• Title/Summary/Keyword: Mouse Display

Search Result 102, Processing Time 0.027 seconds

Development and Application of Power System Stability Analysis Program Using OOP (개체지향기반 안정도 해석 프로그램 개발 및 적용)

  • 박지호
    • Journal of Energy Engineering
    • /
    • v.11 no.3
    • /
    • pp.194-202
    • /
    • 2002
  • In this paper, we simulate the power system transient stability of Kwang Yang steel works using object-oriented programming (OOP). OOP is a more flexible method than procedural programming. There are several advantages in dynamic system simulation using OOP, The maintenance and repair of program are easy because it is sufficient to modify necessary parts which correspond to the change of system without overall change of program. We have implemented a graphical man-machine interface (MMI) that can be used draw one-line system diagram and analyze power flow and dynamic stability. The implemented MMI also provide a graphical viewer that display dynamic stability analysis results by mouse event handling. The proposed method have been applied to Kwang Yang steel works network for on-line dynamic stability analysis. The dynamic behaviour of 17 synchronous generators and 25 synchronous motors has been studied in the Kwang Yang network.

A Study on Properties of UV-Curing Silver Paste for Touch Panel by Photoinitiator Characteristic (광개시제 특성에 따른 터치 패널용 UV 경화형 Ag 페이스트의 물성 연구)

  • Nam, Su-Yong;Koo, Yong-Hwan;Kim, Sung-Bin
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.29 no.2
    • /
    • pp.1-13
    • /
    • 2011
  • The recent spotlight on electronic touch-screen display, a rapid breakthrough in the information society is evolving. Touch panel input device such as a keyboard or mouse without the use of, the on-screen character or a specific location or object on the person's hand touches a particular feature to identify the location of a panel is to be handled. The touch screen on the touch panel is used in the Ag paste is used mostly for low-curable paste. The thermal-curing paste according to the drying process of thermal energy consumption and improve the working environment of organic solvents have problems. In this study, Ag paste used in the non-thermal curing friendly and cost-effective UV curable paste was prepared. Current commercially available thermal-curable binder, was used instead of the flow characteristics of UV-curable oligomers and monomers with functional groups to give a single conductive Ag paste with the addition of a pattern could be formed. Ag paste as a result, thermal-curing adhesive, hardness, resistance and excellent reproduction of fine patterns and was available with screen printing environmentally friendly could see its potential as a patterning technology.

Object-Oriented Stereotactic Radiosurgery Planning System (객체 지향 개념을 이용한 뇌정위 방사선 수술 계획 시스템)

  • Park, S.H.;Suh, T.S.;Suh, D.Y.;Kang, W.S.;Ha, S.H.;Kim, I.H.;Park, C.I.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1994 no.12
    • /
    • pp.85-87
    • /
    • 1994
  • In this paper, we present an object-oriented stereotactic radiosurgery planning system, which accepts medical images such as CT and angiography, transforms the coordinates to a reference frame coordinate, calculates dose distributions, and finally displays isodose curves over the images. The user finds an adequate one for radiosurgeries after performing computer simulations on different treatment parameter sets. The object-oriented design concept was fully applied to the system composed of seven manager objects of different classes: a patient information manager, a user-interface manager, a coordinate transformation manager, a blackboard manager, a dose calculation manager, an isodose curve display manager, and a report manager. All the user interactions are carried out through the use of mouse buttons. The performance of the system was verified by four physicians and two medical physicists, and now is being used in two clinical sites.

  • PDF

CTLA-4-Tg/CD-28-KO Mice Exhibit Reduced T Cell Proliferation in vivo Compared to CD-28-KO Mice in a Graft-versus-host Disease Model

  • Yoo, Jong-Sun;Lee, Yun-Jung;Yoon, Joo-Won;Hyung, Kyeong-Eun;Hwang, Kwang-Woo
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.16 no.5
    • /
    • pp.349-353
    • /
    • 2012
  • Activated T cells express inhibitory receptors such as CTLA-4 that can downregulate immune responses. Blockade of or genetic deficiency in CTLA-4 can result in autoimmunity. Therefore, strategies to increase the inhibitory function of CTLA-4 may be attractive in settings of undesirable T cell responses such as autoimmunity or transplant rejection. We have tested the hypothesis that transgenic constitutive expression of CTLA-4 can further attenuate immune responses when compared with normal inducible expression. Our results indicate that transgenic expression of CTLA-4 in mouse T cells (CTLA-4-Tg T cells) results in reduced cell cycle progression and increased apoptosis of TCR-stimulated T cells. CTLA-4-Tg T cells display reduced T cell proliferation in an in vivo model of graft versus host disease (GVHD). These results further our understanding of how CTLA-4 can be manipulated to inhibit immune responses and may help development of new therapeutic strategies for clinical settings of autoimmunity and transplantation.

