• Title/Summary/Keyword: Movements of the center of pressure

Search Result 52, Processing Time 0.031 seconds

The New X-ray Induced Electron Emission Spectrometer

  • Yu.N.Yuryev;Park, Hyun-Min;Lee, Hwack-Ju;Kim, Ju-Hwnag;Cho, Yang-Ku;K.Yu.Pogrebitsky
    • Proceedings of the Korea Crystallographic Association Conference
    • /
    • 2002.11a
    • /
    • pp.5-6
    • /
    • 2002
  • The new spectrometer for X-ray Induced Electron Emission Spectroscopy (XIEES) .has been recently developed in KRISS in collaboration with PTI (Russia). The spectrometer allows to perform research using the XAFS, SXAFS, XANES techniques (D.C.Koningsberger and R.Prins, 1988) as well as the number of techniques from XIEES field(L.A.Bakaleinikov et all, 1992). The experiments may be carried out with registration of transmitted through the sample x-rays (to investigate bulk samples) or/and total electron yield (TEY) from the sample surface that gives the high (down to several atomic mono-layers in soft x-ray region) near surface sensitivity. The combination of these methods together give the possibility to obtain a quantitative information on elemental composition, chemical state, atomic structure for powder samples and solids, including non-crystalline materials (the long range order is not required). The optical design of spectrometer is made according to Johannesson true focusing schematics and presented on the Fig.1. Five stepping motors are used to maintain the focusing condition during the photon energy scan (crystal angle, crystal position along rail, sample goniometer rail angle, sample goniometer position along rail and sample goniometer angle relatively of rail). All movements can be done independently and simultaneously that speeds up the setting of photon energy and allows the using of crystals with different Rowland radil. At present six curved crystals with different d-values and one flat synthetic multilayer are installed on revolver-type monochromator. This arrangement allows the wide range of x-rays from 100 eV up to 25 keV to be obtained. Another 4 stepping motors set exit slit width, sample angle, channeltron position and x-ray detector position. The differential pumping allows to unite vacuum chambers of spectrometer and x-ray generator avoiding the absorption of soft x-rays on Be foil of a window and in atmosphere. Another feature of vacuum system is separation of walls of vacuum chamber (which are deformed by the atmospheric pressure) from optical elements of spectrometer. This warrantees that the optical elements are precisely positioned. The detecting system of the spectrometer consists of two proportional counters, one scintillating detector and one channeltron detector. First proportional counter can be used as I/sub 0/-detector in transmission mode or by measuring the fluorescence from exit slit edge. The last installation can be used to measure the reference data (that is necessary in XANES measurements), in this case the reference sample is installed on slit knife edge. The second proportional counter measures the intensity of x-rays transmitted through the sample. The scintillating detector is used in the same way but on the air for the hard x-rays and for alignment purposes. Total electron yield from the sample is measured by channeltron. The spectrometer is fully controlled by special software that gives the high flexibility and reliability in carrying out of the experiments. Fig.2 and fig.3 present the typical XAFS spectra measured with spectrometer.

  • PDF

Comparison and evaluation of treatment plans using Abdominal compression and Continuous Positive Air Pressure for lung cancer SABR (폐암의 SABR(Stereotactic Ablative Radiotherapy)시 복부압박(Abdominal compression)과 CPAP(Continuous Positive Air Pressure)를 이용한 치료계획의 비교 및 평가)

