• Title/Summary/Keyword: Multi-Blade

Search Result 211, Processing Time 0.024 seconds

On the Free Vibration Analysis of Thin-Walled Box Beams having Variable Cross-Sections (단면형상이 변하는 박판보의 진동해석에 관한 연구)

  • Lee, Gi-Jun;Sa, Jin-Yong;Kim, Jun-Sik
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.30 no.2
    • /
    • pp.111-117
    • /
    • 2017
  • In this paper, a local deformation effect in thin-walled box beams is investigated via a finite element modal analysis. The analysis is carried out for single-cell and multi-cell box beam configurations. The single-cell box beam with and without a neck, which mimics a simple wind-turbine blade, is analyzed first. The results obtained by shell elements are compared to those of one-dimensional(1D) beam elements. It is observed that the wall thickness plays a crucial role in the natural frequencies of the beam. The 1D beam analysis deviates from the shell analysis when the wall thickness is either thin or thick. The shell modes(local deformations) are dominant as it becomes thin, whereas the shear deformation effects are significant as it does thick. The analysis is extended to the single-cell box beam with a neck, in which the shell modes are confined to near the neck. Finally the multi-cell box beam with a taper, which is quite similar to real wind-turbine blade configuration, is considered to investigate the local deformation effect. The results reveal that the 1D beam analysis cannot match with the shell analysis due to the local deformation, especially for the lagwise frequencies. There are approximately 5~7% errors even if the number of segments is increased.

Estimation of Cavitation Bubble Distribution Using Multi-Frequency Acoustic Signals (다중 주파수를 이용한 캐비테이션 기포의 분포량 추정)

  • Kim, Dae-Uk;La, Hyoung-Sul;Choi, Jee-Woong;Na, Jung-Yul;Kang, Don-Hyug
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.3
    • /
    • pp.198-207
    • /
    • 2009
  • Distribution of cavitation bubbles relative to change of the sound speed and attenuation in the water was estimated using acoustic signal from 20 to 300 kHz in two cases that cavitation bubbles exist and do not exist. To study generation and extinction property of cavitation bubble, bubble distribution was estimated in three cases: change of rotation speed (3000-4000 rpm), surface area of blade ($32-98\;mm^2$) and elapsed time (30-120 sec). As a result, the radii of the generated bubbles ranged from 10 to $60{\mu}m$, and bubble radius of $10-20{\mu}m$ and $20-30{\mu}m$ was accounted for 45 and 25% of the total number of cavitation bubbles, respectively. And generation bubble population correlated closely with the rotating speed of the blades but did not correlate with the surface area of blade. It was observed that 80% of total bubble population disappeared within 2 minutes. Finally, acoustic data of bubble distribution was compared with optical data.

Experimental Research on Aerodynamic Instabilities in a Multi Stage Transonic Axial Compressor (다단 천음속 압축기의 유동 불안정성에 관한 실험적 연구)

  • Kang, Young-Seok;Park, Tae-Choon;Hwang, Oh-Sik;Lim, Hyung-Soo;Yang, Soo-Seok
    • The KSFM Journal of Fluid Machinery
    • /
    • v.15 no.2
    • /
    • pp.12-19
    • /
    • 2012
  • This study presents unsteady and unstable characteristics of three stage transonic axial compressor, developed by Korea Aerospace Research Institute. As approaching to the unstable operating region at the 103% design speed of the compressor, a modal type stall precursor appears in front of highly loaded 3rd rotor row at first, and it propagates to the upstream. On the contrary, actual stall cell initiates from the stall precursor in front of the 1st rotor row, and it propagates to the downstream of the compressor. After the stall region reached the 3rd stage and stall cell rotates circumferentially about 360 deg, it develops to one dimensional compressor surge mode. It shows a mild surge behaviour with 3~4 Hz frequency. From the test data, it can be suggested that there is a priority to give an optimum blade loading distributions to construct a multi stage transonic axial compressor stages either to secure more stable compressor operating ranges, or to maximize the compressor efficiency.

