• Title/Summary/Keyword: Multi-coupled

Search Result 739, Processing Time 0.098 seconds

Forging Die Design for Vent Forming of Square Cup Battery Case (사각 컵 배터리 케이스 바닥 벤트 성형을 위한 단조 금형 설계)

  • Lee, Sang-Hoon;Kwon, Soon-Ho;Chung, Hoon;Hong, Seokmoo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.6
    • /
    • pp.330-335
    • /
    • 2017
  • The demand for electric motor fuel cells has surged in the automotive industry, leading to a recent increase in the demand for square aluminum cans used as fuel cell battery casings. The air vent located on the bottom of the rectangular battery casing prevents large explosions by intermittent pressure release prior to the accumulation of abnormally high pressures. Conventionally, the square cup battery casing is produced via six-step deep drawing, with the outer shape of the vent being manufactured by welding to the square battery casing. On the other hand, this study directly incorporated the air vent outlet into the bottom surface of the rectangular casing. The product of a coupled finite element analysis technique applying the thickness and contour generated from the square cup multi-step deep drawing formation analysis was used as the forging input shape. The results yielded increased prediction accuracy and the advanced prediction of defects, such as swelling and fracture. Based on the results of the initial analyses, two of the generated forging shapes were determined to be suitable, with the optimal forging shape being determined by molding analysis. The results presented here were validated by mold fabrication and a subsequent comparison of the actual and analytical results.

An efficient approach for model updating of a large-scale cable-stayed bridge using ambient vibration measurements combined with a hybrid metaheuristic search algorithm

  • Hoa, Tran N.;Khatir, S.;De Roeck, G.;Long, Nguyen N.;Thanh, Bui T.;Wahab, M. Abdel
    • Smart Structures and Systems
    • /
    • v.25 no.4
    • /
    • pp.487-499
    • /
    • 2020
  • This paper proposes a novel approach to model updating for a large-scale cable-stayed bridge based on ambient vibration tests coupled with a hybrid metaheuristic search algorithm. Vibration measurements are carried out under excitation sources of passing vehicles and wind. Based on the measured structural dynamic characteristics, a finite element (FE) model is updated. For long-span bridges, ambient vibration test (AVT) is the most effective vibration testing technique because ambient excitation is freely available, whereas a forced vibration test (FVT) requires considerable efforts to install actuators such as shakers to produce measurable responses. Particle swarm optimization (PSO) is a famous metaheuristic algorithm applied successfully in numerous fields over the last decades. However, PSO has big drawbacks that may decrease its efficiency in tackling the optimization problems. A possible drawback of PSO is premature convergence leading to low convergence level, particularly in complicated multi-peak search issues. On the other hand, PSO not only depends crucially on the quality of initial populations, but also it is impossible to improve the quality of new generations. If the positions of initial particles are far from the global best, it may be difficult to seek the best solution. To overcome the drawbacks of PSO, we propose a hybrid algorithm combining GA with an improved PSO (HGAIPSO). Two striking characteristics of HGAIPSO are briefly described as follows: (1) because of possessing crossover and mutation operators, GA is applied to generate the initial elite populations and (2) those populations are then employed to seek the best solution based on the global search capacity of IPSO that can tackle the problem of premature convergence of PSO. The results show that HGAIPSO not only identifies uncertain parameters of the considered bridge accurately, but also outperforms than PSO, improved PSO (IPSO), and a combination of GA and PSO (HGAPSO) in terms of convergence level and accuracy.

Study of Hazard Materials in Yanggyeoksanhwa-tang by Decoction Method (전탕법이 양격산화탕(凉膈散火湯)의 위해물질에 미치는 연구)

