• Title/Summary/Keyword: Movement axis

Search Result 419, Processing Time 0.026 seconds

Role of vitamin D for orthodontic tooth movement, external apical root resorption, and bone biomarker expression and remodeling: A systematic review

  • Martina Ferrillo;Dario Calafiore;Lorenzo Lippi;Francesco Agostini;Mario Migliario;Marco Invernizzi;Amerigo Giudice;Alessandro de Sire
    • The korean journal of orthodontics
    • /
    • v.54 no.1
    • /
    • pp.26-47
    • /
    • 2024
  • Objective: This systematic review aimed to evaluate the correlation between vitamin D levels and the rate of tooth movement, external apical root resorption, bone biomarker expression, and bone remodeling. Methods: Three databases (PubMed, Scopus, and Web of Science) were systematically searched from inception until 14th March 2023 to identify studies investigating the correlation between orthodontic tooth movement and vitamin D in animals and humans. The quality assessment was made in accordance with the Joanna Briggs Institute Critical Appraisal Checklist. Results: Overall, 519 records were identified, and 19 were selected for the qualitative synthesis. Eleven studies investigated the effect of local administration (injections in the periodontal ligament, to the gingiva distal to the teeth, or submucosae palatal area) and systemic administration (oral supplementation) of vitamin D on tooth movement, external apical root movement, pro-inflammatory cytokines, and bone remodeling factors. The remaining eight studies investigated the correlation between serum vitamin D levels and salivary vitamin D levels on bone turnover markers and tooth movement. Conclusions: The findings of this systematic review support that vitamin D3 local injections might increase the rate of tooth movement via the receptor activator of the nuclear factor-kB/osteoprotegerin axis. However, the non-uniform study designs and the different protocols and outcome methods make it challenging to draw reliable conclusions.

Comparative analysis of high-clear motion of female middle school student using COM and COP parameter (질량중심 및 압력중심을 이용한 여자 중학생의 하이클리어 동작 비교 분석)

  • Han, KiHoon;Park, JoonSung;Kwon, WooMoon;Kim, JaeWoong
    • Journal of the Korean Applied Science and Technology
    • /
    • v.37 no.4
    • /
    • pp.786-793
    • /
    • 2020
  • The purpose of this study is to analysis the horizontal distance of COM and COP and the movement patterns of COM and COP during the badminton high-clear of woman middle school student. The select variables used in the statistical analyses(independent sample T-test) were the horizontal distance of COM and COP at (E4), and the maximum COM displacement of the back-, forward-, whole-swing phases between expert and novice groups. Based on the results in this study, it was concluded that: First, expert group showed the shorter horizontal distance between COM and COP in anteroposterior axis (X-axis) at Event 4 compared to the novice group. Second, expert group dominantly used COM vertical movement while novice group actively used COM horizontal movement during the badminton high-clear stroke.

Measurement of Variation in Water Equivalent Path Length by Respiratory Organ Movement

  • Minohara, Shinichi;Kanai, Tatsuaki;Endo, Masahiro;Kato, Hirotoshi;Miyamoto, Tadaaki;Tsujii, Hirohiko
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.90-93
    • /
    • 2002
  • In particle radiotherapy, a shape of the beam to conform the irradiation field is statically defined by the compensator, collimator and potal devices at the outside of the patient body. However the target such as lung or liver cancer moves along with respiration. This increases the irradiated volume of normal tissue. Prior discussions about organ motions along with respiration have been mainly focused on inferior-superior movement that was usually perpendicular to beam axis. On the other hand, the change of the target depth along the beam axis is very important especially in particle radiotherapy, because the range end of beam (Bragg peak) is so sharp as to be matched to distal edge of the target. In treatment planning, the range of the particle beam inside the body is calculated using a calibration curve relating CT number and water equivalent path length (WEL) to correct the inhomogeneities of tissues. The variation in CT number along the beam path would cause the uncertainties of range calculation at treatment planning for particle radiotherapy. To estimate the uncertainties of the range calculation associated with patient breathing, we proposed the method using sequential CT images with respiration waveform, and analyzed organ motions and WELs at patients that had lung or liver cancer. The variation of the depth along the beam path was presented in WEL rather than geometrical length. In analyzed cases, WELs around the diaphragm were remarkably changed depending on the respiration, and the magnitude of these WEL variations was almost comparable to inferior-superior movement of diaphragm. The variation of WEL around the lung was influenced by heartbeat.

