• Title/Summary/Keyword: Mouth, edentulous

Search Result 80, Processing Time 0.031 seconds

Location of maxillary intraosseous vascular anastomosis based on the tooth position and height of the residual alveolar bone: computed tomographic analysis

  • Yang, Seung-Min;Kye, Seung-Beom
    • Journal of Periodontal and Implant Science
    • /
    • v.44 no.2
    • /
    • pp.50-56
    • /
    • 2014
  • Purpose: The aims of this study were to measure the distance of the intraosseous vascular anastomosis in the anterolateral wall of the maxillary sinus from different reference points, and to correlate the location of the intraosseous vascular anastomosis with the tooth position and the residual bone height of the maxilla. Methods: Computed tomography (CT) images were taken from 283 patients undergoing dental implants placement in the posterior maxilla. Three horizontal lines were drawn at the ridge crest, maxillary sinus floor, and the position of the anastomosis. A vertical second line at the center of each tooth was drawn perpendicular to the horizontal lines. The distance from the ridge crest to the maxillary sinus floor and the distance from the maxillary sinus floor to the bony canal were measured from the intersections of the horizontal and vertical lines. The residual alveolar bone height was used to categorize three groups: group 1,<4 mm; group 2, between 4 and 8 mm; and group 3, >8 mm. Results: The residual bone height values of different tooth positions were significantly different (P=0.0002). The distance from the maxillary sinus floor to the intraosseous vascular anastomosis was significantly different between groups 1 and 3 (P=0.0039). At the molar sites, a moderate negative correlation was found between the residual bone height and the distance from the maxillary sinus floor to the intraosseous anastomosis. The distances of the alveolar ridge crest and the maxillary sinus from the intraosseous vascular anastomosis were not significantly different between sexes. Conclusions: Within the limitations of this study, sites with a higher residual bone height in the molar regions were at a relatively high risk of artery damage during window osteotomy preparation; therefore, we recommend taking more precautions when using a lateral approach for sinus elevation.

Full mouth rehabilitation with Implant-Guided Surgery and Fixed prosthesis (Implant-Guided Surgery를 이용한 고정성 임플란트 보철물의 전악 수복 증례)

  • Kim, Seong-Mo;Park, Jin-Hong;Ryu, Jae-Jun;Shin, Sang Wan;Lee, Jeong-Yol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.2
    • /
    • pp.126-133
    • /
    • 2018
  • The development of cone beam computerized tomography (CBCT) allows three-dimensional analysis of the patient's anatomy. The surgical guide is a combination of CBCT, computer-aided design/computer-aided manufacturing (CAD/CAM) and implant diagnostics software, which allows well planned prostheses design and ideal implant placement. Guided surgery minimizes possible anatomical damage and allows for more reproducible treatment planning. In this case, the operation time was shortened by using a surgical guide for multiple implants placement in a fully edentulous patient. Immediate loading were performed more easily using preliminary preparation of provisional prosthesis. The patient was satisfied with improved esthetics and chewing function.

Spreadability observation of the denture adhesive by the amount of the water (수분함량에 따른 의치접착제의 확장성 관찰)

  • Kim, Jong-Moon;Choi, Sung-Min
    • Journal of Technologic Dentistry
    • /
    • v.37 no.1
    • /
    • pp.17-21
    • /
    • 2015
  • Purpose: In this study, Spreadability of denture adhesive in accordance with the saturation level of saliva, respectively, by using the resin plate and the glass was measured thickness and Spreadability. Methods: Examine the spreadability of denture adhesive in accordance with the saturation level of saliva, respectively, by using the resin plate and the glass was measured thickness and Spreadability. Also, by measuring the adhesive strength according to the amount of saliva, and the edentulous patients using denture adhesive and dry mouth patients attempt to provide clinical information of the denture adhesive. Therefore, by using the relatively low shrinkage cold curing resin, after fabricating specimen of plate form, for 7 days, it was immersed in water. Results: For the control group only denture adhesive, an artificial saliva for the experimental group were injected in $0.1m{\ell}$, $0.2m{\ell}$ and $0.3m{\ell}$ of the denture adhesive on the surface, experimental results of the investigation of the 10 times the tensile bond strength of the specimens in each group was obtained the following results. Conclusion: As the time to pressure increase in the same amount of saliva was found that the amount coming out of the denture adhesive, as the amount of saliva in the same pressure increase coming out of many denture adhesives. And the greater the pressure came out a lot of denture adhesives. Spreadability in measuring saliva contact with $0.1m{\ell}$ and $2m{\ell}$ and $3m{\ell}$ group pressured the diameter of the circular was the denture adhesive is small when compared to the group without adding the pressure of 2kg and 3kg put the saliva. The size of the circle is the same amount of saliva denture adhesive spread more pressure showed a greater increase.