  • Seo, Chang-Seob;Kim, Jung-Hoon;Ha, Hye-Kyoung;Lee, Mee-Young;Lee, Jun-Kyoung;Lee, Nam-Hun;Lee, Ho-Young;Lee, Jin-Ah;Lee, Sul-Lim;Shin, Hyeun-Kyoo
    • Journal of Sasang Constitutional Medicine
    • /
    • v.22 no.2
    • /
    • pp.93-100
    • /
    • 2010
  • 1. Objectives: To compare the contents of hazardous substances such as crude, washing solution, crude after washing, decoction and remnant. 2. Methods: The heavy metal contents of each step were measured by inductively coupled plasma (ICP) spectrometer and mercury analyzer (MA-2). In order to analyze pesticides in Yanggyeoksanhwa-tang we used simultaneous multi- residue analysis of pesticides by GC/ECD, which was followed by GC/MSD analysis to confirm the identity of the detected pesticide in each sample. In addition, the contents of sulfur dioxide (SO2) were performed by Monier-Williams distillation method. 3. Results: 1) The mean values of heavy metal contents (mg/kg) for each steps in Yanggeoksanhwa-tang were as follows: crude (Pb; 1.87, As; 1.29, Cd; 0.28 and Hg; N.D.), washing solution (Pb; 1.98, As; 1.13, Cd; 0.10 and Hg; N.D.), crude after washing (Pb; 1.90, As; 1.40, Cd; 0.22 and Hg; N.D.), decoction (Pb; 1.90, As; 1.14, Cd; 0.11 and Hg; N.D.) and remnant (Pb; 2.39, As; 1.29, Cd; 0.25 and Hg; 0.01). 2) Contents (mg/kg) of residual pesticides in crude and decoction were not detected. 3) Contents (mg/kg) of sulfur dioxide (SO2) in crude, crude after washing and remnant exhibited 3.00, 2.00 and 2.00 mg/kg, respectively. However, contents of sulfur dioxide in washing solution and decoction were not detected. 4. Conclusions: These Results: will be used to establish a criterion of heavy metals, residual pesticides and sulfur dioxide of each step in Yanggeoksanhwa-tang.

Intensity Compensation for Efficient Stereo Image Compression (효율적인 스테레오 영상 압축을 위한 밝기차 보상)

  • Jeon Youngtak;Jeon Byeungwoo
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.42 no.2 s.302
    • /
    • pp.101-112
    • /
    • 2005
  • As we perceive the world as 3-dimensional through our two eyes, we can extract 3-dimensional information from stereo images obtained from two or more cameras. Since stereo images have a large amount of data, with recent advances in digital video coding technology, efficient compression algorithms have been developed for stereo images. In order to compress stereo images and to obtain 3-D information such as depth, we find disparity vectors by using disparity estimation algorithm generally utilizing pixel differences between stereo pairs. However, it is not unusual to have stereo images having different intensity values for several reasons, such as incorrect control of the iris of each camera, disagreement of the foci of two cameras, orientation, position, and different characteristics of CCD (charge-coupled device) cameras, and so on. The intensity differences of stereo pairs often cause undesirable problems such as incorrect disparity vectors and consequent low coding efficiency. By compensating intensity differences between left and right images, we can obtain higher coding efficiency and hopefully reduce the perceptual burden of brain to combine different information incoming from two eyes. We propose several methods of intensity compensation such as local intensity compensation, global intensity compensation, and hierarchical intensity compensation as very simple and efficient preprocessing tool. Experimental results show that the proposed algerian provides significant improvement in coding efficiency.

Concentration of Heavy Metals, Residual Pesticides and Sulfur Dioxide of before/after a Decoction (전탕 전과 후의 중금속, 잔류농약 및 잔류이산화황의 농도변화 - 감기약을 중심으로 -)