  • Kim, Dae Ho;Son, Sang Jun;Mun, Jun Ki;Park, Jang Pil;Lee, Je Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.35-46
    • /
    • 2021
  • Purpose : By comparing and analyzing treatment plans using abdominal compression and The Continuous Positive Air Pressure(CPAP) during SABR of lung cancer, we try to contribute to the improvement of radiotherapy effect. Materials & Methods : In two of the lung SABR patients(A, B patient), we developed a SABR plan using abdominal compression device(the Body Pro-Lok, BPL) and CPAP and analyze the treatment plan through homogeneity, conformity and the parameters proposed in RTOG 0813. Furthermore, for each phase, the X, Y, and Z axis movements centered on PTV are analyzed in all 4D CTs and compared by obtaining the volume and average dose of PTV and OAR. Four cone beam computed tomography(CBCT) were used to measure the directions from the center of the PTV to the intrathoracic contacts in three directions out of 0°, 90°, 180° and 270°, and compare the differences from the average distance values in each direction. Result : Both treatment plans obtained using BPL and CPAP followed recommendations from RTOG, and there was no significant difference in homogeneity and conformity. The X-axis, Y-axis, and Z-axis movements centered on PTV in patient A were 0.49 cm, 0.37 cm, 1.66 cm with BPL and 0.16 cm, 0.12 cm, and 0.19 cm with CPAP, in patient B were 0.22 cm, 0.18 cm, 1.03 cm with BPL and 0.14 cm, 0.11 cm, and 0.4 cm with CPAP. In A patient, when using CPAP compared to BPL, ITV decreased by 46.27% and left lung volume increased by 41.94%, and average dose decreased by 52.81% in the heart. In B patient, volume increased by 106.89% in the left lung and 87.32% in the right lung, with an average dose decreased by 44.30% in the stomach. The maximum difference of A patient between the straight distance value and the mean distance value in each direction was 0.05 cm in the a-direction, 0.05 cm in the b-direction, and 0.41 cm in the c-direction. In B patient, there was a difference of 0.19 cm in the d-direction, 0.49 cm in the e-direction, and 0.06 cm in the f-direction. Conclusion : We confirm that increased lung volume with CPAP can reduce doses of OAR near the target more effectively than with BPL, and also contribute more effectively to restriction of tumor movement with respiration. It is considered that radiation therapy effects can be improved through the application of various sites of CPAP and the combination with CPAP and other treatment machines.

Effects of Preferred Arch Height and Hardness of the Insole on Static Arch Height and Ankle Stability (인솔의 아치높이 및 경도 선호도가 정적 아치 높이 및 발목 안정성에 미치는 영향)

  • Sihyun Ryu;Young-Seong Lee;Soo-Ji Han;Sang-Kyoon Park
    • Korean Journal of Applied Biomechanics
    • /
    • v.33 no.1
    • /
    • pp.25-33
    • /
    • 2023
  • Objective: The purpose of this study was to investigate the differences in static arch height and ankle stability according to the preference for insole height and hardness in the arch area. Method: The study participants were 20 adult males (age: 22.7 ± 1.8 yrs., height: 175.3 ± 4.3 cm, body weight: 72.5 ± 7.7 kg). First, the arch heights of all subjects were measured in static postures (sitting and standing). The inversion and eversion movements of the ankle joint were analyzed during walking (1.3 m/s & 1.7 m/s) and running (2.7 m/s & 3.3 m/s). The variables (static arch height, and inversion and eversion angle of ankle joint) were compared by classifying groups according to the preference for the height and hardness of the arch of the insole. First, it was divided into a high arch insole preference group (HAG, n=8) and a low arch insole preference group (LAG, n=12) according to the preference for the arch height of the insole. Second, it was divided into a high hardness insole preference group (HHG, n=7), medium hardness insole preference group (MHG, n=7), and low hardness insole preference group (LHG, n=6), according to the preference for the arch hardness of the insole. Results: First, the range of motion (ROM) of inversion-eversion at the ankle joint during walking was statistically smaller in HAG than in LAG (p<.05). Second, the arch height change of HHG was statistically greater than that of MHG and LHG (p<.05). Conclusion: In the case of flexible flat feet with a large change in arch height, providing a high hardness arch insole that can disperse foot pressure can improve comfort. It was found that people with high medial and lateral sway of the ankle joint preferred a low arch insole, but it is necessary to differentiate and compare the insole heights of the arch part in detail. In addition, in the case of fast motion such as running, the preference for the arch height and hardness of the insole was not related to the static arch height and ankle stability.

