• 제목/요약/키워드: Motor Cooling System

검색결과 179건 처리시간 0.028초

하이브리드 차량을 위한 하이브리드 전동식 압축기 모터 드라이브 시스템 개발 (Motor Drive System Development of Hybrid Electric Air-con Compressor for HEV)

  • 정태욱;박성준;김성일;홍정표;윤철호;차현록;김형모
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1075-1076
    • /
    • 2007
  • The HEV (Hybrid Electrical Vehicle) becomes commercialized recently because of high fuel efficiency and low air pollution. The highest output power system except the traction motor is an air conditioner compressor in HEV system. The full or hybrid electric compressor is applied for HEV. The general HEC (Hybrid Electric Compressor) requires the half power motor and drive system of the full electric compressor because the rated output power of motor drive system is designed to charge the minimum cooling capacity at the time of idle stop. Therefore, this hybrid electric is more economical and practical solution. In this paper, we studied about the motor drive system of hybrid electric compressor for HEV. The applied voltage specification is 42 V, an IPMSM (Interior Permanent Magnet Synchronous Motor) is designed and applied as the compressor drive motor.

  • PDF

INVERTER를 응용한 MOTOR 냉각 제어시스템의 전력절감에 관한 연구 (A Study on Energy Saving of the Motor Cooling System with an Inverter)

  • 김기홍;정지훈;권봉환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.611-613
    • /
    • 2004
  • This paper is concerned with the simulation and determination of the input voltage and frequency for the optimal efficiency operation of induction motors. In general, induction motors have a specific character that operation efficiency is dropped sharply at the light roads condition. Consequently, if the induction motor is controlled by high efficiency using the VVVF(variable voltage variable frequency) control methods at optimal values, the entire system can obtain the substantial energy savings from the efficiency improvement in induction motors. In this paper, optimal slip is derived from the modeling of an induction motor and the optimal hybrid-control method is suggested by the simulation of the proposed algorithm for a 3-phase induction motor.

  • PDF

냉장형 모터와 리니어 모터를 적용한 초고속 수평형 머시닝센터의 구조 특성 해석 (Structural Characteristics Analysis of a High-Speed Horizontal Machining Center with Built-in Motor and Linear Motors)

  • 김석일;조재완
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2004년도 추계학술대회 논문집
    • /
    • pp.326-333
    • /
    • 2004
  • This paper presents the structural characteristics analysis of a high-speed horizontal machining center with spindle speed of 50, 000rpm and feedrate of 120m/min. The spindle system is designed based on the built-in motor, angular contact ceramic ball bearings, oil-air lubrication and oil-jacket cooling method. The X-axis and Y-axis feeding systems are composed of the linear motor and linear motion guides, and the Z-axis feeding system is composed of the servo-motor, ball screw and linear motion guide. The structural analysis model of the high-speed horizontal machining center is constructed by the finite element method, and the validity of structural design is estimated based on the structural deformation of the high-speed horizontal machining center and spindle nose caused by the gravity and inertia forces.

  • PDF

Conceptual design and fabrication test of the HTS magnets for a 500 W-class superconducting DC rotating machine under 77 K

  • Choi, J.;Kim, S.K.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제23권4호
    • /
    • pp.35-38
    • /
    • 2021
  • Conventional direct current (DC) rotating machines are usually used for crane and press machine using high torque in metal and steel industries, because of a constant output power along variable rotating speed. A general DC motor with permanent field magnets could not increase a magnetic flux density at a gap between armature coils and field magnets. However, a superconducting DC motor has field magnets composed with high temperature superconducting (HTS) coils and it could increase the magnetic flux density at the gap to over 10 times than those of a general DC motor by control the excitation current into HTS coils. The superconducting DC motor could be operated with extremely high torque and constant output power at a low rotational speed. In this paper, a 500 W superconducting DC rotating machine was conceptually designed with a LN2 (Liquid Nitrogen) cooling method and the operation characteristics results of HTS field magnets were presented. The two no-insulation HTS magnets for a 500 W superconducting DC rotating machine were fabricated. The excitation current for the HTS magnets could be controlled from 0 to 40 A. This test results will be available to design large-sized HTS magnets for a number of hundred kW class superconducting DC rotating machine under LN2 cooling system.

