모터부하 특성에 따른 국내 전력계통의 전압 지연 회복 현상 분석 (An Analysis of Delayed Voltage Recovery Phenomenon according to the Characteristics of Motor Load in Korean Power System)

  • 이윤환
    • 전기학회논문지P
    • /
    • 제65권3호
    • /
    • pp.178-182
    • /
    • 2016
  • FIDVR(Fault Induced Delayed Voltage Recovery) is a phenomenon that recovery of the system voltage level delays after the fault. Cause of FIDVR phenomenon is motor load characteristic about voltage and reactive power. In low voltage condition, the motor go to stall state that consume large amount of reactive power. As a result, the voltage recovery problem is that of repeated occurrences of sustained low voltage following faults on the system. In this paper, analysis the characteristics of the motor load. And using the korean power system actual data, perform a case studies to voltage delay recovery phenomenon alleviation method. Change of each parameters by analyzing the effect on system and selecting an influence parameter. In addition, dynamic characteristic analysis of the resulting difference in the proportion by the motor load in power systems, considering the effect on the voltage stability.

대용량 유도전동기 기동 개선에 관한 연구 (A Study on Improving High-Power Induction Motor Starting)

  • 손석금
    • 한국정보전자통신기술학회논문지
    • /
    • 제9권2호
    • /
    • pp.178-184
    • /
    • 2016
  • 본 논문에서는 전력에너지를 사용하는 산업체의 전동기용량이 점차 증가하고 있다. 전동기는 기동시 기동전류로 전압강하가 발생한다. 이 기동전류가 전력계통에서 대형 전동기 기동 시 전압강하로 기동이 어려워 인접한 전력계통에 나쁜 영향을 미치게 된다. 또한 전동기는 부하의 크기에 따라 토크를 내는 것으로 토크의 크기에 따라 속도가 변하고 속도는 전동기 기동에 중요하다. 일반적으로 변압기나 비상발전기로부터 전동기까지의 거리가 짧으며 전동기용량이 작아 기동에 대한 어려움이 없으나 산업설비 등에 많이 이용되는 대용량 전동기의 기동특성에 대한 이론과 실제의 운전특성을 측정 분석하였다. 따라서 이번 연구는 전동기 기동 시 속도와 토크에 관계와 대용량 전동기 기동을 위한 분석과 전동기 기동 해석에 대해 연구하였다.

유도전동기 부하 고려 시 저전압 부하차단을 이용한 전력계통 안정도 향상 방안 (Using the Under Voltage Load Shedding for Stability Enhancement of Power Systems Considering Induction Motor Load)

  • 이윤환
    • 전기학회논문지P
    • /
    • 제65권1호
    • /
    • pp.1-6
    • /
    • 2016
  • Recently, proportion of the induction motor load is gradually increased. When a contingency in the power systems, it has been discovered phenomenon that the voltage is delayed recover caused mechanical characteristics of the induction motor load. It can be a serious impact on the voltage stability of the power system considering induction motor load. The scheme to mitigate this phenomenon tripping off the motors to prevent voltage drop and delayed voltage recovery on the load demand side. Fault induced delayed voltage recovery phenomenon is caused by stalling of small induction motor load in transmission level contingencies. In this paper, fault induced delayed voltage recovery phenomenon mitigation method implementation under voltage load shedding on the korean power system considering induction motor load.

자동차 전장에서 윈도우 모터 조립 부품의 생산 (Production of Window Motor Assembly Parts in Automotive Body)

  • 이정익
    • 한국융합학회논문지
    • /
    • 제3권4호
    • /
    • pp.29-34
    • /
    • 2012
  • 자동차는 2만 여개가 넘는 부품들로 구성되어 있다. 또한, 새시와 함께 자동차 내부에는 조향장치, 파워장치, 도어 록 장치 등 많은 전기 전자 및 센서들이 부가되어 수송 외 운전자가 주행 중 운전을 용이하게 수행할 수 있는 여러 가지 장치들이 별도로 차체내부 혹은 외부에 부착되어 있다. 그 가운데 자동차의 도어 유리 부위는 제작 초기에는 운전자가 직접 휠을 회전시켜 유리문을 상하로 개폐하였으나 최근 들어 모터, 센서, 스위치 류 등의 발달로 버튼하나로 문을 상하로 개폐시키는 방법을 사용하게 되었다. 유리문을 상하로 개폐시키는 조립부위를 자동차에서는 power window motor assembly라고 이를 개발하는 것이 본 연구의 목적이다. 현재는 anti-pinch type power window motor에 ECU(Electronic Control Unit) system이 국내에서 개발되지 못하고 있다. 뿐만 아니라, 이 연구에서는 CAE 해석과 개발을 통해 anti-pinch power motor gear housing 및 cylindrical gear를 국산화 개발하고 ECU 일체형 적용을 함으로 인해 조립공정의 단순화 및 원가절감에 기여하고자 한다.

