• 제목/요약/키워드: Multi-coupled

검색결과 733건 처리시간 0.028초

On-line Generation of Three-Dimensional Core Power Distribution Using Incore Detector Signals to Monitor Safety Limits

  • Jang, Jin-Wook;Lee, Ki-Bog;Na, Man-Gyun;Lee, Yoon-Joon
    • Nuclear Engineering and Technology
    • /
    • 제36권6호
    • /
    • pp.528-539
    • /
    • 2004
  • It is essential in commercial reactors that the safety limits imposed on the fuel pellets and fuel clad barriers, such as the linear power density (LPD) and the departure from nucleate boiling ratio (DNBR), are not violated during reactor operations. In order to accurately monitor the safety limits of current reactor states, a detailed three-dimensional (3D) core power distribution should be estimated from the in-core detector signals. In this paper, we propose a calculation methodology for detailed 3D core power distribution, using in-core detector signals and core monitoring constants such as the 3D Coupling Coefficients (3DCC), node power fraction, and pin-to-node factors. Also, the calculation method for several core safety parameters is introduced. The core monitoring constants for the real core state are promptly provided by the core design code and on-line MASTER (Multi-purpose Analyzer for Static and Transient Effects of Reactors), coupled with the core monitoring program. through the plant computer, core state variables, which include reactor thermal power, control rod bank position, boron concentration, inlet moderator temperature, and flow rate, are supplied as input data for MASTER. MASTER performs the core calculation based on the neutron balance equation and generates several core monitoring constants corresponding to the real core state in addition to the expected core power distribution. The accuracy of the developed method is verified through a comparison with the current CECOR method. Because in all the verification calculation cases the proposed method shows a more conservative value than the best estimated value and a less conservative one than the current CECOR and COLSS methods, it is also confirmed that this method secures a greater operating margin through the simulation of the YGN-3 Cycle-1 core from the viewpoint of the power peaking factor for the LPD and the pseudo hot pin axial power distribution for the DNBR calculation.

MIMO-OFDM에서 효율적인 채널 추적 방식 (An Efficient Channel Tracking Method in MIMO-OFDM Systems)

  • 전형구;김경수;안지환
    • 한국통신학회논문지
    • /
    • 제33권3A호
    • /
    • pp.256-268
    • /
    • 2008
  • 본 논문에서는 다중 경로 레이리 페이딩 시변 채널 환경의 Multiple Input Multiple Output-Orthogonal Frequency Division Multiplexing (MIMO-OFDM) 시스템에서 효율적으로 채널 변화를 추적할 수 있는 채널 추적방식을 제안하였다. 제안된 방식은 시변 채널에 대응할 수 있도록 블라인드 채널 예측기를 설계하였다. 또한 주파수 영역 채널 추정이 Minimum Mean Square Error (MMSE) 시간영역 채널 추정과 결합되어 있으며 이 방식은 매 OFDM 심벌마다 역행렬을 계산할 필요가 없다는 장점이 있다. 컴퓨터 시뮬레이션 결과 제안된 방식은 기존의 Li방식[4] 보다 성능이 우수함을 보였다. 도플러 주파수 100Hz 및 10-4 BER에서 Eb/No이득이 약 2.5 dB 정도 되었다. 도플러 주파수가 200Hz일 때 그 성능의 차이는 더욱 커졌다.

