• Title/Summary/Keyword: Multi-Frame PIV

Search Result 11, Processing Time 0.019 seconds

A Study on the Improvement of PIV Performance (PIV의 성능개선에 관한 연구)

  • 이영호;김춘식;최장운
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.18 no.3
    • /
    • pp.34-42
    • /
    • 1994
  • The present study is aimed to improve the PIV performance by suggesting a two-frame particle identification technique and by introducing estimation method of wall pressure distribution from the velocity data. Adopted image processing system consists of one commercial image board slit into a personal computer, 2-D sheet light generator, flow picture recording apparatus and related particle identification software. A revised particle tracking method essential to PIV performance is obtained by particle centroid correlation pairing (CCP) and its effectiveness is ascertained by comparison with multi-frame identification.

  • PDF

Measurement of Flow Field in a Domestic Hot-Water Pump by PIV (PIV에 의한 가정용 온수펌프의 유동장 계측)

  • Lee, H.;Im, Y. C.;Kim, J. H.;Lee, Y. H.
    • 유체기계공업학회:학술대회논문집
    • /
    • 1999.12a
    • /
    • pp.264-271
    • /
    • 1999
  • The present experimental study is aimed to investigate the flow characteristics of the high-speed flow field within hot-water pump by PIV(Particle Image Velocimetry). As multi-point simultaneous velocity acquisition, 2-D PIV system based upon the two-frame gray-level cross correlation method is adopted using PC frame-grabber and simple video system. Gated image intensifier CCD Camera to cope with illumination problem is arranged for accurate PIV measurement of high-speed complex flow. The velocity vector distribution, velocity profile, and kinetic energy are represented quantitatively at the full-scale region for the deeper understanding of the unsteady flow characteristics in a pump.

  • PDF

Multi-Prame MQD-PIV

  • Suh, Yong-Kweon
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.10
    • /
    • pp.1552-1562
    • /
    • 2003
  • In this paper, we propose a new PIV methodology for obtaining a velocity field from a sequence of multiple image data based on a least-square principle (also known as MQD; minimum quadratic difference) for the grey level difference between two neighboring frames of image data. We investigated both the accuracy of the result and the time consumption in the computation. It turns out that the proposed method is not only accurate but fast compared with the conventional correlation PIV techniques. Our method is applied to the spin-up flows and the results show that the method can be a good substitution for the conventional algorithms employed in the existing commercial codes.

A study on a development of a measurement technique for diffusion of oil spill in the ocean (디지털 화상처리에 의한 해양유출기름확산 계측기법개발에 관한 연구)

  • 이중우;김기철;강신영;도덕희
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 1998.10a
    • /
    • pp.211-221
    • /
    • 1998
  • A digital image processing technique which is able to get the velocity vector distribution of a surface of the spilled oil in the ocean without contacting the flow itself. This technique is based upon the PIV(Particle Imaging Velocimetry) technique and its system mainly consists of a high sensitive camera, a CCD camera, an image grabber, and a host computer in which an image processing algorithm is adopted for velocity vector acquisition. For the acquisition of the advective velocity vector of floating matters on the ocean, a new multi-frame tracking algorithm is proposed, and for the acquisition of the diffusion velocity vector distribution of the spilt oil onto the water surface, a high sensitive gray-level cross-correlation algorithm is proposed.

  • PDF

A Study on a Development of a Measurement Technique for Diffusion of Oil Spill in the Ocean (디지털 화상처리에 의한 해양유출기름확산 계측기법개발에 관한 연구)

  • 이중우;강신영;도덕희;김기철
    • Journal of Korean Port Research
    • /
    • v.12 no.2
    • /
    • pp.291-302
    • /
    • 1998
  • A digital image processing technique which is able to be used for getting the velocity vector distribution of a surface of the spilt oil in the ocean without contacting the flow itself. This technique is based upon the PIV(Particle Imaging Velocimetry) technique and its system mainly consists of a high sensitive camera, a CCD camera, an image grabber, and a host computer in which an image processing algorithm is adopted for velocity vector acquisition. For the acquisition of the advective velocity vector of floating matters on the ocean, a new multi-frame tracking algorithm is proposed, and for the acquisition of the diffusion velocity vector distribution of the spilt oil onto the water surface, a high sensitive gray-level cross-correlation algorithm is proposed.

  • PDF

Development of 3-D Volume PIV (3차원 Volume PIV의 개발)

  • Choi, Jang-Woon;Nam, Koo-Man;Lee, Young-Ho;Kim, Mi-Young
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.6
    • /
    • pp.726-735
    • /
    • 2003
  • A Process of 3-D Particle image velocimetry, called here, as '3-D volume PIV' was developed for the full-field measurement of 3-D complex flows. The present method includes the coordinate transformation from image to camera, calibration of camera by a calibrator based on the collinear equation, stereo matching of particles by the approximation of the epipolar lines, accurate calculation of 3-D particle positions, identification of velocity vectors by 3-D cross-correlation equation, removal of error vectors by a statistical method followed by a continuity equation criterior, and finally 3-D animation as the post processing. In principle, as two frame images only are necessary for the single instantaneous analysis 3-D flow field, more effective vectors are obtainable contrary to the previous multi-frame vector algorithm. An Experimental system was also used for the application of the proposed method. Three analog CCD camera and a Halogen lamp illumination were adopted to capture the wake flow behind a bluff obstacle. Among 200 effective particle s in two consecutive frames, 170 vectors were obtained averagely in the present study.

