• Title/Summary/Keyword: Motion Mechanism

Search Result 1,151, Processing Time 0.027 seconds

Analysis of Multiple Displacement Magnification Mechanism in Ultraprecision Nano Stage (초정밀 나노 스테이지에서의 다중 변위 확대 기구 해석)

  • Min K.S.;Choi W.C.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1273-1276
    • /
    • 2005
  • A displacement magnification mechanism is usually employed in a nano-positioning stage to achieve a large stage motion. A lever mechanism is the most widely used displacement magnifying mechanism. For more large stage motion, double or multiple lever mechanisms can be used. In this case, a more accurate analysis model is needed. This study proposes a more reasonable analysis model for a multiple lever mechanism based on the single lever mechanism model. This paper describes that the high equivalent stiffness of the lever is the most important factor reducing the magnification ratio of the lever mechanism through increasing the deflection of the link and including the axial displacement of the pivot.

  • PDF

Feasible Design Area of 4 Bar Input Crank for 3 Position Synthesis of Watt-II 6 Bar Mechanism (6 절기구 응용을 위한 3 위치 운동 생성용 4절 가구 합성을 위한 입력 크랭크의 합당해 영역)

  • 범진환
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.3
    • /
    • pp.88-98
    • /
    • 1998
  • In many automatization applications, a rigid body is required to go forward and backward repeatedly through a set of given position/orientations precisely while a crank is rotated. Such a motion can be generated by 6 bar mechanism adding a dyad to a 4 bar mechanism. If this is the case for 3 position synthesis of the 4 bar mechanism, the feasible solution area for designing the 4 bar mechanism will be limited over the general solution area. This paper proposes a procedure to synthesize 4 bar mechanism to be used to generate the required motion. It is found that the only input crank of the 4 bar mechanism should be limited to satisfy the condition. And the feasible design area for the circle point/ center point of the input crank is identified so that design of the undesired mechanism could be avoided. The method is tested and the results are shown.

  • PDF

Redundant Design of Wearable Robot Mechanism for Upper Arm (여자유도를 이용한 상지 착용형 로봇의 메커니즘 설계)

  • Lee, Young-Su;Hong, Sung-Jun;Jang, Hye-Yeon;Jang, Jae-Ho;Han, Chang-Su;Han, Jung-Su
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.7
    • /
    • pp.134-141
    • /
    • 2009
  • Recently, many researchers have tried to develop wearable robots for various fields such as medical and military purposes. We have been studying robotic exoskeletons to assist the motion of persons who have problems with their muscle function in daily activities and rehabilitation. The upper-limb motions (shoulder, elbow and wrist motion) are especially important for such persons to perform daily activities. Generally for shoulder motion 300F is needed to describe its motion(extension/flexion, abduction/adduction, internal/external rotation) but we have used a redundant actuator thus making a 4 DOF system. In this paper, we proposed the mechanism design of the exoskeleton which consists of 4-DOF for shoulder and 1-DOF for elbow robotic exoskeleton to assist upper-limb motion. Then we compared the new mechanism design and prototype mechanism design. Here we also analyze the proposed system kinematically to find out and to avoid the singular point. This research will ensure that the proposed wearable robot system make human's motion more powerfully and more easily.

Kinematic Analysis of a Continuously Variable Valve Actuation Mechanism with Movable Second Cam Center (2차 캠 중심 이동형 연속가변밸브 구동기구의 기구학 해석)

  • Kim, Do-Joong;Kim, Yong-Hyun
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.17 no.5
    • /
    • pp.7-15
    • /
    • 2009
  • This paper introduces a new variable valve actuation mechanism with movable second cam center. Valve lift and open duration can be continuously varied according to engine speed and load conditions. A new method to analyze the kinematic relations between the first and second cam profiles and valve motion are also introduced. Because of rocker motion of the second cam, conventional motion conversion program could not be used in this problem. An example shows continuous variations of valve motion and adequate ramp incorporation throughout all valve lift modes. Valve acceleration profile at the high lift mode is similar to that of conventional valvetrains. Contact geometry analysis of the mechanism gives basic information on the load conditions between the components.

A Study on the Mechanism of Arm Surface Changes for the development of Sleeve Drafting Standard (소매설계기준 개발을 위한 상지체표변화구조에 관한 연구)

  • 최해주
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.20 no.5
    • /
    • pp.852-859
    • /
    • 1996
  • The factors and mechanism of arm surface changes were analyzed by regression analysis for the relationship between changes in arm joint angle and arm surface changes, according to the direction of upper extremity motion. Body surface change patterns among subjects were tested also. Experiments were carried out on 3 female subjects of different body types to examine 26 motions in 4 directions for 4 upper extremity parts. The major conclusions of the study are as follows: 1. The expansion or contraction of arm surface length depends on the direction of upper extremity motion. 2. Arm surface length changes by linear expansion or contraction according to the joint angle of the direction of motion. The mechanism of arm surface changes is represented by a linear relation between arm surface changes and the (actors of the direction of upper extremity motion and arm joint angle. 3. Arm surface length shows the same pattern of body surface changes regardless of body type. A quantitative model of body surface changes at upper extremity should be developed for functional sleeve design.

