• Title/Summary/Keyword: Mu-Scan

Search Result 242, Processing Time 0.026 seconds

Development of Bladder Phantom and Image Evaluation of Lesion in the Vicinity according to Filling and Empty Bladder (방광 팬텀 제작을 통한 충만여부에 따른 방광 주변 병변에 대한 영상 평가)

  • Park, Chan-Rok;Kim, Jae-Il;Lee, Hong-Jae;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.24-27
    • /
    • 2016
  • Purpose In this study, we evaluated image quality of lesion in the vicinity according filling and empty bladder developing bladder phantom. Materials and Methods Bladder phantom was developed by modifying NEMA IEC body phantom. Air-balloon was described as bladder and 6 insert were set as lesion in the vicinity bladder according to distance. The images were evaluated in terms of % BV, comparison of SUV and peak count rate (Single, Random and True count). Results % BV was decreased far away from bladder. There were different for SUV about $7.8{\pm}3.8%$ between filling and empty bladder. True count rate was decreased about 38 %. Single and random count were increased about 44, 61%. Conclusion When the lesion is close to bladder, noise is increased. That's why prior to PET-CT scan, It is important to urinate. and It helps patient to get the accurate result.

  • PDF

Factors Predicting Early Release of Thyroid Cancer Patients from the Isolation Room after Radioiodine-131 Treatment

  • Fatima, Nosheen;Zaman, Maseeh uz;Zaman, Areeba;Zaman, Unaiza;Tahseen, Rabia;Shahid, Wajiha
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.1
    • /
    • pp.125-129
    • /
    • 2016
  • Background: Patients with differentiated thyroid cancers (DTC) who receive radioactive iodine-131 (RAI) are released from isolation when their dose rate is below the regulatory requirements. The purpose of this study was establish predicting factors for early release from the isolation facility after RAI administration in patients with DTC. Materials and Methods: This was a prospective study which included 96 (58 females and 38 males) patients with DTC who had received RAI from April 2013 till August 2015. The study was duly approved by the ethical committee of the institute. Patients who had complete information of primary tumor size (PTS), serum TSH, stimulated thyroglobulin level [sTg] with antibodies (IU/ml) at the time of RAI treatment were included. All had a normal serum creatinine level. To attain lower effective half-life good hydration and administration of soft laxative were ensured. Dose rate was measured (immediately, 24 h and 36 h) at 1 meter distance from anterior mid trunk and a dose rate <$50{\mu}Sv/h$ was considered as the releasing criterion. At 24 h 50 patients were released while the remaining 46 patients were released at 36 h. A post-ablative whole body scan (PA-WBIS) was performed 5-8 days after RAI ablation in all patients. Results: Patients released after 24 h were significantly younger, had smaller lesions with higher proportion of papillary cancer, lower sTg, lower sTg/TSH ratio and had received a lower dose of RAI as comapred to those who were discharged after 36 h. Serum TSH and gender were not found to have any significant correlation between two cohorts. ROC and multivariate analysis have shown age ${\leq}37years$, PTS ${\leq}3.8cm$, $RAI{\leq}150mCi$, $sTg{\leq}145ng/ml$ and $sTg/TSH{\leq}1.085$ as strong indepedent predictors for early release. Conclusions: We conclude that younger age (${\leq}37years$), smaller tumor size (${\leq}3.8cm$), lower RAI dose (${\leq}150mCi$), lower sTg (${\leq}145ng/ml$) and a lower sTg/TSH ratio (${\leq}1.085$) are significant independent predictors for release at 24 h after RAI treatment in DTC patients. Effective utilization of these factors could help the treating physicians to use limited number of internment facilities with higher throughput, lower cost and lower psychological stress to patients.

