• Title/Summary/Keyword: Motor control method

Search Result 2,634, Processing Time 0.042 seconds

Electrodermal Responses in Patients with Posttraumatic Stress Disorder by Motor Vehicle Accidents ; a Pilot Study (교통사고에 의한 외상 후 스트레스장애 환자의 피부 전기반응 : 예비 연구)

  • Seo, Ho-Jun;Jung, Young-Eun;Lee, Hye-Won;Moon, Hyun-Jin;Park, Ju-Mi;Kim, Seon-Kyung;Chae, Jeong-Ho
    • Anxiety and mood
    • /
    • v.3 no.2
    • /
    • pp.104-109
    • /
    • 2007
  • Objective : In the present study, we evaluated the differences between the skin electric conductance of patients with posttraumatic stress disorder (PTSD) and normal controls in order to determine the possibility of using skin electric conductance as a diagnostic measure. Method : The PTSD group included 14 subjects who were diagnosed with PTSD in St. Mary's Hospital after a motor vehicle accident, and the normal control group included 12 healthy subjects. The conductivity and capacitance of both groups were measured twice, and the data from each group was compared. Results : There was no significant difference in gender, but the patients in the PTSD group were significantly older than those in normal control group. The activity (conductivity) between the left head-left hand, right hand-right head, and right head-left head was significantly elevated in the PTSD group as compared with the normal control group. In addition, the reactivity (capacitance) between the right head-left head, left head-left hand, right hand-left hand, right hand-right foot, right foot-left foot, and left foot-left hand was significantly elevated in the PTSD group. Conclusion : In this study, the skin electric conductance of the patients with PTSD was significantly elevated in comparison with that of the healthy subjects. Although there were some limitations of this study, the results of this study suggested that skin electric conductance can be used to evaluate elevated psychophysiological responses in patients with PTSD. Future studies with more subjects and more structure are needed in order to confirm our results.

  • PDF

A Review of Acupuncture and Moxibustion for the Treatment of Parkinson's Disease (파킨슨병의 침구치료 동향에 대한 고찰)

  • Lee, Eun;Kang, Ki-Wan;Kim, Lak-Hyung;Kang, Sei-Young;Sun, Seung-Ho;Han, Chang-Ho;Jang, In-Soo
    • The Journal of Internal Korean Medicine
    • /
    • v.35 no.1
    • /
    • pp.12-23
    • /
    • 2014
  • Objectives : The purpose of this study was to report possibility of acupuncture or moxibustion for the treatment of Parkinson's disease (PD) by reviewing literature about its effectiveness. Methods : In this review, PubMed, SCOPUS, Science Direct and CINAHL of EBSCOhost were used to search medical journals, using keywords "Parkinson's disease and acupuncture" and "Parkinson's disease and moxibustion". The search range included randomized controlled trials (RCT) about Parkinson's disease combined with another disease and other treatments with acupuncture or moxibustion. Non-randomized controlled trial (nRCT), case study, animal experiment, human experiment, review, survey, essay, letter, and protocol for review were excluded. Results : From 311 studies, 111 were selected during the title and the screening. Finally, 16 RCTs (15 for acupuncture research and one for moxibustion) were included in this review, after scanning and matching the inclusion and exclusion criteria. The number of patients varied between 5 and 88. A total of 12 studies using electroacupuncture (EA) were classified into acupuncture studies. The body acupuncture studies numbered 4, scalp acupuncture 4, body and scarp acupuncture mixed studies 4, and bee venom, ear and abdomen acupuncture were each one study. In evaluation methods, total effective rate method was used in 9 studies, the Unified Parkinson's Disease Rating Scale (UPDRS) was used in 8, and the Webster score in 2. In addition, the Berg balance scale (BBS), 30 m walking time, steps to walk 30 m, PD motor function score, and Motor Performance Series by Schoppe (MLS) method were used for evaluation. In 15 of the 16 studies, the verum acupuncture group showed significant improvement compared with the control. In 9 studies using total effective rate method, the effective rate was reported as 80.0-97.3% in verum acupuncture groups and 52.6-86.4% in controls. Conclusions : Acupuncture may be a plausible alternative method to care for the long term symptoms and treat movement impairment of Parkinson's disease. However, to confirm this result, high quality studies including randomized, placebo-controlled double-blind trials are warranted.

