• 제목/요약/키워드: Motor Control

검색결과 7,259건 처리시간 0.036초

전침자극과 운동치료가 허혈성 뇌졸중 백서모델의 골격근에 미치는 영향 (Effects of Electroacupuncture and Therapeutic Exercise on Skeletal Muscle in the Ischemic Stoke Rats)

  • 유영대;김사열;민순규
    • The Journal of Korean Physical Therapy
    • /
    • 제18권3호
    • /
    • pp.9-21
    • /
    • 2006
  • Purpose: This study was intended to examine the effects of electroacupuncture and therapeutic exercise on muscle atrophy and exercise function in an ischemic stroke model induced by middle cerebral artery occlusion. Methods: This study selected 120 Sprangue-Dawley rats, 8-week of age, divided them into six groups, and assigned 5 rats to each group. Experiments were conducted for 1, 3 days, 1, and 8 weeks, respectively. Group I was a group of electroacupuncture and therapeutic exercise after inducing ischemic stroke; Group II was a group of therapeutic exercise after inducing ischemic stroke; Group III was a group of electroacupuncture after inducing ischemic stroke; Group IV was a sham group of electroacupuncture after inducing ischemic stroke; Group V was a control group and Group VI was a sham group without ischemic stroke. In each group, changes in weight of muscle and relative muscle of TA muscle, neurologic motor behavior test, histologic observations were observed and analyzed. Results: For the changes in muscle weight of unaffected and affected sides of TA muscle, muscle atrophy was seen in an affected side 3 days after ischemic stroke was induced. There was statistically significant difference in Group I 1 week and 8 weeks after ischemic stroke was induced, compared to Group V (p<0.05). For the changes in relative muscle weight of unaffected and affected sides of tibial anterior muscle, there was significant decrease in each group 3 days after ischemic stroke was induced, compared to Group IV, while there was statistically significant increase in Group I 1 week after ischemic stroke was induced, compared to Group V (p<0.05). For neuologic exercise behavior test, Group I generally had the highest score, compared to other groups. Conclusion: electroacupuncture and therapeutic exercise may improve muscle atrophy and change in histologic observations expression of ischemic stroke rats and contribute to the improvement of exercise function.

  • PDF

한글화된 균형 평가도구들의 신뢰도와 타당도 분석 (The Analysis on the Reliability and Validity of Korean-Version Balance Assessment Tools)

  • 장호영;이정훈;이석민
    • 대한물리의학회지
    • /
    • 제12권4호
    • /
    • pp.139-146
    • /
    • 2017
  • PURPOSE: The purpose of this study was to systematically analyze the reliability and validity of the Korean-version of the balance assessment tools. METHODS: Two reviewers of this study independently evaluated the titles of articles and abstracts of studies published until December 2016 through electronic databases (RISS, NDSL, KISS, DBpia) using the keywords "Balance or posture or postural control or postural stability", "Test or assessment or measurement or outcome measure or assessment tool or measurement tool", "Korean version", "Reliability" and "Validity". Regarding the questions considered suitable for the purpose of this study, consensus was reached after reading the full text. Selecting journals suitable for the purpose of the study, they were analyzed as data. RESULTS: The reviewers selected nine papers suitable for the purpose of this study, and Korean-version of the balance assessment tools, included the Berg Balance Scale (BBS), Activities-specific Balance Confidence (ABC) scale, Postural Assessment Scale for Stroke (PASS), Motor Assessment Scale (MAS), Trunk Impairment Scale (TIS), Falls Efficacy Scale (FES), Tinetti-Balance scale, Fullerton Advanced Balance (FAB) scale, and Function In Sitting Test (FIST). Our study showed that the reliability and validity of the Korean-version of the balance assessment tools were high. CONCLUSION: The Korean-version of the balance assessment tools with high reliability and validity would enable physical therapists to make a more accurate evaluation of balance.

