• Title/Summary/Keyword: Morning

Search Result 1,241, Processing Time 0.025 seconds

Effects of Tropical Night and Light Pollution on Cicadas Calls in Urban Areas (도심지 열대야 및 빛공해에 의한 매미 울음 영향)

  • Ki, Kyong-Seok;Gim, Ji-youn;Yoon, Ki-Sang;Lee, Jae-Yoon
    • Korean Journal of Environment and Ecology
    • /
    • v.30 no.4
    • /
    • pp.724-729
    • /
    • 2016
  • Environmental factors that affect the singing of cicadas have not been studied extensively, especially those affecting the cicadas' singing during the nighttime. Therefore, the objective of this study is to identify the effects of tropical night and light pollution on the cicadas' singing in a downtown area. The study sites were an apartment complex in Seocho-gu, Seoul, and the Chiaksan National Park in Wonju-si. The study subjects were Hyalessa fuscata and Cryptotympana atrata, which are the dominant species in Korea during summer. Cicada songs were recorded 24 hours a day, every day. The recording period was between July and August, lasting 25 days at the Seoul site and 14 days at the Chiaksan National Park. Temperature, precipitation, humidity, and amount of sunshine were selected as the environmental factors that potentially affect the cicadas' singing. Statistical analyses included correlations of meteorological factors with the cicadas' singing per hour, per 24 hours, and at nighttime (21:00~04:00). The results showed that: 1) H. fuscata began singing during the dawn hours, and the singing increased in intensity early in the morning. C. atrata's singing reached its peak in the morning and afternoon, ceased during sunset hours, thereby exhibiting a difference in the singing pattern of the two species. 2) The frequency of singing by H. fuscata decreased when C. atrata began to sing intensively in numbers, thereby exhibiting interspecific influence. 3) The results of the correlation analysis between meteorological factors and the singing of H. fuscata and C. atrata showed that both species tended to sing more when the temperature was higher and sang less on rainy days. 4) When limited to nighttime only, C. atrata showed a tendency of singing when the nighttime temperature was high ($24-30^{\circ}C$, average $27^{\circ}C$), whereas H. fuscata did not show a correlation with meteorological factors. However, since H. fuscata sang during the night in areas with artificial lighting, it was concluded that its singing was due to light pollution.

Exposure Assessment to Particulates and Noise among Sculptors at a College of Fine Art (미술대학 조소작업 중 발생하는 분진 및 소음에 대한 노출평가)

  • Cho, Hyun-Woo;Yoon, Chung-Sik;Ham, Seung-Hon;Lee, Lim-Kyu;Park, Ji-Hoon;Park, Dong-Jin;Chung, Jin-Ho;Yeom, Jong-Soo;Seo, Kyu-Jin
    • Journal of Environmental Health Sciences
    • /
    • v.37 no.4
    • /
    • pp.267-278
    • /
    • 2011
  • Objectives: A great number of hazardous agents can be emitted from various types of art-creation in a fine arts college, but little data on exposure assessment has been published. A variety of processes encompassing toxic or non-toxic materials, tools, and components are involved in a sculptor work at a fine art college. The aim of this study was to assess exposure levels to particulates and noise during sculpture classes in a college of fine arts. Methods: Students in sculpture classes participated in this study. Mass, number, and surface area concentrations of particulates, noise level, temperature and relative humidity were monitored by both personal and area sampling during the tasks of metal, wood, and stone sculpting. Results: The number and surface concentration of particulates was the highest in the task of wood sculpting, followed by metal and stone work. The mass concentration of particulates was the highest in stone sculpting (personal GM 3.0 mg/$m^3$, GSD 3.0), followed by wood (personal GM 1.5 mg/$m^3$, GSD 1.8) and metal work (personal GM 0.95 mg/$m^3$, GSD 1.51) in that order. Occupational exposure limits (OEL) for particulates depends on the type of particulate. For wood dust, 86% (six subjects) of the personal samples and all area samples exceeded the Korean OEL for wood dust (1 mg/$m^3$), while 20% (two subjects) among stone sculpting students were exposed above the Korean OEL (10 mg/$m^3$). In contrast, metal sculpting did not exceed the OEL (5 mg/$m^3$). For noise level, metal sculpting students (Leq 95.1 dB(A) in the morning, 85.3 dB(A) in the afternoon) were exposed the most, followed by stone sculpting (88.3 dB(A)), and wood sculpting (84.8 dB(A)) in that order. Compared with the 90 dB(A) of the Korean OEL and 85 dB(A) of the American Conference of Governmental Industrial Hygienists' threshold limit value (ACGIH-TLV) for noise, 100% of the subjects (five subjects) and area samples during metal sculpting in the morning session exceeded both OELs, but only three subjects (60%) exceeded the ACGIH-TLV in the afternoon session. For stone sculpting, 50% (one subject) and 100% (two subjects) exceeded the Korean OEL and ACGIH-TLV, respectively, but the area sample did not exceed either OEL. During wood sculpting, two subjects (40%) exceeded ACGIH TLV. Conclusions: This work evaluated the sculptors' exposure to particulate matter and noise in fine art college, and revealed a poor working environment for the participating students. Effective measures should be supplemented by the administration of colleges.

