• 제목/요약/키워드: Multi-chamber

검색결과 309건 처리시간 0.028초

호흡연동 용적변조 회전방사선치료에서 호흡주기에 따른 선량전달 정확성 검증 (Dose verification for Gated Volumetric Modulated Arc Therapy according to Respiratory period)

  • 전수동;배선명;윤인하;강태영;백금문
    • 대한방사선치료학회지
    • /
    • 제26권1호
    • /
    • pp.137-147
    • /
    • 2014
  • 목 적 : 호흡연동 용적변조 회전방사선치료(Gated Volumetric Modulated Arc Therapy)에서 환자의 호흡주기 변화에 따른 선량전달의 정확성을 검증하고자 한다. 대상 및 방법 : 실험에는 TrueBeam STxTM(Varian Medical Systems, Palo Alto, CA)치료기를 사용하였다. 인체모형등가팬텀(Rando Phantom, Alderson Resarch Laboratories Inc. Stamford. CT, USA)의 전산화단층영상에 전산화치료계획시스템(Eclipse 10.0, Varian, USA)을 이용하여 10 MV FFF(Flatenning Filter Free), 선량률 1200 MU/min으로 1500 cGy/fx(Case1, 2, 3)과 220 cGy/fx(Case4, 5, 6)의 치료계획을 수립하였다. $QUASAR^{TM}$ Respiratory Motion Phantom(Modus Medical Devices Inc)을 이용하여 1.5, 2.5, 3.5, 4.5 sec의 일정한 호흡주기와 평균호흡주기가 2.2, 3.5 sec인 환자의 호흡주기를 재현하였고 위상모드 30~70% 구간에서 방사선이 조사되도록 설정하였다. 각각의 호흡 조건에서 2차원 이온전리함 배열 검출기(I'mRT Matrixx, IBA Dosimetry, Germany)와 MultiCube Phantom(IBA Dosimetry, Germany)을 이용하여 측정하였고 세기변조 방사선치료 분석 프로그램(OmniPro I'mRT, IBA Dosimetry, Germany)을 이용하여 Gamma pass rate(3 mm, 3%)을 비교하였다. 결 과 : Case 1, 2, 3, 4, 5, 6의 Gamma pass rate은 일정한 호흡주기 1.5 sec에서 100.0, 97.6, 98.1, 96.3, 93.0, 94.8%, 2.5 sec에서 98.8, 99.5, 97.5, 99.5, 98.3, 99.6%, 3.5 sec에서 99.6, 96.6, 97.5, 99.2, 97.8, 99.1%, 4.5 sec에서 99.4, 96.3, 97.2, 99.0, 98.0, 99.3%의 결과를 보였다. 환자의 호흡을 재현한 경우 평균 호흡주기 2.2 sec에서는 97.7, 95.4, 96.2, 98.9, 96.2, 98.4%, 3.5 sec에서는 97.3, 97.5, 96.8, 100.0, 99.3 99.8%의 결과를 보였다. 결 론 : 2.5 sec이상의 일정한 호흡주기와 환자의 호흡을 재현한 실험에서 Gamma pass rate 95%이상의 임상적으로 신뢰할 만한 결과를 보였다. 일정한 호흡주기 1.5 sec의 Case 5, 6 에서 93.0, 94.8%의 결과를 보였으나 100명의 환자 호흡주기 분석 결과 1.5 sec의 호흡을 지속했던 경우는 없었던 점으로 보아 대부분의 호흡조건에서 정확한 선량전달이 가능함을 확인 하였다. 다만 극히 짧은 호흡주기로 인한 오차발생 가능성을 배제할 수 없기 때문에 치료전 선량전달 정확성 검증이 선행되어야 하며 모의치료시 환자 교육으로 안정된 호흡을 유지하고 정확한 모니터링을 통해 치료중 환자 호흡변화에 대처한다면 더욱 안정적이고 정확한 치료가 이루어질 것으로 사료된다.

