• Title/Summary/Keyword: Motion-based

Search Result 6,996, Processing Time 0.04 seconds

Simulation analysis and evaluation of decontamination effect of different abrasive jet process parameters on radioactively contaminated metal

  • Lin Zhong;Jian Deng;Zhe-wen Zuo;Can-yu Huang;Bo Chen;Lin Lei;Ze-yong Lei;Jie-heng Lei;Mu Zhao;Yun-fei Hua
    • Nuclear Engineering and Technology
    • /
    • v.55 no.11
    • /
    • pp.3940-3955
    • /
    • 2023
  • A new method of numerical simulating prediction and decontamination effect evaluation for abrasive jet decontamination to radioactively contaminated metal is proposed. Based on the Computational Fluid Dynamics and Discrete Element Model (CFD-DEM) coupled simulation model, the motion patterns and distribution of abrasives can be predicted, and the decontamination effect can be evaluated by image processing and recognition technology. The impact of three key parameters (impact distance, inlet pressure, abrasive mass flow rate) on the decontamination effect is revealed. Moreover, here are experiments of reliability verification to decontamination effect and numerical simulation methods that has been conducted. The results show that: 60Co and other homogeneous solid solution radioactive pollutants can be removed by abrasive jet, and the average removal rate of Co exceeds 80%. It is reliable for the proposed numerical simulation and evaluation method because of the well goodness of fit between predicted value and actual values: The predicted values and actual values of the abrasive distribution diameter are Ф57 and Ф55; the total coverage rate is 26.42% and 23.50%; the average impact velocity is 81.73 m/s and 78.00 m/s. Further analysis shows that the impact distance has a significant impact on the distribution of abrasive particles on the target surface, the coverage rate of the core area increases at first, and then decreases with the increase of the impact distance of the nozzle, which reach a maximum of 14.44% at 300 mm. It is recommended to set the impact distance around 300 mm, because at this time the core area coverage of the abrasive is the largest and the impact velocity is stable at the highest speed of 81.94 m/s. The impact of the nozzle inlet pressure on the decontamination effect mainly affects the impact kinetic energy of the abrasive and has little impact on the distribution. The greater the inlet pressure, the greater the impact kinetic energy, and the stronger the decontamination ability of the abrasive. But in return, the energy consumption is higher, too. For the decontamination of radioactively contaminated metals, it is recommended to set the inlet pressure of the nozzle at around 0.6 MPa. Because most of the Co elements can be removed under this pressure. Increasing the mass and flow of abrasives appropriately can enhance the decontamination effectiveness. The total mass of abrasives per unit decontamination area is suggested to be 50 g because the core area coverage rate of the abrasive is relatively large under this condition; and the nozzle wear extent is acceptable.

Wishbowl: Production Case Study of Music Video and Immersive Interactive Concert of Virtual Band Idol Verse'day (Wishbowl: 버추얼 밴드 아이돌 Verse'day 뮤직비디오 및 몰입형 인터랙티브 공연 제작 사례 연구)

  • Sebin Lee;Gyeongjin Kim;Daye Kim;Jungjin Lee
    • Journal of the Korea Computer Graphics Society
    • /
    • v.30 no.3
    • /
    • pp.23-41
    • /
    • 2024
  • Recently, various virtual avatar music content that showcases singing and dancing have been produced, and as virtual artists gain popularity, offline virtual avatar concerts have also emerged. However, there are few examples of virtual avatar band content where avatars play instruments. In addition, offline virtual avatar concerts using large screens at the front are limited in their ability to utilize the fantastical effects and high degree of freedom unique to virtual reality. In this paper, inspired by these limitations of virtual avatar music content, we introduce the production case of virtual avatar band content and immersive interactive concert of virtual band idol Verse'day. Firstly, we present a case study on creating band performance animations and music videos using motion capture systems and real-time engines. Then, we introduce a production case of an immersive interactive concert using projection mapping technology and a light stick that allows real-time interaction in an offline concert. Finally, based on these production cases, we discussed the future research directions of developing virtual avatar music content creation. We expect that our production cases will inspire the creation of diverse virtual avatar music content and the development of immersive interactive offline virtual avatar concerts in the future.