냉난방 가동 모사에 따른 콘크리트 에너지파일의 열응력 해석에 대한 연구 (Study on Thermal Stress Occurred in Concrete Energy Pile During Heating and Cooling Buildings)

  • 성치훈;박상우;김병연;정경식;최항석
    • 한국지열·수열에너지학회논문집
    • /
    • 제11권2호
    • /
    • pp.12-18
    • /
    • 2015
  • The energy pile, used for both structural foundations and heat exchangers, brings about heat exchange with the ground formation by circulating a working fluid for heating and cooling buildings. As heat exchange occurs in the energy pile, thermal stress and strain is generated in the pile body and surrounding ground formation. In order to investigate the thermo-mechanical behavior of an energy pile, a comprehensive experimental program was conducted, monitoring the thermal stress of a cast-in place energy pile equipped with five pairs of U-type heat exchanger pipes. The heating and cooling simulation both continued for 30 days. The thermal strain in the longitudinal direction of the energy pile was monitored for a 15 operation days and another 15 days monitoring followed, without the application of heat exchange. In addition, a finite element model was developed to simulate the thermo-mechanical behavior of the energy pile. A non-linear contact model was adopted to interpret the interaction at the pile-soil interface, and thermal-induced structure mechanics was considered to handle the thermo-mechanical coupled multi-field problem.

UMTS와 WLAN 사이의 소프트 핸드오버 방안 (A Soft Handover Scheme Between UMTS and WLAN)

  • 서원경;이강원;조유제
    • 한국통신학회논문지
    • /
    • 제33권5B호
    • /
    • pp.268-274
    • /
    • 2008
  • 최근 무선 통신 기술의 급격한 발달로 언제, 어디서나, 지속적인 서비스를 이용하고j라 사용자들의 요구가 급증하고 있다. 이를 위해서 서로 다른 무선 접속망을 동일 시스템처럼 통합하는 기술과 하나의 단말이 다양한 무선 접속망을 이용할 수 있는 다중 인터페이스 단말 기술, 통신 가입자의 서로 이종 무선 접속망간 이동에도 지속적인 서비스를 제공하기 위한 수직적 핸드오버 기술이 필요하다. 현재 차세대 네트워크를 위한 이종 접속망 연동연구는 서로 다른 접속망이 인터넷으로 연동되는 loosely 연동 구조와 하나의 접속망 내에 다른 접속망이 연동되는 tightly 연동 구조를 바탕으로 진행되고 있으며, 이종 접속망간 이동성 지원 기술은 주로 loosely 연동 구조에서 Mobile IP를 확장하는 방향으로 연구되고 있다. Tightly 연동 구조는 서로 다른 무선 접속망이 밀접하게 연동되어 좀 더 신속한 핸드오버를 제공할 수 있지만 연동이 복잡하기 때문에 아직까지 구체적인 이동성 관리 방안없이 개념적인 방향만 제시하고 있는 실정이다. 따라서 본 논문에서는 UMTS와 WLAN 연동 구조를 정의하고, 다중 인터페이스 단말을 이용한 소프트 수직적 핸드오버 시그널링 절차를 제안한다. 또한 OPNET 시뮬레이터를 통해 제안된 수직적 핸드오버 방안이 끊김없는 서비스를 제공할 수 있음을 확인하였다.

Electroplating process for the chip component external electrode

  • Lee, Jun-Ho
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2000년도 추계학술발표회 초록집
    • /
    • pp.1-2
    • /
    • 2000
  • In chip plating, several parameters must be taken into consideration. Current density, solution concentration, pH, solution temperature, components volume, chip and media ratio, barrel geometrical shape were most likely found to have an effect to the process yields. The 3 types of barrels utilized in chip plating industry are the onventional rotating barrel, vibrational barrel(vibarrel), and the centrifugal type. Conventional rotating barrel is a close type and is commonly used. The components inside the barrel are circulated by the barrel's rotation at a horizontal axis. Process yield has known to have higher thickness deviation. The vibrational barrel is an open type which offers a wide exposure to electrolyte resulting to a stable thickness deviation. It rotates in a vertical axis coupled with multi-vibration action to facilitate mixed up and easy transportation of components. The centrifugal barrel has its plated work centrifugally compacted against the cathode ring for superior electrical contact with simultaneous rotary motion. This experiment has determined the effect of barrel vibration intensity to the plating thickness distribution. The procedures carried out in the experiment involved the overall plating process., cleaning, rinse, Nickel plating, Tin-Lead plating. Plating time was adjusted to meet the required specification. All other parameters were maintained constant. Two trials were performed to confirm the consistency of the result. The thickness data of the experiment conducted showed thatbthe average mean value obtained from higher vibrational intensity is nearer to the standard mean. The distribution curve shown has a narrower specification limits and it has a reduced variation around the target value. Generally, intensity control in vi-barrel facilitates mixed up and easy transportation of components. However, it is desirable to maintain an optimum vibration intensity to prevent solution intrusion into the chips' internal electrode. A cathodic reaction can occur in the interface of the external and internal electrode. 2H20 + e $\rightarrow$M/TEX> 20H + H2.. Hydrogen can penetrate into the body and create pressure which can cause cracks. At high intensity, the chip's motion becomes stronger, its contact between each other is delayed and so plating action is being controlled. However, the strong impact created by its collision can damage the external electrode's structure there by resulting to bad plating condition.

