• Title/Summary/Keyword: Morphological measuring

Search Result 129, Processing Time 0.025 seconds

A Study on System for measuring morphometric characteristis of fish using morphological image processing (형태학적 영상처리를 이용한 어체 측정 시스템 개발에 관한 연구)

  • Lee, Dong-Gil;Yang, Yong-Su;Kim, SeongHun;Choi, Jung-Hwa;Kang, Jun-Gu;Kim, Hee-Je
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.48 no.4
    • /
    • pp.469-478
    • /
    • 2012
  • To manage, sort, and grade fishery resources, it is necessary to measure their morphometric characteristics. This labor-intensive task involves performing repetitive operations on land and on a research vessel. To reduce the amount of labor required, a vision-based automatic measurement system (VAMS) for the measurement of morphometric characteristics of flatfish, such as total length (TL), body width (BW), and body height (BH), has been developed as part of a database management system for fishery resources management. This system can also measure the mass (M) of flatfish. In the present study, we describe a morphological image processing algorithm for the measurement of certain characteristics of flatfish. This algorithm, which involves preprocessing, edge pattern matching, and edge point detection, is effective in cases where the flatfish being measured has a deformed tail and is randomly oriented. The satisfactory performance of the proposed algorithm is also demonstrated by means of experiments involving the measurement of the BW, TL and BH of a flatfish when it is straightened (BW : 117mm, TL : 329mm, BH : 24.5mm), when its tail is deformed, and when it is randomly oriented.

Strain relaxed Co nanocrystals formation from thin films on sapphire substrate induced by nano-second laser irradiation

  • Seo, Ok-Gyun;Gang, Deok-Ho;Son, Jun-Gon;Choe, Jeong-Won;Ha, Seong-Su;Kim, Seon-Min;Gang, Hyeon-Cheol;No, Do-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.145.2-145.2
    • /
    • 2016
  • We report the phase transformation of Co thin films on a sapphire substrate induced by laser irradiation. As grown Co films were initially strained and tetragonally distorted. With low power laser irradiation, the surface was ruptured and irregular holes were formed. As the laser power was increased, the films changed into round shape Co nanocrystals with well-defined 6-fold structure. By measuring the XRD of Co nanostructure as a function of laser energy densities, we found that the change of morphological shapes from films to nanocrystals was accompanied with decrease of the tetragonal distortion as well as strain relaxation. By measuring the size distribution of nanocrystals as a function of film thickness, the average diameter is proportional to 1.7 power of the film thickness which was consistent with the prediction of thin film hydrodynamic (TFT) dwetting theory. Finally, we fabricated the formation of size controlling nanocrystals on the sapphire substrate without strain.

  • PDF

Design of Noninvasive Arterial Blood Pressure Measurement System by Using Double-Cuffs Oscillometric Method (이중 커프 오실로메트릭법을 이용한 비침습 동맥압 측정시스템의 설계)

  • Lee, Pil-Jae;Lee, Young-Jae;Kim, Dong-Jun;Lee, Jae-Ho;Lim, Min-Gyu;Lee, Jeong-Whan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.6
    • /
    • pp.885-890
    • /
    • 2012
  • In this study, a new blood pressure measuring system was proposed and implemented. An additional small-cuff was placed on the center of a inner cuff to measure morphological signals and new oscillometric ratio. The proposed BP-measuring system is composed of an external cuff, an inner cuff and a small-cuff. Oscillation signal from small-cuff is interpolated with 7th-order fitting polynomials and SBP, DBP ratio were 22.2% and 87.7%. Experimental data were gathered from 20 volunteers ($25{\pm}4$ years) and arterial blood pressure values were compared with auscultation, sphygmomanometers, small-cuff and inner-cuff. As a result, the difference in systolic BP between auscultation and the small-cuff was 1.93(${\pm}1.28$) mmHg, and the inner-cuff was 4.53(${\pm}4.39$) mmHg, and sphygmomanometer was 6.68(${\pm}3.99$) mmHg, and the corresponding difference in diastolic BP was 2.50(${\pm}2.04$) mmHg, 3.50(${\pm}3.19$) mmHg, 7.35(${\pm}5.62$), respectively.

Hemocyte Types in Adult Grasshpper, Euprepocnemis shirakii Bolivar (메뚜기 (Euprepocnemis shirakii) 성충의 혈구유형)

  • Chang, Byung-Soo;Han, Sung-Sik;Yoe, Sung-Moon
    • Applied Microscopy
    • /
    • v.24 no.2
    • /
    • pp.93-104
    • /
    • 1994
  • Six types of hemocytes were identified in adult grasshopper, Euprepocnemis shirakii Bolivar. The morphological and ultrastructural characteristics of these cells were characterized by phase contrast, scanning and transmission electron microscope. The prohemocytes are small and spherical cells with large nucleus. The plasmatocytes are spindle shaped or polymorphic cells which show numerous cytoplasmic processes on the cell surface and they have lysosomes and vesicles that may be involved in phagocytic function. Especially, multivesicular bodies are observed in the polymorphic cells. The granulocytes I are spherical shaped cells. They are characterized by a number of electron dense granules measuring $0.2-0.3{\mu}m$ in average diameter and marginal band of microtubules which are always in close proximity to the cell membrane. The granulocytes II are oval or spindle-shaped cells. They contain large electron dense granules measuring $0.5-0.8{\mu}m$ in average diameter. Their cytoplasm is filled with numerous granules. The spherulocytes contain large amounts of spherules that most of their cytoplasm. Spherules filled with fine granules or flocculent materials. The oenocytoids are large spherical cells with few cytoplasmic organelles. Their cytoplasm contains peculiar aspect of motochondria and numerous polyrobosome.