Prediction of Concrete Temperature and Its Effects on Continuously Reinforcement Concrete Pavement Behavior at Early Ages (초기재령에서 연속철근콘크리트포장 거동에 콘크리트 온도의 영향과 예측)

  • Kim Dong-Ho;Choi Seong-Cheol;Won Moon-Cheol
    • International Journal of Highway Engineering
    • /
    • v.8 no.2 s.28
    • /
    • pp.55-62
    • /
    • 2006
  • Transverse cracks in continuously reinforced concrete pavement (CRCP) occur at early ages due to temperature and moisture variations. The width and spacing of transverse cracks have a significant effect on pavement performance such as load transfer efficiency and punchout development. Also, crack widths in CRCP depend on 'zero-stress temperature,' which is defined as a temperature where initial concrete stresses become zero, as well as drying shrinkage of concrete. For good long-term performance of CRCP, transverse cracks need to be kept tight. To keep the crack widths tight throughout the pavement life, zero-stress temperature must be as low as practically possible. Thus, temperature control at early ages is a key component In ensuring good CRCP performance. In this study, concrete temperatures were predicted using PavePro, a concrete temperature prediction program, for a CRCP construction project, and those values were compared with actual measured temperatures obtained from field testing. The cracks were also surveyed for 12 days after concrete placement. Findings from this study can be summarized as follows. First, the actual maximum temperatures are greater than the predicted maximum temperature in the ranges of 0.2 to 4.5$^{\circ}C$. For accurate temperature predictions, hydration properties of cementitious materials such as activation energy and adiabatic constants, should be evaluated and accurate values be obtained for use as input values. Second, within 24 hours of concrete placement, temperatures of concrete placed in the morning are higher than those placed in the afternoon, and the maximum concrete temperature occurred in the concrete placed at noon. Finally, from the 12 days of condition survey, it was noted that the rate of crack occurrence in the morning placed section was 25 percent greater than that in the afternoon placed section. Based on these findings, it is concluded that maximum concrete temperature has a significant effect on crack development, and boner concrete temperature control is needed to ensure adequate CRCP performance.

  • PDF

Estimating Precise Spatio-Temporal Distribution of Weather Condition Using Semi-Variogram in Small Scale Recreation Forest (Semi-Variogram을 이용한 소규모 자연휴양림 내기상조건의 정밀 시공간 분포 추정)

  • LIM, Chul-Hee;RYU, Dong-Hoon;SONG, Chol-Ho;ZHU, Yong-Yan;LEE, Woo-Kyun;KIM, Min-Seon
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.18 no.3
    • /
    • pp.63-75
    • /
    • 2015
  • As forest therapy is getting more attention than ever, it is important to organize time for activity and location based on spatio-temporal distribution of weather condition in forest. This study aimed to analyze precise spatio-temporal distribution of weather condition by installing long-term weather monitoring device in Yonghyun national natural recreation forest and using acquired weather data in order to support forest recreation and therapy activity. First, we statistically compared 4 models of semi-variogram and the results were all similar. We selected and analyzed the circular model for this study because it was presumed to be the best model for this case. We derived 128 results from the circular model and through semi-variogram, we identified seasonal and temporal distributions of temperature and humidity. Then, we used boxplot, made of partial sill level, to identify significant differences in seasonal and temporal distributions. As a result, in spring and early morning, both temperature and humidity showed equalized result. On the other hand, in summer and early afternoon, both temperature and humidity showed uneven result. In spring and early morning, changes in weather condition are shown little from spatial shifting, it is ideal to perform recreational activities and forest therapy but in summer and early afternoon, it is unadvisable to do so as the changes in weather condition could be harmful unless any other means of preparations are made. This study proposes its significance by analyzing seasonal micro-weather of single recreation forest and presenting seasonal and temporal outcomes.