Experimental Study of System Identification for Seismic Response of Building Structure (건축구조물의 지진응답제어를 위한 시스템 식별의 실험적 연구)

  • 주석준;박지훈;민경원;홍성목
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.3 no.4
    • /
    • pp.47-60
    • /
    • 1999
  • The stability and efficiency of structural control systems depend on the accuracy of mathematical model of the system to be controlled. In this study, state equation models of a small scale test structure and an AMD(active mass damper) are obtained separately using OKID(observer/Kalman filter identification) which is a time domain system identification method. The test structure with each floor acceleration as outputs is identified for two inputs - the ground acceleration and the acceleration of the moving mass of AMD relative to the installation floor - individually and the two identified state equation models are integrated into one by model reduction method. The AMD is identified with the motor control signal as an input and the relative acceleration of the moving mass as an output, and it is shown that the identified model has large damping ratio and phase shift. The transfer functions and the time histories reconstructed from the identified models of the test model and the AMD match well with those measured from the experiment.

  • PDF

Design of Stiffeners for Reducing Resonant Vibration of Large Vertical Pumps and Its Performance Verification (대형 입형펌프 운전 중 공진현상의 진동 저감을 위한 스티프너 설계 및 성능 검증)

  • Ryu, Kil-Su;Bong, Suk-Keun;Han, Seung-Woo;Roh, Cheol-Woo;Lee, Dong-Min;Lee, Jung-Woo;Park, Junhong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.1
    • /
    • pp.65-72
    • /
    • 2013
  • This case study presents a practical method to reduce resonant vibration of large vertical pumps. The pumps are driven at 400 rpm rated speed by induction motor. The vibration was not significantly large when operated at this rated speed. Large vibration was occurred when the pump was operated below the rated speed for flow control. Due to the large vibration resonance, variable speed operation of the pump was not possible for several months at worst cases. To find an efficient vibration control method, the flexural responses of pumps for both normal and transient operations were measured. The measured modal characteristics were compared with those of finite element analysis. When the pump was operated at a specific rpm, the natural mode whose resonance frequency is twice the rotating angular speed induced the large vibration. The retrofit utilizing stiffeners to reduce this resonant vibration were performed. Effects of designed stiffeners on reducing vibration were validated through tests after actual installation.

A Study on the DBS Receive Tracking Antenna Apparatus on a Ship by the Az/El Mount (Az/El 마운트에 의한 선박용 DBS 수신추적안테나 장치에 관한 연구)

  • 최조천;양규식
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.1 no.2
    • /
    • pp.209-220
    • /
    • 1997
  • DBS offers actual services to mass-media and communication system of very broad region in information society. Especially, the DBS is the only system to access TV broadcasting service on a sailing ship. But the ship's DBS receiver is required a complex antenna tracking system because ships are under complex moving such as pitch, roll, and yaw etc. This study is motivated to develop a tracking antenna system to receive the koreasat on small silo ship. Therefore, this system is researched to small size, light weight, simple operation, and low cost of the product. The mount structure have been a compact size and easy operation to the Az/El 2-axis type which is operated by step motor. And it is very useful on a ship in the around sea of korean peninsula. The antenna has a plate type of micro-strip array, and is a domestic production. The vibration sensor is selected to gyro sensor of ultra-sonic rate type for ship's moving control. Tracking method is used the step-tracking algorithm, and the ship's moving compensation is adapted to the closed loop control method by ship's moving detection of gyro sensor. Tracking test is operated by the ship's moving simulator, we examined the actual receiving state on sailing shipboard in the near sea of korean peninsular.

  • PDF

Effect of Kinetic Degrees of Freedom on Hierarchical Organization of Multi-element Synergies during Force Production and Releasing Tasks