  • PDF

Study of Refining Effects on Pulp Fibre by Scanning Probe Microscopy(SPM) (Scanning Probe Microscopy를 이용한 고해 효과 연구)

  • ;Keity Roy Wadhams
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.30 no.4
    • /
    • pp.49-58
    • /
    • 1998
  • The SPM could image the most detailed microstructure of a sample in a wet and dry state by measuring the interaction between the atoms on the sample surface and the extremely sharp probe tip. The refined fibre exhibited large wrinkles formed by fibrillar bundles, the disintegrated fibres extensively showed “scale-like features”. By using the Non-Contact Atomic Force Microscopy (NC-AFM) and Contact Atomic Force Microscopy (C-AFM) including Phase Detection Microscopy (PDM) and Force Modulation Microscopy (FMM), it was possible to investigate surface topography, surface roughness and mechanical property (hardness or visco-elasticity) of fibre surface in detail. The PDM and FMM images showed that the disintegrated only fibre displayed uniform mechanical properties, whereas the refined one did not. The surface roughness of pulp fibres was higher in refined fibres than in disintegrated fibres due to the presence of external fibrils. These SPM images would be used to provide visual evidence of morphological change of a single fibre created during mechanical treatments such as refining, drying, calendering and so on.

  • PDF

Failure Mode Analysis for Polymer EL Blue Devices' Lifetime

  • Kim, Mu-Gyeom;Kim, Sang-Yeol;Lee, Tae-Woo;Park, Sang-Hun;Park, Ju-Cheol;Park, Jong-Jin;Pu, Lyong-Sun
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.1432-1435
    • /
    • 2005
  • We report failure mode observed in polymer EL blue devices, relating with life curve. The modes are analyzed by observing compositional and morphological variation using TEM-EDX, STM, and reverse engineering method as destructive ways, and also investigated mobility changes of hole and electron by measuring transient EL as a nondestructive way corresponding to life curve. We believe that the postulated failure modes in polymer EL devices can present right directions to obtain better performance, especially life time, of polymer devices in material and device structural designing points of view.

  • PDF

Analysis of Corneal Topography in Keratoconus (원추각막의 각막지형도 분석)

  • Kim, Douk-Hoon
    • Journal of Korean Clinical Health Science
    • /
    • v.4 no.3
    • /
    • pp.652-661
    • /
    • 2016
  • The analysis of cornea morphology using corneal topographers is a clinical practice for the diagnosis of keratoconus in contact lens fitting. The recently technique has developed with the possibility of achieving a great number of measuring points of both anterior and posterior corneal surfaces in cornea. Also these data are used to extract a series of topographic valuation indices that permit to offer the most exact clinical diagnosis of keratoconus in contact lens fitting. This study describes the technologies in which current corneal topographers are based on the morphological characteristics that the keratoconus status observe on corneal surface. Therefore, this paper can provide that the analysis of corneal topographers applied for the diagnosis of keratoconus in contact lens fitting.

Development of Separation Algorithm of Overlapped Particles in Spay Flow (분무 유동에서 중첩 인자 분리 알고리즘의 개발)

  • Yang, C.J.;Kim, J.H.;Cho, D.H.;Oh, J.H.;Lee, Y.H.
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.118-119
    • /
    • 2005
  • Recently, fire extinguishing systems based on water mists have been attracting public attentions in marine engineering. Performance of the fire extinguishing systems is influenced by the size and distribution of spayed water mists. Droplet analyzing method based on image processing technique for measuring droplet size and distribution has been developed. The morphological method based on partial curvature information of pre-processed images was adopted for recognition and separation of overlapped particles. Tested results show that the present method may be reliable for the analysis of the size and distribution of droplets produced by water mist spay flow.

  • PDF

선박용 미분무 소화기노즐 수적 입자경 계측기법 개발

  • Kim, Tae-Hyeong;Kim, Jeong-Hwan;Yang, Chang-Jo;O, Jong-Hwan;Choe, Jang-Un
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.307-308
    • /
    • 2006
  • Recently, fire extinguishing systems based on water mists have been attracting public attentions in marine engineering. Performance of the fire extinguishing systems is influenced by the size and distribution of spayed water mists. Droplet analyzing method based on image processing technique for measuring droplet size and distribution has been developed. The morphological method based on partial curvature information of pre-processed images was adopted for recognition and separation of overlapped particles. Tested results show that the present method may be reliable for the analysis of the size and distribution of droplets produced by water mist spay flow.

  • PDF

Predict of Fracture Risk Rate According to Morphological Measuring of Proximal Femoral Part Using Dual Energy X-ray Absoptiometry (이중에너지 X선 흡수계측법을 이용한 대퇴골 근위부의 형태학적 측정에 따른 골절 위험도의 예측)

  • Yoon, Han-Sik
    • Journal of radiological science and technology
    • /
    • v.25 no.1
    • /
    • pp.49-53
    • /
    • 2002
  • The femoral fracture is the most serious problem of old ages haying osteoporotic fractures. First of all, prevention to reduce the incidence of hip fracture and to identify the risk factor is essential subject. The purpose of this study is to investigate which geometric parameters of proximal femur are related to the hip fracture risk in old ages. Author analyzed the bone density and bone content of over 60 years old women who had suffered hip fracture (n=60) and non fracture groups (n=60). Author concluded that geometric measurements of proximal femoral part made on dual energy x-ray absorptiometry can predict hip fracture independently of bone mineral density.

  • PDF