• 제목/요약/키워드: Motion Artifacts

검색결과 179건 처리시간 0.027초

움직임 보상 프레임 율 변환 기법을 위한 움직임 보상 보간 프레임의 보간 오류 은닉 기법 (Interpolation Error Concealment Method of Motion Compensated Interpolated Frame for Motion Compensated Frame Rate Conversion)

  • 이정훈;한동일
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2008년도 하계종합학술대회
    • /
    • pp.927-928
    • /
    • 2008
  • In this paper, a interpolation error concealment algorithm of motion compensated interpolated frame for motion compensated frame rate conversion to reduce the block artifacts caused by failure of conventional motion estimation based on block matching algorithm is proposed. Experimental results show good performance of the proposed scheme with significant reduction of the block artifacts.

  • PDF

주변 블록의 움직임 벡터 빈도수에 기반한 움직임 벡터 교정을 적용한 프레임 율 변환 기법 (Frame Rate Up-Conversion Using the Motion Vector Correction based on Motion Vector Frequency of Neighboring blocks)

  • 이정훈;한동일
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2007년도 하계종합학술대회 논문집
    • /
    • pp.259-260
    • /
    • 2007
  • In this paper, a frame rate up-conversion algorithm using the motion vector frequency of neighboring blocks to reduce the block artifacts caused by failure of conventional motion estimation based on block matching algorithm is proposed. Experimental results show good performance of the proposed scheme with significant reduction of the erroneous motion vectors and block artifacts.

  • PDF

칼만필터와 적응필터를 기반한 PPG 동잡음 제거 필터 설계 (Design of Motion Artifacts Filter of PPG Signal based on Kalman filter and Adaptive filter)

  • 이병로;이주원
    • 한국정보통신학회논문지
    • /
    • 제18권4호
    • /
    • pp.986-991
    • /
    • 2014
  • 모바일 헬스케어와 원격진료에서 사용되는 광용적 맥파(PPG) 신호는 환자로부터 발생되는 여러 가지의 동잡음을 포함하고 있다. 이러한 동잡음을 제거하기위해 이동평균필터, 적응필터, 가속도 센서 등을 이용한 기법이 제시되었으나, 아직까지도 그 성능이 만족 스럽지 못하다. 따라서 본 연구에서는 이러한 동잡음 문제를 해결하기 위해 칼만필터와 적응필터를 이용한 새로운 동잡음 제거 기법을 제안하고 그 성능을 평가하기위해 다양한 동잡음을 사용하였다. 이 실험의 결과에서 제안된 방법의 신호대 잡음비는 이동 평균 필터 보다 4.8배인 우수한 성능을 보였다.

생체 정보 감시 장치를 위한 광변조 기법의 PPG 신호처리 (Light Modulation based on PPG Signal Processing for Biomedical Signal Monitoring Device)

  • 이한욱;이주원;정원근;김성후;이건기
    • 대한의용생체공학회:의공학회지
    • /
    • 제30권6호
    • /
    • pp.503-509
    • /
    • 2009
  • The development of technology has led to ubiquitous health care service, which enables many patients to receive medical services anytime and anywhere. For the ubiquitous health care environment, real-time measurement of biomedical signals is very important, and the medical instruments must be small and portable or wearable. So, such devices have been developed to measure biomedical signals. In this study, we develop the biomedical monitoring device which is sensing the PPG signal, one of the useful signal in the field of ubiquitous healthcare. We design a watch-like biomedical signal monitoring system without a finger probe to prevent the user's inconvenience. This system obtains the PPG from the radial artery using a sensor in the wrist band. But, new device developed in this paper is easy to get the motion artifacts. So, we proposed new algorithm removing the motion artifacts from the PPG signal. The method detects motion artifacts by changing the degree of brightness of the light source. If the brightness of the light source is reduced, the PPG pulses will disappear. When the PPG pulses have disappeared completely, the remaining signal is not the signal that results from the changing blood flow. We believe that this signal is the motion artifact and call it the noise reference signal. The motion artifacts are removed by subtracting the noise reference signal from the input signal. We apply this algorithm to the system, so we can stabilize the biomedical monitoring system we designed.

정지자막 영역의 움직임 보상 보간 기법 (Motion-Compensated Interpolation for Non-moving Caption Region)

  • 이정훈;한동일
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2007년도 하계종합학술대회 논문집
    • /
    • pp.363-364
    • /
    • 2007
  • In this paper, we present a novel motion-compensated interpolation technique for non-moving caption region to prevent the block artifacts due to the failure of conventional block-based motion estimation algorithm on the block is consist of non-moving caption and moving object. Experimental results indicate good performance of the proposed scheme with significantly reduced block artifacts on image sequence that include non-moving caption. Also the proposed method is simple and adequate for hardware implementation.

  • PDF

생명신호 측정용 반사형 광용적맥파 측정기의 움직임에 의한 신호왜곡 제거 (Development of Reflected Type Photoplethysmorgraph (PPG) Sensor with Motion Artifacts Reduction)

  • 한효녕;이연주;김정식;김정
    • 한국정밀공학회지
    • /
    • 제26권12호
    • /
    • pp.146-153
    • /
    • 2009
  • One of the most important issues in the wearable healthcare sensors is to minimize the motion artifacts in the vital signals for continuous monitoring. This paper presents a reflected type photoplethysmograph (PPG) sensor for monitoring heart rates at the artery of the wrist. Active noise cancellation algorithm was applied to compensate the distorted signals by motions with Least Mean Square (LMS) adaptive filter algorithms, using acceleration signals from a MEMS accelerometer. Experiments with a watch type PPG sensor were performed to validate the proposed algorithm during typical daily motions such as walking and running. The developed sensor is suitable for ubiquitous healthcare system and monitoring vital arterial signals during surgery.