Seismic Safety Evaluation of Korean R/C School Buildings Built in the 1980s (1980년대 국내 철근콘크리트 학교건물의 내진 안전성 평가에 관한 연구)

  • Lee, Kang-Seok;Wi, Jeong-Du;Kim, Yong-In;Lee, Hyun-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.5 s.57
    • /
    • pp.149-159
    • /
    • 2009
  • The main purpose of this study is to evaluate the seismic safety of Korean R/C school buildings built in the 1980s, based on "the Japanese Standard for Evaluation of Seismic Capacity of Existing R/C Buildings", the nonlinear static and the nonlinear dynamic analyses. The evaluation result of the Japanese Standard showed that R/C school buildings built in the 1980s have 0.2 through 0.4 of seismic indices($I_S$). This result indicates that more than medium damage could be potentially occurred under a medium intensity level of ground motion(150g). The results of the nonlinear analyses and the post-earthquake damage evaluation method showed that Korean R/C school buildings can be suffered moderate and severe damages under a 150gal and a 200gal intensity levels of ground motions, respectively. These results reveal that R/C school buildings should be urgently required a actual earthquake preparedness measures including seismic strengthening for future earthquake.

Evaluation for Surfriding/Broaching of the IMO Second Generation Intact Stability (IMO 2세대 비손상 복원성에 의한 서프라이딩/브로칭 평가)

  • Yong Duck Kang;Sangmok Lee;Daehyeon Kim;Byungyoung Moon
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.25 no.2
    • /
    • pp.86-93
    • /
    • 2024
  • This study evaluates the stability of a 4.99-ton small coastal fishing boat using data interpreted according to the second-generation intact stability criteria of the International Maritime Organization (IMO). The focus is on the ship's behavior under surfriding/broaching conditions during sea navigation, ensuring compliance with international standards. The data processing procedures presented apply stricter criteria than the first-generation intact stability standards to assess the ship's intact stability in waves. However, if the vessel deviates from its standard condition, a separate intact stability assessment based on actual loading conditions is necessary. The surfriding/broaching data processing procedures utilized a program developed by the Shipbuilding and Ocean Equipment Research Center at Kunsan National University. The results were analyzed and compared in detail according to the conditions, parameters, and criteria used for the calculations. Additionally, the study presents the results of Level 1 and Level 2 assessments according to IMO regulations, providing a parametric analysis of the small coastal fishing boat's stability. This allows for the evaluation of intact stability in hydrodynamic motion scenarios.tract.

Performance Evaluation of WWTP Based on Reliability Concept (신뢰성에 기초한 하수처리장 운전효율 평가)

  • Lee, Doo-Jin;Sun, Sang-Woon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.3
    • /
    • pp.348-356
    • /
    • 2007
  • Statistical and probabilistic method was used in the analysis of data, which is the most effective one in describing the various natures, and the methodology relating the results with the design was developed. Influents and effluents of three treatment plants were analyzed and the focus was made on BOD, COD, SS, IN, TP The fluctuations of influent such as BOD, COD, SS were extremely large and their standard deviations(st.dev) were more than 10 mg/L. but those of TN, TP were small; the st.dev was 6.6 mg/L for TN, 0.6 mg/L for TP, respectively. But, effluent concentration showed consistent pattern regardless of the influent fluctuations, the st.dev was ranged between 0.28 and 4.48 mg/L. Effluent distributional characteristics were as follows; BOD, COD were distributed normally, but SS, TN, and TP, log-normally; unsymmetric and skewed to the right. The coefficient of reliability(COR) based on the results of statistics of data was introduced to evaluate the process performance an4 to reflect the process performance to the process design. The coefficient of reliability relates the design value(the goal) with the standards and it can be used in operating treatment facilities under a certain reliability level and/or in evaluating the reliability of the treatment facilities on operation. Each treated water quality of effluent showed the half of water quality standards in the level of 50% percentile and all treatment plant was achieved 100% probability of water quality standards. It was concluded that the variability of the process performance should be reflected to the design procedure and the standards through the analysis based on the statistics and the probability.

