• Title/Summary/Keyword: Motion Artifacts

Search Result 178, Processing Time 0.024 seconds

Interpolation Error Concealment Method of Motion Compensated Interpolated Frame for Motion Compensated Frame Rate Conversion (움직임 보상 프레임 율 변환 기법을 위한 움직임 보상 보간 프레임의 보간 오류 은닉 기법)

  • Lee, Jeong-Hun;Han, Dong-Il
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.927-928
    • /
    • 2008
  • In this paper, a interpolation error concealment algorithm of motion compensated interpolated frame for motion compensated frame rate conversion to reduce the block artifacts caused by failure of conventional motion estimation based on block matching algorithm is proposed. Experimental results show good performance of the proposed scheme with significant reduction of the block artifacts.

  • PDF

Frame Rate Up-Conversion Using the Motion Vector Correction based on Motion Vector Frequency of Neighboring blocks (주변 블록의 움직임 벡터 빈도수에 기반한 움직임 벡터 교정을 적용한 프레임 율 변환 기법)

  • Lee, Jeong-Hun;Han, Dong-Il
    • Proceedings of the IEEK Conference
    • /
    • 2007.07a
    • /
    • pp.259-260
    • /
    • 2007
  • In this paper, a frame rate up-conversion algorithm using the motion vector frequency of neighboring blocks to reduce the block artifacts caused by failure of conventional motion estimation based on block matching algorithm is proposed. Experimental results show good performance of the proposed scheme with significant reduction of the erroneous motion vectors and block artifacts.

  • PDF

Design of Motion Artifacts Filter of PPG Signal based on Kalman filter and Adaptive filter (칼만필터와 적응필터를 기반한 PPG 동잡음 제거 필터 설계)

  • Lee, Byeong-Ro;Lee, Ju-Won
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.4
    • /
    • pp.986-991
    • /
    • 2014
  • The PPG signal used in mobile-healthcare and telemedicine system is including the various motion artifact that is signal generated from patient's movements. Recently, although the various methods to remove motion artifacts have been suggested, the performances of these methods are still not satisfactory. Therefore, this s study suggested the novel method based on the Kalman filter and adaptive filter to remove motion artifacts, and we used various motion artifacts to analyze the performance of the proposed method. In the results of experiments, the signal-to-noise ratio of proposed method showed good performace that was 4.8 times of moving average filter.

Light Modulation based on PPG Signal Processing for Biomedical Signal Monitoring Device (생체 정보 감시 장치를 위한 광변조 기법의 PPG 신호처리)

  • Lee, Han-Wook;Lee, Ju-Won;Jeong, Won-Geun;Kim, Seong-Hoo;Lee, Gun-Ki
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.6
    • /
    • pp.503-509
    • /
    • 2009
  • The development of technology has led to ubiquitous health care service, which enables many patients to receive medical services anytime and anywhere. For the ubiquitous health care environment, real-time measurement of biomedical signals is very important, and the medical instruments must be small and portable or wearable. So, such devices have been developed to measure biomedical signals. In this study, we develop the biomedical monitoring device which is sensing the PPG signal, one of the useful signal in the field of ubiquitous healthcare. We design a watch-like biomedical signal monitoring system without a finger probe to prevent the user's inconvenience. This system obtains the PPG from the radial artery using a sensor in the wrist band. But, new device developed in this paper is easy to get the motion artifacts. So, we proposed new algorithm removing the motion artifacts from the PPG signal. The method detects motion artifacts by changing the degree of brightness of the light source. If the brightness of the light source is reduced, the PPG pulses will disappear. When the PPG pulses have disappeared completely, the remaining signal is not the signal that results from the changing blood flow. We believe that this signal is the motion artifact and call it the noise reference signal. The motion artifacts are removed by subtracting the noise reference signal from the input signal. We apply this algorithm to the system, so we can stabilize the biomedical monitoring system we designed.

Motion-Compensated Interpolation for Non-moving Caption Region (정지자막 영역의 움직임 보상 보간 기법)

  • Lee, Jeong-Hun;Han, Dong-Il
    • Proceedings of the IEEK Conference
    • /
    • 2007.07a
    • /
    • pp.363-364
    • /
    • 2007
  • In this paper, we present a novel motion-compensated interpolation technique for non-moving caption region to prevent the block artifacts due to the failure of conventional block-based motion estimation algorithm on the block is consist of non-moving caption and moving object. Experimental results indicate good performance of the proposed scheme with significantly reduced block artifacts on image sequence that include non-moving caption. Also the proposed method is simple and adequate for hardware implementation.

