• Title/Summary/Keyword: Motion Information of Target

Search Result 201, Processing Time 0.027 seconds

Adaptive Hard Decision Aided Fast Decoding Method using Parity Request Estimation in Distributed Video Coding (패리티 요구량 예측을 이용한 적응적 경판정 출력 기반 고속 분산 비디오 복호화 기술)

  • Shim, Hiuk-Jae;Oh, Ryang-Geun;Jeon, Byeung-Woo
    • Journal of Broadcast Engineering
    • /
    • v.16 no.4
    • /
    • pp.635-646
    • /
    • 2011
  • In distributed video coding, low complexity encoder can be realized by shifting encoder-side complex processes to decoder-side. However, not only motion estimation/compensation processes but also complex LDPC decoding process are imposed to the Wyner-Ziv decoder, therefore decoder-side complexity has been one important issue to improve. LDPC decoding process consists of numerous iterative decoding processes, therefore complexity increases as the number of iteration increases. This iterative LDPC decoding process accounts for more than 60% of whole WZ decoding complexity, therefore it can be said to be a main target for complexity reduction. Previously, HDA (Hard Decision Aided) method is introduced for fast LDPC decoding process. For currently received parity bits, HDA method certainly reduces the complexity of decoding process, however, LDPC decoding process is still performed even with insufficient amount of parity request which cannot lead to successful LDPC decoding. Therefore, we can further reduce complexity by avoiding the decoding process for insufficient parity bits. In this paper, therefore, a parity request estimation method is proposed using bit plane-wise correlation and temporal correlation. Joint usage of HDA method and the proposed method achieves about 72% of complexity reduction in LDPC decoding process, while rate distortion performance is degraded only by -0.0275 dB in BDPSNR.

The Effect of Vision and Proprioception on Lumbar Movement Accuracy (시각과 고유수용성 감각이 요부 운동의 정확도에 미치는 영향)

  • Sim, Hyun-Po;Yoon, Hong-Il;Youn, I-Na
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.13 no.2
    • /
    • pp.31-44
    • /
    • 2007
  • The purposes of this study were to examine the normal lumbar proprioception and identify the effect of vision and proprioception on lumbar movement accuracy through measuring a reposition error in visual and non-visual conditions and to provide the basic data for use of vision when rehabilitation program is applied. The subjects of this study were 39 healthy university students who have average physical activity level. They were measured the ability to reproduce the target position(50% of maximal range of motion) of flexion, extension, dominant and non-dominant side flexion in visual and non-visual conditions. Movement accuracy was assessed by reposition error(differences between intended and actual positions) that is calculated by the average of absolute value of 3 repeated measures at each directions. The data were analysed by paired samples t-test, independent samples t-test, and repeated measures ANOVA. The results were as follows : 1. Movement accuracy of flexion, extension, dominant side flexion, and non-dominant side flexion was increased in visual condition. 2. There were no differences in the lumbar movement accuracy between sexes in visual and non-visual conditions. 3. In non-visual condition, the movement in coronal plane(dominant and non dominant side flexion) is more accurate than that in sagittal plane(flexion and extension). 4. In non-visual condition, there were no differences in the lumbar movement accuracy between dominant and non-dominant side flexion. In conclusion, this study demonstrates that the movement is more accurate when the visual information input is available than proprioception is only available. When proprioception is decreased by injury or disease, it disturbs the control of posture and movement. In this case, human controls the posture and movement by using visual compensation. However it is impossible to prevent an injury or trauma because most of injuries occur in an unexpected situation. For this reason, it is important to improve the proprioception. Therefore, proprioceptive training or exercise which improve the ability to control of posture and movement is performed an appropriate control of permission or interception of the visual information input to prevent an excessive visual compensation.

  • PDF

Rate Control based on linear relation for H.264/MPEG-4 AVC (선형 관계를 이용한 H.264/MPEG-4 AVC 비트율 제어 방법)

  • Na Hyeong-Youl;Lim Sung-Chang;Lee Yung-Lyul
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.43 no.1 s.307
    • /
    • pp.27-38
    • /
    • 2006
  • The main purpose of rate control is to achieve the highest video quality when bandwidth or storage capacity is limited. For this purpose, we need a rate control algorithm which is adaptively controlled by the motion information of sequences, scene change, buffer capacity and time-varing bandwitdh channels. A rate-control method in the encoder requires the accurate estimation of target bit for each frame and the low end-to-end delay for transmitting video data by intelligent selection of encoding parameters. In this paper, we suggest three kinds of linear relation in the encoder to satisfy the characteristics of rate control. The first relation is that between the percentage of zero quantized transformed coefficients(p) and coded bits. Second relation is that between the PSNR of encoded frame and its Quantization parameter(QP). Finally, we can find out a linear approximation between QP and p. According to the experimental analysis, the proposed method results in an efficient rate control in terms of the bit estimation, the buffer capacity, and PSNR compared with the existing rate control in the H.264 JM 9.3.