25BAR급 바이오가스 고압 압축공급시스템 상세설계 (Detailed Design for 25bar-class Biogas Compression Supplying System)

  • 허광범;박정극;윤은영;이정빈
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.173.1-173.1
    • /
    • 2011
  • The high fuel flexibility of gas turbine power system has boosted their use in a wide variety of applications. Recently, the demand for biogas generated from the digestion of organic wastes and sewage waste water as a fuel for gas turbines has increased. We investigated the performance of high pressure biogas compression system and operating conditions for supplying biogas. The total flow per minute of biogas from food waste water digestion tank is $54Nm^3$. The main type of biogas compression system is the reciprocating system and screw type system. The target of biogas mechanical data is the as belows; inlet pressure 0.045bar, supplying biogas temperature is $30{\sim}60^{\circ}C$, and final pressure is above the 25 bar. Also, inlet conditions of biogas consist of CH4 48.5%~83%, $H_2S$ Max. 500ppm, $NH_3$ Max. 1,500ppm and Siloxane 2.7~4.6ppm. The boosting Blower system raises a pressure from 0.045bar to 1bar before main compressor. The main system lay out of reciprocating consisits of compressor driver, filter, cooling system, blowdown vessel, control system and ESD(Emergency Shut Down) system. And an enclosure package needs to be installed for reducing noise up to 75dB. The system driver is the electronic motor of explosion proof type. Forthe compressor system reliable operation, the cleaning system something like particulate filter needs to be set up in the inlet of compressor and Coalescing Filter in the outlet of compressor. Particulate Filter has to be removed above $10{\mu}m$ size of the particles in biogas. The coalescing filter(Micofine Borosilicate Glass Fibers Filter treated phenol acid) also removes moisture and oil of above $0.3{\mu}m$ to be involved in high pressure biogas up to 90%~98%.

  • PDF

A/T차량의 저속 영역에서 댐퍼클러치 작동에 따른 이상 진동 해석 (Analysis of Abnormal Vibration by a Damper Clutch Operation in Low Speed Ranges of A/T Vehicles)

  • 신창우;김범수;이대흥;정종렬;임원식;차석원
    • 한국자동차공학회논문집
    • /
    • 제21권3호
    • /
    • pp.157-164
    • /
    • 2013
  • A damper clutch in automatic transmission systems has some advantages of fuel economy and dynamic performance. Although a damper clutch operation improves a fuel economy of the vehicles, a positive operation of a damper clutch in a low vehicle speed induces abnormal vibration. This paper analyzed one of reasons for abnormal vibration by a damper clutch operation in low engine speed ranges. A simulation model was designed to confirm the effects of a damper clutch operation under unstable regions of an engine. A theoretical analysis was carried out about an engine operation stability. Simulation was conducted to depict abnormal vibration by a damper clutch operation in unstable regions of an engine performance curve. The effects of an engine operation region for abnormal vibration by a damper clutch was investigated according to the range and the slope of unstable regions. As a result of simulations, a damper clutch operation would be better to avoid an engine unstable regions.

LabVIEW 적용 임베디드 태양추적장치 개발 (Development of an Embedded Solar Tracker using LabVIEW)

  • 오승진;이윤준;김남진;오원종;천원기
    • 에너지공학
    • /
    • 제19권2호
    • /
    • pp.128-135
    • /
    • 2010
  • 본 연구에서는 LabVIEW를 활용한 임베디드 태양추적장치가 개발되었다. 이 시스템은 LabVIEW로 작성된 소프트웨어, CompactRIO, C-계열의 모션 인터페이스 모듈, 아날로그 수집 모듈(DAQ:Data Acquisition), 스텝 드라이브, 스텝 모터, 피드백디바이스 그리고 기타 부품들로 구성되어져 있다. CompactRIO는 내부에 리얼타임 프로세서를 내장하고 있으며 이는 태양추적장치가 외부 제어없이도 자동으로 작동이 가능하게 한다. 태양 추적장치의 정확도를 높이기 위하여 천문학적인 방법과 광학적인 방법을 통합하여 개발하였다. 광학적인 방법에서는 피드백디바이스가 사용되었는데 4개의 CdS를 사용하여 지속적으로 피드백 신호를 컨트롤러로 공급하여 문제 발생시에도 태양을 지속적으로 추적한다. 태양의 고도 및 방위각의 데이터베이스는 미국의 Naval Observatory의 데이터와 비교하였다.