갈조류 모자반, Sargassum fulvellum (Turner) C. Agardh의 성숙과 초기생장

  • 황은경;박찬선;김철원;백재민;손철현
    • 한국양식학회:학술대회논문집
    • /
    • 한국양식학회 2003년도 추계학술발표대회 논문요약집
    • /
    • pp.119-120
    • /
    • 2003
  • 우리나라에 분포하는 모자반류는 모두 28종으로 알려져 있으며 (이와 강 2002) 이 가운데 식용으로 이용되는 것은 모자반 (S. fulvellum)이 대표적이다. 모자반의 양식은 주로 서남해 지역에서 이루어지고 있으며 이들의 종묘생산은 자연에서 생식기탁이 성숙되는 4-5월경에 이루어지는데, 유배의 대량 방출을 위한 성숙 모조의 다량 확보가 어렵고 일시에 유배의 대량 방출을 유도하기 위한 성숙 유도 기법의 연구는 전무한 실정이다. 따라서 이 연구에서는 모조의 실내 배양을 통하여 유배의 대량 방출을 위한 성숙 유도 기법과 배양 조건별 엽체의 성숙 및 난방출율을 구하여 모자반의 조기채묘에 유용한 자료로 사용하고자 하였다. 또한 채묘된 발아체의 초기생장에 필요한 최적 배양 환경을 구명하고자 하였다. 모자반 모조는 전남 진도군 조도 지역의 수심 3-5m에서 채집하였으며, 채집 즉시 실험실로 운반하여 유수식 사육 수조에 수용하였다. 성숙 유도는 20$\ell$ 플라스틱 bottle을 사용하였으며, 성숙률의 정량화를 위하여 암생식기탁을 절단하여 수차례 멸균해수에서 세척후 멸균된 5cm직경의 petri dish에 멸균해수20$m\ell$와 함께 수용하여 Multi-chamber incubator에서 배양하였다. 배양조건은 5개 온도조건 (5, 10, 15, 20, $25^{\circ}C$)과16:8h의 장일 광주기 조건으로하였으며 조도는 80 $\mu$molm$^{-2}$ s$^{-1}$로 하였다. 모든 실험구는 3반복 실험하였으며 2일 간격으로 생식기탁의 생장 및 성숙 그리고 난방출 여부를 현미경하에서 측정하였다. 난이 방출된 모조로부터 유배를 분리하여 3개 조도 구간 (30, 60, 100 $\mu$molm$^{-2}$ s$^{-1}$)과 5개 온도 구간 (5, 10, 15, 20, $25^{\circ}C$)의 조합인 15개 배양 조건하에서 엽체의 길이생장을 측정하였다. 생식기탁으로부터 난의 방출은 15$^{\circ}C$와 2$0^{\circ}C$ 조건에서 배양 2일후부터 방출되기 시작하였으며, 배양 9일후 2$0^{\circ}C$ 조건에서 가장 높은 96.7$\pm$5.8%의 난방출율을 보였다. 또한 15$^{\circ}C$ 조건에서는 배양 9일후 76.7%의 난방출율을 보였다. 1$0^{\circ}C$$25^{\circ}C$ 조건에서는 배양 11일까지 36.7%의 난방출율을 나타내어 온도 조건에 따라 난방출 비율에 차이를 보였다. 따라서 이러한 실내 배양 결과를 다량의 모조를 조기에 성숙시키기 위해 모조 수용 수조의 수온을 자연수온보다 2~5$^{\circ}C$ 높은 12~15$^{\circ}C$ 조건으로 유지하여 15일간의 수조 관리 후 모조의 대량 유배 방출을 유도할 수 있었다. 모조 성숙을 위한 사육 수조의 수온을 2$0^{\circ}C$ 이상으로 가온할 경우 엽체의 끝녹음을 유발하였으며 가온에 따르는 가온 비용이 수반되므로 엽체의 난방출율이 70% 이상에 도달하는 15$^{\circ}C$ 조건으로 유지하는 것이 경제적일 뿐만 아니라 엽체의 건전도 유지에도 바람직하였다. 유배의 초기생장은1$0^{\circ}C$와15$^{\circ}C$의 온도조건에서 길이생장이 빠르게 증가하여, 배양 35일 후 15$^{\circ}C$와 60 $\mu$molm$^{-2}$ s$^{-1}$의 조건에서 3.9$\pm$0.2mm로 가장 높은 값을 나타내었다. 엽체의 초기 길이생장은 15$^{\circ}C$, 60 $\mu$molm$^{-2}$ -s$^{-1}$의 조도 조건에서 가장 우세하였으며, 다음으로 30과 100 $\mu$molm$^{-2}$ s$^{-1}$의 조건 순으로 나타났다. 2$0^{\circ}C$$25^{\circ}C$의 온도 조건에서는 각각 1.8~2.1mm로 길이생장에 있어 유의한 차이가 없는 것으로 나타났다.