Full mouth rehabilitation of the patient with crossed occlusion using removable partial denture restoration: A case report (엇갈린 교합 환자에서의 가철성 보철을 이용한 전악구강회복 증례)

  • Choi, Yu-Ra;Kang, Jeong-Kyung;Kim, Na-Hong;Chang, Hee-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.1
    • /
    • pp.38-45
    • /
    • 2017
  • In removable partial denture with crossed occlusion, it is difficult to meet the satisfaction of patient due to variable movement of denture and unfavorable stability under loading. In a case with few unilaterally teeth remaining, additional treatments such as implantation or residual root are required to assure bilaterally stable support. However, due to the medical condition of the patient with hypertension, angina and old age etc., removable partial denture was planned as treatment in this case. Proper diagnosis, accurate analysis and full understanding of the adaptation for neuromuscular system are necessary to recover the vertical dimension of patient from a decreased vertical dimension due to crossed occlusion.

Prosthetic treatment with correcting edentulous maxillomandibular relation (무치악치조제의 개선을 통한 보철치료)

  • Rhee, Ye-Kyu;Huh, Yoon-Hyuck;Park, Chan-Jin;Cho, Lee-Ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.4
    • /
    • pp.339-349
    • /
    • 2014
  • If the maxillomandibular relationship is unstable or requires treatment for improved function and esthetics, the first treatment objective is to provide stable occlusal contacts. The patient has moderate mental retardation. Due to inadequate vertical overjet, horizontal arch malrelation and excessive tooth loss, full mouth rehabilitation was required. The purpose of treatment planning is to establish physiologic maxillomandibular relation. Using cephalometrics for occlusal analysis is an aid to make a decision. The amount of horizontal bone reduction was calculated with evaluating soft tissue profile. After provisional denture placement, healing of the surgical site and newly adapted arch relationship was evaluated. The patient satisfied with esthetics and showed stable holding contacts. Periodic examination is needed to exclude occlusal disharmony.

ACCURACY OF THE IMPRESSION TECHNIQUE USING THERMOFORMING POLYMETHYL METHACRYLATE TRAY

  • Miyashita, Yuko;Suzuki, Hiroki;Kishi, Masataka;Ko, Sok-Min
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.3
    • /
    • pp.389-400
    • /
    • 2007
  • Statement of problem. Use of the conventional dental impression procedure is problematic in patients who have difficulty opening their mouth, difficulty breathing through their nose or tendency to gag. Purpose. It is necessary to make individual trays more comfortable for patients during impression taking procedure. It was reported at the KAP Annual Meeting 2001 Seoul that an improved impression technique was suitable for this purpose. In this study, the accuracy of the improved dental impression method for implant was compared with the conventional dental impression method. Material and methods. An oral simulator was made from clear acrylic resin block which had similar form of edentulous ridge. For setting up the standard, five fixtures were installed on it. Study casts were made using two kinds of impression techniques. One was the conventional method that was taken using silicone impression material and an individual resin tray under connection of inter-fixture relation. The other was the improved method in which was the connection of the impression coping and the thermoformed polymethyl methacrylate tray. In addition, two different study casts were made from the improved impression body. The coordinates of the fixture on the study model were measured by three-dimensional coordinate measuring equipment. Then the distances between each fixture were calculated and compared with that of oral simulator. Accuracy of the each impression method was also assessed. Results. The differences of inter-fixture dimension between study casts and simulator in the improved impression technique showed $0.014{\pm}0.016mm$ and $0.017{\pm}0.022mm$, respectively and that of the conventional method was $0.017{\pm}0.014mm$. There was no significant difference between the improved impression technique and conventional method. Conclusion. The improved impression technique is useful for multiple support implants.

Comparison of clinical efficacy of ropivacaine and lignocaine with adrenaline for implant surgery anesthesia: a split-mouth randomized controlled clinical trial

  • Kalath, Remya Nath;Kulal, Rithesh;Gopinath, Sharika
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.21 no.4
    • /
    • pp.337-344
    • /
    • 2021
  • Background: The primary indication for using long-acting anesthetics in dentistry is extensive dental procedures that require pulpal anesthesia beyond 90 min and management of postoperative pain. Ropivacaine is an amide local anesthetic that is available at various concentrations with inherent vasoconstrictive properties at low concentrations. Ropivacaine has a 75% greater margin of safety than bupivacaine. Ropivacaine can be a good alternative to bupivacaine as a local anesthetic in dental implant surgery as it provides a longer duration of both pulpal and soft tissue anesthesia after mandibular nerve block and lowers CNS and cardiovascular toxicity. This study aimed to evaluate and compare the clinical efficacy of ropivacaine and lignocaine for implant surgery anesthesia. Methods: Fifteen patients with bilateral edentulous sites indicated for implant placement were recruited for this study. Patients aged 20-60 years of both sexes were randomly recruited. Thirty implant placements were performed in the test and control groups using ropivacaine and lignocaine with adrenaline as local anesthetics, respectively. Results: The results were analyzed statistically. The duration of anesthesia was significantly higher in the test group than in the control group. Ropivacaine was found to be superior to lignocaine in terms of the quality of anesthesia. The comparison of mean visual analog scale scores showed ropivacaine to have better anesthetic and analgesic effects than the control group. Conclusion: Ropivacaine 0.75% provides a significantly longer duration of anesthesia than lignocaine 2% with adrenaline. Ropivacaine 0.75% decreased intraoperative and postoperative analgesia compared to lignocaine 2% with adrenaline. Hence, ropivacaine 0.75% can be used as an alternative to lignocaine in implant surgeries and other intraoral surgical procedures that require a longer duration of anesthesia and analgesia.