Design and Strength Analysis of a Mast and Mounting Part of Dummy Gun for Multi-Mission Unmanned Surface Vehicle (복합임무 무인수상정의 마스트 및 특수임무장비 장착부 설계 및 강도해석)

  • Son, Juwon;Kim, Donghee;Choi, Byungwoong;Lee, Youngjin
    • The Journal of Korean Institute of Information Technology
    • /
    • v.16 no.11
    • /
    • pp.51-59
    • /
    • 2018
  • The Multi-Mission Unmanned Surface Vehicle(MMUSV), which is manufactured using glass Fiber Reinforced Plastic(FRP) material, is designed to perform a surveillance and reconnaissance on the sea. Various navigation sensors, such as RADAR, RIDAR, camera, are mounted on a mast to perform an autonomous navigation. And a dummy gun is mounted on the deck of the MMUSV for a target tracking and disposal. It is necessary to analyze a strength for structures mounted on the deck because the MMUSV performs missions under a severe sea state. In this paper, a strength analysis of the mast structure is performed on static loads and lateral external loads to verify an adequacy of the designed mast through a series of simulations. Based on the results of captive model tests, a strength analysis for a heave motion of the mast structure is conducted using a simulation tool. Also a simulation and fatigue test for a mounting part between the MMUSV and the dummy gun are performed using a specimen. The simulation and test results are represented that a structure of the mast and mounting part of the dummy gun are appropriately designed.he impact amount are performed through simulation and experiments.

Trend and future prospect on the development of technology for electronic security system (기계경비시스템의 기술 변화추세와 개발전망)

  • Chung, Tae-Hwang;So, Sung-Young
    • Korean Security Journal
    • /
    • no.19
    • /
    • pp.225-244
    • /
    • 2009
  • Electronic security system is composed mainly of electronic-information-communication device, so system technology, configuration and management of the electronic security system could be affected by the change of information-communication environment. This study is to propose the future prospect on the development of technique for electronic security system through the analysis of the trend and the actual condition on the development of technique. This study is based on literature study and interview with user and provider of electronic security system, also survey was carried out by system provider and members of security integration company to come up with more practical result. Hybrid DVR technology that has multi-function such as motion detection, target tracking and image identification is expected to be developed. And 'Embedded IP camera' technology that internet server and image identification software are built in. Those technologies could change the configuration and management of CCTV system. Fingerprint identification technology and face identification technology are continually developed to get more reliability, but continual development of surveillance and three-dimension identification technology for more efficient face identification system is needed. As radio identification and tracking function of RFID is appreciated as very useful for access control system, hardware and software of RFID technology is expected to be developed, but government's support for market revitalization is necessary. Behavior pattern identification sensor technology is expected to be developed and could replace passive infrared sensor that cause system error, giving security guard firm confidence for response. The principle of behavior pattern identification is similar to image identification, so those two technology could be integrated with tracking technology and radio identification technology of RFID for total monitoring system. For more efficient electronic security system, middle-ware's role is very important to integrate the technology of electronic security system, this could make possible of installing the integrated security system.

  • PDF

The Dynamic Basement Amplification Characteristics of a Dam Site using a Reference Site Method (기준관측소 방법을 이용한 댐체 기반암의 동적 지반증폭특성)

  • Wee, Soung-Hoon;Kim, Jun-Kyoung;Yoo, Seong-Hwa
    • Journal of the Korean earth science society
    • /
    • v.38 no.2
    • /
    • pp.161-171
    • /
    • 2017
  • Observed ground motions are composed of three factors such as, seismic source, attenuation, and site amplification effect. Among them, the site amplification characteristics should be considered significantly when estimating seismic source and attenuation characteristics with more confidence. The site effect is also necessary when estimating not only seismic hazard in seismic design engineering but also rock mechanical properties. This study uses the method of H/V spectral ratio of observed ground motion between target site and reference site called a reference site method. In addition to using the vertical Fourier spectrum of the reference site, we try out the horizontal Fourier spectrum as a new method in this study. We analyze H/V spectral ratio of six ground motions respectively, observed at four sites close to Yedang Reservoir. We then compare site amplification effects at each site using 3 kinds of seismic energies including S waves, Coda waves energy, and background noise. The results suggest that each site showed similar site amplification patterns in S waves and Coda waves energy. However, the site amplification of background noise shows much different characteristics from those of S waves and Coda wave energy, which suggests that the background noises at each site have their own developing mechanism. Each station shows its own characteristics of specific resonance frequency and site amplification properties in low, high and specific resonance frequency ranges. Comparison of the method used in this study to the others that used different methods can provide us with more information about the dynamic amplification of a site characteristics and site classification.