  • Seo, Chang-Seob;Huang, Dae-Sun;Lee, Jun-Kyoung;Ha, Hye-Kyoung;Chun, Jin-Mi;Um, Young-Ran;Jang, Seol;Shin, Hyun-Kyoo
    • The Korea Journal of Herbology
    • /
    • v.23 no.4
    • /
    • pp.51-58
    • /
    • 2008
  • Objectives: To compare the contents of heavy metals, residual pesticides and sulfur dioxide before/after a decoction. Methods: The heavy metal contents before/after a decoction were measured by Inductively Coupled Plasma Atomic Emission Spectrometer(ICP-AES) and mercury analyzer. In order to analyze pesticides in 5 samples we used simultaneous multi-residue analysis of pesticides by GC/ECD, which was followed by GC/MSD analysis to confirm the identity of the detected pesticide in each sample. In addition, the contents of sulfur dioxide($SO_2$) were performed by Monier-Williams distillation method. Results: 1. The mean values of heavy metal contents(mg/kg) for the samples were as follows: Galgeun-tang(before decoction-Pb; 0.793, Cd; 0.133, As; 0.016 and Hg; 0.005, after decoction-Pb; 0.033, Cd; 0.004, As; 0.002 and Hg; not detected), Gumiganghwal-tang(before decoction-Pb; 0.934, Cd; 0.197, As; 0.046 and Hg; 0.006, after decoction-Pb; 0.062, Cd; 0.007, As; 0.004 and Hg; 0.0001), Sosiho-tang(before decoction-Pb; 0.891, Cd; 0.134, As; 0.091 and Hg; 0.014, after decoction-Pb; 0.036, Cd; 0.002, As; 0.004 and Hg; not detected), Ojuck-san(before decoction-Pb; 0.907, Cd; 0.136, As; 0.084 and Hg; 0.007, after decoction-Pb; 0.074, Cd; 0.007, As; 0.011 and Hg; 0.0005) and Samsoeum(before decoction-Pb; 1.234, Cd; 0.154, As; 0.016 and Hg; 0.007, after decoction-Pb; 0.094, Cd; 0.006, As; 0.002 and Hg; 0.001). 2. Contents(mg/kg) of residual pesticides before/after a decoction in all samples were not detected. 3. Contents(mg/kg) of sulfur dioxide($SO_2$) before a decoction in Galgeun-tang, Gumiganghwal-tang, Sosiho-tang, Ojuck-san and Samsoeum exhibited 1.2, 3.4, 11.1, 12.0 and 5.7, respectively. However, contents of sulfur dioxide after a decoction in all samples were not detected. Conclusions: These results will be used to establish a criterion of heavy metals, residual pesticides and sulfur dioxide.

  • PDF

The Effect of Barrel Vibration Intensity to the Plating Thickness Distribution

  • Lee, Jun-Ho;Roselle D. Llido
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 1999.10a
    • /
    • pp.15-15
    • /
    • 1999
  • In chip plating, several parameters must be taken into consideration. Current density, solution concentration, pH, solution temperature, components volume, chip and media ratio, barrel geometrical shape were most likely found to have an effect to the process yields. The 3 types of barrels utilized in chip plating industry are the conventional rotating barrel. vibrational barrel (vibarrel), and the centrifugal type. Conventional rotating barrel is a close type and is commonly used. The components inside the barrel are circulated by the barrel's rotation at a horizontal axis. Process yield has known to have higher thickness deviation. The vibrational barrel is an open type which offers a wide exposure to electrolyte resulting to a stable thickness deviation. It rotates in a vertical axis coupled with multi-vibration action to facilitate mixed up and easy transportation of components, The centrifugal barrel has its plated work centrifugally compacted against the cathode ring for superior electrical contact with simultaneous rotary motion. This experiment has determined the effect of barrel vibration intensity to the plating thickness distribution. The procedures carried out in the experiment involved the overall plating process., cleaning, rinse, Nickel plating, Tin-Lead plating. Plating time was adjusted to meet the required specification. All other parameters were maintained constant. Two trials were performed to confirm the consistency of the result. The thickness data of the experiment conducted showed that the average mean value obtained from higher vibrational intensity is nearer to the standard mean. The distribution curve shown has a narrower specification limits and it has a reduced variation around the target value, Generally, intensity control in vi-barrel facilitates mixed up and easy transportation of components, However, it is desirable to maintain an optimum vibration intensity to prevent solution intrusion into the chips' internal electrode. A cathodic reaction can occur in the interface of the external and internal electrode. $2HD{\;}+{\;}e{\;}{\rightarrow}20H{\;}+{\;}H_2$ Hydrogen can penetrate into the body and create pressure which can cause cracks. At high intensity, the chip's motion becomes stronger, its contact between each other is delayed and so plating action is being controlled. However, the strong impact created by its collision can damage the external electrode's structure thereby resulting to bad plating condition. 1 lot of chip was divided into two equal partion. Each portion was loaded to the same barrel one after the other. Nickel plating and tin-lead plating was performed in the same station. Portion A maintained the normal barrel vibration intensity and portion B vibration intensity was increased two steps higher. All other parameters, current, solution condition were maintained constant. Generally, plating method find procedures were carried out in a best way to maintained the best plating condition. After plating, samples were taken out from each portion. molded and polished. Plating thickness was investigated for both. To check consistency of results. 2nd trial was done now using different lot of another characteristics.

