• Title/Summary/Keyword: Multi-Channel Detector

Search Result 97, Processing Time 0.045 seconds

Under the fading channel environment, performance evaluation of AF CR loop Due to the quantization effect (페이딩 채널 환경하에서의 양자화 특성에 의한 AF CR loop의 성능평가)

  • 송재철;이경하;김선형;최형진
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.3
    • /
    • pp.737-746
    • /
    • 1996
  • In this paper, we present simulation result of quantization effects about a new Angular From Carrier Recovery Loop(AF CR loop) for PSK modulation technique. AF CR loop includes detected angle symbol and Multi Level hardimiter. In general, detected angle is used in dtermining symbol. Because detected angle is used to make an error signal of phase detector output, hardware implementation of AF CR loop is simpler than that of other loops. Before hardware implementation of AF CR loop, the result due to quantization effect should be investigated. In order to confirm quntization effect of AF CR loop, we evaluate performance of this loop by Monte-Carlosimulation method. Under both in the AWGN and Jake's fading noise channel environments, we confirmed the characteristics of AF CR loop in terms of RMS jitter due to quntization effect. Differential APSK modulation schemeis used in this paper. Especially, Jake's fading channel is used as a channel model and also AGC(Automatic Gain Control) is used in the overall process of performance evaluation. We obtained the resonable result of quantization effect about AF CR loop. With the result of performanceevaluation based on quantization effects, we can expect to operate AF CRloop under the fading channel environments reasonably well.

  • PDF

Experimental Performance Evaluation of MIMO Underwater Acoustic Communication in Water Tank (수조에서 MIMO 수중음향통신의 실험적 성능 고찰)

  • Gwun, Byung-Chul;Kim, Ki-Man
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.7
    • /
    • pp.1577-1582
    • /
    • 2013
  • In this paper, we have analyzed the performance of MIMO (Multi-Input Multi-Output) underwater acoustic communication by using the acquired data via the experiments in water tank. First of all, in the pursuit of this aim, we have measured the channel transfer characteristics at several transceiver locations. The transmitted signal was modulated by QPSK(Quadrature Phase Shit Keying) and the received signal was recovered through the detector that contains the zero forcing equalizer. A maximum 30~40 ms delay was appeared because of physically closed water tank environment that has the harsh multi-path transmission conditions. In result of experiment, even though the bit error rate showed comparatively large when $2{\times}2$ MIMO system with two transmitters and receivers was considered. However, we confirmed it has approximately 15% enhanced performance compared with SISO (Single-Input Single-Output) system.

Multi-channel analyzer based on a novel pulse fitting analysis method

  • Wang, Qingshan;Zhang, Xiongjie;Meng, Xiangting;Wang, Bao;Wang, Dongyang;Zhou, Pengfei;Wang, Renbo;Tang, Bin
    • Nuclear Engineering and Technology
    • /
    • v.54 no.6
    • /
    • pp.2023-2030
    • /
    • 2022
  • A novel pulse fitting analysis (PFA) method is presented for the acquisition of nuclear spectra. The charging process of the feedback capacitor in the resistive feedback charge-sensitive preamplifier is equivalent to the impulsive pulse, and its impulse response function (IRF) can be obtained by non-linear fitting of the falling edge of the nuclear pulse. The integral of the IRF excluding the baseline represents the energy deposition of the particles in the detector. In addition, since the non-linear fitting process in PFA method is difficult to achieve in the conventional architecture of spectroscopy system, a new multi-channel analyzer (MCA) based on Zynq SoC is proposed, which transmits all the data of nuclear pulses from the programmable logic (PL) to the processing system (PS) by high-speed AXI-Stream in order to implement PFA method with precision. The linearity of new MCA has been tested. The spectrum of 137Cs was obtained using LaBr3(Ce) scintillator detector, and was compared with commercial MCA by ORTEC. The results of tests indicate that the MCA based on PFA method has the same performance as the commercial MCA based on pulse height analysis (PHA) method and excellent linearity for γ-rays with different energies, which infers that PFA method is an effective and promising method for the acquisition of spectra. Furthermore, it provides a new solution for nuclear pulse processing algorithms involving regression and iterative processes.

