• Title/Summary/Keyword: Multi-column

Search Result 333, Processing Time 0.024 seconds

Unequal depth beam to column connection joint

  • Ben Mou;Aijia Zhang;Wei Pan
    • Steel and Composite Structures
    • /
    • v.46 no.6
    • /
    • pp.823-837
    • /
    • 2023
  • This paper presents the seismic performance of seven beam-column joints with an eccentricity between beam depths under cyclic loadings. The failure modes of the panel zone were divided into two types. One was the shear force failure that appeared in the entire panel zone (SFEPZ), the other was the shear force failure that appeared in the partial panel zone (SFPPZ). Seven finite element models were established using multi-scale methods. Compared with the experimental specimens, the hysteretic loops exhibited a similar trend. The multi-scale models could accurately simulate the experimental results. Furthermore, the calculation formulas of yield and plastic shear capacity of unequal-depth joints with outer annular stiffener were proposed.

Study on the Development of Analytical Method (Multi-Pesticide Residue Method) for Organophosphate Pesticides (유기인제 농약 분석 방법 (Multi-Pesticide Residue Method) 개발에 관한 연구)

  • 이봉헌;김우성
    • Journal of Environmental Science International
    • /
    • v.6 no.2
    • /
    • pp.183-187
    • /
    • 1997
  • Organophosphate pesticides were extracted with 70% acetone and then transferred to dichloromethane. Extracts were applied to open-column chromatography with florisil. The florial extract was analyzed by gas chromatography with nitrogen-phosphorus detector(GC/NPD). Recoveries of the 18 organophosphate pesticides were ranged from 88.7% to 100. 0% for the narrow-bore capillary GC(Ultra-21. The minimum detectable level of this analytical method was 0.019 - 0.035 mg/kg. Sample throughput(extraction, open-column chro- matography, and GC analysts) was decreased considerably (8h per sample).

  • PDF

Free Vibrations and Buckling Loads of Axially Loaded Cross-Ply Laminated Composite Beam-Columns with Multiple Delaminations (다층간분리된 직교 적층 보-기둥의 자유진동과 좌굴하중)

  • 이성희;김형열;박기태;박대효
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.15 no.3
    • /
    • pp.523-534
    • /
    • 2002
  • Free vibration and buckling analysis of multi-delaminated composite beam-columns subjected to axial compressive load is performed in the present study In order to investigate the effects of multi-delaminations on the natural frequency and the elastic buckling load of multi-delaminated beam-columns, the general kinematic continuity conditions are derived from the assumption of constant slope and curvature at the multi-dclamination tip. The characteristic equation of multi-delaminated beam-column is obtained by dividing the global multi-delauunated beam-columns into segments and by imposing recurrence relation from the continuity conditions on each sub-beam-column. The natural frequency and the elastic buck)ing load of multi-delaminated beam-columns according to the incremental load of axial compression, which is limited to the maximum elastic buckling load of sound laminated beam-column, are obtained. It is found that the sizes, locations and numbers of multi-delaminations have significant effect on natural frequency and elastic buckling load, especially the latter ones.

Nonlinear Analysis of IPS System using the multi-noded cable element (다절점 케이블요소를 이용한 IPS 시스템의 비선형 해석)

  • Lee Jun-Seok;Kim Moon-Young;Han Man-Yop;Kim Sung-Bo;Kim Nak-Kyung
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2006.04a
    • /
    • pp.623-630
    • /
    • 2006
  • In this paper, a geometric nonlinear analysis procedure of beam-column element including multi-noded cable element is presented. For this, first a stiffness matrix about beam-column element which considers the second effect of initial force supposing the curved shape at each time step with Hermitian polynomials as the shape function is derived and second, tangent stiffness matrix about multi-noded cable element being too. To verify geometric nonlinearity of this newly developed multi-noded cable-truss element, IPS(Innovative Prestressed Support) system using this theory is analysed by geometric nonlinear method and the results are compared with those by linear analysis.

