• Title/Summary/Keyword: Motion of the Moon

Search Result 850, Processing Time 0.033 seconds

Analysis of the Dose Distribution of Moving Organ using a Moving Phantom System (구동팬텀 시스템에 의한 움직이는 장기의 선량분포 분석)

  • Kim, Yon-Lae;Park, Byung-Moon;Bae, Yong-Ki;Kang, Min-Young;Lee, Gui-Won;Bang, Dong-Wan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.2
    • /
    • pp.81-87
    • /
    • 2006
  • Purpose: Few researches have been peformed on the dose distribution of the moving organ for radiotherapy so far. In order to simulate the organ motion caused by respiratory function, multipurpose phantom and moving device was used and dosimetric measurements for dose distribution of the moving organs were conducted in this study. The purpose of our study was to evaluate how dose distributions are changed due to respiratory motion. Materials and Methods: A multipurpose phantom and a moving device were developed for the measurement of the dose distribution of the moving organ due to respiratory function. Acryl chosen design of the phantom was considered the most obvious choice for phantom material. For construction of the phantom, we used acryl and cork with density of $1.14g/cm^3,\;0.32g/cm^3$ respectively. Acryl and cork slab in the phantom were used to simulate the normal organ and lung respectively. The moving phantom system was composed of moving device, moving control system, and acryl and cork phantom. Gafchromic film and EDR2 film were used to measure dose ditrbutions. The moving device system may be driven by two directional step motors and able to perform 2 dimensional movements (x, z axis), but only 1 dimensional movement(z axis) was used for this study. Results: Larger penumbra was shown in the cork phantom than in the acryl phantom. The dose profile and isodose curve of Gafchromic EBT film were not uniform since the film has small optical density responding to the dose. As the organ motion was increased, the blurrings in penumbra, flatness, and symmetry were increased. Most of measurements of dose distrbutions, Gafchromic EBT film has poor flatness and symmetry than EDR2 film, but both penumbra distributions were more or less comparable. Conclusion: The Gafchromic EBT film is more useful as it does not need development and more radiation dose could be exposed than EDR2 film without losing film characteristics. But as response of the optical density of Gafchromic EBT film to dose is low, beam profiles have more fluctuation at Gafchromic EBT. If the multipurpose phantom and moving device are used for treatment Q.A, and its corrections are made, treatment quality should be improved for the moving organs.

  • PDF

Facial Expression Control of 3D Avatar using Motion Data (모션 데이터를 이용한 3차원 아바타 얼굴 표정 제어)

  • Kim Sung-Ho;Jung Moon-Ryul
    • The KIPS Transactions:PartA
    • /
    • v.11A no.5
    • /
    • pp.383-390
    • /
    • 2004
  • This paper propose a method that controls facial expression of 3D avatar by having the user select a sequence of facial expressions in the space of facial expressions. And we setup its system. The space of expression is created from about 2400 frames consist of motion captured data of facial expressions. To represent the state of each expression, we use the distance matrix that represents the distances between pairs of feature points on the face. The set of distance matrices is used as the space of expressions. But this space is not such a space where one state can go to another state via the straight trajectory between them. We derive trajectories between two states from the captured set of expressions in an approximate manner. First, two states are regarded adjacent if the distance between their distance matrices is below a given threshold. Any two states are considered to have a trajectory between them If there is a sequence of adjacent states between them. It is assumed . that one states goes to another state via the shortest trajectory between them. The shortest trajectories are found by dynamic programming. The space of facial expressions, as the set of distance matrices, is multidimensional. Facial expression of 3D avatar Is controled in real time as the user navigates the space. To help this process, we visualized the space of expressions in 2D space by using the multidimensional scaling(MDS). To see how effective this system is, we had users control facial expressions of 3D avatar by using the system. As a result of that, users estimate that system is very useful to control facial expression of 3D avatar in real-time.

