• Title/Summary/Keyword: Motor current

Search Result 3,084, Processing Time 0.025 seconds

A New Approach of BLDC Motor Using Unidirectional Current in the Driver Circuit and its Future Prospects

  • Yasuhiro, Komatsu;Zawawi, Syed Abdul Kadir
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.1 no.1
    • /
    • pp.91-98
    • /
    • 2012
  • Climate change and other pollutions make a huge demand of environment friendly and high efficient motors especially Brushless DC (BLDC) motors. Generally, bidirectional energized BLDC motors are used widely; however, inverter devices used in the driver put fear of being effected by noise. This paper proposes unidirectional energized BLDC motor which utilizes asymmetrical H-bridge circuit as the driver circuit. The Minato motor is one of the pioneers in unidirectional energized system. The use of bar magnets in the rotor is one of the biggest disadvantages of the motor. We proposed using tabular magnets. The paper compares the power consumption and efficiency of the Minato motor and the proposed motor. During high speed rotation, undesirable armature current is generated that has a deceleration characteristic. This current lowers the motor's efficiency. In this paper, we propose the solutions and show comparison through equations of the copper loss ratio for the Minato and our proposed motors. The third motor, which has the highest efficiency, was discovered during examination of the equations.

Analysis and Control of an Unsymmetrical 3-Phase VR Type Self Bearing Step Motor (비대칭 3상 가변형 셀프 베어링 스텝모터의 해석 및 제어)

  • Kim, Dae-Gon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.7 no.10
    • /
    • pp.806-811
    • /
    • 2001
  • The analysis and control algorithm of a new type unsymmetrical self-bearing step motor is presented. The motor actuator is used for both motor and bearing functionality without any redundant coil windings or redudant electromagnets for bearing functionality. Self bearing step motor layout and control current generation method for unsymmetrical position of electromagnets are described. This new current generation method without additional current for bearing functionality leads to minimize the power loss. As the result of the unbalance response approach, the constant torque is possible, even though the bearing functionality is added or not.

  • PDF

Parameters Estimation and Torque Monitoring for the Induction Spindle Motor (주축용 유도전동기의 매개변수 추정과 토크 모니터링 시스템)

  • Kwon, Won-Tae;Kim, Gyu-Sik
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.3
    • /
    • pp.238-244
    • /
    • 2004
  • To monitor the torque of an induction motor using current, the accurate identification of the motor parameters is very important. In this study, the motor parameters such as rotor resistance, stator and rotor leakage inductance, mutual inductance are estimated for torque monitoring and indirect vector control. Estimated parameters are used to monitor the torque of vector controlled induction motor without any speed measuring sensor. Stator current is measured to estimate the magnetizing current which is used to calculate flux linkage, rotor velocity and motor torque. From the experiments, the proposed method shows a good estimation of the motor parameters and torque under the normal rotational speed.

A Novel Current Sensing Method for Low-Cost Vector-Controlled Inverter of AC Motor (저가형 교류전동기 벡터제어 인버터를 위한 새로운 전류측정 방법)

  • Lee, Won-Il;Yoon, Duck-Yong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.7
    • /
    • pp.950-955
    • /
    • 2013
  • This paper proposes a new low-cost current detection method to implement vector-controlled inverter of 3-phase induction motor or permanent-magnet synchronous motor using 2 shunt resistors instead of expensive Hall current sensors. The proposed method can detect perfect phase currents without current-immeasurable area in all operating conditions of motor. This method uses 2 shunt resistors in Hall current sensor positions conventionally used to detect phase currents. Therefore, it requires accurate analog differential amplifiers to detect voltages across shunt resistors at high electric potential to ground. We show the good solutions which are implemented by voltage-divider resistors networks and the instrumentation amplifiers using several Op Amps at cheap price. Computer simulations and experiments were performed to confirm the effectiveness of proposed method. These results show that proposed method can perfectly detect phase currents without current-immeasurable area in all operating conditions of motor.

Current Sensorless Algorithm of PMSM Drive for Current Fault Tolerant (고장허용 운전을 위한 영구자석동기전동기의 전류센서리스 알고리즘)

  • Lim, J.W.;Yoon, D.K;Cho, Y.H.
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.206-207
    • /
    • 2017
  • Motor drive has used in many industrial application. In this situation the motor performance reliability has been more and more important. Sensor fault is critical defect to motor performance especially current sensor. Therefore this paper is dealing with SPMSM current sensorless algorithm in Luenberger estimation method with only a phase current information for current sensor fault situation. And the algorithm is verified with experimental results.