  • Kim, Kitae;Song, Junkyung;Park, Jaebum
    • Korean Journal of Applied Biomechanics
    • /
    • v.30 no.2
    • /
    • pp.131-144
    • /
    • 2020
  • Objective: The purpose of this study was to examine the effect of degrees of freedom on the multi-synergies in two hierarchies of human hand system during force production and releasing tasks. Method: In this study, the constrained movements of the aiming and releasing actions using both hands and fingers during archery-like shooting were implemented as experimental tasks. The participants produced a pulling force holding the customized frame (mimicking an archery bow, with a set of force transducers) and kept it consistently for about 5 seconds, and released fingers as quickly as possible in a self-paced manner within the next 5 seconds. An analytical method based on the uncontrolled manifold hypothesis was used to quantify the stability index (synergy index) in two hierarchies including two hands (upper hierarchy) and individual fingers (lower hierarchy). Results: The results confirmed that the positive synergy pattern showed simultaneously at the upper and lower hierarchies, and the kinetic degrees of freedom were associated with the increment of hierarchical synergy indices and the performance indices. Also, the synergy indices of both hierarchies showed significant positive correlations with the performance accuracy during the task. Conclusion: The results of this study suggest that the human control system actively uses extra degrees of freedom to stabilize task performance variables. Further increasing the degree of freedom at one level of hierarchy induces positive interactions across hierarchical control levels, which in turn positively affects the accuracy and precision of task performance.

Record and Replay Motion Implementation to Modular Toys using Two Potentiometers (두개의 전위차계를 이용한 모듈형 완구의 동작 저장 및 반복 재생 동작의 구현)

  • Lee, JinKyu;Lee, BoHee;Kim, JongTae;Park, JiYoup;Kong, JungShik
    • Journal of Convergence for Information Technology
    • /
    • v.7 no.2
    • /
    • pp.59-65
    • /
    • 2017
  • In order to realize the operation of the creative modular toy, it is required to record the motion and to read and repeat the motion. At this time, a control potentiometer is used to read the absolute angle of rotation of the toy motion output shaft. However, the unstable part of the sensing area of the potentiometer is present in a certain region, which may lead to instability of the motor control. In this paper, we propose an algorithm to find the absolute angle of one rotation by reading two stable potentiometers on one axis and reading each stable region. We also describe the correction algorithm that is needed to perform multiple rotations. The proposed method is applied to Topobo modular toys to record the operation and perform iterative operation. In addition, multi-turn operation is recorded and operated to suggest the usefulness of the proposed method. In the future, we will expand the functions of recording and playback through various actions.

Enhancing Shoulder External Rotator Electromyography Activity During Sitting External Rotation Exercise: The Impact of Biofeedback Training

  • Il-young Yu;Min-joo Ko;Jae-seop Oh
    • Physical Therapy Korea
    • /
    • v.30 no.3
    • /
    • pp.237-244
    • /
    • 2023
  • Background: The external rotation (ER) exercise in performed at a 90° abduction of the shoulder joint is an effective to strengthen the infraspinatus. However, failure of the humeral head to control axial rotation during exercise can be increased the posterior deltoid over activity. Biofeedback training is an effective method of promoting motor learning and control it could look forward to activate the infraspinatus selectively by controlling the humeral head during exercise. Objects: The aim of this study was investigated that whether biofeedback for axial rotation was effective to activate selectively the infraspinatus during ER exercise. Methods: The 15 healthy males participated, and all subjects performed both ER exercise in a sitting position with shoulder abducted 90° under conditions with and without axial rotation biofeedback. Exercise was performed in a range of 90° ER, divided into three phases: concentric, isometric, and eccentric. The infraspinatus and posterior deltoid muscle activity were observed using surface electromyography. Results: Both infraspinatus activity (p < 0.01) and infraspinatus to posterior deltoid activity ratio (p = 0.01) were significantly higher with biofeedback however, posterior deltoid activity was significantly lower with biofeedback (p = 0.01). The infraspinatus muscle activity and muscle activity ratio were the highest in the isometric contraction type, and there were significant differences for all contraction types (p < 0.05). Whereas, the posterior deltoid activity was the lowest in the isometric contraction type, and showed a significant difference between isometric and other two contraction types (p < 0.05), but no significant different between concentric and eccentric contraction. Conclusion: Our results indicate that the axial rotation biofeedback during sitting ER exercise might be effective method to activating selective infraspinatus muscle and recommended to enhance the dynamic stability of the shoulder joint.