Postoperative Complications After Arthroscopic Anterior Cruciate Ligament Reconstruction Using Bone-Patellar Tendon-Bone Autograft (자가 슬개건을 이용한 전방 십자 인대 재건술의 수술 후 합병증)

  • Zhu, Fang Zhen;Yoo, Moon-Jib;Kim, Myung-Ho;Park, Hee-Gon;Bahng, Seung-Chul
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.7 no.2
    • /
    • pp.122-127
    • /
    • 2008
  • Purpose: Evaluation and analysis of the incidence of postoperative complications after arthroscopic anterior cruciate ligament reconstruction using bone-patellar tendon-bone autograft. Materials and Methods: We reviewed 172 cases of arthroscopic anterior cruciate ligament reconstruction using bone-patellar tendon-bone autograft in anterior cruciate ligament tear without meniscal injury. We performed Lysholm knee score and KT-2000 testing, simple radiograph, physical examination as evaluation factor. Also, around knee pain, swelling, limitation of motion, patellofemoral crepitation, paresthesia and pain on kneeling were evaluated. Results: The average follow up period was 49.8 months. In 172 patients, 148 males and 26 femlaes were evaluated. The average age was 34.4 years. The Lysholm knee score improved from 51.9 points preoperatively to 90.8 points at final follow up. Clinical outcome was excellent in 83%, good in 11%, fair in 4% and poor in 2%. There were many cases of complications, 24 cases (14%) of around knee pain, 12 cases (7%) of swelling, 45 cases (26.2%) of patellofemoral crepitation, 52 cases (30%) of donor site paresthesia, 65 cases (38%) of pain on kneeling, 10 cases (5.8%) of limitation of motion at extension, 13 cases (8%) of limitation of motion at flexion and 2cases (1.2%) of patellar fracture. Conclusion: Although arthroscopic anterior cruciate ligament reconstruction using bone-patellar tendon-bone had good clinical results, many complications were noted. Some factors in surgical technique were suspected to be related to the complications and long term follow up will be necessary to further evaluated.

  • PDF

ROC Analysis of Visual Assessments Made in Gated Blood Pool Scans of Patients with Coronary Artery Disease (관상동맥질환에서 심장풀 스캔의 육안적 평가에 대한 ROC 분석)

  • Lee, Kyun-Han;Choi, Yoon-Ho;Lee, Bum-Woo;Moon, Dae-Hyuk;Koong, Sung-Soo;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.23 no.2
    • /
    • pp.175-181
    • /
    • 1989
  • Visual assessment of regional wall motion abnormality (RWMA) by gated blood pol scan (GBPS) serves as an useful parameter in the diagnosis, functional evaluation, and follow up in various clinical settings, but are still subject to some inherent limitations. On important problem may be the interobserver as well as intraobsever variation that may well be present due to the subjective nature of the interpretations. This study was carried out to determine the reliability and reproducibility of visual assessments made in GBPSs, and to observe the degree to which the results would be influenced by observer variation. Fifty two patients with coronary heart disease had resting GBPS and contrast ventriculography within 4 days appall. Contrast ventriculography-showed normal wall motion in 6 patients and the remaining 46 had RWMA in one or more segments. The anterior and left anterolateral views of all 52 GBPSs were analyzed by three independent observers, who selected from 5 scales, their level of confidence that there was RWMA in that segment. Reciever operating characteristic (ROC) curves for each analysis was plotted and the area under the curve $(\theta)$ was used as a parameter representing each observer's performance in his interpretations. The findings of contrast ventriculographies were used as the standard for RWMA. The apical and inferoapical segments showed the best correlation with contrast ventriculography ($\theta=0.90-0.94$, 0.81-0.94, respectively), and the inferior wall showed the poorest correlation $(\theta=0.70-0.74)$. The interpretations of the inferior, septal, apical, and posteroinferior, segments showed no difference between the observers, but there was significantly better performance in assessment by observer A compared to that by B or C for the anterolateral segments ($\theta=0.87$, 0.78, 0.76, respectively. p<0.01 for A vs B, p<0.05 for A vs C), as well as when all segments were considered altogether ($\theta=0.88$, 0.83, 0.82, respectively. both p<0.05). This was also true for the infero-apical segment between A and C ($\theta=0.09$, 0.81, p<0.05). The intraobserver variation, however, did not appear significant, with only the inferior segment for observer B showing any significant difference when observer A and B repeated the analysis 10 days latter. There was no difference in assessing dyskinesia, with all observers showing a high performance ($\theta=0.98$, 0.87, 0.97, respectively). The visual assessment of left ventricular ejection fraction by all three observers correlated well with the calculated value from a semiautomated method (Spearman's r = 0.91, 0.83, 0.83. p<0.01, p<0.05, p < 0.05). The assessment of LV and RV size also correlated well between the three observers (Kendall's w = 0.80, 0.51, p<0.01 for both left and right ventricles). The above findings suggest that RWMA visually assessed by GBPS correlates well with that done by contrast ventriculography. And although the observer's experience or skill may influence the results in certain segments, visual analysis of GBPS may serve as a reliable and reproducible means for evaluating ventricular function.