Dopamine Modulates Corticostriatal Synaptic Transmission through Both $D_1$ and $D_2$ Receptor Subtypes in Rat Brain

  • Lee, Hyun-Ho;Choi, Se-Joon;Kim, Ki-Jung;Cho, Hyeong-Seok;Kim, Seong-Yun;Sung, Ki-Wug
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제9권5호
    • /
    • pp.263-268
    • /
    • 2005
  • Striatum has important roles in motor control, habitual learning and memory. It receives glutamatergic inputs from neocortex and thalamus, and dopaminergic inputs from substantia nigra. We examined effects of dopamine (DA) on the corticostriatal synaptic transmission using in vitro extracellular recording technique in rat brain corticostriatal slices. Synaptic responses were elicited by stimulation of cortical glutamatergic inputs on the corpus callosum and recorded in the dorsal striatum. Corticostriatal population spike (PS) amplitudes were decreased ($39.4{\pm}7.9$%) by the application of $100{\mu}M$ DA. We applied receptor subtype specific agonists and antagonists and characterized the modulation of corticostriatal synaptic transmission by different DA receptor subtypes. $D_2$ receptor agonist (quinpirole), antagonist (sulpiride), and $D_1$ receptor antagonist (SKF 83566), but not $D_1$ receptor agonist (SKF 38393), induced significantly the reduction of striatal PS. Pretreatment neither with SKF 83566 nor sulpiride significantly affected corticostriatal synaptic inhibition by DA. However, the inhibition of DA was completely blocked by pretreatment with mixed solution of both SKF 83566 and sulpiride. These results suggest that DA inhibits corticostriatal synaptic transmission through both $D_1$ and $D_2$ receptors in concert with each other.

ZigBee를 이용한 뇌졸중 치료용 무선 전기 자극기 개발 (Development of Wireless Neuro-Modulation System for Stroke Recovery Using ZigBee Technology)

  • 김국화;유문호;신용일;김형일;김남균;양윤석
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권1호
    • /
    • pp.153-161
    • /
    • 2007
  • Stroke is the second most significant disease leading to death in Korea. The conventional therapeutic approach is mainly based on physical training, however, it usually provides the limited degree of recovery of the normal brain function. The electric stimulation therapy is a novel and candidate approach with high potential for stroke recovery. The feasibility was validated by preliminary rat experiments in which the motor function was recovered up to 80% of the normal performance level. It is thought to improve the neural plasticity of the nerve tissues around the diseased area in the stroked brain. However, there are not so much research achievements in the electric stimulation for stroke recovery as for the Parkinson's disease or Epilepsy. This study aims at the developments of a wireless variable pulse generator using ZigBee communication for future implantation into human brain. ZigBee is widely used in wireless personal area network (WPAN) and home network applications due to its low power consumption and simplicity. The developed wireless pulse generator controlled by ZigBee can generate various electric stimulations without any distortion. The electric stimulation includes monophasic and biphasic pulse with the variation of shape parameters, which can affect the level of recovery. The developed system can be used for the telerehabilitation of stroke patient by remote control of brain stimulation via ZigBee and internet. Furthermore, the ZigBee connection used in this study provides the potential neural signal transmission method for the Brain-Machine Interface (BMI).

A Study on the Noise Reduction of Reciprocating Type Air Compressors

  • Lee Kwang-Kil;Kim Kwang-Jong;Lee Gwan-Hyung;Park Jae-Suk;Son Doo-ik;Kim Bong-Ki;Lee Dong-Ju
    • International Journal of Safety
    • /
    • 제3권1호
    • /
    • pp.6-9
    • /
    • 2004
  • This paper deals with the noise evaluation technique of a reciprocating air-compressor and its noise reduction. The reciprocating air-compressors are widely used in the small, medium sized industrial firms, and lots of their employees are affected and irritated by their noise in the workplace. Thus, noise control actions should be taken appropriately by considering the hearing loss due to the occupational noise exposure. Lead-wrapping techniques are employed to identify the contribution of principal noise sources which are generally known as motor, belts, suction/discharge valves, moving pistons, and flow-induced noise caused by edges or discontinuities along the flow path e.g. expansions, contractions, junctions and bends etc .. As a result, main noise sources of the air-compressor can be categorized by the suction/discharge noise, valve noise, and compressed-air tank noise. Based on the investigations, mufflers are designed to reduce both the suction/discharge noise and the compressed-air tank noise. Instead of the conventional valve plate, polyethylene resin is used as a new one for the reduction of valve impact noise. In addition, attempts are made to reduce the valve noise propagation to the cylinder head and the compressor tank by using the insulation casings. As a result of the countermeasure plans, it can be achieved that the noise reduction of the air-compress is up to 10dB.