냉각팬 모터 제조공정의 품질개선에 관한 사례연구 (A Case Study of Quality Improvement practice in Cooling Fan Motor Manufacturing)

  • 정지용;배영주
    • 대한안전경영과학회지
    • /
    • 제15권4호
    • /
    • pp.279-288
    • /
    • 2013
  • The purpose of this study is to present a case study of six sigma quality improvement practice in cooling fan motor(CFM) manufacturing processes. In this study, the CFM manufacturing process of automobile parts not relevant to the target process rate of the process point of view, in order to reduce the system to solve the problem of localized resolution procedures of six sigma DMAIC methodology was applied to study. In conclusion, this study's field D in order to improve the initial rate of inadequate quality management best practices by applying the method of Six Sigma quality CFM failure through stabilization schemes were proposed cost reduction.To be CFM product to satisfy customers based on continuous monitoring of the effective field of claims quality management system is required.

섬유벨트 열재생 시스템을 부착한 공기 열원 열펌프의 난방 성능 특성 (Performance of Air Source Heat Pump with a Fiber Belt Heat Regeneration System)

  • 유영선;장진택;김영중;강금춘;윤진하;이건중
    • Journal of Biosystems Engineering
    • /
    • 제25권5호
    • /
    • pp.385-390
    • /
    • 2000
  • The heat pump is one of heating and cooling systems driven by electricity using natural energy as a heat source. The heat pump system was mainly adopted to a cooling system or a refrigeration system. In regions with a large amount of electricity, it is used as a heating system or a heating and cooling system of houses, buildings and agricultural facilities. During cold weather, air source heat pumps do not work well because of some technical problems, such as frosting on evaporator coil when outside air temperature is below -5$^{\circ}C$. In this research, the heat regenerative technology was employed to eliminate the frosting on evaporator coil and improve the COP of the heat pump system. This fiber belt heat regeneration system(FBHRS) has very simple structure consisting of a geared motor and a porous fiber belt passing through alternatively between cold and warm air duct. The laboratory test showed that the heat pump system with a FBHRS yielded an impressive COP higher than 3.5 at the outside air temperature of -7$^{\circ}C$ in heating mode.

  • PDF

자동차용 연료전지 냉각계통 열관리 동적 모사 (Dynamic Modeling of Cooling System Thermal Management for Automotive PEMFC Application)

  • 한재영;이강훈;유상석
    • 대한기계학회논문집B
    • /
    • 제36권12호
    • /
    • pp.1185-1192
    • /
    • 2012
  • 차량용 연료전지는 내연기관보다 운전 온도가 낮아 냉각수의 온도를 낮게 관리해야 하며, 이러한 냉각수 온도는 대기와의 온도차가 내연기관보다 작아 고성능 방열판 및 열관리계가 요구된다. 이러한 차량용 연료전지 열 관리계는 특히 연료전지 운전 온도 및 스택 내 온도분포를 결정하는 중요한 구성품이다. 본 연구에서는 차량용 연료전지 열 관리계 모델을 Matlab/$Simulink^{(R)}$ 환경 하에 개발하였으며, 기본 설계에 적용이 가능하도록 방열판 상세 모델을 개발하고 열 관리계는 팬, 모터, 방열판 그리고 냉각수 펌프로 구성하였다. 팬과 펌프는 경험식을 이용해 모델을 개발하였으며 모터 동특성을 고려하였다. 두 구성품은 연료전지의 입구와 출구 온도를 추출해 정해진 지령을 수령하도록 제어 하였다. 본 연구에는 연료전지 차량에 적합한 방열기 설계를 위해 방열기 특성을 확인하고, 이를 연료전지 시스템과 통합운전하면서, 연료전지 운전제어에 적절한 지 확인하였다.

Design and Experimental Investigation of High-Speed Three-Phase Induction Motor for Turbo Blower

  • Kim, Young-Kwan;Lee, Ju
    • 조명전기설비학회논문지
    • /
    • 제22권3호
    • /
    • pp.59-65
    • /
    • 2008
  • High-speed electrical motor has been studied for several applications, i.e. for direct-drive systems of centrifugal compressors and turbo blowers. This paper deals with a design consideration of electromagnetic, mechanical and thermal limits of high-speed induction motor for turbo blower. Basic design concept of high-speed motor was proposed. As the motor is to be operated at high speed, the losses are quite different from conventional low-speed machines. Especially, the increases of rotor eddy current and friction losses could lead to an overheated motor. So, we suggested a special cooling system to reduce temperature rise. And, based upon this design concept, the prototype induction motor(37[kW], 45,000[rpm]) for high-speed turbo blower was designed and 2-D electromagnetic field analysis was implemented. Finally, criteria to evaluate the characteristics of high-speed induction motor have been proposed and tested.