  • PDF

A STUDY ON THE CHUMSUNGDAE'S FIGURES AND FUNCTIONS (첨성대 수치와 역할에 대한 연구)

  • Kim, Kwang-Tae
    • Publications of The Korean Astronomical Society
    • /
    • v.28 no.2
    • /
    • pp.25-36
    • /
    • 2013
  • Chumsungdae is an ancient astronomical observatory whose main role was doing 'chunmoon'. It was administrate by a royal advisory agency on state affairs. The observers observed the heaven on the observatory platform, recorded peculiar events, and watched and interpreted the signs displayed in the heaven. Chumsungdae is an stonemasonry which represents almanac principles with its peculiar shapes and the numbers of strata and stones. The numbers were thoroughly invented to match exactly the almanac constants. Chumsungdae is comprised largely of three main parts, namely the square base, the stratified cylindrical body, and the top #-shaped stonework, and the total number of stones is 404. The number of the strata (27) and the height of the cylindrical body (27 尺) stand for the days in a sidereal month (27.3 days), which implies that the motion of the Moon with respect to the stars was given more priority than to the Sun at that time of geocentricism. And the cylindrical body was thoroughly designed to consist of 365 stones, which is of course the number of days in a solar year. In addition, there are 12 strata each under and above the south entrance and this in sum makes the 24 divisions of the year. Also there is 182 stones below the 13th stratum and this represents the number of days in the winter ~ summer solstice period, and the rest 183 stones the vice versa. The #-shaped top stonework was aligned in such a way that one of the diagonals points the direction of sunrise on the winter solstice. The square base also layed with the same manner. The south entrance was built 16 degrees SE, and the upright direction of the right pillar stone coincides with the meridian circle. This was a kind of built-in standard meridian circle facilitating the observations. In a symbolic sense, Chumsungdae was thought as the tunnel reaching the heaven, where the observers wished to be enlightened with the signs and inspirations in need. With the craftsmanship and skill, the builder reinforced the stratified cylindrical body with two sets of #-shaped beam stones, piercing at a right angle at 19th ~ 20th and 25th ~ 26th strata. Likewise, by placing the double #-shaped stonework with 8 beam stones on the platform of the observatory, both the stability of the stonemasonry and a guard rail for the nightly observers were securely provided.

Arthroscopic Rotator Cuff Repair: Serial comparison of outcomes between full-thickness rotator cuff tear and partial-thickness rotator cuff tear