Suggestion of Additional Criteria for Site Categorization in Korea by Quantifying Regional Specific Characteristics on Seismic Response (지역고유 지진응답 특성 정량화를 통한 국내 부지 분류 기준의 추가 반영 제안)

  • Sun, Chang-Guk
    • Geophysics and Geophysical Exploration
    • /
    • v.13 no.3
    • /
    • pp.203-218
    • /
    • 2010
  • The site categorization and corresponding site amplification factors in the current Korean seismic design guideline are based on provisions for the western United States (US), although the site effects resulting in the amplification of earthquake ground motions are directly dependent on the regional and local site characteristic conditions. In these seismic codes, two amplification factors called site coefficients, $F_a$ and $F_v$, for the short-period band and midperiod band, respectively, are listed according to a criterion, mean shear wave velocity ($V_S$) to a depth of 30 m, into five classes composed of A to E. To suggest a site classification system reflecting Korean site conditions, in this study, systematic site characterization was carried out at four regional areas, Gyeongju, Hongsung, Haemi and Sacheon, to obtain the $V_S$ profiles from surface to bedrock in field and the non-linear soil properties in laboratory. The soil deposits in Korea, which were shallower and stiffer than those in the western US, were examined, and thus the site period in Korea was distributed in the low and narrow band comparing with those in western US. Based on the geotechnical characteristic properties obtained in the field and laboratory, various site-specific seismic response analyses were conducted for total 75 sites by adopting both equivalent-linear and non-linear methods. The analysis results showed that the site coefficients specified in the current Korean provision underestimate the ground motion in the short-period range and overestimate in the mid-period range. These differences can be explained by the differences in the local site characteristics including the depth to bedrock between Korea and western US. Based on the analysis results in this study and the prior research results for the Korean peninsula, new site classification system was developed by introducing the site period as representative criterion and the mean $V_S$ to a depth of shallower than 30 m as additional criterion, to reliably determine the ground motions and the corresponding design spectra taking into account the regional site characteristics in Korea.

Dosimetric Evaluation of Amplitude-based Respiratory Gating for Delivery of Volumetric Modulated Arc Therapy (진폭 기반 호흡연동 체적변조회전방사선치료의 선량학적 평가)

  • Lee, Chang Yeol;Kim, Woo Chul;Kim, Hun Jeong;Park, Jeong Hoon;Min, Chul Kee;Shin, Dong Oh;Choi, Sang Hyoun;Park, Seungwoo;Huh, Hyun Do
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.127-136
    • /
    • 2015
  • The purpose of this study is to perform a dosimetric evaluation of amplitude-based respiratory gating for the delivery of volumetric modulated arc therapy (VMAT). We selected two types of breathing patterns, subjectively among patients with respiratory-gated treatment log files. For patients that showed consistent breathing patterns (CBP) relative to the 4D CT respiration patterns, the variability of the breath-holding position during treatment was observed within the thresholds. However, patients with inconsistent breathing patterns (IBP) show differences relative to those with CBP. The relative isodose distribution was evaluated using an EBT3 film by comparing gated delivery to static delivery, and an absolute dose measurement was performed with a $0.6cm^3$ Farmer-type ion chamber. The passing rate percentages under the 3%/3 mm gamma analysis for Patients 1, 2 and 3 were respectively 93.18%, 91.16%, and 95.46% for CBP, and 66.77%, 48.79%, and 40.36% for IBP. Under the more stringent criteria of 2%/2 mm, passing rates for Patients 1, 2 and 3 were respectively 73.05%, 67.14%, and 86.85% for CBP, and 46.53%, 32.73%, and 36.51% for IBP. The ion chamber measurements were within 3.5%, on average, of those calculated by the TPS and within 2.0%, on average, when compared to the static-point dose measurements for all cases of CBP. Inconsistent breathing patterns between 4D CT simulation and treatment may cause considerable dosimetric differences. Therefore, patient training is important to maintain consistent breathing amplitude during CT scan acquisition and treatment delivery.