Application of an Energy Sensitive CZT Detector to a DXA Type of Bone Densitometer

  • Yoon, Je-Woong;Lee, Hyung-Koo;Lee, Heung-Kyu
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.422-424
    • /
    • 2002
  • The accuracy of DXA(Dual Energy X-ray Absorptiometry) highly depends on the detection and separation capability of dual energy X-ray X-ray photons. In addition both of scan time and patient exposure are affected by detection efficiency. A CZT detector with a good energy resolution and high detection efficiency was evaluated for the application of bone densitometry. Its performance was compared to a photomultiplier tube with a NaI(T1) scintillator in terms of energy resolution, detection efficiency and the accuracy of bone mineral density measurement. The comparison study was performed with CZT detector and PM tube using DXA equipments(OSTEO Plus, OSTEO Prima, ISOL Technology). The energy spectrum was acquired using MCA(Multi-Channel Analyzer). The used X-ray energy ranged from 20keV to 86keV. The MCA result of the CZT detector showed a slightly sharper energy spectrum than that of NaI(T1). Detection efficiency of the CZT detector at 59.5keV was 1.4 times better. Remarkably the final results of bone mineral density measurements demonstrate only less than 1% difference. The CZT detector appears to have many benefits for the application of bone densitometry. Its excellent energy resolution can enhance the counting accuracy of dual energy X-ray spectrum. Furthermore its compactness in physical dimension and no cooling requirement will be additional benefits for a more compact and accurate bone densitometer.

  • PDF

Multi-Valued Image Entropy Coding for input-width reduction of LCD source drivers

  • Sasaki, Hisashi;Arai, Tooru;Hachiuma, Masayuki;Masuko, Akira;Taguchi, Takashi
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.149-152
    • /
    • 2004
  • A new joint source channel coding reduces both input-width and average current consumption to transmit image data to LCD source drivers. As a source coding, it is based on entropy coding of differential pulse code modulation scheme, especially using median edge detector of image predictor. As a channel coding, it is not a simple pulse amplitude modulation, but linked by source entropy to reduce average amplitude. Simulation results show 1/4 width is achievable by 16-valued transmission with keeping conventional current consumption (0.36 to 1.3).

  • PDF

Performance Analysis of the Multi-User Detector Employing a Hybrid Interference Cancellation Scheme in a WCDMA System (WCDMA 시스템에서 Hybrid Interference Cancellation 기법을 적용한 다중사용자 검파기의 성능분석)

  • 서정욱;오창헌;장은영;조성준
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.6 no.2
    • /
    • pp.221-227
    • /
    • 2002
  • In this paper, in order to know the effect of the interference, we have analyzed the BER (Bit Error Rate) performance of the MUD(Multi-User Detector) employing HIC(Hybrid Interference Cancellation) scheme for the asynchronous WCDMA system based on 3GPP(3rd Generation Partnership Project) Spec. through the In this paper, in order to know the effect of the interference, we have analyzed the BER (Bit Error Rate) performance of the MUD(Multi-User Detector) employing HIC(Hybrid Interference Cancellation) scheme for the asynchronous WCDMA system based on 3GPP(3rd Generation Partnership Project) Spec. through the computer simulation. we have assumed Rayleigh fading channel. And we have compared its BER performance with SIC's(Successive Interference Cancellation) and with PIC's(Parallel Interference Cancellation), which are the representative schemes in the subtractive interference cancellation. From the results, it is shown that PlC or HIC is effective for high data-rate users and SIC of HIC for low data-rate users to eliminate the interference. Regardless of the data rate, it is reasonable to use the HIC structure for WCDMA system to satisfy all of users' services. The reason is that the SIC scheme in front of HIC can guarantee the performance of low power users to cancel the serious interference caused by the high power users, while PIC in the rear of it can guarantee the performance of high power users to cancel the interference caused by the low power users.

Novel Laser Ultrasonic Receiver for Industrial NDE

  • Pouet, B.;Breugnot, S.;Clemenceau, P.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.6
    • /
    • pp.380-389
    • /
    • 2006
  • A new laser-based ultrasonic receiver that is based on multi-channel interferometry is shown to be well suited for robust and sensitive detection of ultrasound in industrial environment. The proposed architecture combines random-quadrature detection with detector arrays and parallel multi-speckle processing. The high sensitivity is reached, thanks to the random phase distribution of laser speckle caused by surface roughness. High-density parallel signal processing is achieved by using a simple demodulation technique based on signal rectification. This simple detection scheme is also demonstrated for rejection of the laser intensity noise, making possible the use of lower cost laser without reduction in performances. Results demonstrating this new principle of operation and its performances are presented.