  • PDF

Mechanism Design of the Interactive Emotional Robot (대화형 감성 로봇의 메커니즘 설계)

  • 김연훈;윤석준;이동연;곽윤근
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2001.11a
    • /
    • pp.233-238
    • /
    • 2001
  • The mechanism design of the interactive emotional robot has been carried out. The two-wheeled inverted pendulum type mechanism was adopted to improve the mobility and make the innate clumsy monoaxial bicycle motion. Even though the system is unstable in itself, it is expected for the robot to move freely in a plane, keeping the upright position only with two wheels. Two motors attached on head can make 4 motion sets, and two motors on the wheels can make 8. Therefore, 32 independent motion sets can be achieved from the robot to communicate the emotions with humans. The motion's equation of the robot was derived based on nonholonomic dynamics, and the necessary power to the wheel's rotational axis was found by simulation.

  • PDF

Improvement based on Jansen mechanism in moving vehicles and exploration equipment sector. (이동차량 및 탐사용 장비 분야에서 Jansen 메커니즘을 통하여 정숙성/굴곡지 형 이동성능 개선에 관한 연구)

  • Park, Minjae
    • Proceeding of EDISON Challenge
    • /
    • 2016.03a
    • /
    • pp.516-517
    • /
    • 2016
  • I use Jansen mechanism to reduce the unnecessary motion of car body and improve the motion performance capability in the rugged terrain To reduce the unnecessary motion, the positional variation of a main body of vehicle should be minimized. In order to reduce the change of height and control the speed at every moment when vehicle move, 16 legs or more are installed on a crankshaft and the paths of leg motions need to be considered in the rugged terrain. The vehicle will be optimized so that it produces a sufficient speed and torque for practical use. Finally, I designed proper body with Edison simulation. The simulation is good for beginners of mechanism design.

  • PDF

Physicians' Requirement Analysis Based Design of the Master Device Mechanism for Teleoperated Interventional Robotic System (원격 중재시술용 마스터장치에 대한 의료진 요구분석 및 이를 반영한 메커니즘 설계)

  • Woo, Hyun Soo;Cho, Jang Ho;Lee, Hyuk Jin
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.8
    • /
    • pp.603-609
    • /
    • 2016
  • This paper presents an optimally designed master device mechanism for teleoperated interventional robotic system. The interventional procedures using the teleoperated robotic system and the physicians' requirements are summarized. The master device should implement 5-DOF motion including 2-DOF translational motion for the entry position control, 2-DOF rotational motion for the orientation control, and 1- DOF translational motion for needle insertion. The handle assembly includes a 1-DOF translational mechanism for needle insertion and buttons for operation mode selection. The mechanisms for the 2-DOF translational motion and the 2-DOF rotational motion are designed using motors and brakes based on the various mechanisms to satisfy all the above requirements, respectively. Absolute position sensors are adopted to implement automatic initial positioning and orientation matching at the first step of needle insertion.

Evaluation of the added mass for a spheroid-type unmanned underwater vehicle by vertical planar motion mechanism test

  • Lee, Seong-Keon;Joung, Tae-Hwan;Cheon, Se-Jong;Jang, Taek-Soo;Lee, Jeong-Hee
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.3 no.3
    • /
    • pp.174-180
    • /
    • 2011
  • This paper shows added mass and inertia can be acquired from the pure heaving motion and pure pitching motion respectively. A Vertical Planar Motion Mechanism (VPMM) test for the spheroid-type Unmanned Underwater Vehicle (UUV) was compared with a theoretical calculation and Computational Fluid Dynamics (CFD) analysis in this paper. The VPMM test has been carried out at a towing tank with specially manufactured equipment. The linear equations of motion on the vertical plane were considered for theoretical calculation, and CFD results were obtained by commercial CFD package. The VPMM test results show good agreement with theoretical calculations and the CFD results, so that the applicability of the VPMM equipment for an underwater vehicle can be verified with a sufficient accuracy.

Analysis on Kinematic Characteristics for Spatial 3-DOF Parallel Mechanisms Employing Stewart Platform Structure (스튜워트 플랫폼 구조를 이용한 공간형 3자유도 병렬 메커니즘의 기구학 특성 분석)

  • Lee Seok Hee;Lee Jung Hun;Kim Whee Kuk;Yi Byung Ju
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.8 s.173
    • /
    • pp.118-127
    • /
    • 2005
  • A spatial 3 degrees-of-freedom mechanism employing Stewart Platform structure is proposed: the mechanism maintains the 3- RRPS structure of Stewart Platform but has an additional passive PRR serial sub-chain at the center area of the mechanism in order to constrain the output motion of the mechanism within the output motion space of the added PRR serial subchain. The forward and reverse position analyses of the mechanism are performed. Then the mechanism having both the forward and the reverse closed-form solutions is suggested and its closed form solutions are derived. It is confirmed, through the kinematic analysis of those two proposed mechanisms via kinematic isotropic index, that both the proposed mechanisms have fairly good kinematic characteristics compared to the existing spatial 3-DOF mechanisms in literature.