The Effect of Rehabilitation Training Programs on the Kinetic and Kinematic Parameters During Sit-To-Stand in Chronic Stroke Patients (만성편마비 환자의 재활 운동 유형이 일어서기 동작의 운동학 및 운동역학적 변인에 미치는 영향)

  • Yu, Yeon-Joo;Yoon, Te-Jin;Eun, Seon-Deok
    • Korean Journal of Applied Biomechanics
    • /
    • v.16 no.2
    • /
    • pp.121-134
    • /
    • 2006
  • The purpose of this study was to analyze the effect of different types of rehabilitation training program on the kinetic and kinematic parameters during sit-to-stand movement(STS) in chronic stroke patients. Two groups of hemiparetic patients, experimental and control, participated in the study. The experimental group participated in a 10-week training program (three sessions/wk, $1{\sim}1.5\;hr/session$) consisting of a warm-up, aerobic exercises, lower extremity strengthening. and a cool-down. The control group participated in an aerobic exercise. Three dimensional kinematic analysis and force platform; were used to analyze the duration of STS, lower extremity angle, and weight bearing ability. The experimental group which had more strength of lower extremity displayed decrease in duration of STS. However, the control group showed increases in duration during sit-to-stand movement. The control group flexed their trunk more than the group did Therefore, it took more time to extend their trunk during STS. The duration in sit-to-stand was affected by the strength of lower extremity and the angle of trunk movement. The angles of ankle and knee joint had an influenced on duration of STS. The post experimental group performed with their feet near the front leg of the chair during sit-to-stand, therefore the duration was decreased. The repetitive sit-to-stand movements as a resistance exercise was effective to hemiparetic patients in learning mechanism of sit-to-stand. The control group showed decreased differences in the vertical ground reaction forces between paretic and non-paretic limbs. Their training program included strengthening exercise that may help improving weight bearing ability. The control group showed increases in the center of pressure in the anteroposterior and mediolateral displacement. This means that the stability of movement was low in the control group. Their training program which combined aerobic and strengthening exercises that are more effective to improve the stability of movement.

Transient effects of jumping lunge on sand on balance ability in healthy adults: a preliminary study

  • Choi, Min-hyeok;Shin, Ho-jin;Hahm, Suk-Chan;Lee, Min-Goo;Cho, Hwi-young
    • Physical Therapy Rehabilitation Science
    • /
    • v.7 no.4
    • /
    • pp.172-178
    • /
    • 2018
  • Objective: The purpose of this study was to show the temporary effects of performing jumping lunges on a sand surface on static balance and dynamic balance. Design: Randomized controlled trial. Methods: Twenty healthy subjects volunteered in the study and was randomly assigned into either the sand group (n=10) or the control group (n=10). The subjects in the sand group performed jumping lunges on a sand surface and the subjects in the control group performed jumping lunges on a firm surface. The intervention was performed for 3 sets of 8 repetitions by both groups. To measure static balance, the force plate was employed to measure the center of pressure (CoP) area, and the CoP velocity during one-legged standing. Anterior, postero-medial, postero-lateral movements was assessed using the Star Excursion Balance Test (SEBT) to measure dynamic balance. Results: After the intervention, the sand group showed statistically significant improvements on all variables (CoP area, CoP velocity) in static balance (p<0.05). There were statistically significant changes in CoP area and CoP velocities between the two groups (p<0.05). In the sand group, there were significant improvements in the postero-medial and postero-lateral directions (p<0.05) except for anterior direction on dynamic balance. In the control group, there was a significant improvement in the postero-lateral and anterior directions (p<0.05). In comparison of the two groups, there was no statistically significant improvement in all variables. Conclusions: This study demonstrated that performing jumping lunges on a sand surface was effective in improving static and dynamic balance temporarily.

Dynamic Postural Control and Ankle Joint Laxity among Dancers and Non-dancers with Chronic Ankle Instability, and Healthy Dancers (만성 발목 불안정성을 가진 무용수와 비무용수, 건강한 무용수의 동적 자세 조절 및 발목 관절 이완성)

