• 제목/요약/키워드: Moving Magnet Actuator

검색결과 60건 처리시간 0.036초

스프링 유무에 따른 가동자석형 직선형 액추에이터의 동특성해석 및 실험 (Dynamic Analysis and Experiments of Moving Magnet Linear Actuator with/without Spring)

  • 장석명;최장영;유대준;조한욱;박지훈;이성호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.911-913
    • /
    • 2005
  • This paper deals with the dynamic analysis and experiments of moving-magnet lineal actuator with/without spring. On the basis of two dimensional(2-D) analytical solutions and experiments, control parameters are obtained. And then, dynamic simulation algorithm is established from the voltage and motion equation. Finally, for various values of frequency, dynamic simulation results for characteristics of voltage, current and displacement of moving-magnet linear actuator are presented and confirmed through the experiments. In particular, This paper makes the PWM voltage waveform using a DSP for bidirectional voltage drive

  • PDF

자기적 비선형을 고려한 Moving Magnet Linear Actuator의 설계 및 동특성 해석 (Design and Dynamic Characteristics analysis of Moving Magnet Linear Actuator Considering the Magnetic Nonlinear phenomena)

  • 황규환;김철한;전계록;조윤현
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 추계학술대회 논문집
    • /
    • pp.259-262
    • /
    • 2003
  • This paper is proposed a new linear actuator with the permanent magnet on the mover. This linear actuator is designed to produce the vibration of a osillator. In order to evaluate its dynamic performance, the equivalent coupling parameter between mechanical and electromagnetic equations of the linear actustor, which is considered the magnetic nonlinear phenomena, is analyzed by the finite element method and estimated the thrust, displacement and acceleration with the simualation values and the experimenta ones.

  • PDF

자기력을 이용한 충격형 액추에이터의 설계 및 성능 평가 (Design and Performance Evaluation of Impact Type Actuator Using Magnetic Force)

  • 민현진;임형준;김병규;김수현
    • 대한기계학회논문집A
    • /
    • 제26권7호
    • /
    • pp.1438-1445
    • /
    • 2002
  • For robotic endoscope, some researchers suggest pneumatic actuators based on inchworm motion. But, the existing endoscopes have not been replaced completely because human intestine is very sensitive and susceptible to damage. We design and test a new locomotion of robotic endoscope that allows safe maneuverability in the human intestine. The actuating mechanism is composed of two solenoids at each side and a single permanent magnet. When the current direction is reversed, repulsive force and attractive at the opposition side propels permanent magnet. Impact force against robotic endoscope transfers momentum from moving magnet to endoscope capsule. The direction and moving speed of the actuator can be controlled by adjustment of impact force. Modeling and simulation experiments are carried out to predict the performance of the actuator. Simulations show that force profile of permanent magnet is the dominant factor for the characteristic of the actuator. The results of simulations are verified by comparing with the experimental results.

영구자석 다극 배치에 의한 가동 코일형 리니어 진도 엑츄에이터의 특성 (Characteristic of Moving Coil type Linear Oscillatory Actuator by Multi-Pole Permancent Magnet Arrangement)

  • 김덕현;강규홍;홍정표;김규탁
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제50권6호
    • /
    • pp.273-281
    • /
    • 2001
  • In order to overcome the demerit and to improve the operation characteristics of Moving Coil type Linear Oscillatory Actuator(MC-LOA) with single-pole permanent magnet, this paper presents two models having the balanced magnetic circuit by multi-pole permanent magnet. They are short coil type with two-pole single-sided and two-ple double-sided permanent magnet. The characteristics between single-pole and multi-pole permanent magnet type MC-LOA are compared. As a result, multi-pole type MC-LOA has more merits than single-pole type about operation characteristics improvement and machine volume. The characteristics analysis is performed by their dynamic analysis composed of kinetic and electric equations and Finite Element Method(FEM). The propriety of multi-pole type MC-LOA model is verified with analysis results.

  • PDF

가동 영구자석형 리니어 진동 액츄에이터를 이용한 진공 펌프의 설계 및 특성해석 (Design and Characteristic Analysis of Vaccum Pump Using Moving Magnet type Linear Oscillatory Actuator)

  • 조성호;김덕현;김규탁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.61-63
    • /
    • 2002
  • This paper deals with the design of vaccum pump using moving magnet type linear oscillaory actuator based on the design procedure and the characteristic analysis. To improve the starting characteristic, the optimum spring constant is detected and redesigned. The parameter was calculated by Finite Element Method(FEM). In order to dynamic characteristic analysis. Time difference method with voltage and kinetic equation is used.