  • PDF

액체크로마토그래프-질량분석기를 이용한 정성 및 정량 오류의 확인 (Identification of Pitfalls Related to the Analysis of Liquid Chromatography-Tandem Mass Spectrometry and Liquid Chromatography-Time of Flight Mass Spectrometry)

  • 권진욱;조윤제;이규식
    • 한국환경농학회지
    • /
    • 제34권3호
    • /
    • pp.230-237
    • /
    • 2015
  • BACKGROUND: To identify the sources of inaccuracy in LC/MS/MS methods used in the routine quantitation of small molecules are described and discussed. METHODS AND RESULTS: Various UPLC coupled to triple quadrupole mass spectrometer and time of flight (TOF) were used to identify the potential sources of inaccuracy and inducing the pitfalls of qualification and quntitation during the veterinary drug residue analysis. Some of stable isotope labelled veterinary drugs, which were used as internal standards, presented "cross-talk", regardless of manufactures of mass spectrometer and types of spectrometer. Group of sulfonamides also presented inaccuracy qualification and quantitation due to the multi-residue analytical method with the same fragment ions at the close retention times. CONCLUSION: The phenomena of "cross-talk" occurring between subsequently monitored transition from stable isotope labelled and isotope non-labelled authentic chemical were identified. To prevent errors and achieve more accurate data during the analysis of small molecules by LC/MS/MS SRM method, Followings should be taken care of and kept checking; purity and concentration of stable isotope as an internal standard, prevention of carry-over during the separation in column, minimizing the ion suppression by matrix effect, identification of retention time, precursor ion and product ion, and full knowledge of data processing including smoothing and peak integration.