  • PDF

Behaviour of RC beam-column joint with varying location of construction joints in the column

  • Vanlalruata, Jonathan;Marthong, Comingstarful
    • Earthquakes and Structures
    • /
    • v.20 no.1
    • /
    • pp.29-38
    • /
    • 2021
  • According to ACI 224.3R-95 (ACI, 2013), construction joints (cold joint) in the column are to be provided at the top of floor slab for column continuing to the next floor and underside of floor slab and beam. A recent study reveals that providing cold joint of the mentioned location significantly reduced the seismic performance of the frame structures. Since, the construction joints in multi-story frame structures normally provided at the top of the floor slabs and at soffit of the beam in the column. This study investigated the effect of construction joint at various location in the column of beam-column joint such as at the top of floor slab, soffit level of the beam, half the depth of beam below the soffit of the beam and at a full depth of the beam below the soffit of the beam. The study revealed that there is an improvement in seismic capacity of the specimens as the location of cold joint is placed away from the soffit of the beam for lower story column.

An Experimental Study on Motions of two Pin-jointed Multi-floating Bodies (Pin-joint 연결된 다수 부유체의 운동에 대한 실험적 연구)

  • Lee, Seung-Chul;Bae, Sung-Yong;Goo, Ja-Sam
    • Journal of Power System Engineering
    • /
    • v.20 no.3
    • /
    • pp.5-10
    • /
    • 2016
  • The structure of the variable liquid column oscillator(VLCO) is analogous to that of the tuned liquid column damper used to suppress oscillatory motion in large structures like tall buildings and cargo ships. VLCO is using the technology which absorbs high potential energy made by process of accelerated motions effect of air spring by installation of inner air chamber. So, the application of VLCO can improve the efficiency of energy than that of wave energy converters made in Pelamis Company. In this research, experiments were performed for the models which have two different liquid column sizes. In order to find out the biggest motion response, two major conditions are taken into account. Two conditions are to open(or close) the valves and to differentiate the height of the liquid column.

Effect of the Off-axis distance of the Electron Emitting Source in Micro-column (마이크로 칼럼의 전자 방출원 위치 오차의 영향)

  • Lee, Eung-Ki
    • Journal of the Semiconductor & Display Technology
    • /
    • v.9 no.1
    • /
    • pp.17-21
    • /
    • 2010
  • Currently miniaturized electron-optical columns find their way into electron beam lithography systems. For better lithography process, it is required to make smaller spot size and longer working distance. But, the micro-columns of the multi-beam lithography system suffer from chromatic and spherical aberration, even when the electron beam is exactly on the symmetric axis of the micro-column. The off-axis error of the electron emitting source is expected to become worse with increasing off-axis distance of the focusing spot. Especially the electron beams far from the system optical axis have a non-negligible asymmetric intensity distribution in the micro-column. In this paper, the effect of the off-axis e-beam source is analyzed. To analyze this effect is to introduce a micro-column model of which the e-beam emitting source is aligned with the center of the electron beam by shifting them perpendicular to the system optical axis. The presented solution can be used to analysis the performance of the multi-electron-beam system. The performance parameters, such as the working distances and the focusing position are obtained by the computational simulations as a function of the off-axis distance of the emitting source.

Damage Distribution of Weak Beam Type Multi-Story Steel Frames By Seismic Response Analysis (지진 응답해석에 의한 보항복형 강구조 다층골조의 손상분포)

  • 오상훈
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2000.04a
    • /
    • pp.241-248
    • /
    • 2000
  • In order to evaluate the limit earthquake resistance of multi-story steel frames influenced by the strength and stiffness ratios of members a series inelastic response analysis were carried out. From the analysis results the damage distribution rules of multi-story steel frames were proposed. Conclusions are summarized as follows. 1)As the stiffness ratio of beam and column becomes small damage concentrate on the lower end of columns of the first story. 2) Considering the strength and stiffness ratios of beam and column with weak beam type mechanism the equations predicting the damage distribution of multi-story steel frames were proposed.

  • PDF