• 제목/요약/키워드: Motor Failure

검색결과 328건 처리시간 0.031초

Air-Barrier Width Prediction of Interior Permanent Magnet Motor for Electric Vehicle Considering Fatigue Failure by Centrifugal Force

  • Kim, Sung-Jin;Jung, Sang-Yong;Kim, Yong-Jae
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.952-957
    • /
    • 2015
  • Recently, the interior permanent magnet (IPM) motors for electric vehicle (EV) traction motor are being extensively researched because of its high energy density and high efficiency. The traction motor for EV requires high power and high efficiency at the wide driving region. Therefore, it is essential to fully consider the characteristics of the motor from low speed to high-speed driving regions. Especially, when the motor is driven at high speed, a significant centrifugal force is applied to the rotor. Thus, the rotor must be stably structured and be fully endured at the critical speed. In this paper, aims to examine the characteristics of the IPM motor by adjusting the width of air-barrier according to the permanent magnet position which is critical in designing an IPM motor for EV traction motors and to conduct a centrifugal force analysis for grasping mechanical safety.

34kW급 LNG Spray펌프용 극저온 유도전동기 설계에 관한 연구 (A Study on the Design of 34kW Cryogenic Induction Motor for LNG Spray Pump)

  • 정동욱;이기욱;류재호;박관수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.918-919
    • /
    • 2015
  • Because of environmental regulations in emissions control area, the demand for ships to use LNG as fuel is increasing. Orders for domestic shipbuilders to produce LNG carriers are steadily increasing. However, major appliances such as spray pump, main cargo pump and others have been relied on imports. Therefore, development of pump motor using at cryogenic temperature is necessary. Operating temperature of an induction motor is at $-163^{\circ}C$. At this low temperature, the resistivity of a motor coil is quite different from normal ones, and so does the torque characteristics of motor. This paper presents a designing method of a cryogenic induction motor for LNG pump. The variation of resistivity of motor coil is considered in the design process. The heat source such as core-loss, hysteresis-loss and copper-loss are analyzed to prevent the LNG evaporation which may cause the motor failure.

  • PDF

전류신호를 이용한 유도전동기의 회전자봉 결함검출에 관한 연구 (A Study on Detection of Broken Rotor Bars in Induction Motors Using Current Signature Analysis)

  • 신대철;정병훈
    • 한국소음진동공학회논문집
    • /
    • 제12권4호
    • /
    • pp.287-293
    • /
    • 2002
  • The unexpected failure of the induction motor makes the downtime of production, and the cost of the process cessation enormous. To reduce the downtime and increase the reliability of the motor, the vibration measurements for the fault detection have been used previously. Recently motor current signature analysis(MCSA) has been adapted for the fault detection and diagnosis of the motors. MCSA provides a powerful analysis tool for detecting the presence of mechanical and electrical faults in both the motor and driven equipment. In this paper, the fault severity of the rotor bar has been derived in terms of the resistance change which is calculated from the equivalent circuit model. Results show that the fault of the rotor can be easily detected and the measured value of the resistance change is verified by the detected fault from on-site tests using MCSA for the induction motors in an iron foundry.

세척과 절연보강에 따른 고압전동기 고정자 권선의 절연상태 분석 (Analysis of Insulation Condition in High Voltage Motor Stator Windings Following Cleaning and Insulation Reinforcement)

  • 김희동
    • 한국전기전자재료학회논문지
    • /
    • 제25권6호
    • /
    • pp.474-480
    • /
    • 2012
  • Diagnostic tests were performed on two high voltage(HV) motor stator windings. These tests included the measurement of insulation resistance, polarization index, AC current, dissipation factor($tan{\delta}$) and partial discharge(PD) magnitude. Surface contamination of HV motor stator windings has an effect on the AC current and $tan{\delta}$. When the stator windings were finished cleaning and insulation reinforcement, the increase rate of AC current(${\Delta}I$) and dissipation factor(${\Delta}tan{\delta}$) were very small compared to those before cleaning. However, the PD magnitude remained the same. These tests show that cleaning and insulation reinforcement of HV motor stator windings can reduce the insulation failure.

전압형 인버터의 출력전압 상승률 억제를 위한 출력 필터의 설계 (Output Filter Design for Suppression of High Voltage Gradient in the Voltage-Fed PWM Inverter)

  • 김성준;설승기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.296-298
    • /
    • 1995
  • This paper proposes a new filter topology that suppresses the high voltage gradient(dv/dt) in ac motor terminals. The high voltage gradient(dv/dt) causes over voltages on the motor windings, the degradation or motor insulation, and the bearing failure. Moreover surge voltage with high voltage gradient(dv/dt) in the PWM inverter red drive system where long line cables are required causes more serious problem to the motor. Thus, the most advisable method is attaching output filter to the inverter output terminals. The conventional output filters have several problems such as bulky size, difficulty or parameter tuning. The proposed filter can be relatively smaller than the conventional filters. By the proposed filter, the shaping or PWM waveform can considerably suppress high dv/dt in motor feeding cable from the inverter. The effectiveness or the proposed filter is compared with that or the conventional one and is verified by the computer simulation.