HAND GESTURE INTERFACE FOR WEARABLE PC

  • Nishihara, Isao;Nakano, Shizuo
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2009.01a
    • /
    • pp.664-667
    • /
    • 2009
  • There is strong demand to create wearable PC systems that can support the user outdoors. When we are outdoors, our movement makes it impossible to use traditional input devices such as keyboards and mice. We propose a hand gesture interface based on image processing to operate wearable PCs. The semi-transparent PC screen is displayed on the head mount display (HMD), and the user makes hand gestures to select icons on the screen. The user's hand is extracted from the images captured by a color camera mounted above the HMD. Since skin color can vary widely due to outdoor lighting effects, a key problem is accurately discrimination the hand from the background. The proposed method does not assume any fixed skin color space. First, the image is divided into blocks and blocks with similar average color are linked. Contiguous regions are then subjected to hand recognition. Blocks on the edges of the hand region are subdivided for more accurate finger discrimination. A change in hand shape is recognized as hand movement. Our current input interface associates a hand grasp with a mouse click. Tests on a prototype system confirm that the proposed method recognizes hand gestures accurately at high speed. We intend to develop a wider range of recognizable gestures.

  • PDF

Development of a Patient Monitoring System Overall Architecture and Specifications (환자모니터링시스템의 개발 : 전체구조 및 기본사양)

  • 우응제;박승훈
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.1
    • /
    • pp.17-24
    • /
    • 1997
  • We have developed a patient monitoring system including module-based bedside monitors, interbed network, central stations, clinical workstations, and DB servers. A bedside monitor with a color LCD can accommodate up to 3 module cases and 21 different modules. Six different physiological parameters of ECG, respiration, invasive blood pressure, noninvasive blood pressure, body temperature, and arterial pulse oximetry with plethysmoyaph are provided as parameter modules. In a single bedside monitor, modules and a module controller communicate with IMbps data rate through an intrabed network based on RS-485 and HDU protocol. At the same time, it communicates with other bedside monitors and central stations through interbed network based on 1 OMbps Ethernet and TCP/IP protocol. Central stations using 20" color CRT monitors can be connected with many bedside monitors and they display 18 channels of waveforms simultaneously. Clinical workstations are used mainly for the review of patient datE In order to accommodate more advanced data management capabilities such as 24-hour full disclosure, we have developed a relational database server dedicated to the patient monitoring system. Software for bedside monitor, central station, and clinical workstation fully utilizes graphical user interface techniques and all functions are controlled by a rotate/push button on the bedside monitor arid a mouse on the central station and clinical workstation. The entire system satisfies the requirements of AAMI and ANSI standards in terms of electrical safety and performances.nces.

  • PDF

A Survey on the Risk Factors Analysis and Evaluation for the types of VDT Work

  • Kim, Day Sung
    • Journal of the Ergonomics Society of Korea
    • /
    • v.32 no.5
    • /
    • pp.469-474
    • /
    • 2013
  • Objective: The purpose of this study was to analyze the risk factors of MSDs for the types of office work. Background: Physical risk factors of VDT(Video Display Terminal) associated with shoulder and neck musculoskeletal disorders(MSDs) include static work postures and workstation status. Method: In this study, office work was divided into data search, data entry and design work(drawings, etc.), and then we were surveyed 7 major work places which was included these works. We recorded working postures and obtained still images, depending on the types of office work. Then, RULA(Rapid Upper Limb Assessment) and ROSA(Rapid Office Strain Assessment) were used to analysis the risk factors. Results: The results of RULA showed that design work was under risk levels and required change, but ROSA showed that data entry and design work were high risk. The RULA is to evaluate the level of risk factors based on the working posture; on the other hand, the ROSA is to consider the use of peripheral, same as chair, keyboard/mouse, monitor and computer workstations. Conclusion: Conclusions of this study, the office work is necessary to identify the risk factors caused by the use of peripheral, as well as working posture.

