bridge Multi-level Inverter for Medium-Voltage & High-Power Induction Motor Drives (고전압 대용량 유도전동기 구동용 H-브릿지 멀티레벨 인버터의 신뢰성 향상)

  • Park, Young-Min;Lee, Kwang-Hwan;Lee, Se-Hyun
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.2
    • /
    • pp.99-105
    • /
    • 2014
  • This paper proposes the reliability improvement of H-Bridge Multi-level (HBM) inverter. This reliability can be implemented through modularization of power circuit, distribution of controller, duplication of controller and communication, and continuous operation method in case of power cell failure for driving medium-voltage & high-power induction motor. It is shown that the modularization and expansion characteristics of the HBM inverter are improved since the individual inverter modules operate more independently when using the proposed concept. Also the fault tolerance is increased by using power cell bypass. The proposed design and control methods are described in detail and the validity of the proposed system is verified experimentally in various industrial fields.

Equivalent RMS Sine-wave Modulation of the Step-pulse type Multi-level Inverter (스텝펄스형 멀티레벨 인버터를 위한 RMS 등가형의 새로운 사인파 변조법)

  • Jin, Sun-Ho;Kwak, Jun-Ho;Jo, Kwan-Jun;Oh, Jin-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.3
    • /
    • pp.239-246
    • /
    • 2006
  • This paper suggests a new modulation strategy for step pulse type multi-level inverter. The proposed strategy is simple to determine the switching angles without regard to increase of levels. Designed to extract the equivalent RMS value compared to ideal sine wave from inverter, it can be applied effectively to high level step pulse inverter. Also this paper proposed modulation strategy for modified H-bridge 13 level inverter which has different cell source voltages with simulation and experiment. The modulation characteristics from simulation and experiment, agreed very well with tracing sine wave about modified structure of cascaded H-bridge multi-level inverter.

Isolated Multi-level Inverter Using 3-Phase Transformers (3상 변압기를 이용한 절연형 멀티레벨 인버터)

  • Kim, Tae-Jin;Park, Sung-Jun;Kim, Cheul-U;Song, Sung-Geun
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.2
    • /
    • pp.139-148
    • /
    • 2007
  • In this paper, we proposed the isolated multi-level inverter using 3-phase transformers. It makes possible to use a single DC power source due to employing low frequency transformers. In this inverter, the number of transformer could be reduced comparing with an exiting 3-phase multi-level inverter using single phase transformer. Also, using phase angle control method with switching frequency equal to output fundamental frequency, harmonics component of output voltage and switching losses can be reduced. Finally, we made a prototype inverter to clarify the proposed electric circuit and reasonableness of control signal.

HID Ballast using Soft Switching Multi Level Inverter (Soft Switching Multi Level Inverter를 이용한 HID용 Ballast)

  • Lee Jang-Sun;Kim Yoon-Ho;Kim Soo-Hong
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.6
    • /
    • pp.628-634
    • /
    • 2004
  • The soft switching is applied to the multi-level inverter to enhance the characteristics of HID(High Intensity Discharge) Ballast in headlight of vehicle. The electrical properties are investigated. The available modeling of the ballast in steady-state is calculated using mathematical method and the result is used in analyzing the power characteristics and design of the system. Finally the designed system md modeling is confirmed by the experiment.