• Title/Summary/Keyword: Movement Monitoring

Search Result 537, Processing Time 0.03 seconds

Study of Modeling for Stock Food Material with Location Movement by the Communication Signal System

  • Kim, Jeong-Lae;Kim, Jung-Yun;Rha, Young-Ah
    • International Journal of Advanced Culture Technology
    • /
    • v.9 no.4
    • /
    • pp.409-416
    • /
    • 2021
  • We are invented the movement composition technique that is to check the food adjacent-package status of the wireless-management movement monitoring level (WMMML) on the movement monitoring communication system. The movement monitoring level condition by the movement monitoring communication system is formatted with the adjacent-package system. As to inspection a wireless RFID of the wireless RFID, we are found of the movement value with wireless RFID by the adjacent upper take form. The concept of movement monitoring level is formatted the reference of wireless-management level for composition signal by the movement package communication system. Further symbolizing a food composition of the WMMML of the medium-minimum in terms of the adjacent-package communication system, and the movement wireless RFID package that was the movement value of the far composition of the Mo-MMCS-FA-φMED-MIN with 5.80±1.20 units, that was the movement value of the convenient composition of the Mo-MMCS-CO-φMED-MIN with 4.06±(-0.04) units, that was the movement value of the flank composition of the Mo-MMCS-MO-φMED-MIN with 0.91±0.07 units, that was the movement value of the vicinage composition of the Mo-MMCS-VI-φMED-MIN with 0.18±(-0.03) units. The adjacent package will be to look into at the food ability of the adjacent-package communication system with wireless RFID by the movement monitoring level on the WMMML that is supply the wireless communication by the movement monitoring level system. We will be possible to make effort of a communication system by the management signal and to put to use of the delivery data of RFID level by the delivery system.

Monitoring about Crustal Deformation by Earthquake in the East of Japan (일본 동부지역 지진에 따른 지각변동 모니터링)

  • Park, Joon-Kyu;Kim, Min-Gyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.5
    • /
    • pp.2390-2395
    • /
    • 2012
  • Monitoring of crustal movement by earthquake is an important line of study in geophysics and geodesy. In this Study, before and after the earthquake data about nine IGS permanent stations were processed by Precise Positioning System to analysis the influence area about Japanese earthquake in March 11 at 2:46pm. As the result of crustal deformation monitoring, the quantitative earthquake displacement and change of crustal movement was presented. Crustal movement monitoring using continuous GPS data processing is necessary for crustal research and predicting earthquake because crustal movement assumed a new aspect before and after the earthquake in Japan.

Full-scale bridge expansion joint monitoring using a real-time wireless network

  • Pierredens Fils;Shinae Jang;Daisy Ren;Jiachen Wang;Song Han;Ramesh Malla
    • Structural Monitoring and Maintenance
    • /
    • v.9 no.4
    • /
    • pp.359-371
    • /
    • 2022
  • Bridges are critical to the civil engineering infrastructure network as they facilitate movement of people, the transportation of goods and services. Given the aging of bridge infrastructure, federal officials mandate visual inspections biennially to identify necessary repair actions which are time, cost, and labor-intensive. Additionally, the expansion joints of bridges are rarely monitored due to cost. However, expansion joints are critical as they absorb movement from thermal effects, loadings strains, impact, abutment settlement, and vehicle motion movement. Thus, the need to monitor bridge expansion joints efficiently, at a low cost, and wirelessly is desired. This paper addresses bridge joint monitoring needs to develop a cost-effective, real-time wireless system that can be validated in a full-scale bridge structure. To this end, a wireless expansion joint monitoring was developed using commercial-off-the-shelf (COTS) sensors. An in-service bridge was selected as a testbed to validate the performance of the developed system compared with traditional displacement sensor, LVDT, temperature and humidity sensors. The short-term monitoring campaign with the wireless sensor system with the internet protocol version 6 over the time slotted channel hopping mode of IEEE 802.15.4e (6TiSCH) network showed reliable results, providing high potential of the developed system for effective joint monitoring at a low cost.