  • PDF

용적변조회전 방사선치료에서 Portal Dosimetry를 이용한 선량평가의 재현성 분석 (Evaluate the implementation of Volumetric Modulated Arc Therapy QA in the radiation therapy treatment according to Various factors by using the Portal Dosimetry)

  • 김세현;배선명;서동린;강태영;백금문
    • 대한방사선치료학회지
    • /
    • 제27권2호
    • /
    • pp.167-174
    • /
    • 2015
  • 목 적 : 복잡하고 정교하게 계획된 용적변조회전 방사선치료(Volumetric Arc Therapy, VMAT)의 Portal Dosimetry를 이용한 치료 전 선량평가가 다양한 인자에 따라 재현성을 유지하는지 분석하고자 하였다. 대상 및 방법 : 실험에는 TrueBeam STx$^{TM}$(Ver.1.5, Varian, USA), Portal dosimetry application(Ver.10, Varian)과 Portal Vision aS1000 Imager(Varian, USA)을 사용하였다. 두경부암 환자 2명, 전립샘암 환자 3명, 폐암 환자 1명, 자궁경부암 환자 1명, 총 7명의 환자에 대하여 Portal Dosimetry용 VMAT 전산화치료계획(Eclipse, Ver.10.0, Varian, USA)을 수립하였다. 오전 치료 전과 후 오후 치료 종료 후 각 4시간 간격을 두고 3회씩 5일에 걸쳐 선량평가를 시행하였다. Gamma pass rate(GPR 3%, 3mm 95%신뢰구간)와 Beam 출력의 상관관계를 확인하기 위하여 선량평가 시행 전 Beam 출력 을 물등가모형과 이온전리함(IBA dosimetry, Germany)을 이용하여 측정하였다. Electronic Portal Imaging Device(EPID) 상태에 따른 GPR 의 변화를 확인하기 위하여 EPID의 영상 교정 (Dark field correction, Flood field correction) 전과 후로 나누어 선량평가를 시행하였다. 또한 다엽콜리메이터(Multi Leaf Collimator) 상태에 따른 GPR의 변화를 확인하기 위해 다엽콜리메이터 Initialize 전과 후로 나누어 선량평가를 시행하였다. 결 과 : Portal Dosimetry를 시행하여 얻은 모든 환자들의 각 시간대 별 GPR의 평균값은 97.11%, 96.09%, 95.37% 였고 최대 차이를 보인 환자의 경우 각 시간대 별 GPR의 평균값은 95.73%, 94.20% 93.23% 였다. 선량평가 시점의 Beam 출력을 측정한 결과 각 시간대별 평균값은 100.45%, 100.46%, 100.59% 였다. EPID의 영상 교정(Dark field correction, Flood field correction)을 시행하기 전과 후의 대상 환자들의 GPR의 평균값은 95.94 %, 96.01% 였다. 또한 다엽콜리메이터 의 Initialize 를 시행하기 전과 후의 대상 환자들의 GPR 의 평균값은 95.83%, 96.40%였다. 결 론 : 치료기 사용시간이 경과됨에 따라 대상 환자들의 GPR 평균값이 0.8% 감소함을 확인할 수 있었다. Beam 출력은 각 측정시점에 0.1% 오차범위 안에서 일정한 상태를 유지하였다. EPID의 영상 교정 전, 후 의 선량평가 결과 GPR은 평균 0.1% 차이를 나타내었다. 다엽콜리메이터의 Initialize 전, 후의 선량평과 결과 Initialize 시행 후 GPR이 평균 0.6% 상승하였고 다엽콜리메이터 상태에 따라 GPR이 변화할 수 있다는 것을 확인할 수 있었다. 복잡하고 정교하게 계획된 VMAT의 치료 전 선량평가 도구로서 재현성을 유지하며 Portal Dosimetry를 이용하기 위해서는 주기적인 장비의 점검뿐만 아니라, 선량평가에 영향을 미칠 수 있는 다양한 인자들에 대한 관리가 이뤄져야 할 것으로 판단된다.