Characterization of Motion Interpolation in 120Hz Systems

  • Shin, Byung-Hyuk;Kim, Kyung-Woo;Park, Min-Kyu;Berkeley, Brian H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.681-684
    • /
    • 2008
  • Motion interpolation is adopted and has been spread widely into market since it is effective in reducing motion blur, which is considered as weak characteristic due to slow response time of liquid crystal and hold-type display. 120Hz driving using interpolated frames achieves better moving picture quality with less motion blur and less motion judder. However, errors in the interpolated frames can cause visual artifacts such as static text breakup, halos, and occlusions. This paper focuses on categorizing characteristics of visual artifacts and on reducing side-effects by using information from original frames in special cases.

  • PDF

인덕턴스 호흡감시 시스템의 개발 (Development of Respiratory Monitoring System by Inductive Plethysmography)

  • 김덕원;연동수;김수찬
    • 대한의용생체공학회:의공학회지
    • /
    • 제16권3호
    • /
    • pp.353-358
    • /
    • 1995
  • 현재 환자의 호흡 감시를 위해 사용되고 있는 임피던스 호흡측정법(impedance pneumography)은 측정법이 간편하며 비관혈적이라는 장점등이 있으나, motion artifact에 민감하고 장애 무호흡(obstructive apnea)을 감지하는데 둔감하다는 단점이 있다. 본 연구에서 개발된 3채널 RIP(respiratory inductive plethysmograghy)는 흉부나 복주에 인덕턴스 밴드를 부착하여 호흡에 의한 단면적의 변화를 인덕턴스의 변화로 호흡을 감지하는 방법으로서 임피던스 호흡측정법에 비해 각종 motion artifact에 덜 민감하며 장애 무호흡 감자에는 민감함을 확인하였다.

  • PDF

U-헬스케어 시스템을 위한 개선된 PMAF 기반의 PPG 신호의 동잡음 제거 (Motion Artifacts reduction from the PPG based on the Improved PMAF for the U-Healthcare System)

  • 이한욱;이주원;정원근;전재철;이건기
    • 전자공학회논문지SC
    • /
    • 제45권5호
    • /
    • pp.28-34
    • /
    • 2008
  • 유비쿼터스 헬스케어 환경의 실현을 위해 실시간의 생체 정보 모니터링은 매우 중요한 요소이다. 이러한 생체 정보 모니터링을 위한 장치는 대부분 PPG 신호를 얻어 피측정자의 상태 모니터링에 활용하고 있다. PPG 신호를 얻기 위해서는 핑거프로브를 손가락에 착용해야 하기 때문에 일상생활을 하기에 불편할 뿐만 아니라, 핑거 프로브 착용자의 움직임에 의한 동잡음으로 인하여 정확한 PPG신호를 얻기가 매우 힘들다. 본 논문에서는 핑거프로브를 없앤 U-헬스케어를 위한 손목형 생체 정보 모니터링 시스템을 개발하고, 생체 정보 모니터링 시스템의 감시 요소 중 하나인 PPG 신호의 동잡음 제거를 위해 새로운 알고리즘을 제안한다. 개발한 시스템은 핑거프로브를 없앤 대신 밴드스트립에 LED와 포토센서를 장착하여 손목의 동맥혈관의 혈류 변화량으로부터 PPG를 얻도록 설계하였다. 그러나 밴드스트립에 위치한 센서는 핑거프로브에 위치한 센서에 비해 많은 동잡음에 노출되어 있으므로, 그 동잡음들을 제거하기 위하여 최근 제기된 PPG 신호의 유사 주기성을 이용한 PMAF(Periodic Moving Average Filter) 방법을 개선한 새로운 동잡음 제거 방법을 제안한다.

움직임 보상의 신뢰도에 기반 한 순차주사화 알고리즘 (De-interlacing Algorithm based on Motion Compensation Reliability)

  • 장준영;김영덕;강문기
    • 대한전자공학회논문지SP
    • /
    • 제46권6호
    • /
    • pp.102-111
    • /
    • 2009
  • 본 논문에서는 움직임 보상 결과의 신뢰도를 바탕으로 움직임 보상 순차주사화 알고리즘의 결과와 움직임 보상 수직-시간 필터의 결과를 결합하는 순차주사화 알고리즘을 제안한다. 움직임 보상 순차주사화 알고리즘은 높은 공간 해상도를 가진 고화질 영상을 생성하지만 움직임 벡터가 잘못 추정되었을 경우 눈에 띄는 에러를 발생시킨다. 반면에 움직임 보상 수직-시간 필터는 높은 공간 해상도를 제공하지는 못하지만 움직임 벡터의 에러에 강건한 특성을 가지고 있기 때문에 전체적으로 자연스러운 영상을 제공한다. 제안하는 순차주사화 알고리즘은 추정된 움직임 벡터와 움직임 보상 순차주사화 알고리즘의 결과를 분석하여 움직임 보상의 신뢰도를 추정한 후, 움직임 보상 신뢰도에 기반 한 가중치를 바탕으로 두 가지 방법의 장점을 결합한다. 제안된 방법은 움직임 보상의 신뢰도가 높은 영역에서는 높은 공간 해상도를 제공하는 움직임 보상 순차주사화 알고리즘을 적용하고 움직임 보상의 신뢰도가 낮은 영역에 대해서는 움직임 보상 수직-시간 필터를 적용하여 눈에 띄는 에러 없이 높은 공간 해상도를 가지는 영상을 생성한다. 실험 결과에서는 제안된 알고리즘이 기존의 알고리즘에 비해 시각적 및 수치적인 면에서 뛰어난 결과를 보임을 확인할 수 있다.