• Title/Summary/Keyword: Multi Tier

Search Result 108, Processing Time 0.025 seconds

Partial Offloading System of Multi-branch Structures in Fog/Edge Computing Environment (FEC 환경에서 다중 분기구조의 부분 오프로딩 시스템)

  • Lee, YonSik;Ding, Wei;Nam, KwangWoo;Jang, MinSeok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.26 no.10
    • /
    • pp.1551-1558
    • /
    • 2022
  • We propose a two-tier cooperative computing system comprised of a mobile device and an edge server for partial offloading of multi-branch structures in Fog/Edge Computing environments in this paper. The proposed system includes an algorithm for splitting up application service processing by using reconstructive linearization techniques for multi-branch structures, as well as an optimal collaboration algorithm based on partial offloading between mobile device and edge server. Furthermore, we formulate computation offloading and CNN layer scheduling as latency minimization problems and simulate the effectiveness of the proposed system. As a result of the experiment, the proposed algorithm is suitable for both DAG and chain topology, adapts well to different network conditions, and provides efficient task processing strategies and processing time when compared to local or edge-only executions. Furthermore, the proposed system can be used to conduct research on the optimization of the model for the optimal execution of application services on mobile devices and the efficient distribution of edge resource workloads.

Web-based Building Automation System using Embedded Linux (임베디드 리눅스를 이용한 웹 기반 빌딩자동화시스템)

  • 신은철;이수영;최병욱
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.10 no.4
    • /
    • pp.334-340
    • /
    • 2004
  • In this paper, a Web-based management system for the building network is described. A multi-protocol converter based on SoC and embedded Linux is designed. The open source licensing, reliability, and broad hardware support are key reasons for use of embedded Linux in embedded industry. The multi-protocol converter integrates control network of RS-485 and LonWorks devices through TCP/IP protocol for a client with Java applet. The system consists of three-tier architecture, such as a client, a server that is performed on a multi-protocol converter, and control devices. The developed system includes the inverter motor control system with modbus protocol for the RS-485 network. The experiment results show that the multi-protocol converter using embedded Linux is a flexible and effective way to builda Web -based monitoring and control system.

Compressed Sensing-Based Multi-Layer Data Communication in Smart Grid Systems

  • Islam, Md. Tahidul;Koo, Insoo
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.7 no.9
    • /
    • pp.2213-2231
    • /
    • 2013
  • Compressed sensing is a novel technology used in the field of wireless communication and sensor networks for channel estimation, signal detection, data gathering, network monitoring, and other applications. It plays a significant role in highly secure, real-time, well organized, and cost-effective data communication in smart-grid (SG) systems, which consist of multi-tier network standards that make it challenging to synchronize in power management communication. In this paper, we present a multi-layer communication model for SG systems and propose compressed-sensing based data transmission at every layer of the SG system to improve data transmission performance. Our approach is to utilize the compressed-sensing procedure at every layer in a controlled manner. Simulation results demonstrate that the proposed monitoring devices need less transmission power than conventional systems. Additionally, secure, reliable, and real-time data transmission is possible with the compressed-sensing technique.

LON based Distributed Control System for HVAC (HVAC를 위한 론기반의 분산형 제어기)

  • Choi, Byoung-Wook;Sin, Eun-Cheol
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.535-540
    • /
    • 2003
  • In this Paper, a LON based distributed control system for HVAC is described. We developed multi-protocol converter based on SoC, Neuron Chip, embedded Linux. It utilizes the network environment and therefore requires an appropriate operating system for handling protocols and an advanced development environment. The open source licensing, reliability, and broad hardware support are key reasons for use of embedded Linux in embedded industry. The multi-prootocol converter integrates LonWorks devices to a client with Java applet. The system consists of three-tier architecture, such as clients, multi-protocol converter, and LonWorks devices. The experiment result show that multi-protocol converter using embedded Linux is a flexible and effective way to build a Web-based monitoring and control system.