Development of 3-D Stereo PIV (3차원 스테레오 PIV 개발)

  • Kim Mi-Young;Choi Jang-Woon;Nam Koo-Man;Lee Young-Ho
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2002.11a
    • /
    • pp.19-22
    • /
    • 2002
  • A process of 3-D particle image velocimetry, called here, as '3-D stereo PIV' was developed for the measurement of a section field of 3-D complex flows. The present method includes modeling of camera by a calibrator based on the homogeneous coordinate system, transfromation of oblique-angled image to transformed image, identification of 2-D velocity vectors by 2-D cross-correlation equation, stereo matching of 2-D velocity vectors of two cameras, accurate calculation of 3-D velocity vectors by homogeneous coordinate system and finally 3-D animation as the post processing. In principle, as two frame images only are necessary for the single instantaneous analysis of a section field of 3-D flow, more effective vectors are obtainable contrary to the previous multi-frame vector algorithm. An experimental system was also used for the application of the proposed method. Three analog CCD cameras and an Argon-Ion Laser(300mW) for illumination were adopted to capture the wake flow behind a bluff obstacle.

  • PDF

PIV System for the Flow Pattern Anaysis of Artificial Organs ; Applied to the In Vitro Test of Artificial Heart Valves

  • Lee, Dong-Hyeok;Seh, Soo-Won;An, Hyuk;Min, Byoung-Goo
    • Journal of Biomedical Engineering Research
    • /
    • v.15 no.4
    • /
    • pp.489-497
    • /
    • 1994
  • The most serious problems related to the cardiovascular prothesis are thrombosis and hemolysis. It is known that the flow pattern of cardiovascular prostheses is highly correlated with thrombosis and hemolysis. Laser Doppler Anemometry (LDA) is a usual method to get flow pattern, which is difficult to operate and has narrow measure region. Particle Image Velocimetry (PIV) can solve these problems. Because the flow speed of valve is too high to catch particles by CCD camera, high-speed camera (Hyspeed : Holland-Photonics) was used. The estimated maximum flow speed was 5m/sec and maximum trackable length is 0.5 cm, so the shutter speed was determined as 1000 frames per sec. Several image processing techniques (blurring, segmentation, morphology, etc) were used for the preprocessing. Particle tracking algorithm and 2-D interpolation technique which were necessary in making gridrized velocity pronto, were applied to this PIV program. By using Single-Pulse Multi-Frame particle tracking algorithm, some problems of PIV can be solved. To eliminate particles which penetrate the sheeted plane and to determine the direction of particle paths are these solving methods. 1-D relaxation fomula is modified to interpolate 2-D field. Parachute artificial heart valve which was developed by Seoul National University and Bjork-Shiely valve was testified. For each valve, different flow pattern, velocity profile, wall shear stress and mean velocity were obtained.

  • PDF

A Research on the Vector Search Algorithm for the PIV Flow Analysis of image data with large dynamic range (입자의 이동거리가 큰 영상데이터의 PIV 유동 해석을 위한 속도벡터 추적 알고리즘의 연구)

  • Kim Sung Kyun
    • 한국전산유체공학회:학술대회논문집
    • /
    • 1998.11a
    • /
    • pp.13-18
    • /
    • 1998
  • The practical use of the particle image velocimetry(PIV), a whole-field velocity measurement method, requires the use of fast, reliable, computer-based methods for tracking velocity vectors. The full search block matching, the most widely studied and applied technique both in area of PIV and Image Coding and Compression, is computationally costly. Many less expensive alternatives have been proposed mostly in the area of Image Coding and Compression. Among others, TSS, NTSS, HPM are introduced for the past PIV analysis, and found to be successful. But, these algorithms are based on small dynamic range, 7 pixels/frame in maximum displacement. To analyze the images with large displacement, Even and Odd field image separation and a simple version of multi-resolution hierarchical procedures are introduced in this paper. Comparison with other algorithms are summarized. A Results of application to the turbulent backward step flow shows the improvement of new algorithm.

  • PDF

PIV Measurement of Natural Convection in a Square Partitioned Enclosure (격판이 존재하는 정사각형 밀폐공간내의 자연대류에 대한 PIV 계측)

  • Kim, Kwang-Hee;Kim, You-Gon
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.708-713
    • /
    • 2001
  • The paper presented some results of a experimental study of natural convection in partitioned 2D square enclosure. The square enclosure consist of two adiabatic vertical walls and the upper cold and the lower hot walls. A partition is positioned perpendicularly at the center of left vertical insulated wall The PIV mesaurements were performed with the variations of the partition length and inclination of enclosure. The working fluid is water with a Prandtl number of 6.996 at $20^{\circ}C$ temperature. A captured images were calculated by using a Cross-Correlation(Multi-frame/Single-exposure) method.

  • PDF