• Title/Summary/Keyword: Multi-floor

Search Result 339, Processing Time 0.028 seconds

A Study on Interior Space Programming and spatial Cognition of the High-Speed Train station (고속철도 역사 실내공간 구성과 표현에 관한 연구)

  • 오인욱
    • Korean Institute of Interior Design Journal
    • /
    • no.18
    • /
    • pp.103-109
    • /
    • 1999
  • The purpose of this research is to suggest the ultimate solution to the interior elements and ways to express specific function within interior design of the new high-speed train station in Korea through careful studies based on the characteristics of each areas in the stations. During the research, it became very clear that the most important points in designing of the high speed train station's interior space can be found from close examination on whether each space allocation was thoughtfully organized to provide enough space to accommodate various activities of the users. Another point is to realize, within the space program, that there should be a clear understanding of the future expansion plan and reserving sufficient areas for the future growth. Also the problem of requiring larger floor areas to accommodate various functions divided by separate units must be recognized simultaneously during the programming. The new high-sped train must be able to function as a multi service facility of the future. In summary this research is to present datas and suggestion to various areas in the station and redefine its new meaning of train station space program with much borader concept which can be adopted to the process of better space programing.

  • PDF

Developing the Prediction Model for Color Design by the Image Types in the Office Interior (오피스 실내 색채계획을 위한 이미지별 예측모델 작성)

  • 진은미;이진숙
    • Korean Institute of Interior Design Journal
    • /
    • no.32
    • /
    • pp.97-104
    • /
    • 2002
  • The purpose of this study is to suggest the prediction model for the color design by the image types in the office interior. This prediction model of the color design is for the more comfortable environment by using suitable, various colors fitted with business functions. In this research, we carried out the evaluation experiment with the variables such as the color on ceiling, wall, floor and the harmonies of color schemes. We set the prediction index through the multi-regression analysis. And the prediction model was made by these results. The design methods by the prediction model are as follows. 1) The $\ulcorner$variable$\lrcorner$ image was deeply influenced by the value and chroma and it was marked high in low value and high chroma and the harmonies of contrast and different color. 2) The $\ulcorner$comfortable$\lrcorner$ image was related to the value and chroma and it was marked high in high value and low chroma and harmonies of homogeneity and similar. 3) The $\ulcorner$warm$\lrcorner$ image was greatly influenced by the hue and the harmony of color schemes, and it was marked high in the warm colors and harmonies of homogeneity.

Seismic response control of a building complex utilizing passive friction damper: Analytical study

  • Ng, C.L.;Xu, Y.L.
    • Structural Engineering and Mechanics
    • /
    • v.22 no.1
    • /
    • pp.85-105
    • /
    • 2006
  • Control of structural response due to seismic excitation in a manner of coupling adjacent buildings has been actively developed, and most attention focused on those buildings of similar height. However, with the rapid development of some modern cities, multi-story buildings constructed with an auxiliary low-rise podium structure to provide extra functions to the complex become a growing construction scheme. Being inspired by the positively examined coupling control approach for buildings with similar height, this paper aims to provide a comprehensive analytical study on control effectiveness of using friction dampers to link the two buildings with significant height difference to supplement the recent experimental investigation carried out by the writers. The analytical model of a coupled building system is first developed with passive friction dampers being modeled as Coulomb friction. To highlight potential advantage of coupling the main building and podium structure with control devices that provide a lower degree of coupling, the inherent demerit of rigid-coupled configuration is then evaluated. Extensive parametric studies are finally performed. The concerned parameters influencing the design of optimal friction force and control efficiency include variety of earthquake excitation and differences in floor mass, story number as well as number of dampers installed between the two buildings. In general, the feasibility of interaction control approach applied to the complex structure for vibration reduction due to seismic excitation is supported by positive results.

Dynamic properties of a building with viscous dampers in non-proportional arrangement

  • Suarez, Luis E.;Gaviria, Carlos A.
    • Structural Engineering and Mechanics
    • /
    • v.55 no.6
    • /
    • pp.1241-1260
    • /
    • 2015
  • Any rational approach to define the configuration and size of viscous fluid dampers in a structure should be based on the dynamic properties of the system with the dampers. In this paper we propose an alternative representation of the complex eigenvalues of multi degree of freedom systems with dampers to calculate new equivalent natural frequencies. Analytical expressions for the dynamic properties of a two-story building model with a linear viscous damper in the first floor (i.e. with a non-proportional damping matrix) are derived. The formulas permit to obtain the equivalent damping ratios and equivalent natural frequencies for all the modes as a function of the mass, stiffness and damping coefficient for underdamped and overdamped systems. It is shown that the commonly used formula to define the equivalent natural frequency is not applicable for this type of system and for others where the damping matrix is not proportional to the mass matrix, stiffness matrix or both. Moreover, the new expressions for the equivalent natural frequencies expose a novel phenomenon; the use of viscous fluid dampers can modify the vibration frequencies of the structure. The significance of the new equivalent natural frequencies is expounded by means of a simulated free vibration test. The proposed approach may offer a new perspective to study the effect of viscous dampers on the dynamic properties of a structure.