  • PDF

하나로 원자로 BNCT 열중성자 조사장치에 대한 선량특성연구 (Dosimetric Characteristics of a Thermal Neutron Beam Facility for Neutron Capture Therapy at HANARO Reactor)

  • 이동한;서소희;지영훈;최문식;박재홍;김금배;류성렬;김명섭;이병철;천기정;조재원;김미숙
    • 한국의학물리학회지:의학물리
    • /
    • 제18권2호
    • /
    • pp.87-92
    • /
    • 2007
  • 최대출력 30 MW, 하나로(HANARO) 다목적 연구용 원자로의 접선 중성자공에 붕소중성자포획치료(Boron Neutron Capture Therapy, BNCT)를 위한 열중성자 조사장치가 개발되었다. BNCT 조사장치에서는 서로 다른 물리적 특성과 생물학적 효과비를 가진 여러 성분의 방사선이 방출되기 때문에 정확한 투여선량을 결정하기 위해서는 각 성분의 정량적 분석이 필수적이다. 따라서 본 연구에서는 방사화 분석, 열형광선량계 및 이온전리함 등 여러 유형의 검출기를 사용하여 BNCT 조사장치에서 방출되는 열중성자 및 감마선 혼합장의 선량 성분을 분리, 측정하였다. 선량측정은 물 속에 함유된 불순물과 중성자의 이차반응을 최소화하기 위해 증류수를 채운 물팬텀을 이용하였다. 그리고 측정 결과는 MCNP4B 전산계산의 결과와 상호 비교하였다. 측정 결과 열중성자속은 물팬텀 10 mm와 20 mm 깊이에서 각각 $1.02E9n/cm^2{\cdot}s$$6.07E8n/cm^2{\cdot}s$이었고, 고속중성자선량율은 10 mm 깊이에서 0.11 Gy/hr로 미세하였다. 감마선량률은 물팬텀 20 mm 깊이에서 5.10 Gy/hr로 나타났다. 측정된 중성자와 감마선량값은 MCNP의 결과와 5% 이내로 잘 일치하였고, 열중성자속은 14%의 비교오차를 나타내었다. 이러한 결과들은 중성자 검출의 난이도를 고려할 때 충분히 신뢰할 수 있는 수준이라 판단되며, BNCT 임상 연구를 위한 선량평가 자료로 활용할 수 있을 것으로 사료된다.

  • PDF

Carbon nanotube field emission display

  • Chil, Won-Bong;Kim, Jong-Min
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제12권7호
    • /
    • pp.7-11
    • /
    • 1999
  • Fully sealed field emission display in size of 4.5 inch has been fabricated using single-wall carbon nanotubes-organic vehicle com-posite. The fabricated display were fully scalable at low temperature below 415$^{\circ}C$ and CNTs were vertically aligned using paste squeeze and surface rubbing techniques. The turn-on fields of 1V/${\mu}{\textrm}{m}$ and field emis-sion current of 1.5mA at 3V/${\mu}{\textrm}{m}$ (J=90${\mu}{\textrm}{m}$/$\textrm{cm}^2$)were observed. Brightness of 1800cd/$m^2$ at 3.7V/${\mu}{\textrm}{m}$ was observed on the entire area of 4.5-inch panel from the green phosphor-ITO glass. The fluctuation of the current was found to be about 7% over a 4.5-inch cath-ode area. This reliable result enables us to produce large area full-color flat panel dis-play in the near future. Carbon nanotubes (CNTs) have attracted much attention because of their unique elec-trical properties and their potential applica-tions [1, 2]. Large aspect ratio of CNTs together with high chemical stability. ther-mal conductivity, and high mechanical strength are advantageous for applications to the field emitter [3]. Several results have been reported on the field emissions from multi-walled nanotubes (MWNTs) and single-walled nanotubes (SWNTs) grown from arc discharge [4, 5]. De Heer et al. have reported the field emission from nan-otubes aligned by the suspension-filtering method. This approach is too difficult to be fully adopted in integration process. Recently, there have been efforts to make applications to field emission devices using nanotubes. Saito et al. demonstrated a car-bon nanotube-based lamp, which was oper-ated at high voltage (10KV) [8]. Aproto-type diode structure was tested by the size of 100mm $\times$ 10mm in vacuum chamber [9]. the difficulties arise from the arrangement of vertically aligned nanotubes after the growth. Recently vertically aligned carbon nanotubes have been synthesized using plasma-enhanced chemical vapor deposition(CVD) [6, 7]. Yet, control of a large area synthesis is still not easily accessible with such approaches. Here we report integra-tion processes of fully sealed 4.5-inch CNT-field emission displays (FEDs). Low turn-on voltage with high brightness, and stabili-ty clearly demonstrate the potential applica-bility of carbon nanotubes to full color dis-plays in near future. For flat panel display in a large area, car-bon nanotubes-based field emitters were fabricated by using nanotubes-organic vehi-cles. The purified SWNTs, which were syn-thesized by dc arc discharge, were dispersed in iso propyl alcohol, and then mixed with on organic binder. The paste of well-dis-persed carbon nanotubes was squeezed onto the metal-patterned sodalime glass throuhg the metal mesh of 20${\mu}{\textrm}{m}$ in size and subse-quently heat-treated in order to remove the organic binder. The insulating spacers in thickness of 200${\mu}{\textrm}{m}$ are inserted between the lower and upper glasses. The Y\ulcornerO\ulcornerS:Eu, ZnS:Cu, Al, and ZnS:Ag, Cl, phosphors are electrically deposited on the upper glass for red, green, and blue colors, respectively. The typical sizes of each phosphor are 2~3 micron. The assembled structure was sealed in an atmosphere of highly purified Ar gas by means of a glass frit. The display plate was evacuated down to the pressure level of 1$\times$10\ulcorner Torr. Three non-evaporable getters of Ti-Zr-V-Fe were activated during the final heat-exhausting procedure. Finally, the active area of 4.5-inch panel with fully sealed carbon nanotubes was pro-duced. Emission currents were character-ized by the DC-mode and pulse-modulating mode at the voltage up to 800 volts. The brightness of field emission was measured by the Luminance calorimeter (BM-7, Topcon).