  • PDF

Enhancement of 4 Bar Parallelogram Linkage for a Medical Bed (의료용 침대를 위한 평행 4절 링크의 개선)

  • Lee, Youngdae;Kim, Changyoung;Choi, Moonsoo
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.1
    • /
    • pp.515-520
    • /
    • 2020
  • The design and actual implementation of the four-bar parallel link was studied in the paper. The parallel four-section link is widely used as a basic kinematic mechanism for transmitting the rotation of one axis to the rotational motion of the other axis. However, the parallel 4 link has a problem that phase reversal occurs at the turning point during the movement. In order to prevent the link reversal, it is known that a double parallelogram-type link is formed by attaching an additional phase reversal suppression link with an offset. However, as a result of the actual fabrication experiment, the movement is not smooth at the transition point. In order to solve this problem, in this study, a link for smooth movement is added in addition to a link that provides an offset to prevent phase reversal, so that the phase reversal does not occur at a specific point when the driven shaft rotates along the drive shaft. The test result confirms the validity of our suggestion.

Effects of Tilting and Bending on Embroidered Dipole Array Antenna (자수된 다이폴 어레이 안테나에 미치는 기울임과 굽힘의 영향)

  • Ki, Hyeon-Cheol
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.22 no.2
    • /
    • pp.21-26
    • /
    • 2022
  • In this paper, we investigated the effect of tilting and bending of an 2.45GHz ISM band embroidered dipole array antenna due to the human body movement. The antenna characteristics showed larger variations in tilting on the X-axis than the Y-axis. The antenna gain varied by 0.25[dB] when the antenna tilted by 3.5°. As tilting angle increased the operating frequency(fo) showed decreasing tendency and the return loss(S11) showed increasing tendency. The antenna characteristics also showed more variation in bending on the X-axis than the Y-axis. As bending the antenna the antenna characteristics affected much more in bending on the X-axis than the Y-axis. The antenna gain varied by 3.73[dB] as the curvature(1/R_rad) increased by 0.04[mm-1]. As it bended more the operating frequency(fo) showed decreasing and then increasing tendency and the return loss(S11) showed increasing tendency.

Mathematical Expression of Eye Movement Using Rotation Matrix (Rotation Matrix를 이용한 안구운동의 수학적 표현)

  • Kim, YongGeun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.4 no.2
    • /
    • pp.51-55
    • /
    • 1999
  • The eye movement of the eyeball's center of a rotation can represent with the rotation matrix $R_x$, $R_y$, $R_z$ due to a coordinate axis rotation transformation of Cartesian coordinate, and describes of an abduction, an adduction, an elevation, a depression, an intorsion, an extorsion in principle rotation six forms of the eye. The eye movement from primary eye position to tertiary eye position could be composed with the rotation matrix combination, and by the primary rotation of six and the secondary rotation of eight, could be represented with the extrocular muscle of six. The position of the cornea vertex point or pupil point due to the eye movement can describe to transform the rotation matrix of the cartesian coordinate to spherical coordinate$(r,{\theta},{\phi})$.

  • PDF

MTF Evaluation according to change in posture and channel during CT examination for wrist Joint : X-axis and Z-axis changes around Isocenter (손목관절 CT 검사 시 자세 변화와 채널 변경에 따른 MTF 평가 : Isocenter를 중심으로 X-축, Z-축 변화)

  • Seo, Min Jae;Lim, Jong Chon;Jung, Dabin;Han, Dong Kyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.6
    • /
    • pp.811-817
    • /
    • 2020
  • This study aims to evaluate the Modulation Transfer Function (MTF) according to the change in the number of channels of the CT examination device by changing the posture of the patient to the X-axis and Y-axis in the wrist joint CT examination. Using a CT device and a wrist phantom, the test was performed by moving 0 (matched), 5, 10, and 15 cm in the X-axis around the isocenter, and the Z-axis was rotated by -20° and -40°. For the test, 16, -40 and 64 channels were used to check whether there was a difference for each number of channels. The examined images were compared by measuring the MTF values of the ulna and left and right sides of the radius. In the experiment where the isocenter was moved along the X-axis, the MTF value decreased with an increase in the moving distance, and the MTF value was found to be unaffected by the number of channels. In the experiment in which the wrist joint was rotated by -20° and -40° on the Z-axis, the degree of deviation and MTF were found to be irrelevant. It was not related to the number of channels either. In conclusion, the movement of the wrist along the X-axis should be restrained as much as possible for a wrist joint CT scan, whereas deviation around the Z-axis depending on the environment for the patient would not affect the MTF of the image.