A Study on simulation analysis of the microbe transport of air-born virus in hospital for microbiological safety (미생물 안전을 위한 병원건물의 환기설계에 따른 공기 감염균 확산에 관한 시뮬레이션 연구)

  • Choi, Sang-Gon
    • Journal of the Korea Safety Management & Science
    • /
    • v.19 no.4
    • /
    • pp.115-123
    • /
    • 2017
  • Recently there is a growing interest in the airborne spread of virus. In particular, there is growing interest in secondary infection through the air in the hospital. The distribution of air-born virus depends on ventilation system installed in a hospital. In this study, simulations were carried out to predict the move of air-born virus by ventilation system at hospital. Simulation results showed that pressure distribution was -372.05Pa ~ -3.45 Pa at 1st floor incase of only used mechanical exhaust at bathroom, shower stall, storage, kitchen etc.. if ventilation switch from used mechanical exhaust to mechanical exhaust & mechanical supply. Simulation results showed that pressure distribution was -336.44Pa at stair hall < -0.2Pa at bathroom < mean 1.19Pa at other room. So simulation results showed that using all of the mechanical supply and mechanical exhaust was more effective then the mechanical exhaust for maintain the pressure distribution in hospital. It was also showed that when using the mechanical supply and mechanical exhaust more effectively prevention of air born virus diffusion.

Growth Characteristics of Juvenile Abalone, Haliotis discus hannai by Reared Methods in order to High Density Intermediate Culture in Land-based Tank (육성수조 내 북방전복, Haliotis discus hannai 치패 고밀도 중간양성 사육방식별 성장특성)

  • Lee, Si-Woo;Kim, Byeong-Hak;Park, Min-Woo;Kim, Tae-Ik;Son, Maeng-Hyun
    • The Korean Journal of Malacology
    • /
    • v.31 no.2
    • /
    • pp.83-92
    • /
    • 2015
  • The effect of different intermediated rearing method by expanding the attached floor space in order to highly density culture on the growth characteristics and survival rate of the juvenile abalone, Haliotis discus hannai, were investigated in land-based tanks. The intermediated culture methods was determined thru the shelter counts and layer for 10 month with two replicates : the single layer shelter (SLS), the double layer shelter (DLS), the triple layer shelter (TLS) and the single layer shelter under net cage (SLSNC). In addition, the culture on shallow race way tank had to set up as culture of the ditch raceway tank (CDRT) and the floor race way tank (CFRT). In the growth performance of reared abalone (initial mean shell length $54.18{\pm}7.39mm$ and weight $1.93{\pm}0.14g$) at experimental tanks, that the absolute growth rate (ARG), daily growth rate (DGR) and specific growth rate (SGR) to the shell length and shell breadth was not significant at each experimental tanks except SLSNC. As well as too, weight gain (WG), daily weight gain (DWG) and specific weight gain (SWG) to weight was not significant at each experimental tanks except SLSNC, too. Survival rates of CDRT and CFRT was lower than those of different experimental tanks (P < 0.05). Therefore, these results is showed that high density different intermediated rearing method by expanding the attached floor space for juvenile H. discus hannai was not have difference as growth performance and survival rate both one layer shelter and multi layer shelter. Also, it is considered that shallow race way tank was not useful rearing for the juvenile intermediate culture of H. discus hannai in land based.

Using Ridge Regression to Improve the Accuracy and Interpretation of the Hedonic Pricing Model : Focusing on apartments in Guro-gu, Seoul (능형회귀분석을 활용한 부동산 헤도닉 가격모형의 정확성 및 해석력 향상에 관한 연구 - 서울시 구로구 아파트를 대상으로 -)

  • Koo, Bonsang;Shin, Byungjin
    • Korean Journal of Construction Engineering and Management
    • /
    • v.16 no.5
    • /
    • pp.77-85
    • /
    • 2015
  • The Hedonic Pricing model is the predominant approach used today to model the effect of relevant factors on real estate prices. These factors include intrinsic elements of a property such as floor areas, number of rooms, and parking spaces. Also, The model also accounts for the impact of amenities or undesirable facilities of a property's value. In the latter case, euclidean distances are typically used as the parameter to represent the proximity and its impact on prices. However, in situations where multiple facilities exist, multi-colinearity may exist between these parameters, which can result in multi-regression models with erroneous coefficients. This research uses Variance Inflation Factors(VIF) and Ridge Regression to identify these errors and thus create more accurate and stable models. The techniques were applied to apartments in Guro-gu of Seoul, whose prices are impacted by subway stations as well as a public prison, a railway terminal and a digital complex. The VIF identified colinearity between variables representing the terminal and the digital complex as well as the latitudinal coordinates. The ridge regression showed the need to remove two of these variables. The case study demonstrated that the application of these techniques were critical in developing accurate and robust Hedonic Pricing models.