  • PDF

Development of Reflected Type Photoplethysmorgraph (PPG) Sensor with Motion Artifacts Reduction (생명신호 측정용 반사형 광용적맥파 측정기의 움직임에 의한 신호왜곡 제거)

  • Han, Hyo-Nyoung;Lee, Yun-Joo;Kim, Jung-Sik;Kim, Jung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.12
    • /
    • pp.146-153
    • /
    • 2009
  • One of the most important issues in the wearable healthcare sensors is to minimize the motion artifacts in the vital signals for continuous monitoring. This paper presents a reflected type photoplethysmograph (PPG) sensor for monitoring heart rates at the artery of the wrist. Active noise cancellation algorithm was applied to compensate the distorted signals by motions with Least Mean Square (LMS) adaptive filter algorithms, using acceleration signals from a MEMS accelerometer. Experiments with a watch type PPG sensor were performed to validate the proposed algorithm during typical daily motions such as walking and running. The developed sensor is suitable for ubiquitous healthcare system and monitoring vital arterial signals during surgery.

Characterization of Motion Interpolation in 120Hz Systems

  • Shin, Byung-Hyuk;Kim, Kyung-Woo;Park, Min-Kyu;Berkeley, Brian H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.681-684
    • /
    • 2008
  • Motion interpolation is adopted and has been spread widely into market since it is effective in reducing motion blur, which is considered as weak characteristic due to slow response time of liquid crystal and hold-type display. 120Hz driving using interpolated frames achieves better moving picture quality with less motion blur and less motion judder. However, errors in the interpolated frames can cause visual artifacts such as static text breakup, halos, and occlusions. This paper focuses on categorizing characteristics of visual artifacts and on reducing side-effects by using information from original frames in special cases.

  • PDF

Development of Respiratory Monitoring System by Inductive Plethysmography (인덕턴스 호흡감시 시스템의 개발)

  • Kim, Deok-Won;Yeon, Dong-Su;Kim, Su-Chan
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.3
    • /
    • pp.353-358
    • /
    • 1995
  • The impedance pneumography which is widely used in monitoring respiration is simple to use and noninvasive, but it is sensitive to motion artifacts and insensitive to detect obstructive apnea. A 3-channel respiratory inductive plethysmography (RIP) developed in this study detects inductance change of the inductance band induced by cross-sectional area change of thorax or abdomen as one breathes. It was confirmed that RIP was less sensitive to various motion artifacts but more sensitive to detection of obstructive apnea than impedance pneumography.

  • PDF

Motion Artifacts reduction from the PPG based on the Improved PMAF for the U-Healthcare System (U-헬스케어 시스템을 위한 개선된 PMAF 기반의 PPG 신호의 동잡음 제거)

  • Lee, Han-Wook;Lee, Ju-Won;Jeong, Won-Geun;Jun, Jae-Chul;Lee, Gun-Ki
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.45 no.5
    • /
    • pp.28-34
    • /
    • 2008
  • The real-time biomedical signal monitoring is a very important factor to realize the ubiquitous healthcare environment. Most of these devices for monitoring the biomedical information get the PPG signal from the user, and these signals are utilized for monitoring their health. It is inconvenient to get the PPG because the user should wear the finger probe with his finger for measuring the PPG signal. Also it is difficult to get the PPG correctly, because of the motion artifacts from the movement of the user. In this paper, we develop the watch type biomedical signal monitoring system without the finger probe, and propose the new algorithm for reducing the motion artifacts from the PPG signal. We designed the system which gets the PPG from the sensor on the wrist band strip. As compared with the finger probe type, this system we proposed is more affected by the motion artifacts. So to filter this motion artifacts, we propose the new method; the improved PMAF(Periodic Moving Average Filter) method.

De-interlacing Algorithm based on Motion Compensation Reliability (움직임 보상의 신뢰도에 기반 한 순차주사화 알고리즘)

  • Chang, Joon-Young;Kim, Young-Duk;Kang, Moon-Gi
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.46 no.6
    • /
    • pp.102-111
    • /
    • 2009
  • In this paper, we propose a de-interlacing algorithm that combines a motion compensation (MC) method and the vertical-temporal filter with motion compensation (MC V-T filter) according to motion compensation reliability. The MC method represent one of the best ways of improving the resolution of de-interlaced frames, but it may introduce motion compensation artifacts in regions with incorrect motion information. In these regions, the MC V-T filter that is very robust to motion vector errors can be used to correct motion compensation artifacts. The combination between two methods is controlled by the motion compensation reliability that is measured by analyzing the estimated motion vectors and the results of MC. The motion compensation reliability contains information about motion compensation artifacts of MC results and determines the combination weight according to this information. Therefore, the combination rule of the proposed method is more accurate than those of the conventional methods and it enables the proposed method to provide high quality video sequences without producing any visible artifacts. Experimental results with various test sequences show that the proposed algorithm outperforms conventional algorithms in terms of both visual and numerical criteria.