Web Program for Laboratory Animal Group Separation Based on Biological Characteristics (생체지표를 활용한 웹기반의 실험동물 군(郡) 분리 프로그램)

  • Kim, Chang-Hwan;Lee, Dae-Sang
    • KSBB Journal
    • /
    • v.27 no.1
    • /
    • pp.40-44
    • /
    • 2012
  • The laboratory animal group separation is dividing animal population into subgroups, which have similar average and standard deviation values among the subgroups, based on the biological characteristics such as body weight, glucose level in blood, etc. Although group separation is very important and initial step in experimental design, it needs a labor intensive process for researchers because of making similar average and standard deviation values among the subgroups using the raw biological characteristics. To reduce the labor cost and increase the efficiency of animal grouping, we developed a web program named as laboratory animal group separation (LAGS) program. This LAGS uses biological characteristics of population, number of group, and the number of elements per each subgroup as input data. The LAGS automatically separates the population into each subgroup that has similar statistical data such as average and standard deviation values among subgroups. It also provides researchers with the extraordinary data generated in the process of grouping and the final grouping results by graphical display. Through our LAGS, researchers can validate and confirm results of laboratory animal group separation by just a few mouse clicks.

An Evaluation of Human Sensibility on Perceived Texture for Real Haptic Representation (사실적인 햅틱 표현을 위한 질감지각 감성 평가)

  • Kim, Seung-Chan;Kyung, Ki-Uk;Sohn, Jin-Hun;Kwon, Dong-Soo
    • Journal of KIISE:Software and Applications
    • /
    • v.34 no.10
    • /
    • pp.900-909
    • /
    • 2007
  • This paper describes an experiment on the evaluation of human sensibility by monitoring responses to changes In the frequency and amplitude of a tactile display system. Preliminary tasks were performed to obtain effective adjectives concerning texture perception. The number of collected adjectives was originally 33. This number of adjectives was reduced to 14 by a suitability survey that asked whether an adjective is suitable for expressing a texture feeling. Finally after performing a semantic similarity evaluation, the number of adjectives was further reduced to ten and these ten were used in the main experiment. In the main experiment, selected sandpaper types and 15 selected combinations of frequencies and amplitudes of a tactile display were utilized to quantitatively evaluate the ten adjectives using a bipolar seven-point scale. The data show that a relationship exists between the independent variables(frequency, amplitude, and grit site) and the dependent variable(perceived texture). That is, the change of frequency and amplitude is directly related to perceived roughness or essential elements of human tactile sensitivity found in the preliminary experiment.

A study on the search and selection processes of targets presented on the CRT display (컴퓨터 모니터에 제시된 표적의 탐색과 선택과정에 관한 연구)

  • 이재식;신현정;도경수
    • Korean Journal of Cognitive Science
    • /
    • v.11 no.2
    • /
    • pp.37-51
    • /
    • 2000
  • The present study compared computer users target-selection response patterns when the targets were varied in terms of their relative location and distance from the current position of the cursor. In Experiment 1, where the mouse was used as an input device, the effects of different directions and distances of simple target(small rectangle) on target-selection response were investigated. The results of Experiment 1 can be summarized as follows: (1) Overshooting was more frequent than either undershooting or correct movement and (2) this tendency was more prominent when the targets were presented in the oblique direction or in farther location from the current cursor position. (3) Although the overshooting and undershooting were more frequent in the oblique direction, the degree of deviation was larger in horizontal and vertical direction. (4) Time spent in moving the mouse rather than that spent in planning, calibrating or clicking was found to be the most critical factor in determining total response time. In Experiment 2, effects of the font size and line-height of the target on target-selection response were compared with regard to two types of input devices(keyboard vs. mouse). The results are as follows: (1) Mouse generally yielded shorter target-selection time than keyboard. but this tendency was reversed when the targets were presented in horizontal and vertical directions. (2) In general, target-selection time was the longest in the condition of font size of 10 and line-height of 100%, and the shortest in the condition of font size of 12 and line-height of 150%. (3) When keyboard was used as the input device, target-selection time was shortest in the 150% line-height condition, whereas in the mouse condition, target-selection time tended to be increased as the line-height increased. which resulted in the significant interaction effect between input device and line-height. Finally, several issues relating to human-computer interaction were discussed based on the results of the present study.

  • PDF