Impact of Deep-Learning Based Reconstruction on Single-Breath-Hold, Single-Shot Fast Spin-Echo in MR Enterography for Crohn's Disease (크론병에서 자기공명영상 장운동기록의 단일호흡 단발 고속 스핀 에코기법: 딥러닝 기반 재구성의 영향)

  • Eun Joo Park;Yedaun Lee;Joonsung Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.6
    • /
    • pp.1309-1323
    • /
    • 2023
  • Purpose To assess the quality of four images obtained using single-breath-hold (SBH), single-shot fast spin-echo (SSFSE) and multiple-breath-hold (MBH) SSFSE with and without deep-learning based reconstruction (DLR) in patients with Crohn's disease. Materials and Methods This study included 61 patients who underwent MR enterography (MRE) for Crohn's disease. The following images were compared: SBH-SSFSE with (SBH-DLR) and without (SBH-conventional reconstruction [CR]) DLR and MBH-SSFSE with (MBH-DLR) and without (MBH-CR) DLR. Two radiologists independently reviewed the overall image quality, artifacts, sharpness, and motion-related signal loss using a 5-point scale. Three inflammatory parameters were evaluated in the ileum, the terminal ileum, and the colon. Moreover, the presence of a spatial misalignment was evaluated. Signal-to-noise ratio (SNR) was calculated at two locations for each sequence. Results DLR significantly improved the image quality, artifacts, and sharpness of the SBH images. No significant differences in scores between MBH-CR and SBH-DLR were detected. SBH-DLR had the highest SNR (p < 0.001). The inter-reader agreement for inflammatory parameters was good to excellent (κ = 0.76-0.95) and the inter-sequence agreement was nearly perfect (κ = 0.92-0.94). Misalignment artifacts were observed more frequently in the MBH images than in the SBH images (p < 0.001). Conclusion SBH-DLR demonstrated equivalent quality and performance compared to MBH-CR. Furthermore, it can be acquired in less than half the time, without multiple BHs and reduce slice misalignments.

Kinemetic analysis of a thumping security motion with an expandable barton (경호원의 삼단봉 머리치기 동작의 운동학적 분석)

  • Kim, Yong-Hak;Kim, Sin-Hye;Jung, Sung-Bae
    • Korean Security Journal
    • /
    • no.36
    • /
    • pp.93-109
    • /
    • 2013
  • This research is mainly based on the experimental result due to seek different outcomes whena certain security motion with a paticular gear is applied in a plausible confrontational situation. For the purpose of this research an Expandable Baton, which is one of the most commonsecurity equipments, was chosen to be applied in a situation of hitting a person's head. Alsothe results will be studied in the view of Kinematic theory. To demonstrate, 10 students who were majeored in Escort Crane studies at 'H' university werechosen as testees. The participants were grouped into two-one is practiced with the 'expanadable baton use program' and the other is pre-practiced. In this report two groups abovewill be reffered as 'group A' and 'group B' for conveniency. There were a number of differences and changes between two groups. Group B took more timethan the other group did. Group A spent about 0.428sec in section 'e2' and 0.230sec in section'e3' while Group B took 0.435sec, 0.232sec in each sections.To add on, more distinctive results were out when it was more focused on physical movements. Two gropus presented considerable changes- in an 'left-right' moving displacement-Group A;$2.16{\pm}0.9cm$ (left side), $3.78{\pm}1.42cm$ (right side), total $5.94{\pm}2.03cm$. Group B; $2.97{\pm}1.01cm$ (left side),$4.56{\pm}1.57cm$ (right side), total $7.53{\pm}2.13cm$.Continuously, different outcomeswere shown between two groups in a 'back and forth' moving displacement-Group A;$32.48{\pm}3.86cm$, $35.21{\pm}4.64cm$, total $69.36{\pm}5.72$. Group B; $34.50{\pm}6.12cm$, $37.04{\pm}3.70cm$, total $71.46{\pm}7.17cm$. Furthermore, changes in an 'up and down' moving displacement were - GroupA; $5.62{\pm}2.41cm$, $4.54{\pm}1.87cm$, total $10.11{\pm}1.57cm$. Group B; $6.33{\pm}1.78cm$, $4.86{\pm}1.85cm$,total $10.68{\pm}1.81cm$. To continue, there were few modifications of degree on participants' joints, espcially on 'Wristjoint', 'Elbow joint' and 'Shoulder joint', depend on different sections -Wrist joint;Group A; e1 $114.62{\pm}7.13$, e2 $68.27{\pm}6.37$, e3 $131.64{\pm}6.27$. Group B; e1 $112.62{\pm}6.13$, e2 $66.28{\pm}7.38$, e3$137.42{\pm}4.28$ and Elbow joint ; Group A e1 $132.31{\pm}6.55$, e2 $117.92{\pm}8.42$, e3 $144.41{\pm}6.32$. Group B; e1 $133.58{\pm}8.56$, e2 $114.45{\pm}8.21$, e3 $139.89{\pm}4.38$. Lastly, degree changes ofshoulder joint were; Group A; e1 $13.55{\pm}3.85$, e2 $131.42{\pm}11.24$, e3 $78.32{\pm}6.28$. Group B; e1$9.45{\pm}1.23$, e2 $136.74{\pm}13.21$, e3 $79.75{\pm}4.24$.