Analysis of Correlation Coefficient Between Movements of Thoracoabdominal Tumors and External Respiration Using Image Guided Radiotherapy(IGRT) (영상유도 방사선치료장치(IGRT)를 이용한 흉·복부 종양의 움직임과 외부호흡과의 상관관계 분석)

  • Kim, Gha-Jung;Hong, Ju-Youn;Han, Sang-Hyun
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.9
    • /
    • pp.362-370
    • /
    • 2014
  • This study measured and analyzed the correlation coefficient between movements of thoracoabdominal tumors and external respiration in a free-breathing state, using cyberknife image guided radiotherapy(IGRT). This study subjects included a total of 30 patients with lung tumors(n=10), liver tumors(n=10) and pancreatic tumor(n=10) who underwent radiotherapy, and the movements of tumors were analyzed using converted log data of the tumor motion tracking system(MTS). In a free-breathing state, In relation to Peason's correlation coefficient between external respiration and lung tumors in the entire treatment process, the correlation coefficient was 0.646(p<0.05) in the cranio-caudal direction, 0.365(p<0.088) in the left and right direction and 0.196(p<0.115) in the antero-posterior direction. The correlation coefficient of liver tumors was 0.841(p<0.000) in the cranio-caudal direction, 0.346 (p<0.179) in the left and right direction and 0.691(p<0.001) in the antero-posterior direction. The correlation coefficient of Pancreatic tumors was 0.683(p<0.000) in the cranio-caudal direction, 0.397(p<0.006) in the left and right direction and 0.268(p<0.127) in the antero-posterior direction. In conclusion, the measurement findings of thoracoabdominal tumor movement using IGRT would be helpful in determining an accurate target volume. Moreover, the analysis of correlation between external respiration and movements of internal tumors would provide important information to correct movements of tumors for diverse radiotherapy techniques.

Extraction of Ocean Surface Current Velocity Using Envisat ASAR Raw Data (Envisat ASAR 원시자료를 이용한 표층 해류 속도 추출)

  • Kang, Ki-Mook;Kim, Duk-Jin
    • Korean Journal of Remote Sensing
    • /
    • v.29 no.1
    • /
    • pp.11-20
    • /
    • 2013
  • Space-borne Synthetic Aperture Radar(SAR) has been one of the most effective tools for monitoring quantitative oceanographic physical parameters. The Doppler information recorded in single-channel SAR raw data can be useful in estimating moving velocity of water mass in ocean. The Doppler shift is caused by the relative motion between SAR sensor and the water mass of ocean surface. Thus, the moving velocity can be extracted by measuring the Doppler anomaly between extracted Doppler centroid and predicted Doppler centroid. The predicted Doppler centroid, defined as the Doppler centroid assuming that the target is not moving, is calculated based on the geometric parameters of a satellite, such as the satellite's orbit, look angle, and attitude with regard to the rotating Earth. While the estimated Doppler shift, corresponding to the actual Doppler centroid in the situation of real SAR data acquisition, can be extracted directly from raw SAR signal data, which usually calculated by applying the Average Cross Correlation Coefficient(ACCC). The moving velocity was further refined to obtain ocean surface current by subtracting the phase velocity of Bragg-resonant capillary waves. These methods were applied to Envisat ASAR raw data acquired in the East Sea, and the extracted ocean surface currents were compared with the current measured by HF-radar.

A Study on Korean Speech Animation Generation Employing Deep Learning (딥러닝을 활용한 한국어 스피치 애니메이션 생성에 관한 고찰)