솔라셀용 uC-Si:H 박막 증착공정을 위한 플라즈마 소스에 대한 고찰 및 multi-hole hollow cathode CCP에 대한 연구

  • 서상훈;이헌수;이윤성;장홍영
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2009년도 제38회 동계학술대회 초록집
    • /
    • pp.409-409
    • /
    • 2010
  • 솔라셀은 차세대 대체 에너지 소스로 최근 큰 각광을 받고 있다. 솔라셀의 제조에 있어 가장 중요한 공정은 마이크로 결정질 및 비결정질 실리콘(uC-Si:H and a-Si:H) 박막을 증착하는 PECVD (Plasma Enhanced CVD)공정이다. 현재까지 이 증착공정을 위한 플라즈마 소스로 CCP(Capacitively Coupled Plasma)가 주로 사용되어 왔다. 그러나, CCP를 플라즈마 소스를 사용한 경우 솔라셀 대량 생산 적용시 다른 방법들에 비해 긴 공정 시간이 해결해야 할 문제점으로 대두되었다. 본 발표에서는 솔라셀의 대량 생산을 위한 마이크로 결정질 실리콘 박막 증착에 있어 현 시점에서 해결되어야 할 문제점에 대해 고찰해 보고자 한다. 현재까지 이러한 문제점들을 해결하기 위해 적용되어 왔던 플라즈마 소스들을 나열하고 이러한 플라즈마 소스에 대한 특성 및 문제점들을 고찰한다. 또한, PECVD 공정상의 문제점을 해결하기 위한 플라즈마 조건을 플라즈마 벌크에서의 전자에너지 분포를 기준으로 제시하고자 한다. 솔라셀용 결정질 실리콘 박막 증착용 플라즈마 소스로 hollow cathode 방전이 가장 유력시되고 있다. 본 연구에서는 CCP 플라즈마에서 hollow cathode 방전시 발생되는 플라즈마 특성에 대한 기초 연구를 제시한다. 기초 연구를 위해 다양한 불활성 가스인 아르콘, 헬륨, 크립톤 가스에 13.56 MHz의 RF 파워를 인가하고 방전되는 플라즈마 밀도 변화를 관찰하였다. 특히, 다양한 hole diameter에서 발생되는 플라즈마 밀도의 변화를 기존 평면 CCP 플라즈마의 밀도에 비교하여 분석함으로써 hole diameter에 따른 효과를 관찰하였다. 이러한 결과는 PIC 시뮬레이션을 통해 얻은 전자에너지 분포함수를 바탕으로 메커니즘을 논의하고자 한다. 마지막으로 솔라셀용 PECVD공정을 위해 고밀도 플라즈마 소스의 필요성뿐 만 아니라 대면적 소스의 구현에 대한 문제점을 고찰하였다. 대면적 공정에서 가장 중요한 핵심 연구 이슈는 공정 균일도를 높이는 것이다. CCP 플라즈마 소스에서 전극의 크기가 대면적화 됨에 따라 발생되는 전자기파 효과에 의한 불균일도에 대해 RF 전자기장 시뮬레이션을 통해 확인하고, 균일도 확보를 위한 방안에 대한 논의하고자 한다.

  • PDF

Microtensile bond strength of silorane-based composite specific adhesive system using different bonding strategies

  • Bastos, Laura Alves;Sousa, Ana Beatriz Silva;Drubi-Filho, Brahim;Pires-de-Souza, Fernanda de Carvalho Panzeri;Garcia, Lucas da Fonseca Roberti
    • Restorative Dentistry and Endodontics
    • /
    • 제40권1호
    • /
    • pp.23-29
    • /
    • 2015
  • Objectives: The aim of this study was to evaluate the effect of pre-etching on the bond strength of silorane-based composite specific adhesive system to dentin. Materials and Methods: Thirty human molars were randomly divided into 5 groups according to the different bonding strategies. For teeth restored with silorane-based composite (Filtek Silorane, 3M ESPE), the specific self-etching adhesive system (Adhesive System P90, 3M ESPE) was used with and without pre-etching (Pre-etching/Silorane and Silorane groups). Teeth restored with methacrylate based-composite (Filtek Z250, 3M ESPE) were hybridized with the two-step self-etching system (Clearfil SE Bond, Kuraray), with and without pre-etching (Pre-etching/Methacrylate and Methacrylate groups), or three-step adhesive system (Adper Scotchbond Multi-Purpose, 3M ESPE) (Three-step/Methacrylate group) (n = 6). The restored teeth were sectioned into stick-shaped test specimens ($1.0{\times}1.0mm$), and coupled to a universal test machine (0.5 mm/min) to perform microtensile testing. Results: Pre-etching/Methacrylate group presented the highest bond strength values, with significant difference from Silorane and Three-step/Methacrylate groups (p < 0.05). However, it was not significantly different from Pre-etching/Silorane and Methacrylate groups. Conclusions: Pre-etching increased bond strength of silorane-based composite specific adhesive system to dentin.