  • PDF

Torque Ripple Reduction of BLDG Motors Using Single DC-Link Currant Sensor (DC Link단 단일 전류센서에 의한 브러시리스 직류 전동기의 토크 리플 저감)

  • Baek, Dae-Jin;Won, Chang-Hee;Lee, Kyo-Beum;Choy, Ick;Song, Joong-Ho;Yoo, Ji-Yoon
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.974-976
    • /
    • 2001
  • This paper presents a method to reduce commutation torque ripples occurred during commutation in brushless do motor drives using a single DC-link current sensor. In brushless dc motor drives with a single dc current sensor instead of 3-phase line current sensors, it is noted that dc-link current sensor cannot give any information corresponding to the motor currents during line current commutation intervals. A new technique to resolve such a problem is dealt with based on a deadbeat current control in which motor armature voltage command is computed from a dc-link current reference, an actual current and counter emf voltage. The simulation results show that the proposed method reduces the torque ripple significantly.

  • PDF

Sensorless Control of BLDC Motor using d-q Synchronously Rotating Reference Frame Concept (d-q 동기좌표 변환 개념을 이용한 BLDC 전동기의 센서리스)

  • Moon, Jong-Joo;Heo, Hong-Jun;Kim, Jang-Mok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.3
    • /
    • pp.232-238
    • /
    • 2015
  • A sensorless control algorithm of brushless DC (BLDC) motors with a model current based on 120 degree conduction mode is proposed in this paper. The rotor speed and position can be estimated using the current model of BLDC motor, which is a modified version of the conventional current model of permanent magnet synchronous motor. The rotor speed and position can be obtained using the difference of the actual current and the model current. The position error caused by the parameter errors of the model current is compensated using a PI controller and the feedback loop of the real current. The validity of the proposed sensorless control algorithm is verified through simulation.

Simulation of Thermal Trip in Mill Driver (과부하 운전 압연용 전동기의 과열 정지 시뮬레이션)

  • Lee SeungHee;Han Muho;Lee Wangha;Lee Chiwan
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.288-291
    • /
    • 2001
  • In steel plant, load torque of mill driver motor is changed periodically because working state and idle state are repeated and load current of working state is necessarily higher than rated motor current. The over current limiter is one of the basic thermal protection method from over heating. In this paper, we analyzed the structure of over current limiter for motor and motor driver systems, developed over current limiter with same operation and structured warning system of action of over current limiter. As using this warning system, we can avoid abrupt plant stop by over current limiter in mill driver and lessen producing loss by plant stop. The developed warning system of action of over current limiter is exactly inspected by computer simulation md analysis of acquired data.

  • PDF

A Study on Reduction of Current Ripple due to Commutation in Brushless DC motor (브러시리스 직류전동기의 전환에 의한 전류 맥동 저감에 관한 연구)

  • Lee, Gwang-Un;Park, Jeong-Bae;Yeo, Hyeong-Gi;Yu, Ji-Yun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.9
    • /
    • pp.490-497
    • /
    • 1999
  • This paper presents a novel current control method to reduce the current ripple due to commutation in brushless DC motor fed with unipolar PWM voltage source inverter. The proposed current control method can reduce the current ripple due to commutation in high speed range where the DC link voltage of the inverter is less than four times of the phase back-emf. The effectiveness of the proposed current control method is verified with digital simulations and experiments on the 250W brushless DC motor drive systems.

  • PDF

Coreless Hall Current Sensor for Automotive Inverters Decoupling Cross-coupled Field

  • Kim, Ho-Gi;Kang, Gu-Bae;Nam, Dong-Jin
    • Journal of Power Electronics
    • /
    • v.9 no.1
    • /
    • pp.68-73
    • /
    • 2009
  • Automotive inverters may require current sensors for motor torque control, especially, in applications of hybrid electric vehicles or fuel cell vehicles. In this paper, to achieve a compact, integrated and low cost current sensor, a hall current sensor without magnetic core is introduced for integrating an automotive inverter. The compactness of the current sensor is possible by using integrated magnetic concentrators based on the Hall effect. Magnetic fields caused by three-phase currents are analyzed and a magnetic shield design is proposed for decoupling the cross-coupled field. It offers galvanic isolation, wide bandwidth (>100kHz), and accuracy(< 1%). Using 2D FEM analysis, its performance is demonstrated with design parameters at a U-shaped magnetic shield. The proposed coreless current sensor is tested with rated current to validate the linearity and accuracy.