  • PDF

The Dangerous Distance of Culture and Life (문화와 삶의 위험한 거리)

  • Kim, Cheon-Young
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.1
    • /
    • pp.439-445
    • /
    • 2021
  • This study aims to investigate the distance of culture and life by 'The Relation-Approach.' For this, We identified the path and mechanism of importance of culture and life through the concept of respective distance and closed distance. We found that the structure of closed culture and closed life makes the distance of culture and life dangerous, which is operated as the factor of making dangerous culture and life. This fact shows that respectiveness operates in the process of converting respective distance to closed distance. Also, It was confirmed that the problem of solving dangerous distance can be established in the condition that mutual distance of culture and life can have the possibility of accomplishment. But We found the fact that the distance which is regarded as the true mutual distance having the consistence of the open condition-accomplishment in culture and life is actually operated by making the dangerous path and mechanism. In this point, We suggested the concept of 'The Multi-tier Dangerousness,' not 'The Single-tier Dangerousness.' We also found the importance of dangerousness of perception with a view to resolving dangerousness operating in culture and life. The fact that 'dangerousness of perception' produced 'dangerousness of phenomenon' was identified. Further more, We suggested that intrinsic perception is needed so as to healthy culture and life. And Open perception was emphasized to go to mutual distance beyond respective distance.

Design of Network-based Game Using the GoF Design Patterns

  • Kim Jong-Soo;Kim Tai-Suk
    • Journal of Korea Multimedia Society
    • /
    • v.9 no.6
    • /
    • pp.742-749
    • /
    • 2006
  • In the network-based game where it uses the Internet infrastructure, the implementation is possible with the various methods. Such Applications are developed in the multi-tired architecture. There are many cases for the server to be separated from the hardware or the software. In this case, a lot of applications make the distributed process possible and are made as the multi-tiered architecture to develop the reusability of the existing software module. Especially, it is mostly general to separate for the case of a database server to a new tier. One of the important points of multi-tiered server side applications is security and because of this, it is difficult to share the related data about the design skill. Using design patterns, it gives help in reusing the existing written-code for the design of the game that needs a lot of money and time. Design Patterns are related to the software reuse. For the development of more efficient games, if well-defined design patterns are provided to the developers, then it would make more easy advanced game API and make possible the framework for the game development based on the API Through the analysis of the general network-based game currently servicing in the Internet, in this paper, we discuss how to implement a business logic tier using database system among the server side architectures. The main objective of this article is to show an efficient APIs(Application Programming Interfaces) design method which can be used to manage the data that must be saved to the database system among the packets that client/server have to be exchange.

  • PDF

Capacity Analysis of IEEE802.16j MMR System Using Directional Antenna (지향성 안테나를 사용하는 IEEE802.16j 멀티 홉 릴레이 시스템의 용량 분석)

  • Kim, Seung-Yeon;Yoo, Chang-Jin;Kim, Se-Jin;Ryu, Seung-Wan;Cho, Choong-Ho;Lee, Hyong-Woo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.2B
    • /
    • pp.170-177
    • /
    • 2009
  • In this paper, we propose the structures of the NBTC (Narrow-Beam Trisector Cell) and the WBTC(Wide-Beam Trisector Cell) in which directional antennas both at the base station and at the relay station are used. We analyze and compare total capacity of the both systems taking the co-channel interference into consideration for two channel models. Through analysis, we find the effect of LOS (Lind of Sight) path to the total capacity of NBTC structure and that of WBTC structure. Our work may be useful as a guideline to control the interference for the next generation mobile communication and WiBro systems using multi-hop relays.