A Case of Lung Metastasis of Mesoblastic Nephroma in Adulthood (성인에서 발생한 중배엽성 신종의 폐전이 1예)

  • Moon, Jin Wook;Kim, Kil Dong;Shin, Dong Hwan;Hahn, Chang Hoon;Jung, Jae;Park, Mu Suk;Jung, Sang Youn;Lee, Jae Hyuk;Kim, Young Sam;Kim, Se Kyu;Kim, Sung Kyu;Chang, Joon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.55 no.4
    • /
    • pp.402-407
    • /
    • 2003
  • Mesoblastic nephroma is a neoplasm of the kidney which is characterized by interlacing bundles of spindle mesenchymal cells. It is usually diagnosed during the first six months of life and is mostly benign. Incidence in adults is exceedingly rare. In most cases, only total excision is required without postoperative adjuvant therapy, and the rare cases of local recurrence have usually been related to incomplete removal. However, mesoblastic nephroma may behave aggressively, in contrast to a congenital mesoblastic nephroma. Several cases of metastatic mesoblastic nephroma have been previously described. We report herein a case of a 42-year-old woman with mesoblastic nephroma which recurred as a large metastatic lung mass seven years after the nephrectomy. The patient presented with chest wall discomfort for four days. Seven years previously, total nephrectomy had been performed because of a right renal tumor which had been diagnosed as a mesoblastic nephroma. There had been no evidence of recurrence for five years, after which she discontinued follow-up. On readmission two years later, chest X-ray and CT scan revealed a large lung mass in the left upper lobe. It was completely excised and the pathologic examination was identical with that of the original renal tumor. Synovial sarcoma was excluded because the fusion transcripts of the SYT-SSX fusion gene associated with the t(X;18) translocation were negative. The final diagnosis was a lung metastasis of mesoblastic nephroma and the patient remained free of disease for 7 months postoperatively.

A Case of Cryptococcosis involving Lung and CNS without Underlying Disease (폐와 중추신경계를 침범한 효모균증(Cryptococcosis) 1예)

  • Lee, Min-Su;Park, Sang-Seon;Koh, Young-Il;Jang, An-Soo;Lim, Sung-Chul;Yang, Ju-Yeoul;Park, Hyung-Kwan;Na, Hyun-Joo;Kim, Young-Chul;Choi, In-Seon;Park, Kyung-Ok
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.4
    • /
    • pp.618-623
    • /
    • 1995
  • Cryptococcosis is a systemic mycosis that most often involves the lungs and central nervous system and, less frequently, the skin, skeletal system, and prostate gland. Cryptococcus neoformans, the causative organism, is a yeastlike round or oval fungus, 4 to $6{\mu}m$ in diameter, which is surrounded by a polysaccharide capsule and reproduces by budding and found in soil and other environmental areas, especially those contaminated by pigeon droppings. Humans and animals acquire infection after inhalation of aerosolized spores. Condition or factors that predispose to cryptococcosis include corticosteroid therapy, lymphoreticular malignancies, HIV infection, and sarcoidosis etc. We discribed a case of cryptococcosis involving lung and CNS coincidently without specific underlying disease and the literature on subject were reviewed. A fifty-six year-old previously healthy female presented with headache of 3 months of duration. She had no history suggesting immunologic suppression and we could not find any abnormal laboratory findings including blood sugar, serum immunoglobulin and complement level, HIV antibody, and T cell subsets. Chest roentgenogram and CT scan showed a solitary soft tissue mass in LUL with distal pneumonitis. Brain MRI showed granulomatous lesion in cerebellum and parasagittal cortex of right frontal lobe. The diagnosis was made by bronchoscopic brushing cytology, transthoracic fine needle aspiration, and sputum KOH mount and culture. She was treated 6 weeks course of Amphotericin B and switched to oral fluconazole therapy for 3 months. Her symptoms and X-ray findings were improved gradually and she is now under regular clinical follow up.