MOVEMENT CONTROL OF HIGH-RISE BUILDINGS DURING CONSTRUCTION

  • Taehun Ha;Sungho Lee;Bohwan Oh
    • International conference on construction engineering and project management
    • /
    • 2011.02a
    • /
    • pp.46-51
    • /
    • 2011
  • High-rise buildings are widely being constructed in the Middle-East, South-East, and East Asia. These buildings are usually willing to stand for the landmark of the region and, therefore, exhibit some extraordinary features such as super-tall height, elevation set-backs, overhangs, or free-form exterior surface, all of which makes the construction difficult, complex, and even unsafe at some construction stages. In addition to the elaborately planned construction sequence, prediction and monitoring of building's movement during construction and after completion are required for precise and safe construction. This is often called the Building Movement Control during construction. This study describes Building Movement Control of the KLCC Tower, a 58-story office building currently being built right next to the famous PETRONAS Twin Towers. The main items of the Building Movement Control for the KLCC Tower are axial shortening and verticality. Preliminary prediction of these items are already carried out by the structural design team but more accurate prediction based on construction stage analysis and combined with time-dependent material testing, field monitoring, and site survey is done by the main contractor. As of September 2010, the Tower is under construction at level 30, where the plan abruptly changes from rectangle to triangle. Findings and troubleshooting until the current construction stage are explained in detail and implementations are suggested for future applications.

  • PDF

Influences of Myo-monitoring on Masticatory Muscles (Myo-Monitoring이 저항근에 미치는 영향)

  • Kwang-Woo Lee;Woo-Cheon Kee;Sung-Su Jung
    • Journal of Oral Medicine and Pain
    • /
    • v.14 no.1
    • /
    • pp.89-103
    • /
    • 1989
  • In order to evaluate the influences of Myo-monitoring on masticatory muscles, Myo-monitoring on 31 normal persons and 30 persons with one more temporomandibular dysfunction symptoms during 45 minutes or above. The author observed velocities of mandibular opening and closing movement, variabilities of mandibular rest position and EMG activities of temporal and masseter muscles. The obtained results were as follows : 1. There were no significant differences on velocities of mandibular opening and closing movement between before and after Myo-monitoring. 2. There were significant differences on vertical dimension and total dimension form mandibular rest position to centric occlusion between before and after Myo-monitoring but no significant differences on anteroposterior and lateral dimension. 3. Activities of temporal and masseter muscles were decreased in Myo-Monitoring. 4. There were disappeared significant differences on EMG activity values between normal and symptom groups after myo-monitoring.

  • PDF

Monitoring and Tracking Model of Logistics Based on ICT network

  • Cho, Sokpal;Chung, Heechang
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.489-492
    • /
    • 2016
  • Transportation in the logistics, many business organizations are engaged in monitoring and tracking the vehicles in order to improve logistics services, reduce expenses and secure security in cargo transportation. It is saving time and money by tracking and monitoring vehicles which transport cargo in supply chain of logistics. Therefore the main issue of delivery flow is to improve services, and ensure the safety in transportation system. This article suggests the tracking and monitoring model to keep safety transports on ICT network. It focuses on precise delivery control by monitoring and tracking vehicles to save time and costs. The status of product movement is analyzed for proper decision making. The vehicle embedded with RFID is automatically tracked in the movement process by tracking and monitoring model. The main role keeps safety tracking to reduce costs and to deliver products at proper time and location.

  • PDF

A Monitoring System for Sudden Infant Death Syndrome Prevention (유아 돌연사 증후군 방지를 위한 모니터링 시스템)

  • Jung, Kyung-Kwon;Hyun, Kyo-Hwan;Kim, Joo-Woong;Oh, Jung-Hoon;Joh, Hyung-Gook;Eom, Ki-Hwan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.05a
    • /
    • pp.481-484
    • /
    • 2008
  • Sudden infant death syndrome (SIDS) is the leading cause of unexplained death of an apparently healthy infant aged one month to one year. This paper presents a infant monitoring system which detects the movement of infants to prevent SIDS. The proposed system is composed of an movement sensing part and a motion detecting part. The movement sensing part uses a tri-axis accelerometer. The motion detecting part is based on the LVQ algorithm. The proposed monitoring system connects to an alarm for alerting a parent when an infant is in a predetermined position. We evaluated the performance of the monitoring system through experiments.