An Effective Coverage Extension Scheme for Trisector Cellular Systems using Multi-hop Relay based on IEEE 802.16j (IEEE 802.16j 기반의 중계기를 도입한 3섹터 셀룰러 시스템에서 효율적인 기지국 커버리지 확장 기법)

  • Yoo, Chang-Jin;Kim, Seung-Yeon;Cho, Choong-Ho;Lee, Hyong-Woo;Ryu, Seung-Wan
    • Journal of KIISE:Information Networking
    • /
    • v.37 no.4
    • /
    • pp.294-300
    • /
    • 2010
  • In this paper, We analysis of effective coverage extension for Tri-sector cellular systems using Multi-hop Relay based on IEEE802.16j system. In the proposed international standard of IEEE 802.16j MMR (Mobile Multi-hop Relay) use of the omni-directional antenna, 3-sector and 6-sector antenna is considered to Base Station and Relay Station. Omni-directional antenna service can offer as all directions but a throughput decreases due to the signal interference of near Relay Stations. In the directional antenna, cause of an interference with the base station which it arranges an antenna so that a beam can have the direct and does with neighbor Base Station and Relay Station can be reduced interference, therefore the effective throughput is higher than the omni-directional antenna system. But, In case of Base Station and Relay Station use the directional antenna, the efficiency which the directional antenna has the Co-channel interference due to in the different cell by the channel reuse is decreased. In this study, we propose the structure of arranging the Base Station and Relay Station having the directional antenna in the NBTC, WBTC antenna in a multi-tier. It compared and analyzed with the mode that the multi-hop Relay Station has the omni-directional antenna, Relay Station are used the NBTC antenna and the WBTC antenna system also, We analyze a relation between the performance degradation and the cell coverage extension which it follows because the number of hop in the multi-hop Relay Station.

Study on the Characteristics of Noise/Vibration in the Upright Laying Hen House (직립식 산란계사 내의 소음 진동 발생 현황 조사연구)

  • Lee S.J.;Chang D.I.;Chang H.H.
    • Journal of Animal Environmental Science
    • /
    • v.12 no.1
    • /
    • pp.21-28
    • /
    • 2006
  • This study was carried out to measure and analyze the characteristics of noise and vibration, and to analyze their effects on the productivity of layers, mechanical troubles, and abnormal wear-out failure of facilities and equipment of the layer house. The measurements of noise and vibration were taken at 13 layer farms nationwide for the operations of feed supplier system, feed distribution system, automatic egg collection system, ventilation system, blot conveyer for layer feces, and fur the case of with and without their operation by a sound level meter and a vibration measuring system in the layer house equipped with upright multi-tier cages. Measurement results showed that normal times were noise(N) 82 dB and vibration(V) 0.2072 cm/s, feed supplier system were 90 dB(N) and 2.8560 cm/s(V), feed distribution system were 90 dB(N) and 2.0222 cm/s(V), automatic egg collection system were 87 dB(N) and 0.1865 cm/s(V), ventilation system 88 dB(N) and 2.5364 cm/s(V), belt conveyer fur layer feces were 88 dB(N) and 0.2387 cm/s(V), and then maximum values of noise and vibration were 90 dB and 2.8560 cm/s, respectively, when feeding systems(feed supplying system and feed distribution system) were operated. Based on these results, an experiment is being conducted to find out the effect of noise and vibration on the productivity of layers in the layer house equipped with upright multi-tier cages.

  • PDF

High MSE wall design on weak foundations

  • Mahmoud Forghani;Ali Komak Panah;Salaheddin Hamidi
    • Geomechanics and Engineering
    • /
    • v.36 no.4
    • /
    • pp.329-341
    • /
    • 2024
  • Retaining structures are one of the most important elements in the stabilization of excavations and slopes in various engineering projects. Mechanically stabilized earth (MSE) walls are widely used as retaining structures due to their flexibility, easy and economical construction. These benefits are especially prominent for projects built on soft and weak foundation soils, which have relatively low resistance and high compressibility. For high retaining walls on weak foundations, conventional design methods are not cost-effective. Therefore, two alternative solutions for different foundation weakness are proposed in this research: optimized multi-tiered MSE walls and single tier wall with foundation improvement. The cost optimization considers both the construction components and the land price. The results show that the optimal solution depends on several factors, including the foundation strength and more importantly, the land price. For low land price, the optimized multi-tiered wall is more economical, while for high land price (urban areas), the foundation improvement is preferable. As the foundation strength decreases, the foundation improvement becomes inevitable.