  • Suk Chan Kang;Dong Ju Kim
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.12 no.10
    • /
    • pp.461-470
    • /
    • 2023
  • While speech animation generation employing deep learning has been actively researched for English, there has been no prior work for Korean. Given the fact, this paper for the very first time employs supervised deep learning to generate Korean speech animation. By doing so, we find out the significant effect of deep learning being able to make speech animation research come down to speech recognition research which is the predominating technique. Also, we study the way to make best use of the effect for Korean speech animation generation. The effect can contribute to efficiently and efficaciously revitalizing the recently inactive Korean speech animation research, by clarifying the top priority research target. This paper performs this process: (i) it chooses blendshape animation technique, (ii) implements the deep-learning model in the master-servant pipeline of the automatic speech recognition (ASR) module and the facial action coding (FAC) module, (iii) makes Korean speech facial motion capture dataset, (iv) prepares two comparison deep learning models (one model adopts the English ASR module, the other model adopts the Korean ASR module, however both models adopt the same basic structure for their FAC modules), and (v) train the FAC modules of both models dependently on their ASR modules. The user study demonstrates that the model which adopts the Korean ASR module and dependently trains its FAC module (getting 4.2/5.0 points) generates decisively much more natural Korean speech animations than the model which adopts the English ASR module and dependently trains its FAC module (getting 2.7/5.0 points). The result confirms the aforementioned effect showing that the quality of the Korean speech animation comes down to the accuracy of Korean ASR.

Patients with brain metastases the usefulness of contrast-enhanced FLAIR images after delay (뇌전이 환자의 조영 증강 후 지연 FLAIR 영상의 유용성)

  • Byun, Jae-Hu;Park, Myung-Hwan;Lee, Jin-Wan
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.16 no.1
    • /
    • pp.13-19
    • /
    • 2014
  • Purpose: FLAIR image is beneficial for the diagnosis of various bran diseases including ischemic CVS, brain tumors and infections. However the border between the legion of brain metastasis and surrounding edema may not be clear. Therefore, this study aims to investigate the practical benefits of delayed imaging by comparing the image from a patient with brain metastasis before a contrast enhancement and the image 10 minutes after a contrast enhancement. Materials and methods: Of the 92 people who underwent MRI brain metastases in suspected patients 13 people in three patients there is no video to target the 37 people confirmed cases, and motion artifacts brain metastases in our hospital June-December 2013, 18 people measurement position except for the three incorrect patient (male: 11 people, female: 7 people, average age: 60 years) in the target, test equipment, 3.0T MR System (ACHIEVA Release, Philips, I was 8ChannelSENSE Head Coil use Best, and the Netherlands). TR 11000 ms, TE 125 ms, TI2800 ms, Slice Thickness 5 mm, gap 5 mm, is a Slice number 21, the parameters of the 3D FFE, T2 FLAIR variable that was used to test, TR 8.1 ms, TE 3.7 ms, Slice number 240 I set to. The experiment was conducted by acquiring the FLAIR prior to contrast enhancement (heretofore referred to as Pre FLAIR), and acquiring the 3D FFE CE five minutes after the contrast enhancement, and recomposing the images in an axial plane of S/T 3mm, G 0mm (heretofore referred to as MPR TRA CE). Using the FLAIR 10 minutes after the contrast enhancement (heretofore referred to as Post FLAIR) and Pi-View, a retrospective study was conducted. Using MRIcro on the image of a patient confirmed for his diagnosis, the images before and after the contrast media, as well as the CNR and SNR of the MPR TRA CE images of the lesion and the site absent of lesion were compared and analyzed using a one-way analysis of variance. Results: CNR for Pre FLAIR and Post FLAIR were 34.35 and 60.13, respectively, with MPR TRA CE at 23.77 showing no significant difference (p<0.050). Post-experiment analysis shows a difference between Pre FLAIR and Post FLAIR in terms of CNR (p<0.050), but no difference in CNR between Post FLAIR and MPR TRA CE (p>0.050), indicating that the contrast media had an effect only on Pre FLAIR and Post FLAIR. The SNR for the normal site Pre FLAIR was 106.43, and for the lesion site 140.79. Post FLAIR for the normal site was 107.79, and for the lesion site 167.91. MPR TRA CE for the normal site was 140.23 and for the lesion site 183.19, showing significant difference (p<0.050), and post-experiment analysis shows that there was a difference in SNR only on the lesion sites for Pre FLAIR and Post FLAIR (p<0.050). There was no difference in SNR between the normal site and lesion site for Post FLAIR and MPR TRA CE, indicating no effect from the contrast media (p>0.050). Conclusions: This experiment shows that Post FLAIR has a higher contrast than Pre FLAIR, and a higher SNR for lesions, It was not not statistically significant and MPR TRA CE but CNR came out high. Inspection of post-contrast which is used in a high magnetic field is frequently used images of 3D T1 but, since the signal of the contrast medium and the blood flow is included, this method can be diagnostic accuracy is reduced, it is believed that when used in combination with Post FLAIR, and that can provide video information added to the diagnosis of brain metastases.

  • PDF