  • PDF

Sudden Infant Death Syndrome Prevention Monitoring System using the LVQ (LVQ를 이용한 영아돌연사 방지 모니터링 시스템)

  • Jung, Kyung-Kwon;Eom, Ki-Hwan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.9
    • /
    • pp.1675-1681
    • /
    • 2008
  • Sudden infant death syndrome (SIDS) is the leading cause of unexplained death of an apparently healthy infant aged one month to one year. This paper presents an infant monitoring system which detects the movement of infants to prevent SIDS. The proposed system is composed of a movement tenting part and a motion detecting part. The movement sensing part uses a tri-axis accelerometer. The motion detecting part is based on the LVQ algorithm. The proposed monitoring system connects to an alarm for alerting a parent when an infant is in a predetermined position. We evaluated the performance of the monitoring system through experiments.

A Study of Sensing Locations for ECG Monitoring Clothing based on the Skin Change rate (체표 변화에 기반한 심전도 모니터링 의류의 센싱 위치 연구)

  • Cho, Hakyung;Cho, Sang woo
    • Fashion & Textile Research Journal
    • /
    • v.17 no.5
    • /
    • pp.844-853
    • /
    • 2015
  • Recently, according to change of lifestyle and increase of concerning in health, needs of the smart clothing based on the vital sign monitoring have increased. Along with this trend, smart clothing for ECG monitoring has been studied various way as textile electrode, clothing design and so on. Smart clothing for ECG monitoring can become a comfortable system which enables continuous vital sign monitoring in daily use. But, smart clothing for ECG monitoring has a weakness on artifact during motion. One of the motion artifact caused by shifting of the electrode position was affected skin change by motion. The aim of this study was to suggest electrode locations for clothing of ECG monitoring to reduce of motion artifacts. Therefore, change of skin surface during the movement were measured and analyzed in order to find location to minimize motion artifacts in ECG monitoring clothing by 3D motion capture. For the experiment, the subjects consisted of 5 males and 5 females in their 20' with average physique. As a result, the optimal location for ECG monitoring was deducted under the bust line and scapula which have least motion artifact. These locations were abstracted to be least affected by movement in this research.

Monitoring Activity for Recognition of Illness in Experimentally Infected Weaned Piglets Using Received Signal Strength Indication ZigBee-based Wireless Acceleration Sensor

  • Ahmed, Sonia Tabasum;Mun, Hong-Seok;Islam, Md. Manirul;Yoe, Hyun;Yang, Chul-Ju
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.29 no.1
    • /
    • pp.149-156
    • /
    • 2016
  • In this experiment, we proposed and implemented a disease forecasting system using a received signal strength indication ZigBee-based wireless network with a 3-axis acceleration sensor to detect illness at an early stage by monitoring movement of experimentally infected weaned piglets. Twenty seven piglets were divided into control, Salmonella enteritidis (SE) infection, and Escherichia coli (EC) infection group, and their movements were monitored for five days using wireless sensor nodes on their backs. Data generated showed the 3-axis movement of piglets (X-axis: left and right direction, Y-axis: anteroposterior direction, and Z-axis: up and down direction) at five different time periods. Piglets in both infected groups had lower weight gain and feed intake, as well as higher feed conversion ratios than the control group (p<0.05). Infection with SE and EC resulted in reduced body temperature of the piglets at day 2, 4, and 5 (p<0.05). The early morning X-axis movement did not differ between groups; however, the Y-axis movement was higher in the EC group (day 1 and 2), and the Z-axis movement was higher in the EC (day 1) and SE group (day 4) during different experimental periods (p<0.05). The morning X and Y-axis movement did not differ between treatment groups. However, the Z-axis movement was higher in both infected groups at day 1 and lower at day 4 compared to the control (p<0.05). The midday X-axis movement was significantly lower in both infected groups (day 4 and 5) compared to the control (p<0.05), whereas the Y-axis movement did not differ. The Z-axis movement was highest in the SE group at day 1 and 2 and lower at day 4 and 5 (p<0.05). Evening X-axis movement was highest in the control group throughout the experimental period. During day 1 and 2, the Z-axis movement was higher in both of the infected groups; whereas it was lower in the SE group during day 3 and 4 (p<0.05). During day 1 and 2, the night X-axis movement was lower and the Z-axis movement was higher in the infected piglets (p<0.05). Overall, the movement of infected piglets was altered, and the acceleration sensor could be successfully employed for monitoring pig activity.