• Title/Summary/Keyword: Multi lens

Search Result 207, Processing Time 0.027 seconds

The Effects of Ultrasonic Cleaner for Eye Glasses on Protein Deposits and Parameters in Soft Contact Lens (안경용 초음파세척기에 의한 소프트콘택트렌즈의 단백질 침전물 세척효과)

  • Ju, Eun-Hee;Lee, Koon-Ja;Leem, Hyun-Sung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.227-234
    • /
    • 2010
  • Purpose: The cleaning effect of protein deposit and the change of contact lens parameters by ultrasonic cleaner for eye glasses on the soft contact lenses were investigated. Methods: Etafilcon A contact lenses contaminated with protein, was ultrasonicated by ultrasonic cleaner for eye glasses and for the control group, spoiled contact lenses were cleaned by multi-purpose solution. The remaining protein deposits on the contact lenses were determined after extraction and the changes of overall diameter, base curve, center thickness power, and water contents on contact lenses were measured and surfaces of contact lenses were observed by scanning electron microscope. Results: The cleaning efficacies of multi-purpose solution on protein deposited etafilcon A contact lenses were 6.08%, and 23.73~33.92% in the group of ultrasonic cleaner for eye glasses with multi-purpose solution and 0~12.99% in the group of ultrasonic clear for contact lens with multipurpose solution depending on the treatment time. The changes of parameters and surface on contact lenses by ultrasonication were not observed. Conclusions: Ultrasonic cleaner for eye glasses can be used to eliminate protein deposits for the diagnostic soft contact lens in the office since it was effective to eliminate protein deposits and not caused change of parameters on soft contact lenses.

Development of Array-Lens for Multi-Color Chip-LED (Multi-Color Chip-LED용 어레이 렌즈 개발에 관한 연구)

  • Choi, Byung-Ky;Lee, Dong-Gil;Jang, Kyeung-Cheun
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.16 no.3
    • /
    • pp.50-55
    • /
    • 2007
  • The purpose of this research is to enhance the luminance of the LED and to improve the implementation of color by mounting an array lens on the LED without special technology in process. The workmanship of key components considering the economical efficiency and the injection molding technology for high quality of the product are essential to achieve it. In this paper, the mold was computer-aided was designed and manufactured by CAM software (NX4) and high speed machining center. the applied final machining conditions were 3,000-5,000mm/min feed speed, 15,000-25,000rpm and ${\Phi}0.3mm$ ball end-mill. And the Flow analysis was performed using the mold flow software(MPI) in order to get uniformity of resin. Injection conditions acquired by the flow analysis and the injection experiment are as follows. The cylinder temperature is $220-260^{\circ}C$, the mold temperature is $70-80^{\circ}C$, the injection time is about 1.2sec, the injection pressure and velocity is each 7.8-14.7Mpa, and the injection velocity is 0.8-1.2m/sec.

Design and Development of Asymmetry Glass Array Lens (비축대칭 Glass Array Lens의 설계 및 개발)

  • Park, Soon-Sub;Hwang, Yeon;Lee, Ki-Young;Kim, Geon-Hee;Won, Jong-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.12
    • /
    • pp.39-46
    • /
    • 2008
  • Asymmetric glass lens core for portable projection optic system was designed and simulated. And it was machined by newly developed non-rotational ultra precision grinding method. With the designed lens data which optimized for multi-collimation, we generated the we core surface data. Mold pressing conditions analyzed by FEM. In the machining process, ground profile errors were compensated based on measured data, minimized feed rate and depth of cut. The deviations of machined core profile were acceptable level for glass mold press. Mold pressed glass array lens was coated with $SiO_2\;and\;Ta_2O_5$ for anti-reflection.

A Study on the Promotion of Indirect Light Receiving Efficiency (간접 전파광의 수광 효율 향상에 관한 연구)

  • 허수진;정찬수
    • Journal of Biomedical Engineering Research
    • /
    • v.13 no.3
    • /
    • pp.201-208
    • /
    • 1992
  • In the indirect optical bio-telemetry, high frequency response and low minimum detectable optical power can be achieved by using photodiode with small light receiving area which minimizes junction capacitance. But, on the other hand, S/N ratio becomes low because the optical signal current is small. To solve such a problem, we attach plato-convex lens in front of photo diode, The results of comput- er simulation and experiments suggest promotion of light receiving efficiency and possibility of multi- telemetry system through directivity of convex lens in one room.