Full mouth rehabilitation of the patient with crossed occlusion using implant fixed prosthesis: A case report (엇갈린 교합 환자에서 임플란트 고정성 보철물을 이용한 수복증례)

  • Jung, Byung-Suk;Jeon, Young-Chan;Jeong, Chang-Mo;Yun, Mi-Jung;Lee, So-Hyoun;Huh, Jung-Bo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.4
    • /
    • pp.338-346
    • /
    • 2018
  • Crossed occlusion can be treated either by overdenture and telescopic denture or by placing an implant at the edentulous area to reestablish the support on the occlusion. If alveolar bony support is sufficient and an the environment where an implant is inserted is favorable to restoring the masticatory and aesthetic function of a patient, the implant-supported fixed prosthesis can provide more definitive occlusal support and more aid for other oral functions. In this case report, a patient with a severe residual alveolar bone resorption following the extraction of teeth and who had a crossed occlusion was treated with sinus bone graft and alveolar bone augmentation in order to place the implants at prosthetically position. The definitive restoration was made to reflect the patient's occlusal and aesthetic function using the CAD/CAM double scanning method. Finally, the treatment had the masticatory and aesthetic function adequately restored, which is reported here.

Tissue conditioner in edentulous patients, depending on the time and the thickness of the changes affect the dimensional stability (무치악 환자에서 조직양화제(tissue conditioner)가 시간과 두께에 따라 체적안정성의 변화에 미치는 영향)

  • Shim, Youn-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.10
    • /
    • pp.3794-3801
    • /
    • 2010
  • This study evaluated the linear dimensional changes with the factor of time and thickness using of three commercially available tissue conditioners (Coe-Comport, Visco-Gel, Soft-Liner). The thickness of materials were changed (1.5mm, 3.0mm) and the percentage changes in dimension were measured at 1h(baseline), 12h, 24h, 3 days and 7days after specimen preparation. The obtained data were analyzed by ANOVA with the SAS/PC statistical package. From the results, large differences appear between the various tissue conditioners. The results suggested that the period recommended for forming functional impression would be 36h to 3days after insertion in the mouth. Depending on the type of tissue conditioner over time, as there were significant differences in the elastic change(p<0.05). Tissue conditioner of the 1.5mm, 3.0mm thickness were significantly different by the dimensional stability(p<0.05). Elastic deformation of the ideal itself, and resilient when compared only the look, Visco-Gel 3.0mm group, stability was the most stable volume. In addition, it is important to select tissue conditioners suitable for functional impression because of the wide range of dimensional stability among the materials.

A Statistical Survey of Foreign Bodies in Air and Food Passage (Report V) (식도 및 기도이물의 통계적 고찰(제5보))

  • 김기령;홍원표;이춘근;이정권;박기현;김상기
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1979.05a
    • /
    • pp.6.2-6
    • /
    • 1979
  • Foreing bodies of the esophagus and tracheobronchus are likely to occur whenever a child places an inedible object in the mouth and are common in the older age group particularily in edentulous individuals or preexisting disease. Our department had already reported the statistical survey at first in 1954, successively in 1962, 1963 and 1968, respectively according to the age, sex, variety of foreign bodies, location and duration of the lodgement. Now, we have experienced the new 186 cases during the consecutive 5 year period from January 1973 to December 1977 and reported as a 5th report comparing with previous report. The results were as follows. 1. In the incidence of foreign bodies, coins were the most common and pointed metal, disc, bony fragment were followed in order in the esophagus while the peanut and corn were common in the air passage. 2) 79 cases (56.4%) were males and 61 cases (43.6%) were females in the esophagus, which was not a significant difference to note. But in the air passage, males accounted for 33 cases (71.7%) compared to 13 cases (28.3%) of females. 3) In the aspect of age incidence, child 10 years or under accounted for almost all cases in the esophagus as well as in the air passage. 4) In the location of foreign bodies in the esophagus, the first narrowing was the most common, while in the air passage right bronchus had a high incidence but the difference of incidence between right bronchus and left bronchus was not remarkable. 5) The duration of lodgement was 24 hours or less in more than half of the all cases. 6) In the aspect of kind of coin, 10 won coins accounted for majority of the cases (67.0%) but the incidence of 100 won coins were tend to increase gradually in these years.

  • PDF