• 제목/요약/키워드: Multi-Story Piping

검색결과 4건 처리시간 0.023초

Analytical Studies on Seismic Performance of Multi-Story Coupled Piping System in a Low-Rise Building

  • Jung, WooYoung;Ju, BuSeog
    • 한국지진공학회논문집
    • /
    • 제17권4호
    • /
    • pp.181-186
    • /
    • 2013
  • The construction costs for nonstructural systems such as mechanical/electrical equipment, ceiling system, and piping system occupy a significant proportion of the total cost. These nonstructural systems can also cause considerable economic losses and loss of life during and after an earthquake. Therefore, reduction of seismic risk of nonstructural components has been emerging as a key aspect of research in recent year. The primary objective of this study was to evaluate the seismic performance of a single-story and multi-story piping system installed in low-rise building and to identify the seismic vulnerability of the current piping systems. The seismic performance evaluation of the piping systems was conducted with 5 different earthquakes to account for the ground motion uncertainty and the preliminary results demonstrated that the maximum displacements of each floor in the multi-story piping system increased linearly with increasing floor level in the building system. This study revealed that the current design piping systems are significantly sensitive to the effect of floor height, which stress the necessity to improve the seismic performance of the current piping systems by, for example, strengthening with seismic sway bracing using transverse/longitudinal bracing cables or hangers.

아파트의 온수공급배관망해석 (Analysis on Heat Supply Piping Network for Apartment House)

  • 박윤철;황광일
    • 한국주거학회논문집
    • /
    • 제13권6호
    • /
    • pp.89-99
    • /
    • 2002
  • The purpose of this research is to analyze the characteristics of flow rate distribution in hot-water piping networks in the apartment building. A 14-story apartment house was selected as a sample building and analyzed numerically by Hardy-Cross method. Two different piping networks, one has three vertical zones and the other of a single zone with automatic balancing valves, were compared. Some of research results are as follows; As the temperature of supply hot-water increases, the flow rate of it does by buoyancy effect, but this effect is not found in the piping network with automatic balancing valves. Non-uniformity in hot-water flow distributions to all stories in the piping system of single vertical zone can be completely reformed by the installation of either manually operated or automatic balancing valves in every story.

지진격리된 복층구조 파이핑 시스템의 내진성능평가 (Seismic Performance Evaluation of Base-Isolated Multi-Story Piping System)

  • 전준태;류용희;주부석
    • 한국재난정보학회:학술대회논문집
    • /
    • 한국재난정보학회 2016년 정기학술대회
    • /
    • pp.311-313
    • /
    • 2016
  • 본 연구는 지진격리장치가 적용된 파이핑 시스템에서 빌딩과 같은 구조요소의 상호작용에 의한 동적 거동을 분석하고자 기존 복층구조 파이핑 시스템과 빌딩시스템에 triple friction pendulum이 적용된 격리장치를 적용 하였다. 파이핑 시스템의 시간이력해석에 의한 동적거동 평가를 위해 OpenSees를 이용하여 지진격리된 빌딩 및 파이핑시스템의 수치해석모델을 구축하였으며, 또한 파이핑시스템의 경우 ceiling system and supporting system 등과 같은 요소로 구분하여 유한요소모델을 구축하였다. 결과적으로 지진격리장치가 적용된 빌딩-파이핑 시스템의 경우 각층의 drift 및 변위가 일정한 반면 비 적용된 시스템의 경우 층 가속도에 의한 구조물의 변위가 빌딩층에 따라 상당히 증가함을 볼 수 있다.

  • PDF

지진격리장치를 적용한 복층구조파이핑 시스템의 내진성능평가 (Seismic Performance Evaluation of Multi-Story Piping Systems using Triple Friction Pendulum Bearing)

  • 류용희;주부석;손호영
    • 한국재난정보학회 논문집
    • /
    • 제14권4호
    • /
    • pp.450-457
    • /
    • 2018
  • 연구목적: 2016년 9월 경주 이후 구조물 및 비구조물의 지진 안전성 및 내진성능에 관한 문제가 이슈화 되고 있으며, 특히 배관 시스템의 경우 구조요소 보다 지진 발생시 내진성능에 있어서 취약하다고 볼 수 있다. 스프링클러 배관 시스템과 같은 비구조적 구성요소의 손상으로 인해 지진 발생 및 이후에 상당한 경제적 손실이나 생명 손실을 초래 할 수 있다. 연구방법: 본 연구는 Triple Friction Pendulum Bearings (TPBs)을 설치한 건물 배관 시스템을 이용한 소방 배관 시스템의 내진성능평가를 제시한다. Kobe, Kocaeli, GyeongJu 지진을 고려하여 지반 운동의 불확실성을 고려하였다. 연구결과: 빌딩 시스템과 파이핑 시스템의 첫 번째 모드는 각각 약 5.8Hz와 약 2.742Hz로 나타났으며, 또한 TPBs 시스템이 적용된 배관 시스템의 최대 변위는 Kobe, Kocaeli 및 GyeongJu 지진의 경우 각각 49%, 14.4%, 21.5%가 감소한 것으로 나타났다. 결론: 따라서 건물 배관 시스템에서 지진 격리 시스템을 사용하면 지진이 심할 때 TPB가 없는 일반적으로 설치된 걸물 배관 시스템보다 지진 위험을 줄일 수 있다.