  • PDF

몬순기후와 복잡지형의 특성을 갖는 광릉 산림유역의 물과 탄소순환에 대한 교차규모 연구로부터의 교훈 (Lessons from Cross-Scale Studies of Water and Carbon Cycles in the Gwangneung Forest Catchment in a Complex Landscape of Monsoon Korea)

  • 이동호;김준;김수진;문상기;이재석;임종환;손요환;강신규;김상현;김경하;우남칠;이부용;김승
    • 한국농림기상학회지
    • /
    • 제9권2호
    • /
    • pp.149-160
    • /
    • 2007
  • 광릉 슈퍼사이트에서 대기와 식생간의 에너지와 물질교환 규명은 지형과 식생의 복잡성으로 인해 많은 기술적인 어려움에 직면하고 있다. 따라서 KoFlux 연구에서는 상호보완적인 다중 분야의 연구를 통해 이러한 어려움을 극복하기 위한 시도를 해 오고 있다. 본 논문에서는 현재 진행중인 KoFlux 연구의 예비결과 중 특히 광릉사이트에서의 물/탄소수지, 물과 탄소순환의 상호관련성 그리고 몬순기후하의 생태계에서 탄소순환에 미치는 수문학적 요인의 중요성에 대해 중점적으로 논의하고자 한다. 광릉낙엽활엽수림의 순생태생산량 (NEP)은 광범위한 생태학적 연구결과에 따르면 약 ${\sim}2.6\;t\;C/ha/y$로 예상된다. 이를 미기상 플럭스 관측 결과와 함께 고려할 때 광릉 산림은 탄소의 중요한 육상흡원으로서 기능함을 예상할 수 있다. 다양한 생태수문 관측에 의해 규명된 유역단위 물수지에 의하면 연단위 전체강수량의 약 30-40%가 증발산(ET)에 해당함을 나타내고 있다. 광릉산림의 대표적인 수종인 졸참과 서어나무의 잎에서 얻어진 탄소 안정동위원소 조성에 근거하여 계산된 식물 성장기간의 평균 물이용효율(WUE)은 약 ${\sim}12\;{\mu}mol\;CO_2/mmol\;H_2O$에 해당된다. 얻어진 증발산량과 물이용효율은 유역단위의 생태계 생산량을 산출하는데 이용될 수 있다. 나이테 성장량과 토양호흡량의 연단위 변화는 강수량과 강수의 패턴에 의해 크게 영향을 받음을 보이고, 이는 몬순기후에 영향을 받는 동아시아 지역 생태계에서 탄소 순환과정이 수문학적 조건과 밀접한 상관관계를 가짐을 지시한다. 연구지역의 공간적 특성을 정량화하기 위해 관측지의 구조 및 기능적 단위를 규명하기 위한 연구가 진행되고 있고 이를 통해 서로 다른 시공간 규모에서 진행되고 있는 연구의 결과물을 체계적으로 연결 통합하고 나아가 보다 광역적인 규모에서 대표적인 물/탄소 수지를 산출하기 위한 연구가 시도되고 있다.