  • PDF

Correlation between Microstructure and Mechanical Properties of the Additive Manufactured H13 Tool Steel (적층 제조된 H13 공구강의 미세조직과 기계적 특성간의 상관관계)

  • An, Woojin;Park, Junhyeok;Lee, Jungsub;Choe, Jungho;Jung, Im Doo;Yu, Ji-Hun;Kim, Sangshik;Sung, Hyokyung
    • Korean Journal of Materials Research
    • /
    • v.28 no.11
    • /
    • pp.663-670
    • /
    • 2018
  • H13 tool steels are widely used as metallic mold materials due to their high hardness and thermal stability. Recently, many studies are undertaken to satisfy the demands for manufacturing the complex shape of the mold using a 3D printing technique. It is reported that the mechanical properties of 3D printed materials are lower than those of commercial forged alloys owing to micropores. In this study, we investigate the effect of microstructures and defects on mechanical properties in the 3D printed H13 tool steels. H13 tool steel is fabricated using a selective laser melting(SLM) process with a scan speed of 200 mm/s and a layer thickness of $25{\mu}m$. Microstructures are observed and porosities are measured by optical and scanning electron microscopy in the X-, Y-, and Z-directions with various the build heights. Tiny keyhole type pores are observed with a porosity of 0.4 %, which shows the lowest porosity in the center region. The measured Vickers hardness is around 550 HV and the yield and tensile strength are 1400 and 1700 MPa, respectively. The tensile properties are predicted using two empirical equations through the measured values of the Vickers hardness. The prediction of tensile strength has high accuracy with the experimental data of the 3D printed H13 tool steel. The effects of porosities and unmelted powders on mechanical properties are also elucidated by the metallic fractography analysis to understand tensile and fracture behavior.

The evaluation for the usability ofthe Varian Standard Couch modelingusing Treatment Planning System (치료계획 시스템을 이용한 Varian Standard Couch 모델링의 유용성 평가)

  • Yang, yong mo;Song, yong min;Kim, jin man;Choi, ji min;Choi, byeung gi
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.1
    • /
    • pp.77-86
    • /
    • 2016
  • Purpose : When a radiation treatment, there is an attenuation by Carbon Fiber Couch. In this study, we tried to evaluate the usability of the Varian Standard Couch(VSC) by modeling with Treatment Planning System (TPS) Materials and Methods : VSC was scanned by CBCT(Cone Beam Computed Tomography) of the Linac(Clinac IX, VARIAN, USA), following the three conditions of VSC, Side Rail OutGrid(SROG), Side Rail InGrid(SRIG), Side Rail In OutSpine Down Bar(SRIOS). After scan, the data was transferred to TPS and modeled by contouring Side Rail, Side Bar Upper, Side Bar Lower, Spine Down Bar automatically. We scanned the Cheese Phantom(Middelton, USA) using Computed Tomography(Light Speed RT 16, GE, USA) and transfer the data to TPS, and apply VSC modeled previously with TPS to it. Dose was measured at the isocenter of Ion Chamber(A1SL, Standard imaging, USA) in Cheese Phantom using 4 and 10 MV radiation for every $5^{\circ}$ gantry angle in a different filed size($3{\times}3cm^2$, $10{\times}10cm^2$) without any change of MU(=100), and then we compared the calculated dose and measured dose. Also we included dose at the $127^{\circ}$ in SRIG to compare the attenuation by Side Bar Upper. Results : The density of VSC by CBCT in TPS was $0.9g/cm^3$, and in the case of Spine Down Bar, it was $0.7g/cm^3$. The radiation was attenuated by 17.49%, 16.49%, 8.54%, and 7.59% at the Side Rail, Side Bar Upper, Side Bar Lower, and Spine Down Bar. For the accuracy of modeling, calculated dose and measured dose were compared. The average error was 1.13% and the maximum error was 1.98% at the $170^{\circ}beam$ crossing the Spine Down Bar. Conclusion : To evaluate the usability for the VSC modeled by TPS, the maximum error was 1.98% as a result of compassion between calculated dose and measured dose. We found out that VSC modeling helped expect the dose, so we think that it will be helpful for the more accurate treatment.