Optimization of the multi-chamber perforated muffler for the air processing unit of the fuel cell electric vehicle (연료전지 자동차용 흡기 소음기의 설계 변수 최적화에 관한 연구)

  • Kim, Eui-Youl;Kim, Min-Soo;Lee, Sang-Kwon;Seo, Sang-Hoon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.342-350
    • /
    • 2009
  • Fuel cells convert a fuel together with oxygen in a highly efficient electrochemical reaction to electricity and water. Since the electrochemical reaction in the fuel cell stack dose not generate any noise, Fuel cell systems are expected to operated much quieter than combustion engines. However, the tonal noise and the broad band noise caused by a centrifugal compressor and an electric motor cause which is required to feed the ambient air to the cathode of the fuel cell stack with high pressure. In this study, the multi-camber perforated muffler is used to reduce noise. We propose optimized muffler model using an axiomatic design method that optimizes the parameters of perforated muffler while keeping the volume of muffler minimized.

  • PDF

Multi Layer Coating에서의 품질 영향인자에 대한 고찰

  • 김영권;곽상효;이경현;정종국
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2001.04a
    • /
    • pp.78-78
    • /
    • 2001
  • 현재 Lab Coating은 실험의 정확성 및 재현성을 위해 기존의 Hand Coating에서 탈피하여 Mayor Coater나 CLC(Cylindrical Laboratory Coated) 등을 사용하여 주로 진행된다. Lab Coater로는 현재 가장 진보된 장비라고 할 수 있는 CLC의 경우 속도와 metering 방식 등에서 현장과 유사한 조건을 재현할 수 있다. 그러나 CLC를 사용하여 Multi Layer C Coating을 실시할 경우 원하는 도공량을 얻기 위해서는 상당한 시간과 노력이 필요하며 특히 Triple Coating의 경 우는 더 힘 든 과정 을 거 쳐 야 한다. 그래서 본 연구에서는 도공량 변화 및 Color Formulation 변경에 의한 물성변화를 측정 하여 Triple Coating에서 두 인자가 각각의 품질에 미치는 영향을 비교 분석하여 어느 정도 도공량 변화가 Color Formulation 변화에 상응하는 영향을 주는지를 파악하고자 하였다.코팅은 CLC 6000을 이용하여 실시하였으며, rod와 blade를 사용한 Triple coating을 5가 지 경우의 Color Formulation에 대하여 실시하였다. 변화시켜 코팅한 후 도공량에 따른 백지물성 관계를 분석한 결과 백색도, 평활도, 거칠음도, 투 기도,2도 trap, Set-Off, Dr${\gamma}$ pick은 총도공량과 강한 상관관계를 보였고, 광택도와 K&N은 총도공량보다는 Top 코팅량과 강한 상관 관계를 보였다. 동일한 코팅칼라를 이용하여 인쇄물성을 고찰하였다. 도공량과 물성의 그러나 동일한 코팅칼라를 사용하여 얻어진 일련의 상관성은 Color Formulation이 변경 되었을 경우 전혀 발견할 수 없었다. 즉 Triple Coating에서 코팅칼라 변경이 품질에 미치는 영향은 도공량 변화에 비해 절대적이어서 몇십%의 현을 억제하지는 못한다는 결론을 도출할 수 있었다.

  • PDF

RANS Computation of Turbulent free Surface Flow around a Self Propelled KLNG Carrier (LNG 운반선의 자유수면을 포함한 자항상태 난류유동장의 수치해석)

  • Kim, Jin;Park, Il-Ryong;Kim, Kwang-Soo;Van, Suak-Ho
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.42 no.6 s.144
    • /
    • pp.583-592
    • /
    • 2005
  • The turbulent free surface flow around a self-propelled KRISO 138K LNG Carrier is numerically simulated using the finite volume based multi-block RANS code, WAVIS developed at HRISO. The realizable k-$\varepsilon$ turbulence model with a wail function is employed for the turbulence closure. The free surface is captured with the Level-Set method and body forces are used to model the effects of a propeller without resolving the detail blade flow. In order to obtain an accurate free surface solution and stable convergence, the computations are executed with a proper fine grid refinement around the free surface and with an adoption of implicit discretization scheme for the Level-Set formulation. The computed velocity vectors at the several stations and wave patterns show a good agreement with the experimental results measured at the KRISO towing tank.