  • PDF

Concentration of Hazardous Substances of before/after a Decoction in Prescription of Herbal Medicine -In Prescription of tonify Yang and tonify Yin- (한방처방의 전탕 전과 후의 위해물질 농도변화 -보양.보음 처방을 중심으로 -)

  • Seo, Chang-Seob;Huang, Dae-Sun;Lee, Jun-Kyoung;Ha, Hye-Kyoung;Chun, Jin-Mi;Um, Young-Ran;Jang, Seol;Shin, Hyeun-Kyoo
    • Herbal Formula Science
    • /
    • v.17 no.2
    • /
    • pp.53-63
    • /
    • 2009
  • Objective : To compare the contents of heavy metals, residual pesticides and sulfur dioxide before/after a decoction. Methods : The heavy metal contents before/after a decoction were measured by Inductively Coupled Plasma Atomic Emission Spectrometer (ICP-AES) and mercury analyzer. In order to analyze pesticides in 4 samples we used simultaneous multi-residue analysis of pesticides by GC/ECD, which was followed by GC/MSD analysis to confirm the identity of the detected pesticide in each sample. In addition, the contents of sulfur dioxide ($SO_2$) were performed by Monier-Williams distillation method. Results: 1. The mean values of heavy metal contents (mg/kg) for the samples were as follows: Jaeumganghwa-tang (before decoction - Pb; 1.190, Cd; 0.184, As; 0.099 and Hg; 0.028, after decoction - Pb; .033, Cd; 0.003, As; 0.005 and Hg; 0.001), Yukmijiwhang-tang (before decoction - Pb; 0.484, Cd; 0.133, As; 0.053 and Hg; 0.009, after decoction - Pb; 0.065, Cd; 0.008, As; 0.007 and Hg; not detected), Bojungikgi-tang (before decoction - Pb; 0.863, Cd; 0.197, As; below 0.016 and Hg; 0.011, after decoction - Pb; 0.071, Cd; 0.009, As; 0.004 and Hg; 0.001) and Ssangwha-tang (before decoction - Pb; 1.511, Cd; 0.212, As; 0.094 and Hg; 0.016, after decoction - Pb; 0.029, Cd; 0.006, As; 0.005 and Hg; 0.0004). 2. Contents (mg/kg) of sulfur dioxide ($SO_2$) before a decoction in Jaeumganghwa-tang, Yukmijiwhang-tang and Ssangwha-tang exhibited 22.7, 107.3 and 5.5, respectively. However, contents of sulfur dioxide after a decoction in all samples were not detected. 3. Contents (mg/kg) of residual pesticides before/after a decoction in all samples were not detected. Conclusion : These results will be used to establish a criterion of heavy metals, residual pesticides and sulfur dioxide.

  • PDF

Concentration of Heavy Metals, Residual Pesticides and Sulfur Dioxide before/after a Decoction - In Prescription consist of Sipjeondaebo-tang - (전탕 전과 후의 중금속, 잔류농약 및 잔류이산화황의 농도변화 - 십전대보탕 구성처방을 중심으로 -)

  • Seo, Chang-Seob;Huang, Dae-Sun;Lee, Jun-Kyoung;Ha, Hye-Kyung;Chun, Jin-Mi;Um, Young-Ran;Jang, Seol;Shin, Hyeun-Kyoo
    • The Journal of Korean Medicine
    • /
    • v.30 no.4
    • /
    • pp.108-117
    • /
    • 2009
  • Objective: To compare the contents of heavy metals, residual pesticides and sulfur dioxide before/after a decoction. Methods: The heavy metal contents before/after a decoction were measured by inductively-coupled plasma atomic emission spectrometer (ICP-AES) and mercury analyzer. In order to analyze pesticides in 5 samples we used simultaneous multi-residue analysis of pesticides by GC/ECD, which was followed by GC/MSD analysis to confirm the identity of the detected pesticide in each sample. In addition, the contents of sulfur dioxide ($SO_2$) were performed by Monier-Williams distillation method. Results: 1. The mean values of heavy metal contents (mg/kg) for the samples were as follows: Sipjeondaebo-tang (before decoction - Pb; 1.163, Cd; 0.257, As; 0.080 and Hg; 0.016, after decoction - Pb; 0.059, Cd; 0.007, As; 0.006 and Hg; 0.0003), Palmul-tang (before decoction - Pb; 1.181, Cd; 0.242, As; 0.152 and Hg; 0.014, after decoction - Pb; 0.067, Cd; 0.008, As; 0.008 and Hg; 0.0003), Sagunja-tang (before decoction - Pb; 1.285, Cd; 0.283, As; 0.063 and Hg; 0.012, after decoction - Pb; 0.047, Cd; 0.009, As; 0.004 and Hg; not detected) and Samul-tang (before decoction - Pb; 1.025, Cd; 0.169, As; 0.099 and Hg; 0.013, after decoction - Pb; 0.065, Cd; 0.007, As; 0.010 and Hg; 0.001). 2. Contents (mg/kg) of residual pesticides before/after a decoction were not detected in any samples. 3. Contents (mg/kg) of sulfur dioxide ($SO_2$) before a decoction in Sipjeondaebo-tang, Palmul-tang, Sagunja-tang and Samul-tang exhibited 5.0, 6.0, 14.0 and 6.9, respectively. However, contents of sulfur dioxide after a decoction were not detected in any samples. Conclusion: These results will be used to establish a criterion for heavy metals, residual pesticides and sulfur dioxide.

