• Title/Summary/Keyword: Morrill Index

Search Result 4, Processing Time 0.018 seconds

CFD Simulation of the Effects of Inlet Flow rate on Hydraulic Behavior in Continuous Stirred-Tank Reactor (CSTR) (CFD 모사 기법을 이용한 유입 유량에 의한 연속 완전혼화 반응조 수리거동 고찰에 관한 연구)

  • Lee, Young Joo;Oh, Jeong Ik;Yoon, Sukmin;Kim, Jong-Oh;Park, No-Suk
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.1
    • /
    • pp.25-33
    • /
    • 2016
  • This paper describes three-dimensional computational fluid dynamics (CFD) simulation of liquid-liquid flow and transient tracer tests in a full-scale continuous stirred-tank reactor (CSTR) used for drinking water treatment. To evaluate the effects of inlet flow rate on hydrodynamic behavior in the selected CSTR, inlet flow rate was changed from 10% to 100% of the design flow rate. From the results of CFD simulation and analysis, as the inlet flow rate increases, Modal index and ${\beta}$ value are increased. Also, Morrill index shows local minimal points in relation to the inlet flow rate, which are observed at 20% and 40% of the design flow. As inlet flow Increases more than 40%, it is shown that Morrill index re-increases to close to ideal CSTR.

Study on performance improved design of pressure-type ozone contactor in multistorey water treatment plant by CFD (CFD에 의한 수직형 정수처리 실증시설 내 압력식 오존접촉조 성능개선에 관한 연구)

  • Choi, Jong-Woong;Kim, Seong-Su;Kim, Jeong-Hyun;Kim, Kwanyeop
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.4
    • /
    • pp.431-440
    • /
    • 2014
  • The ozonation process has been widely used for drinking water disinfection around the world. Recently, the pressurized ozone contactor, in which the side stream typed ozone injection method is installed, has been applied to water treatment system. In this study, numerical calculations were conducted to compare prototype and screw-type ozone contactors based on hydraulic effectiveness in more details. The prototype ozone contactor was already installed and operated in domestic water treatment plant, and the screw-type is the suggested one for improving ozone contact efficiency installing the screw plate to the prototype. Screw turn numbers of screw plate were changed as 3, 5, 7 and 9, respectively for numerical simulation. The CT(concentration of disinfectant in mg/L times time in minutes) value was considered as one of the options for evaluating disinfection ability. From the results, it could be concluded that the performance of the screw-type is higher than that of the protype contactor by controlling the variable T as the tracer time. Also, Morill index of the screw-type(turn numbers = 5 ) appeared to be lower than the other.

The Effect of Fluid Flow on Power Density in a Horizontal-flow Microbial Fuel Cell (수평 흐름형 미생물 연료전지에서 유체의 흐름 형태에 따른 전력수율 평가)

  • Lee, Chae-Young;Park, Su-Hee;Song, Young-Chae;Yoo, Kyu-Seon;Chung, Jae-Woo;Han, Sun-Kee
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.21 no.1
    • /
    • pp.39-44
    • /
    • 2013
  • This study evaluated the effect of fluid flow on the power density in a horizontal-flow microbial fuel cell (MFC). The maximum power densities in four types of flow induced by different channel types in the anode chamber were investigated. The fluid flow at each channel was analyzed using tracer tests. Results of polarization curves showed that the maximum power densities of case 1, 2, 3 and 4 were 95.7, 129.1, 190.9 and 114.2 mW/m2, respectively. Case 3 with a set of guide walls where flow had an S type-like shape showed the highest power density. Based on the Morrill Dispersion Index (MDI) value of case 4, microbial activity would be enhanced since the reactor allows even distribution of substrate but the overflow occurrence would not guarantee stable performance. Therefore, case 3 could be an effective reactor type for MFC because of high electricity generation and stable performance.

A Study on Prediction of Sedimentation Efficiency for Sedimentation Basin using Lagrangian Method (침전지의 유동 특성과 Lagrangian Method를 이용한 침전효율 예측에 관한 연구)

  • Choi, Jong-Woong;Hong, Sung-Taek;Kim, Seong-Su;Kim, Youn-Kwon;Park, No-Suk
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.5
    • /
    • pp.229-236
    • /
    • 2017
  • Flow characteristics analysis and tracer test simulations for the rectangular typed sedimentation basins, which have been operated at D_water treatment plant in Korea, were carried out using CFD (Computational Fluid Dynamics) techniques for design ($15,864m^3/day$) and operation flowrate ($33,333m^3/day$). Also, each efficiency of the sedimentation basin was evaluated by application of the Lagrangin technique on the assumption of the particles flowing into the inlet of the sedimentation basin. From the results of simulation, the mean velocity values for making the flow in the settling basin as a plug flow region were derived as 0.00193 m/s and 0.00417 m/s, respectively. In addition, ${\beta}$ (effective contact factor) values were calculated to be 0.51 and 0.46, and the Morrill Index values were 6.05 and 3.21, respectively for both flowrate conditions.