  • PDF

A Parallel Mode Confocal System using a Micro-Lens and Pinhole Array in a Dual Microscope Configuration (이중 현미경 구조를 이용한 마이크로 렌즈 및 핀홀 어레이 기반 병렬 공초점 시스템)

  • Bae, Sang Woo;Kim, Min Young;Ko, Kuk Won;Koh, Kyung Chul
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.11
    • /
    • pp.979-983
    • /
    • 2013
  • The three-dimensional measurement method of confocal systems is a spot scanning method which has a high resolution and good illumination efficiency. However, conventional confocal systems had a weak point in that it has to perform XY axis scanning to achieve FOV (Field of View) vision through spot scanning. There are some methods to improve this problem involving the use of a galvano mirror [1], pin-hole array, etc. Therefore, in this paper we propose a method to improve a parallel mode confocal system using a micro-lens and pin-hole array in a dual microscope configuration. We made an area scan possible by using a combination MLA (Micro Lens Array) and pin-hole array, and used an objective lens to improve the light transmittance and signal-to-noise ratio. Additionally, we made it possible to change the objective lens so that it is possible to select a lens considering the reflection characteristic of the measuring object and proper magnification. We did an experiment using 5X, 2.3X objective lens, and did a calibration of height using a VLSI calibration target.

The Comparative Study on the wettability of the RGP lens multi-purpose solutions(MPSs) (RGP lens 다목적용액의 습윤성에 관한 비교 연구)

  • Park, Hyun-Ju;Goe, Eun-Kyung;Seo, Eun-Sun;Kim, Jai-Min;Lee, Ki-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.8 no.2
    • /
    • pp.119-127
    • /
    • 2003
  • We measured the effect of wettability of six MPSs for RGP lens. The used MPSs(multipurpose solutions) were OPTI-SOAK(ALCON), SOLO care hard(CIBA Vision), Total care(ALLERGAN), Simplicity(BOSTON). Wetting and Soaking Sol.(Bausch & Lomb) and Aquas-multi(Saehan). These MPSs keeps hydrophilic property of lens surface and increase the effect of cleaning or increase the effect of preservative effect. To compare with the effect of wettability we followed the way of contact angle measurement which was general way to measure wettability and compared lens which was conducted by each MPS made by different companies. As a control, 0.9% NaCl solution and artificial tears were used. The degree of the effect of wettability was decided by contact angle. It is hydrophilic property nearby $0^{\circ}$ of contact angle and it is closed by hydrophobic property as it increases. To compare with the effect of wettability we followed the way of contact angle measurement which was general way to measure wettability and compared lens which was conducted by each MPS made by different companies. As a control, 0.9% NaCl solution and artificial tears were used. The degree of the effect of wettability was decided by contact angle. It is hydrophilic property nearby $0^{\circ}$ of contact angle and it is closed by hydrophobic property as it increases. The results showed that every lens was nearby hydrophilic property within $25^{\circ}{\sim}36^{\circ}$. Also, it was differed by various factors. The surface tension showed various differences between 19.8 and 31.3(mN/m). In the viscosity, MPSs represented the highest viscosity between $4^{\circ}C$ and $20^{\circ}C$. It was much higher than compared with the viscosity of soft lens MPS. This experiment could be used to grasping the interaction between solutions used to MPS and the natural endowments of lens and to considering the relations of different factors effecting the wettability.

  • PDF

A Study on the Optical Properties of Eye-glasses (안경렌즈의 광학적 성능에 관한 연구)

  • Lim, Hyeon Seen;Ji, Taek Sang;Kim, Bong Hwan
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.2 no.1
    • /
    • pp.31-43
    • /
    • 1997
  • In this paper, the rate of transmittance regarding the home -and foreign-made lens that have been treated with multi coating and no coating has been studied in the range of the visible ray. The lens that were treated with No Coating turned out to be about 93% of the rate of transmittance, but those treated with Coating turned out to be over 98%. Especially, the rate of transmittance of product made by a company in a foreign country turned out to be homogeneous in the whole range.

  • PDF

Design analysis for Head-Up Display by multi-wavelength laser (HUD용 다파장 레이저 광학부품 설계 및 분석)

  • Choi, Hae Woon
    • Laser Solutions
    • /
    • v.17 no.1
    • /
    • pp.17-21
    • /
    • 2014
  • Head up display is in increasing demand for advanced devices in the modern luxury vehicles. It helps drivers focus on driving environment on the road. While HUD technology with LED has advanced, the brightness in daylight can be still an issue to be resolved. Laser light source is a possible solution to overcome the brightness problem and optimal optics design is required for the best performance. Sample design of optics is proposed and detail procedure of lens design evaluation is presented in this paper. The results were characterized by using a ray tracing method and qualitative analysis for spot and DEE is also presented. The overall error or image distortion remained in the target range of $25{\mu}m$ and the simulated image demonstrated possible use in the automotive applications.

  • PDF