A cavitation performance prediction method for pumps: Part2-sensitivity and accuracy

  • Long, Yun;Zhang, Yan;Chen, Jianping;Zhu, Rongsheng;Wang, Dezhong
    • Nuclear Engineering and Technology
    • /
    • v.53 no.11
    • /
    • pp.3612-3624
    • /
    • 2021
  • At present, in the case of pump fast optimization, there is a problem of rapid, accurate and effective prediction of cavitation performance. In "A Cavitation Performance Prediction Method for Pumps PART1-Proposal and Feasibility" [1], a new cavitation performance prediction method is proposed, and the feasibility of this method is demonstrated in combination with experiments of a mixed flow pump. However, whether this method is applicable to vane pumps with different specific speeds and whether the prediction results of this method are accurate is still worthy of further study. Combined with the experimental results, the research evaluates the sensitivity and accuracy at different flow rates. For a certain operating condition, the method has better sensitivity to different flow rates. This is suitable for multi-parameter multi-objective optimization of pump impeller. For the test mixed flow pump, the method is more accurate when the area ratios are 13.718% and 13.826%. The cavitation vortex flow is obtained through high-speed camera, and the correlation between cavitation flow structure and cavitation performance is established to provide more scientific support for cavitation performance prediction. The method is not only suitable for cavitation performance prediction of the mixed flow pump, but also can be expanded to cavitation performance prediction of blade type hydraulic machinery, which will solve the problem of rapid prediction of hydraulic machinery cavitation performance.

Axial-Compressor Design with Mean-line Analysis and Vortex Method (평균유속법과 Vortex 방법을 사용한 축류압축기 설계)

  • Choi, Min-Suk;Yoon, Sugn-Ho;Baek, Je-Hyun
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.795-800
    • /
    • 2001
  • In this study, a program to design a multi-stage axial compressor is developed wi th mean-line analysis and vortex methods. In a preliminary design stage, a method. to design in a short time is needed and mean-line analysis is usually used for this purpose. Arbitrary pressure ratio and reaction can be assigned to generate overall geometry and several vortex methods are adopted to consider the radial distribution of velocity and reaction. The variation of performance, when we use free vortex, forced vortex, and exponential method, is compared and discussed.

  • PDF

New Red Algae of Martensia (Delesseriaceae), M. palmata sp. nov. and M. projecta sp. nov. from Jeju Island, Korea

  • Lee, Yong-Pil
    • ALGAE
    • /
    • v.20 no.4
    • /
    • pp.279-293
    • /
    • 2005
  • Two new species of Martensia (Delesseriaceae, Rhodophyta) are described from Jeju Island, Korea. Martensia palmata sp. nov. is characterized by the following traits: more or less linearly elongated lobes arising from the distal margin of the flabellate membranous section; intact latticework with coarse and loose mesh; numerous spine-like projections on the leading margin of the latticework; tetrasporangia produced in sori along the entire blade; spermatangia borne in sori on the membranous section and the longitudinal lamellae of the latticework; and cystocarps borne on the margins of the membranous section. Martensia projecta sp. nov. has the following characteristics: subdichotomously furcated blades, with terminal segments slightly attenuated toward the apex; blades with uneven surfaces; basal parts with a multi-layered parenchymatous construction; small and poorlydefined latticework; tetrasporangia and spermatangia produced in sori on the membranous section; and cystocarps borne on the marginal surfaces of the blades. The existence of M. projecta sp. nov. supports the proposal that the genus Opephyllum Schmitz in Schmitz et Hauptfleisch should be assigned to the genus Martensia.

Study on Multilayer Chip Inductor (적층 칩 인덕터에 관한 연구)

  • Kim, Kyung-Young;Lee, Jong-Kyu;Kim, Wang-Sup;Choi, Hwan
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.28A no.11
    • /
    • pp.880-886
    • /
    • 1991
  • Multi-layered chip inductors were prepared with good magnetic properties by sintering Ni-Zn-Cu ferrites at a lower temperature. A slurry with 49.5mol%Fe$_{2}O_{3}$, 20.5mol% ZnO, 20mol% NiO and 10nol% CuO was cast into tapes with 60-100\ulcorner of thickness with a doctor blade techniques. The tapes were screen-pronted with 100% silver electrodes, layered and pressed at 250kg/cm$^{2}$ and then sintered ant 900$^{\circ}C$ for 2h. Inductance with internal electrodes printed 5, 10, and 15 turns showed 4.9, 15 and 24$\mu$, respectively, at 1MHz.

  • PDF