• 제목/요약/키워드: Multi-Conductors

검색결과 57건 처리시간 0.021초

Analysis of the local superconducting properties in YBCO coated conductors with striations

  • Kim, Muyong;Park, Sangkook;Park, Heeyeon;Ri, Hyeong-Cheol
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제17권2호
    • /
    • pp.25-30
    • /
    • 2015
  • In order to realize economical applications, it is important to reduce the ac loss of 2G high-temperature superconductor coated conductors. It seems to be reasonable that a multi-filamentary wire can decrease the magnetization loss. In this study, we prepared two samples of YBCO coated conductors with striations. We measured local superconducting properties of both samples by using Low Temperature Scanning Laser and Hall Probe Microscopy (LTSLHPM). The distribution of the local critical temperature of samples was analyzed from experimental results of Low Temperature Scanning Laser Microscopy (LTSLM) near the superconducting transition temperature. According to LTSLM results, spatial distributions of the local critical temperature of both samples are homogeneous. The local current density and the local magnetization in samples were explored from measuring stray fields by using Scanning Hall Probe Microscopy (SHPM). From SHPM results, the remanent field pattern of the one bridge sample in an external magnetic field confirms the Bean's critical state model and the three bridge sample has similar remanent field pattern of the one bridge sample. The local magnetization curve in the three bridge sample was measured from external fields from -500 Oe to 500 Oe. We visualized that the distribution of local hysteresis loss are related in the distribution of the remanent field of the three bridge sample. Although the field dependence of the critical current density must be taken into account, the relation of the local hysteresis loss and the remanent field from Bean's model was useful.

적응요소 MLFMA를 이용한 유전체가 포함된 3차원 구조의 정전용량계산 (A fast capacitance extraction algorithm for multiple 3-dimensional conductors with dielectrics using adaptive triangular mesh)

  • 김한;안창회
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2001년도 종합학술발표회 논문집 Vol.11 No.1
    • /
    • pp.140-144
    • /
    • 2001
  • This paper describes to extend the MLFMA(Multi-Level Fast Multipole Algorithm) for three-dimensional capacitance computation in the case of conductors embedded in an arbitrary dielectric medium. The triangular meshes are used and refined in the area which has heavy charge density. This technique is applied to the capacitance extraction of three-dimensional structures with multiple dielectrics. The results show good convergence with the comparable accuracy, and this adaptive technique coupled with MLFMA is useful to reduce computing time and the number of elements without additional computational efforts in large three dimensional problems.

  • PDF

Longitudinal reaction on conductors due to tornado wind load

  • Dingyu Yao;Ashraf El Damatty
    • Wind and Structures
    • /
    • 제38권4호
    • /
    • pp.325-339
    • /
    • 2024
  • The longitudinal force resulting from tornado loads on transmission line is considered a crucial factor contributing to the failure of transmission line structures during tornado events. Accurate estimation of this longitudinal force poses a challenge for structural designers. Therefore, the objective of this paper is to provide a set of charts that can be easily used to estimate the peak longitudinal forces transferred from the conductors to a tower. The critical wind field and corresponding configuration considered in this paper are previously studied and determined. The charts should account for all the conductor parameters that can affect the value of the longitudinal force. In order to achieve that, a parametric study is first conducted to assess the variation of the longitudinal forces with different conductor parameters, based on the critical tornado configuration. Results of this parametric study are used to develop the charts that can be used to calculate longitudinal forces by adopting a multi-variable line regression. The forces calculated from charts are validated by finite element analysis. An example for the usage of the charts is provided at the end of this paper.

YBCO CC와 BSCCO Tape의 적층에 따른 자화손실 특성비교 (Comparison Magnetization Losses of the multi-stacked YBCO Coated conductor and the BSCCO tapes)

  • 임형우;이희준;차귀수;이지광
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제7권3호
    • /
    • pp.13-16
    • /
    • 2005
  • Multi-stacked HTS tapes are needed to conduct large current in the power application. In this paper magnetization losses of the multi-stacked YBCO coated conductor and the BSCCO tape have been measured and compared. Magnetization losses of single tape, 2-stacked, 3-stacked and 4-stacked HTS tapes have been presented in this paper. Multi-stacked tapes have been fabricated using face-to-face type stacking method. Measurements of magnetization loss were performed under various stacked of external magnetic field to consider the anisotropic characteristics of HTS tapes. Test results show that loss density per unit volume decreased for both YBCO coated conductors and BSCCO tapes when the stacking number of tapes is increased. As the external magnetic field decreased, the ratio of decrement has risen because the full penetration magnetic field(Bp) of the multi-stacked tape is larger than that of the single tape.