  • PDF

Dose verification for Gated Volumetric Modulated Arc Therapy according to Respiratory period (호흡연동 용적변조 회전방사선치료에서 호흡주기에 따른 선량전달 정확성 검증)

  • Jeon, Soo Dong;Bae, Sun Myung;Yoon, In Ha;Kang, Tae Young;Baek, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.137-147
    • /
    • 2014
  • Purpose : The purpose of this study is to verify the accuracy of dose delivery according to the patient's breathing cycle in Gated Volumetric Modulated Arc Therapy Materials and Methods : TrueBeam STxTM(Varian Medical System, Palo Alto, CA) was used in this experiment. The Computed tomography(CT) images that were acquired with RANDO Phantom(Alderson Research Laboratories Inc. Stamford. CT, USA), using Computerized treatment planning system(Eclipse 10.0, Varian, USA), were used to create VMAT plans using 10MV FFF with 1500 cGy/fx (case 1, 2, 3) and 220 cGy/fx(case 4, 5, 6) of doserate of 1200 MU/min. The regular respiratory period of 1.5, 2.5, 3.5 and 4.5 sec and the patients respiratory period of 2.2 and 3.5 sec were reproduced with the $QUASAR^{TM}$ Respiratory Motion Phantom(Modus Medical Devices Inc), and it was set up to deliver radiation at the phase mode between the ranges of 30 to 70%. The results were measured at respective respiratory conditions by a 2-Dimensional ion chamber array detector(I'mRT Matrixx, IBA Dosimetry, Germany) and a MultiCube Phantom(IBA Dosimetry, Germany), and the Gamma pass rate(3 mm, 3%) were compared by the IMRT analysis program(OmniPro I'mRT system software Version 1.7b, IBA Dosimetry, Germany) Results : The gamma pass rates of Case 1, 2, 3, 4, 5 and 6 were the results of 100.0, 97.6, 98.1, 96.3, 93.0, 94.8% at a regular respiratory period of 1.5 sec and 98.8, 99.5, 97.5, 99.5, 98.3, 99.6% at 2.5 sec, 99.6, 96.6, 97.5, 99.2, 97.8, 99.1% at 3.5 sec and 99.4, 96.3, 97.2, 99.0, 98.0, 99.3% at 4.5 sec, respectively. When a patient's respiration was reproduced, 97.7, 95.4, 96.2, 98.9, 96.2, 98.4% at average respiratory period of 2.2 sec, and 97.3, 97.5, 96.8, 100.0, 99.3, 99.8% at 3.5 sec, respectively. Conclusion : The experiment showed clinically reliable results of a Gamma pass rate of 95% or more when 2.5 sec or more of a regular breathing period and the patient's breathing were reproduced. While it showed the results of 93.0% and 94.8% at a regular breathing period of 1.5 sec of Case 5 and 6, it could be confirmed that the accurate dose delivery could be possible on the most respiratory conditions because based on the results of 100 patients's respiratory period analysis as no one sustained a respiration of 1.5 sec. But, pretreatment dose verification should be precede because we can't exclude the possibility of error occurrence due to extremely short respiratory period, also a training at the simulation and careful monitoring are necessary for a patient to maintain stable breathing. Consequently, more reliable and accurate treatments can be administered.