  • PDF

전자기력을 이용한 2 자유도 스캐닝 미러 설계 (Design of 2-DoF Scanning Mirror using Electromagnetic force)

  • 신부현;김영진;오동호;이정우;최현호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.177-178
    • /
    • 2014
  • This work proposes a two-dimensional (2-D) laser scanning mirror actuator with a simple structure composed of one magnet and four coils. The mirror-actuating device generates 2-D scanning motions about two orthogonal axes by combining electromagnetic actuators of the conventional moving-magnet types. The magnet is attached to back side of the mirror placed inside of the moving frame. The four coils is placed on the base frame in a cross shape. We implement a finite element analysis to calculate magnetic flux in the electromagnetic system with the overall size of $20mm(W){\times}20mm(D){\times}13mm(H)$ for the mirror size of $8mm{\times}8mm$. The each moving-magnet type electromagnetic actuator has the motor constant 3.41 mNm/A and the restoring constant 1.75 mNm/rad and the resonance frequency of 58 Hz and the bandwidth of 80 Hz. The proposed compact and simple 2-D scanning mirror predicted advantages of large 2-D angular deflections, wide frequency bandwidth and low manufacturing cost.

  • PDF

트리즈를 활용한 하드디스크 드라이브 액추에이터 래치 장치의 신뢰성 문제 해결 (The Solution of Reliability Problem for the Actuator Latch Device of Hard Disk Drive Using TRIZ)

  • 정혜성
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제14권3호
    • /
    • pp.147-151
    • /
    • 2014
  • An actuator latch device of a hard disk drive is installed for locking an actuator to hold a magnetic head parked in a parking zone. Applying an external force to the drive, the head can move away from the parking zone and destroy data on the disk. A magnet latching mechanism is used to prevent the actuator from moving when the computer is not in use. A permanent magnet holds the actuator when the head is in the parking zone. When the computer is turned on, the actuator has to overcome the latch magnet in order to move. A stronger latch magnet will hold the actuator adequately, but the actuator will not be released when unlocking is required. A breakthrough solution is needed to improve the reliability of the drive without any deterioration of its performance. In order to obtain the idea for resolving this technical contradiction, we analyse patents for actuator latch device of a hard disk drive. A practical way for solving contradictions in product development using TRIZ is proposed in this paper.

Bi-directional Actuator using a permanent magnet and solenoid

  • Kim, K.H.;Kim, D.M.;Lee, S.Q.;D.G. Gweon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.98.1-98
    • /
    • 2001
  • An actuator using a permanent magnet and solenoid is proposed and designed in this paper. Its design concept is composed of a driving force generation, a guide mechanism, and a symmetric structure. At first, Driving Force generation uses a concept that is a change efflux by using a permanent magnet and solenoid. A permanent flux is generated by a permanent magnet. Changeable flux is created by a variable current flowing through coil such the solenoid. The direction of this flux is changed due to current flowing through coils. The combination of permanent and changeable fluxes make various flux densities between yokes of moving part and fixed yokes. And then, the flux densities create forces(F), which are used to drive this actuator, in lower and upper gap. In this actuator ...

  • PDF

A new mount with moving-magnet type electromagnetic actuator for naval shipboard equipment

  • Shin, Yun-Ho;Moon, Seok-Jun;Kwon, Jeong-Il;Jung, Woo-Jin;Jeon, Jae-Jin
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제7권1호
    • /
    • pp.41-55
    • /
    • 2015
  • This study is proposed a new hybrid mount having a moving-magnet type electromagnetic actuator to reduce the vibration transmitted from naval shipboard equipment to the structure of the ship's hull. Optimal design specifications are determined through experimental analysis. The detailed design of the hybrid mount is determined through several design steps with electromagnetic numerical analysis using Maxwell Software(S/W). The hybrid mount that combines a rubber mount and an electromagnetic actuator has a fail-safe function for shock resistance. The mount is fabricated and tested using a universal testing machine to evaluate the design specifications. Finally, numerical simulation of the hybrid mount is performed to confirm control performance and applicability.

입력전류에 따른 Magnetic Actuator의 동작특성 해석 (Analysis for Dynamic Characteristics of Magnetic Actuator According to Input Current)

  • 오연호;송기동;김귀식;김진기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.813-815
    • /
    • 2003
  • In this study, two magnetic actuator models are chosen to interpret dynamic characteristics. First model has no permanent magnet, on the contrary second has magnet that hold plunger to keep steady state. Both models are dynamically analyzed according to input current, and also compared with spending time and magnetic force at that moving is finished.

  • PDF