  • PDF

6 시그마 프로세스를 이용한 소형 직류 모터의 소음 절감 (Noise Reduction of a Small D/C Motor using 6 Sigma Process)

  • 차원준;최연선
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.509-514
    • /
    • 2002
  • This paper studies on the noise reduction for a small automobile DC Motor (a window motor) using the 6 sigma process. The application of 6 sigma process suggested reliable and valuable statistical data for the quality of the DC motor at the production line. In the measurement step in 6 sigma process, the FMEA(Failure Mode Effect Analysis) were used for the detection of noise sources. The application of 6 sigma process gave not only the improving method for the quality of the DC motor but also the confidence of improvement itself since it was done on the basis of the test results for a number of DC motors at the production line. Consequently the 6 sigma process was proved very effective for the noise reduction at the production line.

  • PDF

전류신호 분석을 통한 유도전동기 고장진단시스템 연구 (A study on the fault diagnosis system for Induction motor using current signal analysis)

  • 변윤섭;장동욱;박현준;왕종배;이병송
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.19-21
    • /
    • 2001
  • Induction motors are a critical component of many industrial machines and are frequently integrated in commercial equipment. The many economical losses and the deterioration of system reliability might be caused by the failure of induction motors in industrial field. Based on the reliability and cost competitiveness of driving system(motors), the faults detection and diagnosis of system is considered very important factors. In order to perform the faults detection and diagnosis of motors, the vibration monitoring method and motor current signature analysis (MCSA) method are emphasized. In this paper, MCSA method is used for induction motor fault diagnosis. This method analyzes the motor's supply current, since this diagnoses the motor's condition. The diagnostic system is constructed by using LabVIEW of National Instruments.

  • PDF

인버터 전원에 의한 견인전동기 고정자 코일의 절연특성 변화 (Change of Insulation Properties of Stator Coil fed by Inverter Source on Traction Motor)

  • 장동욱;박현준;이길헌;최종선;김정수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.420-422
    • /
    • 2003
  • Aging and failure of motor insulation depend on the stresses imposed on it. The insulation life time depends on the severity of the stresses. The electrical aging by transient surge is very important to traction motor in EMU(electric multiple unit). This paper Presents the insulation characteristics of stator coil by transient surge from inverter. There are several nondestructive tests available for checking the condition of motor insulation, the probable extent of aging,. and the rate of which aging is taking pace. So the insulation characteristics of stator coil were each analyzed by measurement of leakage current, dielectric loss($tan{\delta}$), capacitance, polarization index(PI) and partial discharge. The method of diagnosis is able to analyze the aging condition and Predict the life of the traction motor in EMU.

  • PDF

견인전동기 고정자 코일의 전기적 열화특성 (Properties of Electrical Performance on Stator Coil of Traction Motor by Accelerated Test)

  • 박현준;장동욱;김길동
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2003년도 추계학술대회 논문집(III)
    • /
    • pp.623-627
    • /
    • 2003
  • Aging and failure of motor insulation depend on the stresses imposed on it. The insulation life time depends on the severity of the stresses. The electrical aging by transient surge is very important to traction motor in EMU(electric multiple unit). This paper presents the insulation characteristics of stator coil by transient surge from inverter. There are several nondestructive tests available for checking the condition of motor insulation, the probable extent of aging, and the rate of which aging is taking place. So the insulation characteristics of stator coil were each analyzed by measurement of leakage current, dielectric loss($tan{\delta}$), capacitance, polarization index(PI) and partial discharge. The method of diagnosis is able to analyze the aging condition and predict the life of the traction motor in EMU.

  • PDF

유도전동기 고장진단시스템 연구 (A study on the fault diagnosis system for Induction motor)

  • 변윤섭;박현준;김길동;한영재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 D
    • /
    • pp.2172-2174
    • /
    • 2001
  • Induction motors are a critical component of many industrial machines and are frequently integrated in commercial equipment. The many economical losses and the deterioration of system reliability might be caused by the failure of induction motors in industrial field. Based on the reliability and cost competitiveness of driving system (motors), the faults detection and diagnosis of system is considered very important factors. In order to perform the faults detection and diagnosis of motors, the vibration monitoring method and motor current signature analysis (MCSA) method are emphasized. In this paper, MCSA method is used for induction motor fault diagnosis. This method analyzes the motor's supply current, since this diagnoses the motor's condition. The diagnostic system is constructed by using LabVIEW of National Instruments.

  • PDF