스퍼터링 코팅기법을 이용한 중성자 검출용 B4C 박막 개발 (Development of B4C Thin Films for Neutron Detection)

  • 임창휘;김종열;이수현;조상진;최영현;박종원;문명국
    • Journal of Radiation Protection and Research
    • /
    • 제40권2호
    • /
    • pp.79-86
    • /
    • 2015
  • 헬륨-3는 높은 반응효율, 장시간 사용가능성, 감마선에 대한 낮은 반응확률 등과 같은 장점들을 가지고 있기 때문에 대부분의 중성자 검출기의 반응물질로 사용되어 왔다. 그러나 지난 몇 년 사이 전세계적인 헬륨-3의 부족으로 인해 기체의 수급이 어려워지고 있고 이에 따라 가격이 급격히 증가하게 되었다. 이러한 이유로 헬륨-3 대체 물질들을 이용한 고효율의 중성자 검출기의 개발에 대한 연구가 많은 연구그룹에 의해 활발히 진행되기 시작하였다. 이러한 연구에서는 다양한 물질들을 이용하고 있으며, 이 중에서 붕소-10은 다른 대체물질과 비교할 때 상대적으로 높은 중성자 반응확률, 낮은 감마반응효율, 물질의 안정성, 가격적 이점 그리고 기존 헬륨-3를 이용한 검출기의 계측회로의 재활용 가능성 등과 같은 장점들 때문에 많은 연구그룹에서 붕소-10을 이용한 중성자 검출기 개발을 진행하고 있다. 본 논문에서는 중성자 검출기에 사용될 수 있는 붕소-10 박막을 개발하고 이에 대한 성능평가를 수행하였다. 중성자 검출기의 반응물질로 붕소-10을 사용하기 위해서는 중성자와 붕소-10이 반응하여 생성되는 이차방사선을 측정할 수 있어야 한다. 본 연구에서 활용한 기체충진형 중성자 검출기의 경우 붕소-10을 얇은 박막 형태로 제작하여 중성자와 반응하여 생성된 이차방사선이 기체를 이온화 시켜서 생성되는 이온쌍을 측정하는 방법을 이용한다. 그러므로 중성자 반응효율과 이차방사선의 재흡수율을 고려한 붕소-10(탄화붕소)의 적절한 두께를 선정할 필요가 있다. 이를 위해서 본 논문에서는 몬테칼로 기법을 이용하는 MCNP6를 이용하여 다양한 두께에 따른 중성자신호수집효율의 변화를 계산하였다. 또한, 스퍼터링 기법을 이용하여 다양한 두께의 박막을 제작하고 이를 이용하여 중성자 반응신호를 측정하였다. 그리고 제작된 박막의 2차원 모니터링을 위한 다중선 비례계수기의 적용가능성을 타진하기 위해 제작된 붕소박막이 설치된 2차원 다중선 비례계수기를 제작하고 중성자 응답 특성을 평가하였다.

팬텀을 이용한 다기능 위.십이지장관 코일 카테타의 유용성 평가 (Usefuless of Multi-functional Gastroduodenal Coil Catheter with Phantom)