  • Eun Ji Hong;Jiho Kang;Hyung Gyu Jeon;Kyeongtak Song;Sae Yong Lee
    • Korean Journal of Applied Biomechanics
    • /
    • v.34 no.2
    • /
    • pp.93-103
    • /
    • 2024
  • Objective: The purpose of this study was to investigate whether dancers with chronic ankle instability (CAI) exhibit different characteristics in dynamic postural control ability and ankle joint laxity compared to dancers without CAI and non-dancers with CAI. Method: Twelve dancers with CAI, 14 dancers without CAI, and 12 non-dancers with CAI participated in the study. Dynamic balance was evaluated using the Star Excursion Balance Test (SEBT) and the single-leg hop balance. The laxity of the ankle joint was evaluated through the anterior drawer test and the talar tilt test. SEBT measured maximum reach distances in anterior, posteromedial, and posterolateral directions. Single-leg hop assessed center of pressure (COP) and time-to-boundary (TTB) outcomes. One-way ANOVA and Chi-square tests were performed to compare the outcome variables among the three groups. Results: Dancers with CAI demonstrated greater reach distance in the posterolateral direction compared to non-dancers with CAI during SEBT (p=.014). Secondly, dancers without CAI showed greater reach distance in the posterolateral (p<.001) and posteromedial (p=.001) directions during SEBT compared to non-dancers with CAI. Additionally, dancers without CAI exhibited better postural control with higher TTB AP mean of minima (p=.003) and TTB AP standard deviation of minima (p=.012) during single-leg hop compared to nondancers with CAI. Thirdly, dancers with CAI showed a lower positive rate during the anterior drawer test compared to non-dancers with CAI (p=.019). Conclusion: Dancers with CAI demonstrated better ankle function and reduced mechanical instability compared to non-dancers with CAI. Therefore, to elucidate the underlying mechanisms of lateral ankle sprain and CAI development exacerbation in dancers, additional factors that can affect ankle sprain, such as visual dependence during postural control and evaluation in dance movements, should be explored.

Development of Squat Posture Guidance System Using Kinect and Wii Balance Board

  • Oh, SeungJun;Kim, Dong Keun
    • Journal of information and communication convergence engineering
    • /
    • v.17 no.1
    • /
    • pp.74-83
    • /
    • 2019
  • This study designs a squat posture recognition system that can provide correct squat posture guidelines. This system comprises two modules: a Kinect camera for monitoring users' body movements and a Wii Balance Board(WBB) for measuring balanced postures with legs. Squat posture recognition involves two states: "Stand" and "Squat." Further, each state is divided into two postures: correct and incorrect. The incorrect postures of the Stand and Squat states were classified into three and two different types of postures, respectively. The factors that determine whether a posture is incorrect or correct include the difference between shoulder width and ankle width, knee angle, and coordinate of center of pressure(CoP). An expert and 10 participants participated in experiments, and the three factors used to determine the posture were measured using both Kinect and WBB. The acquired data from each device show that the expert's posture is more stable than that of the subjects. This data was classified using a support vector machine (SVM) and $na{\ddot{i}}ve$ Bayes classifier. The classification results showed that the accuracy achieved using the SVM and $na{\ddot{i}}ve$ Bayes classifier was 95.61% and 81.82%, respectively. Therefore, the developed system that used Kinect and WBB could classify correct and incorrect postures with high accuracy. Unlike in other studies, we obtained the spatial coordinates using Kinect and measured the length of the body. The balance of the body was measured using CoP coordinates obtained from the WBB, and meaningful results were obtained from the measured values. Finally, the developed system can help people analyze the squat posture easily and conveniently anywhere and can help present correct squat posture guidelines. By using this system, users can easily analyze the squat posture in daily life and suggest safe and accurate postures.

Enhanced Indoor Localization Scheme Based on Pedestrian Dead Reckoning and Kalman Filter Fusion with Smartphone Sensors (스마트폰 센서를 이용한 PDR과 칼만필터 기반 개선된 실내 위치 측위 기법)