하이브리드 병렬화 기반 초고해상도 1D-2D 도시침수 모의 (Hyper-resolution 1D-2D coupled urban inundation modelling using LiDAR and hybrid parallelization)

  • 이승수;노성진;이준학;카와이케 켄지;서동준
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2018년도 학술발표회
    • /
    • pp.7-7
    • /
    • 2018
  • 1차원 하수관로 해석 모형과 2차원 지표면 유출 해석 모형을 연계한 1D-2D 결합 도시침수 모델은 도시지역의 유출 현상과 침수 모의에 널리 이용되고 있다. 그러나 도시 지역의 복잡한 지형이 지표면 유출 흐름에 미치는 영향을 보다 자세히 파악하기 위해서는 보다 높은 해상도의 지형자료를 활용한 모의가 필요하다. 본 연구에서는 도시침수 해석을 위한 1D-2D 결합 하이브리드(Hybrid) 병렬화 코드(H12)를 개발하여 넓은 도시 유역에 대해서 고해상도 지형자료를 활용한 모의가 유역단위로 가능하도록 하였다. H12는 Open Multi-Processing(OpenMP)와 Message Passing Interface(MPI) 병렬 계산을 동시에 수행하여 매우 넓은 지역에 대해서도 도로의 형태를 확인 할 수 있는 수준의 고해상도 침수 해석 모의가 가능하다. 또한 도시지역의 복잡한 지형을 자세히 재현하고 계산의 효율을 높이기 위하여 격자세분화 기법이 적용되었다. H12의 적용성을 평가하기 위하여 미국 텍사스 알링턴 지역의 Johnson Creek 유역(${\sim}40km^2$)유역에 대한 시범 모의를 수행하였으며 도시유역의 지형을 표현하기 위하여 1m 해상도의 LiDAR자료를 사용하여 침수발생시 보다 자세한 유출수의 흐름을 해석할 수 있도록 하였다. 모의 결과 하이브리드 병렬 계산은 순차적 계산에 비하여 최고 79배 이상 빠른 계산속도 효율 향상을 보여주었으며, OpenMP나 MPI를 단독으로 사용하는 것에 비하여 더욱 효율적인 계산속도 효율 향상을 보여주었다.

  • PDF

다양한 지구통계기법의 지하매질 예측능 및 적용성 비교연구 (Comparative Analysis of Subsurface Estimation Ability and Applicability Based on Various Geostatistical Model)

  • 안정우;정진아;박은규
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제19권4호
    • /
    • pp.31-44
    • /
    • 2014
  • In the present study, a few of recently developed geostatistical models are comparatively studied. The models are two-point statistics based sequential indicator simulation (SISIM) and generalized coupled Markov chain (GCMC), multi-point statistics single normal equation simulation (SNESIM), and object based model of FLUVSIM (fluvial simulation) that predicts structures of target object from the provided geometric information. Out of the models, SNESIM and FLUVSIM require additional information other than conditioning data such as training map and geometry, respectively, which generally claim demanding additional resources. For the comparative studies, three-dimensional fluvial reservoir model is developed considering the genetic information and the samples, as input data for the models, are acquired by mimicking realistic sampling (i.e. random sampling). For SNESIM and FLUVSIM, additional training map and the geometry data are synthesized based on the same information used for the objective model. For the comparisons of the predictabilities of the models, two different measures are employed. In the first measure, the ensemble probability maps of the models are developed from multiple realizations, which are compared in depth to the objective model. In the second measure, the developed realizations are converted to hydrogeologic properties and the groundwater flow simulation results are compared to that of the objective model. From the comparisons, it is found that the predictability of GCMC outperforms the other models in terms of the first measure. On the other hand, in terms of the second measure, the both predictabilities of GCMC and SNESIM are outstanding out of the considered models. The excellences of GCMC model in the comparisons may attribute to the incorporations of directional non-stationarity and the non-linear prediction structure. From the results, it is concluded that the various geostatistical models need to be comprehensively considered and comparatively analyzed for appropriate characterizations.