YBCO Coated Conducor와 BSCCO tape의 적층 및 외부자장의 각도에 따른 자화손실 특성 (The Magnetization Losses Characteristics of Multi-stacked and Variable Angle of External Magnet Field in YBCO CC and BSCCO tape)

  • 임형우;이희준;차귀수
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제7권3호
    • /
    • pp.34-38
    • /
    • 2005
  • Multi-stacked HTS tapes are needed to conduct large current in the power application. In this paper, magnetization losses of the multi-stacked YBCO coated conductor and the BSCCO tape have been measured and compared. Magnetization losses of single tape, 2-stacked, 3-stacked and 4-stacked HTS tapes have been presented in this paper. Multi-stacked tapes have been fabricated using face-to-face type stacking method. Measurements of magnetization loss were performed under various angle of external magnetic field to consider the anisotropic characteristics of HTS tapes. Test results show that loss density per unit volume decreased for both YBCO coated conductors and BSCCO tapes when the stacking number of tapes is increased. The magnetization losses of YBCO CC are larger than those of BSCCO tapes when the external magnetic field is increased.

22.9[kV] 다중접지 배전계통에서 고장전류의 접지저항 영향 분석 (The Effect by Grounding Resistance of the ground Fault in the 22.9[kV] Multi-ground Distribution System)

  • 정금영;최선규;심건보;김경철
    • 조명전기설비학회논문지
    • /
    • 제24권10호
    • /
    • pp.85-89
    • /
    • 2010
  • During a ground fault the maximum fault current and neutral to ground voltage will appear at the pole nearest to the fault. Distribution lines are consisted of three phase conductors, an overhead ground wire and a multi-grounded neutral line. In this paper phase to neutral faults were staged at the specified concrete pole along the distribution line and measured the ground fault current distribution in the ground fault current, three poles nearest to the fault point, overhead ground wire and neutral line. A effect by grounding resistance of poles of ground fault current in the 22.9[kV] multi-ground distribution system. by field tests.

Multi-Strand HTS 케이블에서의 전류 불균일 분포 (Non-Uniform Current Distribution of Multi-Strand HTS Cable)

  • Bae, Joon-Han;Bae, Duck-Kweon;Cho, Jeon-Wook;Sim, Ki-Deok;Kim, Hae-Jong;Seong, Ki-Chul;Ko, Tae-Kuk
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.254-259
    • /
    • 2003
  • The 4-probe method with a voltage tap on terminals has been used for the measurement of the critical current of multi-strand high-Tc superconducting (HTS) cables. And the critical current of cables is obtained as the measured total current divided by the number of conductor when the terminal voltage exceeds the predetermined criterion of critical current. However, because of the non-uniform current distribution due to the different critical current, shapes, and other characteristics of each conductor this is not applicable method to the multi-strand HTS cable. To determine the critical current of multi-strand HTS cable the critical current of each conductor must be measured with different method. In this paper, the current distribution and the critical current of each conductor in multi-strand cable were measured with specially made pick-up coils and voltage taps. It is presented that the real critical current of multi-strand is smaller than sum of each conductors. The main cause of non-uniform current distribution is the different resistances appeared in each HTS wires.

  • PDF

적층 수에 따른 YBCO 선재의 전송전류 손실 특성 (Characteristic of Transport Current Losses of Multi-Stacked YBCO Coated Conductors)

  • 한병욱;임희현;강명훈;임형우;차귀수;이희준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.599-600
    • /
    • 2006
  • Multi-slacked HTS tapes are needed to conduct large current in the power application of superconducting machine. This paper deals with the transport current loss of multi-stacked YBCO coated conductor. YBCO coated conductor that was used in this experiment has two Cu layers above and below of YBCO layer for stabilization. Transport losses of four different stacks, single, 2 stack, 3 stack and 4 stack, were measured. Measured results were compared analytic equation suggested by Norris.

  • PDF

적층 수에 따른 YBCO 선재의 전송전류 손실 특성 (Characteristic of Transport Current Losses of Multi-Stacked YBCO Coated Conductors)

  • 한병욱;임희현;강명훈;임형우;차귀수;이희준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 D
    • /
    • pp.2231-2232
    • /
    • 2006
  • Multi-stacked HTS tapes are needed to conduct large current in the power application of superconducting machine. This paper deals with the transport current loss of multi-stacked YBCO coated conductor. YBCO coated conductor that was used in this experiment has two Cu layers above and below of YBCO layer for stabilization. Transport losses of four different stacks, single, 2 stack, 3 stack and 4 stack, were measured. Measured results were compared analytic equation suggested by Norris.

  • PDF

Overview of MgB2 superconducting conductors at Sam Dong in Korea

  • Choi, Jun Hyuk;Lee, Dong Gun;Kim, Du Na;Yoon, Gi Yeong;Jeon, Ju Heum
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제22권2호
    • /
    • pp.32-37
    • /
    • 2020
  • Sam Dong Co., Ltd. has been succeeded in producing a 1 km multi-filament conductor in 2018. So far, we become more widespread to fabricate a variety of customized multi-filament wires such as 6 + '1' Cu, 18 + '1' Cu, and 36 + '1' Cu. In this work, we discuss the research progress on various MgB2 wires over the past three years. We also provide a brief review for applications with our wires.