  • 임진오;김태형;정양화;최원찬;신지훈;송호영
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제26권4호
    • /
    • pp.21-26
    • /
    • 2003
  • 새로 개발된 다기능 위.십이지장관 코일 카테타의 유용성을 체외실험을 통하여 평가하고자 한다. 위.십이지장 코일 카테타는 전체길이가 150 cm되게 하여 두께 0.3 mm의 스테인레스 세선을 내경 1.3 mm 코일스프링으로 만들고 폴리에틸렌계의 열수축 튜브를 피복하였다. 카테타의 원위부 끝에서 2 0cm 지점까지 금 표식자 7개를 부착하여 방사선 투시상 길이 측정이 가능하게 하였으며, 원위부 7cm, 13 cm, 19 cm 지점에 조영제 분사가 가능하도록 측부 분사구를 제작하였다. 기존의 5 Fr. 혈관용 카테타와 새롭게 제작된 코일 카테타를 대상으로 방사선 불투과도와 조영제 분사능력을 평가하였다. 방사선 불투과도는 필름농도를 비교하였고, 조영제 분사능력은 아크릴을 이용하여 4개의 함을 제작하고 그 내부에 카테타를 위치시킨 후 자동주입기를 이용하여 생리식염수를 주입하여 카테타 내부에 안내철사를 삽입했을 경우와 하지 않았을 경우에서의 조영제 분사율을 측정하였다. 방사선 불투과도는 5 Fr. 혈관용 카테타에서 0.51, 새롭게 제작된 코일 카테타는 0.31이 측정되었고, 조영제 분사량은 5 Fr. 혈관용 카테타는 안내철사를 삽입한 경우와 삽입하지 않은 경우 동일하게 원위부에서만 99.5%분사하였다. 코일 카테타는 안내철사를 삽입한 경우 원위부로부터 각각 1.17%, 18.8%, 41.8%, 38.2%가 분사되었고 안내철사를 삽입하지 않았을 경우 원위부로부터 각각 19.5%, 32.6%, 27.7%, 20.3%가 분사되었다. 새로 개발된 위.십이지장 카테타는 기존의 카테타와 비교하여 방사선 투시상 확인이 용이하여 길이측정이 쉽고, 조영제 분사능력이 우수하여 위.십이지장의 중재시술시 유용하게 사용될 것으로 판단된다.

  • PDF

공기조화, 냉동 분야의 최근 연구 동향: 2006년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2006)

  • 한화택;신동신;최창호;이대영;김서영;권용일
    • 설비공학논문집
    • /
    • 제20권6호
    • /
    • pp.427-446
    • /
    • 2008
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2006 has been accomplished. Focus has been put on current status of research in the aspect of heating, cooling, ventilation, sanitation and building environments. The conclusions are as follows. (1) The research trends of fluid engineering have been surveyed as groups of general fluid flow, fluid machinery and piping, etc. New research topics include micro heat exchanger and siphon cooling device using nano-fluid. Traditional CFD and flow visualization methods were still popular and widely used in research and development. Studies about diffusers and compressors were performed in fluid machinery. Characteristics of flow and heat transfer and piping optimization were studied in piping systems. (2) The papers on heat transfer have been categorized into heat transfer characteristics, heat exchangers, heat pipes, and two-phase heat transfer. The topics on heat transfer characteristics in general include thermal transport in a cryo-chamber, a LCD panel, a dryer, and heat generating electronics. Heat exchangers investigated include pin-tube type, plate type, ventilation air-to-air type, and heat transfer enhancing tubes. The research on a reversible loop heat pipe, the influence of NCG charging mass on heat transport capacity, and the chilling start-up characteristics in a heat pipe were reported. In two-phase heat transfer area, the studies on frost growth, ice slurry formation and liquid spray cooling were presented. The studies on the boiling of R-290 and the application of carbon nanotubes to enhance boiling were noticeable in this research area. (3) Many studies on refrigeration and air conditioning systems were presented on the practical issues of the performance and reliability enhancement. The air conditioning system with multi indoor units caught attention in several research works. The issues on the refrigerant charge and the control algorithm were treated. The systems with alternative refrigerants were also studied. Carbon dioxide, hydrocarbons and their mixtures were considered and the heat transfer correlations were proposed. (4) Due to high oil prices, energy consumption have been attentioned in mechanical building systems. Research works have been reviewed in this field by grouping into the research on heat and cold sources, air conditioning and cleaning research, ventilation and fire research including tunnel ventilation, and piping system research. The papers involve the promotion of efficient or effective use of energy, which helps to save energy and results in reduced environmental pollution and operating cost. (5) Studies on indoor air quality took a great portion in the field of building environments. Various other subjects such as indoor thermal comfort were also investigated through computer simulation, case study, and field experiment. Studies on energy include not only optimization study and economic analysis of building equipments but also usability of renewable energy in geothermal and solar systems.