The Design of Long-Stator Linear Motor Drives for RailCab Test Track

  • Grotstollen Horst
    • Journal of Power Electronics
    • /
    • 제5권2호
    • /
    • pp.166-172
    • /
    • 2005
  • The basic equations of a doubly-fed long-stator linear motor for a shuttle-based railway system are established. They show which degrees of freedom exist for controlling the motor. The ratio of stator and rotor current proves to be an important parameter in determining the design of motors, converters and mechanics.

물류 시스템 적용 유도전동기의 전압강하와 역률 보상 관계 (Voltage Drop and Power Factor Compensation Relation of Induction Motor applied to Logistics System)

  • 김종겸
    • 전기학회논문지P
    • /
    • 제67권3호
    • /
    • pp.155-159
    • /
    • 2018
  • Recently, the expansion or establishment of facilities for the logistics system is increasing. Conveyor facilities play a major role in sorting and transporting logistics. Induction motors are widely used for the operation of these conveyor systems. In the logistics system, a large number of induction motors are used. These motors have a considerable distance from the power source side and have a low power factor. The installation position for the power factor compensation of the induction motor is very important. Since the voltage drop depends on the length of the line, it is an important parameter in capacitor capacity determination for power factor compensation. The capacity of the capacitors installed to compensate the power factor of the inductive load should be designed to the extent that self-excitation does not occur. In this study, we analyze the method of compensating the proper power factor considering the voltage drop and the installation position of the induction motor in the logistics system.

High-Performance Metal-Substrate Power Module for Electrical Applications

  • Kim, Jongdae;Oh, Jimin;Yang, Yilsuk
    • ETRI Journal
    • /
    • 제38권4호
    • /
    • pp.645-653
    • /
    • 2016
  • This paper demonstrates the performance of a metal-substrate power module with multiple fabricated chips for a high current electrical application, and evaluates the proposed module using a 1.5-kW sinusoidal brushless direct current (BLDC) motor. Specifically, the power module has a hybrid structure employing a single-layer heat-sink extensible metal board (Al board). A fabricated motor driver IC and trench gate DMOSFET (TDMOSFET) are implemented on the Al board, and the proper heat-sink size was designed under the operating conditions. The fabricated motor driver IC mainly operates as a speed controller under various load conditions, and as a multi-phase gate driver using an N-ch silicon MOSFET high-side drive scheme. A fabricated power TDMOSFET is also included in the fabricated power module for three-phase inverter operation. Using this proposed module, a BLDC motor is operated and evaluated under various pulse load tests, and our module is compared with a commercial MOSFET module in terms of the system efficiency and input current.

3D Finite Element Analysis of Contact-less Power Supply with Linear Servo Motor

  • Woo, Kyung-Il;Park, Han-Seok;Park, Hyeong-Beom
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권2호
    • /
    • pp.190-196
    • /
    • 2007
  • This paper presents the 3D finite element analysis of the Contact-less Power Supply(CPS) with linear servo motor. The primary, secondary self and leakage inductances of the contact-less power supply and the capacitances of a resonant circuit are calculated by the finite element analysis using current source. The voltage source is used to do accurate analysis of the characteristics of the contact-less power supply. The CPS with the linear servo motor is proposed. The characteristics analysis of the contact-less power supply considering the linear servo motor is done.

The Energy Saving for Separately Excited DC Motor Drive via Model Based Method

  • Udomsuk, Sasiya;Areerak, Kongpol;Areerak, Kongpan
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권2호
    • /
    • pp.470-479
    • /
    • 2016
  • The model based method for energy saving of the separately excited DC motor drive system is proposed in the paper. The accurate power loss model is necessary for this method. Therefore, the adaptive tabu search algorithm is applied to identify the parameters in the power loss model. The field current values for minimum power losses at any load torques and speeds are calculated by the proposed method. The rule based controller is used to control the field current and speed of the motor. The experimental results confirm that the model based method can successfully provide the energy saving for separately excited DC motor drive. The maximum value of the energy saving is 48.61% compared with the conventional drive method.

축전지 전원을 사용한 소형선박 추진용 BLDC모터의 전력변환방식에 따른 효율 비교 및 성능 추정 (Efficiency Comparison according to Power Conversion Method and Performance Estimation for Battery Source BLDC Motor Propulsion System of Small Ships)

  • 정태영;정석권
    • 동력기계공학회지
    • /
    • 제14권1호
    • /
    • pp.27-33
    • /
    • 2010
  • We investigate some operation characteristics and energy efficiency of the BLDC motor system driven by different two types power conversion method depends on same battery source for applying to electrical motor propulsion system of a small ship. Also, we suggest an estimation manner of operating performances such as total running distance and operating speed of ships from basic discharge voltage characteristics of batteries. Through some experiments, direct power conversion was better than indirect method on the view point of energy efficiency and the voltage discharge characteristics could be used as important design factor for estimating operating performances of small ships driven by electrical motors.