A Study on the Parking Space and Space of Detached Housing Area in Misagangbyeon-City (미사강변도시 단독주택지의 주차공간과 가구의 특성에 관한 연구)

  • Hwang, Yong-Woon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.10
    • /
    • pp.785-793
    • /
    • 2017
  • The guidelines for the district unit planning(DUP) of detached houses in the area of Misagangbyeon-City (MISA) do not consider the characteristics of the region. Therefore, this study was conducted to analyze the relationship between the blocks and parking lots of the detached houses area. The research results can be summarized as follows: 1) Detailed design guidelines are provided for apartment homes in MISA, but not for detached houses. 2) Apartment home and multi-family house parking lot equivaluation calculations exist in the DUP guidelines, however there are no regulations related to detached houses and the problem of parking for these residents is worsening which causes tension. 3) The DUP guidelines stipulate that the outer wall material of multi-family houses must be glass, however this is a dangerous material for use on the first floor, because cars that park close to this wall. 4) There is a significant risk to elementary and kindergarten students who must walk along the road in the inner blocks where cars are driving quickly. 5) There are a number of issues involved when planning parking lots without considering the characteristics of the area. The local government uses the traditional parking lot codes without considering the current regional characteristics, whereas the number of cars has dramatically increased. 6) The pedestrian mall is not currently being used for pedestrians, because it is full of parked cars due to the lack of parking space.

Material Characteristics and Deterioration Assessment for Multi-storied Round shape Stone Pagoda of Unjusa Temple, Hwasun, Korea (화순 운주사 원형다층석탑의 재질특성과 훼손도 평가)

  • Park, Sung Mi;Lee, Myeong Seong;Kim, Jae Hwan;Lee, Chan Hee
    • Korean Journal of Heritage: History & Science
    • /
    • v.45 no.1
    • /
    • pp.86-101
    • /
    • 2012
  • The constituting rocks of Multi-storied Round shape stone Pagoda of Unjusa Temple are lithic tuff and rhyolite tuff breaccia which show green or grey and also rock fragment with poor roundness are present in the structure. lithic tuff is composed of feldspar and quartz which are glassy texture and cryptocrystalline and also micro crystalline are scattered. phenocryst quartz and feldspar in the substrate composed of feldspar and opaque minerals are found in rhyolite tuff breaccia. dust, exfoliation, cavity, fracture and crack are observed in all the stone of the pagoda and the result of Infrared Thermography shows partial inter cavities have developed severely which may cause further exfoliation. In addition, a great deal of various grey, green, and yellow brown lichen as well as bryophyte are present at the upper part of eastern and western roof stone located above the third floor. Discolors remarkably shown at stereobate and roof stone are identified as inorganic pollutants such as manganese oxide, iron oxide and iron hydroxide. The stone of the pagoda of the Chemical Index of Alteration (CIA) and the Weathering Potential Index (WPI) are 55.69 and 1.12 respectively and this corresponds to a highly weathered stage. The measured values, average ultrasonic velocity 2,892m/s, coefficient of weathering 0.4k and compressive strength $1,096kg/cm^3$, suggest that the rock strength and durability are weakened.

Developing an Occupants Count Methodology in Buildings Using Virtual Lines of Interest in a Multi-Camera Network (다중 카메라 네트워크 가상의 관심선(Line of Interest)을 활용한 건물 내 재실자 인원 계수 방법론 개발)

  • Chun, Hwikyung;Park, Chanhyuk;Chi, Seokho;Roh, Myungil;Susilawati, Connie
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.43 no.5
    • /
    • pp.667-674
    • /
    • 2023
  • In the event of a disaster occurring within a building, the prompt and efficient evacuation and rescue of occupants within the building becomes the foremost priority to minimize casualties. For the purpose of such rescue operations, it is essential to ascertain the distribution of individuals within the building. Nevertheless, there is a primary dependence on accounts provided by pertinent individuals like building proprietors or security staff, alongside fundamental data encompassing floor dimensions and maximum capacity. Consequently, accurate determination of the number of occupants within the building holds paramount significance in reducing uncertainties at the site and facilitating effective rescue activities during the golden hour. This research introduces a methodology employing computer vision algorithms to count the number of occupants within distinct building locations based on images captured by installed multiple CCTV cameras. The counting methodology consists of three stages: (1) establishing virtual Lines of Interest (LOI) for each camera to construct a multi-camera network environment, (2) detecting and tracking people within the monitoring area using deep learning, and (3) aggregating counts across the multi-camera network. The proposed methodology was validated through experiments conducted in a five-story building with the average accurary of 89.9% and the average MAE of 0.178 and RMSE of 0.339, and the advantages of using multiple cameras for occupant counting were explained. This paper showed the potential of the proposed methodology for more effective and timely disaster management through common surveillance systems by providing prompt occupancy information.