  • Harun Jamil;Naeem Iqbal;Murad Ali Khan;Syed Shehryar Ali Naqvi;Do-Hyeun Kim
    • Journal of Internet of Things and Convergence
    • /
    • v.10 no.4
    • /
    • pp.101-108
    • /
    • 2024
  • Indoor localization is a critical component for numerous applications, ranging from navigation in large buildings to emergency response. This paper presents an enhanced Pedestrian Dead Reckoning (PDR) scheme using smartphone sensors, integrating neural network-aided motion recognition, Kalman filter-based error correction, and multi-sensor data fusion. The proposed system leverages data from the accelerometer, magnetometer, gyroscope, and barometer to accurately estimate a user's position and orientation. A neural network processes sensor data to classify motion modes and provide real-time adjustments to stride length and heading calculations. The Kalman filter further refines these estimates, reducing cumulative errors and drift. Experimental results, collected using a smartphone across various floors of University, demonstrate the scheme's ability to accurately track vertical movements and changes in heading direction. Comparative analyses show that the proposed CNN-LSTM model outperforms conventional CNN and Deep CNN models in angle prediction. Additionally, the integration of barometric pressure data enables precise floor level detection, enhancing the system's robustness in multi-story environments. Proposed comprehensive approach significantly improves the accuracy and reliability of indoor localization, making it viable for real-world applications.

A Study on the Reinforcement Effect Analysis of Aging Agricultural Reservoir using Surface Stabilizer (표층안정재를 사용한 노후 농업용 저수지의 보강효과 분석에 관한 연구)

  • Kim, Jae-Hong;Kim, You-Seong;Cho, Dae-sung
    • Journal of the Korean Geosynthetics Society
    • /
    • v.19 no.2
    • /
    • pp.13-21
    • /
    • 2020
  • In Korea, small reservoirs have been constructed for the supply of agricultural water, but most of them have been over 50 years from the year of construction. Aging agricultural reservoirs are being investigated for serious defects such as leaks and movements in slope, which are very vulnerable to safety. Accordingly, grouting methods are used to reinforce aging agricultural reservoirs in Korea. However, cement used as a grouting injection material consumes natural resources and generates a large amount of greenhouse gases during production. In addition, there is a problem that sufficient reinforcement is not made due to various factors such as the injection amount, the compounding ratio, the injection pressure, and etc. Therefore, due to these problems, the development of new materials and methods that can replace the grouting method and cement is required. In order to solve these problems, this study conducted an laboratory test on the surface stabilizer used to secure the stability of road and rail slopes. In addition, the program was analyzed and the reinforcing effect was examined when the surface stabilizer was used as reinforcement material for aging agricultural reservoir. As a result of the laboratory test, when the surface stabilizer is mixed, the increase of cohesion is possible up to 9% and there is no change in the friction angle. The results of the program analysis showed that the 1.0m reinforcement of slopes increased the factor of safety by 1.4 times, making it possible to reinforce the aging agricultural reservoir using surface stabilizers. And as a reinforcement method, it was analyzed that it is most appropriate to reinforce the slope and the bottom of slope simultaneously.

Effect of a Maepsi Exercise Program on the Ground Reaction Force Variables of middle-aged women during Gait (8주간의 맵시 운동 프로그램이 중년여성들의 보행 동작 시 지면반력 요인들에 미치는 영향)

  • Park, Hui-Jun;Kwon, Moon-Seok
    • Journal of the Korean Applied Science and Technology
    • /
    • v.38 no.3
    • /
    • pp.762-770
    • /
    • 2021
  • The purpose of this study was to analyze the effect on the vertical ground reaction force, the elapsed time, and the center of pressure factors during gait by maepsi exercise program, which is a whole body exercise, to middle-aged women for 8 weeks. A total of 25 subjects participated in this study, 13 in the exercise group(age, 41±4.4 years; heigh, 162.5±5.8cm; weight, 57.8±6.7kg; body mass, 21.9±2.4kg/m2) and 12 in the control group(age, 41.1±5.6 years; height, 160.9±5.5 cm; weight, 576.2±8.1 kg; body mass, 21.7±2.9 kg/m2). In the exercise group, the maepsi exercise program consisting of 7 areas, 23 types and 77 movements, was conducted 3 times a week for 8 weeks. Two-way repeated measures ANOVA was performed to verify the ground reaction force factors during gait, and the post-test was analyzed with bonferroni adjustment(a=.05). In the exercise group, compared to the control group, the exercise group showed higher values than the control group in the elapsed time to FMWA and FPO, vertical ground reaction force at FMWA and FPO, and RMS factors of COP in the AP direction. Therefore, it was found that the 8-week maepsi exercise program improved the acceleration and deceleration exercise functions of middle-aged women who performed gait.