  • Park, Jin-Young;Chung, Kyung-Tae;Yoo, Moon-Jib
    • Clinics in Shoulder and Elbow
    • /
    • v.6 no.1
    • /
    • pp.72-79
    • /
    • 2003
  • Purpose: To compare the results of arthroscopic rotator cuff repair and subacromial decompression in partial thickness rotator cuff tear (PTRCT) with those in full thickness rotator cuff tear (FTRCT). Subjects and method: Of the 46 patients who were rested of the rotator cuff tear based on the operational findings, 42 patients who were able to receive a serial follow-up for 2 years were selected as the study subjects. The average age of the patients at the time of the operation was 55 years, and the mean duration of the follow-up was 34 months. The subjects included 22 cases of PTRCT and 20 cases of FTRCT. In terms of rotator cuff repair, the average number of tendon to tendon repair (TTR) was 1 in both PTRCT and FTRCT, and that of tendon to bone repair (TBR) was 1 and 3 in PTRCT and FTRCT, respectively. The average number of use of suture anchor was 1 and 2 in PTRCT and FTRCT, respectively. The level of shoulder pain and function of the subjects were measured using shoulder functional evaluation score of American shoulder and elbow society (ASES score) at before and 2 years following the operation. Results: At the final follow-up following the operation, PTRCT group showed changes in scores from 7.2 to 0.9 on average pain score and 34 to 91 on ASES score, whereas FTRCT group showed changes in scores from 7.6 to 1.2 on pain score and 29 to 88 on ASES score. There were no significant differences between the two groups (P > 0.05). The average range of motion of shoulder significantly increased in both groups at the final follow-up in comparison with the pre-operative time point. The evaluation at the final follow-up showed that 93% of the total subjects showed good or excellent results, and 95% showed satisfactory results from the procedure with regard to pain reduction and functional outcomes. Two cases of the 3 fair results were caused by acromioclavicular arthritis. Conclusion: It may be anticipated that arthroscopic rotator cuff repair and subacromial decompression may bring satisfactory post-operative outcomes in both PTRCT and FTRCT on pain relief and functional recovery. However, careful preoperative examination of the acromioclavicular joint is critical to avoid failures of these procedures.

Plantar Pressure in Skilled and Unskilled Players during Baseball Batting (야구 타격시 숙련자와 미숙련자의 족저압력 분석)

  • Moon, Won-Ho;Lee, Joong-Sook;Kim, Chang-Hyun;Jang, Young-Min;Jeong, Jin-Woo
    • Korean Journal of Applied Biomechanics
    • /
    • v.23 no.1
    • /
    • pp.25-35
    • /
    • 2013
  • This study examined 24 right-handed amateur baseball players. Twelve who had played baseball for more than 6 years were grouped as skilled players, while 12 who had played for 1-3 years were the unskilled player group. The swing motion was divided into four event phases: stance, backswing, impact, and follow-through. The mean and maximum plantar pressure, center of pressure, and ground reaction force were measured during each event phase. The mean and standard deviations for each variables were calculated and differences were validated with the independent sample t-test. A p-value <0.05 was considered statistically significant. The results were as follows. 1)The ideal stance is a stable, balanced position with more than 65% of weight on the right foot. There was significant difference in mean left plantar pressure, while the maximal plantar pressure and mean right plantar pressure did not differ significant. 2)The effective backswing of a skilled player is comprised a rightward shift in weight to build maximum energy. More than 90% of the weight was on the right foot. There was a significant difference in the mean left plantar pressure, while the maximal plantar pressure and mean right plantar pressure did not differ significantly. 3) For an effective impact, a rapid shift in weight to the left foot is essential, so that a power hit is obtained. Significant difference in the mean and maximum plantar pressures of both feet were observed. 4)Follow-through requires wight balance, more on the right than the left, without leaning leftward. There was no significant difference in the mean or maximum plantar pressure. 5)The center of plantar pressure should move from the center of the foot to the toe. 6)The analyses of the ground reaction force suggest that a good swing involves a gradual shift in weight to the right side and a rapid leftward shift at impact. Good balance, with the center of gravity on the right side at follow-through, is also required.

The Effect of an 8-week Shoulder Strengthening Exercise on Shoulder Muscle Strength of Caregivers (8주간의 어깨 강화 운동이 요양보호사들의 어깨 근력에 미치는 영향)