척수강 내로 투여한 Epigallocatechin Gallate이 모르핀의 항침해 작용에 대한 내성 발생에 미치는 효과 (The Effect of Intrathecal Epigallocatechin Gallate on the Development of Antinociceptive Tolerance to Morphine)

  • 김웅모;배홍범;최정일
    • The Korean Journal of Pain
    • /
    • 제22권3호
    • /
    • pp.199-205
    • /
    • 2009
  • Background: A major ingredient of green tea is epigallocatechin-3-gallate (EGCG), and this is known to have many beneficial effects for cancer prevention and also on the cardiovascular system and neurodegenerative diseases through its anti-oxidant, anti-angiogenic, anti-inflammatory, lipid-lowering and neuroprotective properties. Its actions on nociception and the spinal nervous system have been examined in only a few studies, and in these studies EGCG showed an antinociceptive effect on inflammatory and neuropathic pain, and a neuroprotective effect in motor neuron disease. This study was performed to investigate the effect of EGCG on acute thermal pain and the development of morphine tolerance at the spinal level. Methods: The experimental subjects were male Sprague-Dawley rats and the Hot-Box test was employed. A single or double-lumen intrathecal catheter was implanted at the lumbar enlargement for drug administration. An osmotic pump was used to infuse morphine for 7 days for induction of morphine tolerance. EGCG was injected repeatedly for 7 days at twice a day through the intrathecal catheter. Results: Intrathecal EGCG increased the paw withdrawal latency (PWL) after repeated administration for 7 days at twice a day, but this did not happen with administering on single bolus injection of EGCG. In addition, the antinociceptive effect of intrathecal morphine was not affected by co-administration with EGCG. A continuous 7-day infusion of morphine caused a significant decrease of the PWL in the control group (M + S, morphine plus saline). In contrast, intrathecal EGCG injection over 7 days blocked the decrease of the PWL in the experiment group (M + E, morphine plus EGCG). Conclusions: Intrathecal ECGC produced a weak antinociceptive effect for acute thermal pain, but it did not change the morphine's analgesic effect. However, the development of antinociceptive tolerance to morphine was attenuated by administering intrathecal EGCG.

냉매 내 공기혼입에 따른 에어컨 시스템의 냉각성능 저하 (Cooling Performance Deficiency of Air Conditioning System According to Air Quantity Included in Refrigerant)

  • 문성원;민영봉;정태상
    • Journal of Biosystems Engineering
    • /
    • 제34권6호
    • /
    • pp.470-475
    • /
    • 2009
  • This study was performed to present the diagnosis basis of cooling performance deficiency according to air quantity included in refrigerant of air-conditioner by detecting the temperatures and pressures of refrigerant pipeline. The car air-conditioner of SONATA III (Hyundai motor Co., Korea) was tested by maximum cooling condition at 1500 rpm of engine speed in the room with controlled air condition at $33\sim35^{\circ}C$ and 55~57% RH. Measured variables were temperature differences between inlet and outlet pipe surface of the compressor (Tcom), condenser (Tcon), receive dryer (Trec) and evaporator (Teva), and high pressure (HP) and low pressure (LP) in the refrigerant pipeline, and temperature difference (Tcoo) between inlet and outlet air of the cooling vent of evaporator. Control variables were the refrigerant charging weight and the vacuum degree in the refrigerant pipeline before charging refrigerant. From the test, it was represented that the measuring values of (Tcom), LP and (Tcoo) were enabled to make the diagnosis of cooling performance deficiency according to quantity included in refrigerant of air-conditioner. The ranges of Tcom, LP and Tcoo to make the diagnosis of cooling performance deficiency were respectively less than $55^{\circ}C$, more than 166.7 kPa-g(1.7 kgf/$cm^2$) and less than $13.7^{\circ}C$. In the case of using only external sensors and the condition under the normal performances of air conditioner, it was considered that the ranges of LP and Tcoo to make the diagnosis of cooling performance deficiency were respectively more than 166.7 Pa and less than $12^{\circ}C$.