  • PDF

Production and Assessing Usefulness of the Moving Phantom for Respiration Gated Radiotherapy (호흡동조 방사선치료용 팬텀의 제작 및 유용성 평가)

  • Lee, Yang-Hoon;Lee, Jae-Hee;Yoo, Suk-Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.2
    • /
    • pp.135-144
    • /
    • 2010
  • Purpose: The purpose of this study is that through production of phantom for respiration gated radiotherapy, assessing appropriacy of exposure dose for the therapy using RPM (Real-time Position Management). Materials and Methods: We located measurement object on the phantom for respiration gated radiotherapy made of 2 linear actuator, acrylic panel, stanchion, iron plate ets. to drive (up, down, front, back). Using 4D CT scan, we analyzed patient's respiration and reproduced the movement by computer. On the phantom, we located a 2D-Array (PTW) and an White water phantom (4.5 cm) and used DMLC (interval 2 cm) in the field size $10{\times}10\;cm$, then exposed 21EX X-ray 100 MU, in the case of phantom was (1) static (2) moving (3) gated using RPM respectively gantry $0^{\circ}$ and $90^{\circ}$ We measured with a 0.125 CC ionization chamber (PTW) on the phantom (7.5 cm) in the same condition. Results: Ionization chamber: There were within 0.3% of error with gating respiration and approximately 2% of error without gating in the same condition. 2D-Array: Gantry $90^{\circ}$, field size $10{\times}10\;cm$, using DMLC. There were within 3% of error with gating respiration and approximately 16% of error without gating. Conclusion: The phantom for respiration gated radiotherapy makes plans considering patient's movement, quantitative analysis of exposure dose and proper assessment therapy for IMRT patients using RPM possible.

  • PDF

A STUDY ON IN VIVO AND IN VITRO AMALGAM CORROSION (아말감의 구강내 부식 및 인공 부식에 관한 연구)

  • Lim, Byong-Mok;Kwon, Hyuk-Choon;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.1
    • /
    • pp.1-33
    • /
    • 1997
  • The objective of this study was to analyze the in vitro and in vivo corrosion products of low and high copper amalgams. The four different types of amalgam alloy used in this study were Fine cut, Caulk spherical, Dispersalloy, and Tytin. After each amalgam alloy and Hg were triturated according to the directions of the manufacturer by means of the mechanical amalgamator(Amalgam mixer. Shinhung Co. Korea), the triturated mass was inserted into a cylindrical metal mold which was 12mm in diameter and 10mm in height. The mass was condensed by 150Kg/cm compressive force. The specimen was removed from the mold and aged at room temperature for about seven days. The standard surface preparation was routinely carried out by emery paper polishing under running water. In vitro amalgam specimens were potentiostatically polarized ten times in a normal saline solution at $37^{\circ}C$(potentiostat : HA-301. Hukuto Denko Corp. Japan). Each specimen was subjected to anodic polarization scan within the potential range -1700mV to+400mV(SCE). After corrosion tests, anodic polarization curves and corrosion potentials were obtained. The amount of component elements dissolved from amalgams into solution was measured three times by ICP AES(Inductive Coupled Plasma Atomic Emission Spectrometry: Plasma 40. Perkim Elmer Co. U.S.A.). The four different types of amalgam were filled in occlusal and buccal class I cavities of four human 3rd molars. After about five years the restorations were carefully removed after tooth extraction to preserve the structural details including the deteriorated margins. The occlusal surface, amalgam-tooth interface and the fractured surface of in vivo amalgam corrosion products were analyzed. In vivo and in vitro amalgam specimens were examined and analyzed metallographically by SEM(Scanning Electron Microscope: JSM 840. Jeol Co. Japan) and EDAX(Energy Dispersive Micro X-ray Analyser: JSM 840. Jeol Co. Japan). 1. The following results are obtained from in vitro corrosion tests. 1) Corrosion potentials of all amalgams became more noble after ten times passing through the in vitro corrosion test compared to first time. 2) After times through the test, released Cu concentration in saline solution was almost equal but highest in Fine cut. Ag and Hg ion concentration was highest in Caulk spherical and Sn was highest in Dispersalloy. 3) Analyses of surface corrosion products in vitro reveal the following results. a)The corroded surface of Caulk spherical has Na-Sn-Cl containing clusters of $5{\mu}m$ needle-like crystals and oval shapes of Sn-Cl phase, polyhedral Sn oxide phase. b)In Fine cut, there appeared to be a large Sn containing phase, surrounded by many Cu-Sn phases of $1{\mu}m$ granular shapes. c)Dispersalloy was covered by a thick reticular layer which contained Zn-Cl phase. d)In Tytin, a very thin, corroded layer had formed with irregularly growing Sn-Cl phases that looked like a stack of plates. 2. The following results are obtained by an analysis of in vivo amalgam corrosion products. 1) Occlusal surfaces of all amalgams were covered by thick amorphous layers containing Ca-P elements which were abraded by occlusal force. 2) In tooth-amalgam interface, Ca-P containing products were examined in all amalgams but were most clearly seen in low copper amalgams. 3) Sn oxide appeared as a polyhedral shape in internal space in Caulk spherical and Fine cut. 4) Apical pyramidal shaped Sn oxide and curved plate-like Sn-Cl phases resulted in Dispersalloy. 5) In Tytin, Sn oxide and Sn hydroxide were not seen but polyhedral Ag-Hg phase crystal appeared in internal space which assumed a ${\beta}_l$ phase.