  • Shin, Jae-Wook;Lee, Seung-Min;Jung, Dae-Youn;Kim, Dong-In;Park, Jae-Sung;Lee, Byeong-Soo;Song, Se-Hee;Park, Lee-Dae;Kim, Moon-Jeong;Kim, No-Yong;Lee, Kwang-Hoon;Kim, Jae-Yong
    • PNF and Movement
    • /
    • v.16 no.1
    • /
    • pp.43-50
    • /
    • 2018
  • Purpose: This study examined the effects of a shoulder-strengthening exercise on muscle strength of shoulder flexors and extensors of caregivers. Methods: The study consisted of 19 caregivers (2 males and 17 females) employed by Medical Center B. All the participants took part in an 8-week shoulder muscle strengthening exercise, based on previous studies. In the first week, the subjects took part in a stretching exercise enhance the range of motion. In the second week, they participated in an exercise aimed at improving shoulder blade stability. From the third to seventh weeks, a resistance exercise of different intensities was applied in a phased manner. Finally, in the eight week, the subjects took part in plyometric exercise. Peak torque, average power, and total work of shoulder flexors and extensors in both sides were measured before and after the exercise at an angular speed of 120deg/sec using an isokinetic device. Wilcoxon's singed-ranks test was conducted to analyze differences in muscle strength before and after the intervention. Results: After the exercise, there was a significant improvement in peak torque and average power of flexors of the right arm. After the exercise, peak torque, total work, and average power showed a significant improvement in the flexors of the left arm (p<0.05). However, there was no statistically significant difference in extensor muscle strength in either arm after the exercise. Conclusion: Shoulder flexors of caregivers are utilized frequently in the workplace. Implementation of extensor-strengthening exercises, in addition to flexor-strengthening exercises, can contribute to reducing the incidence rate of shoulder injuries among caregivers.

Analysis of an internal flow with multi-perforated tube geometry in an integrated Urea-SCR muffler (다공튜브 형상변화에 따른 촉매 삽입형 Urea-SCR 머플러 내부유동 해석)

  • Moon, Namsoo;Lee, Sangkyoo;Lee, Jeekeun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.5
    • /
    • pp.500-509
    • /
    • 2013
  • This study reports a numerical analysis of the internal flow characteristics of the integrated urea-SCR muffler system with the various geometries of the multi-perforated tube which is set up between the muffler inlet and in front of SCR catalysts. The multi-perforated tube is generally used to disperse uniformly the urea-water solution spray and to make better use of the SCR catalyst, resulting in the increased $NO_x$ reduction and decreased ammonia slip. The effects of the multi-perforated tube orifice area ratios on the velocity distributions in front of the SCR catalyst, which is ultimately quantified as the uniformity index, were investigated for the optimal muffler system design. The steady flow model was applied by using a general-purpose commercial software package. The air at the room temperature was used as a working fluid, instead of the exhaust gas and urea-water solution spray mixture. From the analysis results, it was clarified that the multi-perforated tube geometry sensitively affected to the formation of the bulk swirling motion inside the plenum chamber set in front of the SCR catalyst and to the uniformity index of the velocity distribution produced at the inlet of the catalyst.

A Study on the Aesthetic Characteristics of the digital silhouette animation, (미셀 오슬로의 <밤의 이야기>를 통해 본 디지털 실루엣 애니메이션의 미학적 특성 연구)

  • Moon, Jae-Cheol;Kim, YoungOk
    • Cartoon and Animation Studies
    • /
    • s.32
    • /
    • pp.1-21
    • /
    • 2013
  • Silhouette Animation has been recognized as a genre of animation since the very beginning of the animation history, and also Its segmental movement and Aesthetic expression has led a variety of semantic interpretations. Especially the French animation director, Michel Ocelot, recently integrated 3-dimensional digital to the silhouettes animation, and it extended the possibility of the silhouettes animation in many aspects. In his latest animation feature, , he showed how he made changes in 3-dimension by creating and evolving his own way and style of silhouette animation. Although mainstream digital animations preferably to show realistic images and motion, Michel Ocelot used very selective movement, subjective digital colors and extended space which couldn't be expressed in the way of creating traditional style of silhouette animation. This alternative slow movement and the unique aesthetics in 3-dimension emphasize the unconscious elements of color, composition, patterns, and it provides digitally enhanced images and pictorial impression. In addition, the acquisition of digital three-dimensional use of space made possible to provides the wider formative imagination to the audience. In this paper, we analyzed aesthetic characteristics of the digital silhouette animation, (2011), specially focusing on the aspects of Movement, Image, Space, which could not be found in the traditional silhouette animation. It is significant to obtain diversity of the future digital animation and its positive development. In addition, this provides opportunity to explore Michel Ocelot's new experiments and animation philosophy.