STUDY ON THE RELATIONSHIP BETWEEN SEROTONIN SYSTEM AND PSYCHOPATHOLOGY IN TOURETTE'S DISORDER (Tourette씨병의 Serotonin계와 정신병리와의 상호관계에 관한 연구)

  • Cho, Soo-Churl;Shin, Yun-O;Suh, Yoo-Hun
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.7 no.1
    • /
    • pp.77-91
    • /
    • 1996
  • In order to elucidate the biological etiology and the effects of comorbidity on biological variables in tic disorders, plasma serotonin (5-hydroxlfryptamine, 5-HT) and 5-hydroxy- indoleacetic acid (5-HIAA) we.e measured in 87 tic disorders and 30 control subjects. The 87 tic disorder were composed of 45 Tourette's disorder(TS), 22 chronic motor tic disorders (CMT) and 20 transient tic disorders (TTD). Among these patients,43 patients were pure tic disorder (PT), 28 subject also had attention deficit hyperactivity disorder (T+ADHD) and 16 subjects had obsessive compulsive disorders (T+ OCD) as comorbid disorders. The results are summarized as follows : 1) Plasma 5-HT levels showed significant positive correlations with plasma 5-HIAA levels (Pennon r=0.77, p<0.05). 2) Plasma 5-HT and 5-HIAA levels showed no significant correlation with age in tic disorders. 3) Plasma 5-HIAA and 5-HT levels showed no significant correlations with age in control subjects. 4) There was significant difference in plasma 5-HT levels among TS, CMT, TTD and control groups (ANOVA F=34.48, df=3, 113, p<0.01), and post-hoc test using Scheffe method showed significant differences between control and TS, control and CMT, control and ITD groups. But, post-hoc test showed no significant differences between TS and CMT, TS and TTD, CMT and TTD groups. 5) There was significant difference in plasma 5-HIAA levels among TS, CMT, TTD and control groups (ANOVA F=26.48, df=3, 113, p<0.01), and post-hoc test using Scheffe method showed significant differences between control and TS, control and CMT, control and TTD groups. But, post-hoc test showed no significant differences between TS and CMT, TS and TTD, CMT and TID groups.f) There was significant difference in plasma 5-HT and 5-HIAA levels among PT, T+ADHD, T+OCD and contol groups (ANOVA 5-HT, F=37.59, df=3, 113, p<0.01, 5-HIAA, F=27.37, df=3, 113, p<0.01), and post-hoc test using Scheffe method showed signiscant differences between control and PT, control and T+ADHD and control and T+OCB. But, post-hoc test showed no significant differences between PT and T+ADHD, PT and T+ OCD and T+ADHD and T+ OCD. These results show that decreased 5-HT and 5-HIAA levels may play a role in the genesis of tic disorders, but these findings have no significant correlations with the severity of tic disorders. And the comorbid disorders of tics may have minimal effects on the biochemical abnormalities. Future studies must be focused on the effects of serotonin agonists and antagonists on tic disorders and molecular biological methodology may enhance to elucidate the mechanisms of these abnormal findings.

  • PDF

Driving Control System applying Position Recognition Method of Ball Robot using Image Processing (영상처리를 이용하는 볼 로봇의 위치 인식 방법을 적용한 주행 제어 시스템)

  • Heo, Nam-Gyu;Lee, Kwang-Min;Park, Seong-Hyun;Kim, Min-Ji;Park, Sung-Gu;Chung, Myung-Jin
    • Journal of IKEEE
    • /
    • v.25 no.1
    • /
    • pp.148-155
    • /
    • 2021
  • As robot technology advances, research on the driving system of mobile robots is actively being conducted. The driving system of a mobile robot configured based on two-wheels and four-wheels has an advantage in unidirectional driving such as a straight line, but has disadvantages in turning direction and rotating in place. A ball robot using a ball as a wheel has an advantage in omnidirectional movement, but due to its structurally unstable characteristics, balancing control to maintain attitude and driving control for movement are required. By estimating the position from an encoder attached to the motor, conventional ball robots have a limitation, which causes the accumulation of errors during driving control. In this study, a driving control system was proposed that estimates the position coordinates of a ball robot through image processing and uses it for driving control. A driving control system including an image processing unit, a communication unit, a display unit, and a control unit for estimating the position of the ball robot was designed and manufactured. Through the driving control experiment applying the driving control system of the ball robot, it was confirmed that the ball robot was controlled within the error range of ±50.3mm in the x-axis direction and ±53.9mm in the y-axis direction without accumulating errors.