  • PDF

Aeroelastic Tailoring of a Forward-Swept Wing Using One-dimensional Beam Analysis (1차원 보 해석을 활용한 전진익 항공기의 복합적층 날개 공력탄성학적 테일러링)

  • Choi, JaeWon;Lim, ByeongUk;Lee, SiHun;Shin, SangJoon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.48 no.8
    • /
    • pp.555-563
    • /
    • 2020
  • Foward-swept wings are known to possess superior aerodynamic performance compared to the conventional straight wings. However major concerns regarding forward-swept wings include divergence at lower airspeeds which require careful consideration at the design stage. As an endeavor to overcome such drawbacks, aeroelastic tailoring is attempted. In order to find an optimal ply sequence, recursive aeroelastic analyses is conducted and one-dimensional beam analysis coupled with simple aerodynamics is used for the improved computational efficiency and modelling convenience. The analysis used in this paper, DYMORE and analytic formula, both use one-dimensional beam model for the structure. Cross-sectional analysis for multi-cell NACA0015 airfoil section is conducted using VABS and oblique function is used for the sweep angle. Throughout the present aeroelastic tailoring, the maximum divergence speed of 290.2m/s is achieved which is increased by approximately 43% than that for the conventional ply configuration.

Utility of Integrated Analysis of Pharmacogenomics and Pharmacometabolomics in Early Phase Clinical Trial: A Case Study of a New Molecular Entity

  • Oh, Jaeseong;Yi, Sojeong;Gu, Namyi;Shin, Dongseong;Yu, Kyung-Sang;Yoon, Seo Hyun;Cho, Joo-Youn;Jang, In-Jin
    • Genomics & Informatics
    • /
    • v.16 no.3
    • /
    • pp.52-58
    • /
    • 2018
  • In this report, we present a case study of how pharmacogenomics and pharmacometabolomics can be useful to characterize safety and pharmacokinetic profiles in early phase new drug development clinical trials. During conducting a first-in-human trial for a new molecular entity, we were able to determine the mechanism of dichotomized variability in plasma drug concentrations, which appeared closely related to adverse drug reactions (ADRs) through integrated omics analysis. The pharmacogenomics screening was performed from whole blood samples using the Affymetrix DMET (Drug-Metabolizing Enzymes and Transporters) Plus microarray, and confirmation of genetic variants was performed using real-time polymerase chain reaction. Metabolomics profiling was performed from plasma samples using liquid chromatography coupled with quadrupole time-of-flight mass spectrometry. A GSTM1 null polymorphism was identified in pharmacogenomics test and the drug concentrations was higher in GSTM1 null subjects than GSTM1 functional subjects. The apparent drug clearance was 13-fold lower in GSTM1 null subjects than GSTM1 functional subjects (p < 0.001). By metabolomics analysis, we identified that the study drug was metabolized by cysteinylglycine conjugation in GSTM functional subjects but those not in GSTM1 null subjects. The incidence rate and the severity of ADRs were higher in the GSTM1 null subjects than the GSTM1 functional subjects. Through the integrated omics analysis, we could understand the mechanism of inter-individual variability in drug exposure and in adverse response. In conclusion, integrated multi-omics analysis can be useful for elucidating the various characteristics of new drug candidates in early phase clinical trials.