3-D Kinematic Analysis According to Open Stance Patterns During Forehand Stroke in Tennis (테니스 포핸드 스트로크 동안 오픈스탠스 조건에 따른 3차원 운동학적 분석)

  • Choi, Ji-Young;Kim, Ro-Bin
    • Korean Journal of Applied Biomechanics
    • /
    • v.15 no.3
    • /
    • pp.161-173
    • /
    • 2005
  • Recently among several tennis techniques forehand stroke has been greatly changed in the aspect of spin, grip and stance. The most fundamental factor among the three factors is the stance which consists of open, square and closed stance. The purpose of this study was to investigate the relations between the segments of the body, the three dimensional anatomical angle according to open stance patterns during forehand stroke in tennis. For the movement analysis three dimensional cinematographical method(APAS) was used and for the calculation of the kinematic variables a self developed program was used with the LabVlEW 6.1 graphical programming(Johnson, 1999) program. By using Eular's equations the three dimensional anatomical Cardan angles of the joint and racket head angle were defined 1. In three dimensional maximum linear velocity of racket head the X axis showed $11.41{\pm}5.27m/s$ at impact, not the Y axis(horizontal direction) and the z axis(vertical direction) maximum linear velocity of racket head did not show at impact but after impact this will resulted influence upon hitting ball It could be suggest that Y axis velocity of racket head influence on ball direction and z axis velocity influence on ball spin after impact. the stance distance between right foot and left foot was mean $74.2{\pm}11.2m$. 2. The three dimensional anatomical angular displacement of shoulder joint showed most important role in forehand stroke. and is followed by wrist joints, in addition the movement of elbow joints showed least to the stroke. The three dimensional anatomical angular displacement of racket increased flexion/abduction angle until the impact. after impact, The angular displacement of racket changed motion direction as extension/adduction. 3. The three dimensional anatomical angular displacement of trunk in flexion-extension showed extension all around the forehand stroke. The angular displacement of trunk in adduction-abduction showed abduction at the backswing top and adduction around impact. while there is no significant internal-external rotation 4. The three dimensional anatomical angular displacement of hip joint and knee joint increased extension angle after minimum of knee joint angle in the forehand stroke, The three dimensional anatomical angular displacement of ankle joint showed plantar flexion, internal rotation and eversion in forehand stroke. it could be suggest that the plantar pressure of open stance during forehand stroke would be distributed more largely to the fore foot. and lateral side.

Development of Educational 6-axis Articulated Manipulator Using 4-bar Linkage (4-bar Linkage를 이용한 교육용 6축 수직 다관절 로봇 개발)

  • 김대영;김성현;박정미;정원지
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.524-527
    • /
    • 2002
  • This paper is on the development of an educational 6-axis articulated manipulator using 4-bar linkage system. Especially, the 2$^{nd}$ and the 3$^{rd}$ axes need large torque to control the movement of an end-effect. However, small motors (RC-servo, DC-gear, stepping meters) are used for the 4-bar linkage. In addition the manipulator can be operated by a switch and also motion can be realized automatically, based on C-language coded users programs..

  • PDF

Investigation of Influences of Synchronizing Errors on the Tapping Characteristics and Thread Quality in the Ultra-High-Speed Tapping (초고속 태핑에서 동기오차가 태평특성과 나사품질에 미치는 영향 분석)

  • 이돈진;김선호;안중환
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.9
    • /
    • pp.40-46
    • /
    • 2003
  • Synchronizing errors between the spindle motor and the z-axis motor directly influences the cutting characteristics and the thread quality in tapping, because the tapping process is accomplished by synchronizing the movement of the z-axis with the revolutionary spindle motion. Generally synchronizing errors are decided by tile parameters of the servo system and commanded velocity. The excessive synchronizing errors which are induced by the parameter mismatch and high cutting velocity can cause tap breakage due to the abrupt increase of cutting torque or damage the thread accuracy by overcutting the already cut threads. In this paper, the influences of the synchronizing errors on the tapping characteristics in the ultra high-speed tapping will be described and a minimum level of synchronizing errors necessary to maintain the quality of the cut thread will be presented.