EV 상용차용 히트펌프 시스템 냉방 운전 특성에 관한 연구 (A Study on Performance Characteristics of Heat Pump System on Cooling Mode for Light-duty Commercial Electric Vehicles)

  • 전한별;김정일;원헌주;이호성
    • 한국산학기술학회논문지
    • /
    • 제20권12호
    • /
    • pp.69-75
    • /
    • 2019
  • 본 연구의 목적은 EV 경상용차에 적용되는 히트펌프 시스템에 대한 냉방 성능 특성을 실험적으로 분석하는 것이다. EV 경상용차가 운전되는 냉방 운전조건인 외기온도 35 ℃, 내기온도 25 ℃ 상황에서, 히트펌프 시스템의 냉방 특성을 분석하고자, 냉각수의 온도조건, 전동식 압축기 회전수 조건 변화에 대해서, 실험을 진행하였고, 그 결과를 분석하였다. 전동식 압축기 회전수가 증가할수록 냉방 성능이 평균 8.0 %가 증가하였고, 전동식 압축기 소비전력은 27 %가 증가하여서, 시스템 효율은 16.4 %가 감소하는 결과를 보여주고 있다. 전자장비 냉각을 위한 냉각수의 폐열을 활용하기 위하여서, 냉매랑 냉각수가 열교환 하는 칠러를 본 시스템에 적용하였다. 칠러에 적용되는 냉각수의 온도를 35 ℃에서 55℃로 변화시켰을 때, 응축 열원의 증가로 인하여서, 시스템 효율이 평균적으로 18.2 %가 떨어지는 결과를 보여주고 있다. 냉각수 유량 변화 측면에서, 운전 조건을 변화시켰지만, 냉방 성능에는 큰 변화를 보이고 있지 않았다. 향후, 냉각수 폐열을 사용하여서, 히트펌프 시스템에 대한 난방 성능 향상을 위한 연구가 필요한 상황에서, 관련 연구에 추가 할 예정이다.

Measurement System of Photosynthetic Photon Flux Distribution and Illumination Efficiency of LED Lamps for Plant Growth

  • Lee, Jae Su;Kim, Yong Hyeon
    • Journal of Biosystems Engineering
    • /
    • 제37권5호
    • /
    • pp.314-318
    • /
    • 2012
  • Purpose: This study was conducted to develop a measurement system for determining photosynthetic photon flux (PPF) distribution and illumination efficiency of LED lamps. Methods: The system was composed of a linear moving sensor part (LMSP), a rotating part to turn the LMSP, a body assembly to support the rotating part, and a motor controller. The average PPF of the LED lamp with natural cooling and water cooling was evaluated using the measurement system. Results: The PPF of LED lamp with water cooling was 3.1-31.7% greater than that with natural cooling. Based on the measured value, PPF on the horizontal surface was predicted. Illumination efficiency of the LED lamp was slightly increased with water cooling by 3.4%, compared with natural cooling. A simulation program using MATLAB was developed to analyze the effects of the vertical distance from lighting sources to growing bed, lamp spacing, and number of LED lamps, on the PPF distribution on the horizontal surface. The uniformity of the PPF distribution of the LED lamps was fairly improved with 15 cm spacing, as compared to the 5 cm spacing. By simulation, PPF of $217.0{\pm}27.9{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ was obtained at the vertical distance of 40 cm from six LED lamps with 12 cm spacing. This simulated PPF was compared to the measured one of $225.9{\pm}25.6{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$. After continuous lighting of 346 days, the relative PPF of LED lamps with water cooling and natural cooling was decreased by 6.6% and 22.8%, respectively. Conclusions: From these results, it was concluded that the measurement system developed in this study was useful for determining PPF and illumination efficiency of artificial lighting sources including LED lamp.