Block-Ordered Layered Detector for MIMO-STBC Using Joint Eigen-Beamformers and Ad-Hoc Power Discrimination Scheme

  • Lee Won-Cheol
    • Journal of Communications and Networks
    • /
    • v.8 no.3
    • /
    • pp.275-285
    • /
    • 2006
  • Suitable for multi-input multi-output (MIMO) communications, the joint beamforming space-time block coding (JBSTBC) scheme is proposed for high-speed downlink transmission. The major functionality of the scheme entails space-time block encoder and joint transmit and receive eigen-beamformer (EBF) incorporating with block-ordered layered decoder (BOLD), and its operating principle is described in this paper. Within these functionalities, the joint EBFs will be utilized for decorrelating fading channels to cause an enhancement in the spatial diversity gain. Furthermore, to fortify the capability of layered successive interference cancellation (LSIC) in block-ordered layered decoding process, this paper will develop a simple ad-hoc transmit power discrimination scheme (TPDS) based on a particular power discrimination function (PDF). To confirm the superior behavior of the proposed JBSTBC scheme employing ad-hoc TPDS, computer simulations will be conducted under various channel conditions with the provision of detailed mathematical derivations for clarifying its functionality.

Monte-carlo Simulation for X-ray Photon Counting using MPPC Arrays (배열형 실리콘광증배소자를 이용한 포톤 카운팅 검출기 설계를 위한 몬테칼로 시뮬레이션 연구)

  • Lee, Seung-Jae;Baek, Cheol-Ha
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.929-934
    • /
    • 2018
  • Studies for counting and detecting X-rays for the improvement of image quality and material analysis are active. In this work, the detector for X-ray photon counting was designed using Multi-pixel photon counter (MPPC) array and the detector characteristics were evaluated through simulation. Geant4 Application for Tomographic Emission (GATE) was used to obtain the position where the X-ray and the scintillation interacted, and this position was used as the light generation position of DETECT2000. 0.5 mm and 1 mm thick Gadolinium Aluminium Gallium Garnet (GAGG) scintillators were used and the light generated through a $4{\times}4$ array of MPPCs was acquired. The spatial resolution of the designed detector was evaluated by reconstructed image using the light signal acquired for each channel. We obtained images of more than 2 lp/mm in both 0.5 mm and 1 mm thick GAGG scintillation. When this detector is used in a X-ray system, a low-cost system capable of photon counting can be made.

A Study on Signal Analysis of the Data Aquisition System for Photosensor (데이터 획득장치에 이용되는 포토센서에 대한 DAS의 신호분석연구)

  • Hwang, InHo;Yoo, Sun Kook
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.10 no.3
    • /
    • pp.237-242
    • /
    • 2016
  • The major advantage of slip-ring technology in Spiral CT is that it facilitates continuous rotation of the x-ray tube, so that volume data can be acquired from a patient quickly. Not only for such a fast scan, but also for the dose reduction purpose, high signal-to-noise ratio and fast data acquisition system is required. In this study, we have built a multi-channel photodetector and multi-channel data acquisition system for CT application. The detector module consisted of CdWO4 crystal and Si photodiode in 16 channels. For the performance test of the preamplifier stage, both the transimpedance and switched integrator types are optimized for the photodetector modules. Switched integrator showed better noise performance in the limited bandwidth which is suitable for the current CT application. The control sequence for data acquisition and 20 bit ADC is designed with VHDL(Very High Speed Integrated Circuit Hardware Description Language) and implemented on FPGA(Field Programmable Gate Array) chip. Our Si photodiode detector module coupled to CdWO4 crystal showed comparable signal with other commercially available photodiode for CT. Switched integrator type showed higher SNR but narrower bandwidth compared to transimpedance preamplifier. Digital hardware is designed by FPGA, so that the control signal could be redesigned without hardware alteration.