  • PDF

Evaluation of Cat Brain infarction Model Using MicroPET (마이크로 PET을 이용한 고양이 뇌 경색 모델의 평가)

  • Lee, Jong-Jin;Lee, Dong-Soo;Kim, Yun-Hui;Hwang, Do-Won;Kim, Jin-Su;Lim, Sang-Moo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.6
    • /
    • pp.528-531
    • /
    • 2004
  • Purpose: PET has some disadvantage in the imaging of small animal due to poor resolution. With the advent of microPET scanner, it is possible to image small animals. However, the image quality was not good enough as human image. Due to larger brain, cat brain imaging was superior to mouse or rat. In this study, we established the cat brain infarction model and evaluate it and its temporal charge using microPET scanner. Materials and Methods: Two adult male cats were used. Anesthesia was done with xylazine and ketamine HCl. A burr hole was made at 1cm right lateral to the bregma. Collagenase type IV 10 ${\mu}l$ was injected using 30 G needle for 5 minutes to establish the infarction model. $^{18}F$-FDG microPET (Concorde Microsystems Inc., Knoxville, TN) scans were performed 1, 11 and 32 days after the infarction. In addition, $^{18}F$-FDG PET scans were performed using human PET scanner (Gemini, Philips medical systems, CA, USA) 13 and 47 days after the infarction. Results: Two cat brain infarction models were established. The glucose metabolism of an infarction lesion improved with time. An infarction lesion was also distinguishable in the human PET scan. Conclusion: We successfully established the cat brain infarction model and evaluated the infarcted lesion and its temporal change using $^{18}F$-FDG microPET scanner.

A STUDY ON THE GALVANIC CORROSION OF TITANIUM USING THE IMMERSION AND ELECTROCHEMICAL METHOD (침적법과 전기화학법을 이용한 티타늄의 갈바닉 부식에 관한 연구)

  • Kay, Kee-Sung;Chung, Chae-Heon;Kang, Dong-Wan;Kim, Byeong-Ok;Hwang, Ho-Gil;Ko, Yeong-Mu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.3
    • /
    • pp.584-609
    • /
    • 1995
  • The purpose of this study was to evaluate the difference of the galvanic corrosion behaviour of the titanium in contact with gold alloy, silva-palladium alloy, and nickel-chromium alloy using the immersion and electrochemical method. And the effects of galvallit couples between titanium and the dental alloys were assessed for their usefulness as materials for superstructure. The immersion method was performed by measuring the amount of metal elementsreleased by Inductivey coupled plasma emission spectroscopy(ICPES) The specimen of fifteen titanium plates, the five gold alloy, five silver-palladium, five nickel-chromium plates, and twenty acrylic resin plates ware fabricated, and also the specimen of sixty titanium plugs, the thirty gold alloy, thirty silver-palladium, and nickelc-hromium plugs were made. Thereafter, each plug of gold alloy, silver-palladium, and nickel-chromium inserted into the the titanium and acrylic resin plate, and also titanium plug inserted into the acrylic resin plate. The combination specimens uf galvanic couples immersed in 70m1 artificial saliva solution, and also specimens of four type alloy(that is, titanium, gold, silver-palladium and nickel-chromium alloy) plugs were immersed solely in 70m1 artificial sativa solution. The amount of metal elements released was observed during 21 weeks in the interval of each seven week. The electrochemical method was performed using computer-controlled potentiosta(Autostat 251. Sycopel Sicentific Ltd., U.K). The wax patterns(diameter 11.0mm, thickness,in 1.5mm) of four dental casting alloys were casted by centrifugal method and embedded in self-curing acrylic resin to be about $1.0cm^2$ of exposed surface area. Embedded specimens were polished with silicone carbide paper to #2,000, and ultrasonically cleaned. The working electrode is the specimen of four dental casting alloys, the reference electrode is a saturated calmel electrode(SCE) and the ounter electrode is made of platinum plate. In the artificial saliva solution, the potential scanning was carried out starting from-700mV(SCE) TO +1,000mV(SCE) and the scan rate was 75mV/min. Each polarization curve of alloy was recorded automatically on a logrithmic graphic paper by XY recorder. From the polarization curves of each galvanic couple, corrosion potential and corrosion rates, that is, corrosion density were compared and order of corrosion tendency was determined. From the experiments, the following results were obtained : 1. In the case of immersing titanium, gold alloy, silver-palladium alloy, and nickel-chromium alloysolely in the artificial saliva solution(group 1, 2, 3, and 4), the total amount of metal elements released was that group 4 was greater about 2, 3 times than group 3, and about 7.8 times than group 2. In the case of group 1, the amount of titanium released was not found after 8 week(p<0.001). 2. In the case of galvanic couples of titanium in contact with alloy(group 5, 6), the total amount of metal elements released of group 5 and 6 was less than that of group 7, 8, 9, and 10(p<0.05). 3. In the case of galvanic couples of titanium in contact with silver-palladium alloy(group 7, 8), the total amount of metal elements released of group 7 was greater about twice than that of group 5, and that of group 8 was about 14 times than that of group 6(p<0.05). 4. In the case of galvanic couples of titanium in contact with nickel-chromium alloy(group 9, 10), the total amount of metal elements released of group 9 and 10 was greater about 1.8-3.2 times than that of group 7 and 8, and was greater about 4.3~25 times than that of group 5 and 6(p<0.05). 5. In the effect of galvanic corrosion according to the difference of the area ratio of cathode and anode, the total amount of metal elements released was that group 5 was greater about 4 times than group 6, group 8 was greater about twice than group 7, and group 10 was greater about 1.5 times than group 9(p<0.05). 6. In the effect of galvanic corrosion according to the elasped time during 21 week in the interval of each 7 week, the amount of metal elements released was decreased markedly in the case of galvanic couples of the titanium in contact with gold alloy and silver-palladium alloy but the total amount of nickel and beryllium released was not decreased markedly in the case of galvanic couples of the titanium in contact with nickel-chromium alloy(p<0.05). 7. In the case of galvanic couples of titanium in contact with gold alloy, galvanic current was lower than any other galvanic couple. 8. In the case of galvanic couples of titanium in contact with nickel-chromium alloy, galvanic current was highest among other galvanic couples.

  • PDF