Clinical Characteristics and Prognosis of Fuchs Dystrophy According to COL8A2 Gene Mutation Status (COL8A2 유전자 돌연변이 유무에 따른 푹스이상증의 임상적 특징 및 예후)

  • Kim, Hyun-Ah;Whang, Woong-Joo;Lee, Jee Hye;Chae, Hyojin;Kim, Myungshin;Kim, Man Soo
    • Journal of The Korean Ophthalmological Society
    • /
    • v.58 no.4
    • /
    • pp.380-386
    • /
    • 2017
  • Purpose: To compare the clinical characteristics and prognosis of Fuchs dystrophy patients according to COL8A2 gene mutation status. Methods: Eighty-one patients (162 eyes) initially diagnosed with Fuchs dystrophy from 1996 to 2015 were divided into two groups according to COL8A2 gene mutation status. Retrospective analysis was performed comparing gender, age at diagnosis, presence of family history, diabetes mellitus, symptoms of blurred vision in the morning, changes in central corneal thickness and endothelial cell density with time, need for corneal transplantation, and pre-operative corneal status in the two groups. Results: Of the 81 patients, 12 were shown to harbor a COL8A2 gene mutation. Individuals with mutation were significantly associated with presence of family history, diabetes mellitus, and blurred vision in the morning (p = 0.021, p = 0.024, p = 0.044, respectively). They also had significantly thicker central cornea and lower endothelial cell density at the time of diagnosis (p = 0.020, p = 0.005, respectively). The differences in central corneal thickness and endothelial cell density between the two eyes in one patient were significantly smaller in patients with gene mutation (p = 0.043, p = 0.022, respectively). Over a 5-year follow-up period, 60.0% of eyes in patients with gene mutation and 19.2% of eyes in patients without gene mutation underwent corneal transplantation, a significant difference between the two groups (p = 0.014). Conclusions: By testing for COL8A2 gene mutation, early binocular disease progression and the possible need for corneal transplantation in the future can be predicted among patients diagnosed with Fuchs dystrophy.

Comparison of Reflectance and Vegetation Index Changes by Type of UAV-Mounted Multi-Spectral Sensors (무인비행체 탑재 다중분광 센서별 반사율 및 식생지수 변화 비교)

  • Lee, Kyung-do;Ahn, Ho-yong;Ryu, Jae-hyun;So, Kyu-ho;Na, Sang-il
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.5_1
    • /
    • pp.947-958
    • /
    • 2021
  • This study was conducted to provide basic data for crop monitoring by comparing and analyzing changes in reflectance and vegetation index by sensor of multi-spectral sensors mounted on unmanned aerial vehicles. For four types of unmanned aerial vehicle-mounted multispectral sensors, such as RedEdge-MX, S110 NIR, Sequioa, and P4M, on September 14 and September 15, 2020, aerial images were taken, once in the morning and in the afternoon, a total of 4 times, and reflectance and vegetation index were calculated and compared. In the case of reflectance, the time-series coefficient of variation of all sensors showed an average value of about 10% or more, indicating that there is a limit to its use. The coefficient of variation of the vegetation index by sensor for the crop test group showed an average value of 1.2 to 3.6% in the crop experimental sites with high vitality due to thick vegetation, showing variability within 5%. However, this was a higher value than the coefficient of variation on a clear day, and it is estimated that the weather conditions such as clouds were different in the morning and afternoon during the experiment period. It is thought that it is necessary to establish and implement a UAV flight plan. As a result of comparing the NDVI between the multi-spectral sensors of the unmanned aerial vehicle, in this experiment, it is thought that the RedEdeg-MX sensor can be used together without special correction of the NDVI value even if several sensors of the same type are used in a stable light environment. RedEdge-MX, P4M, and Sequioa sensors showed a linear relationship with each other, but supplementary experiments are needed to evaluate joint utilization through off-set correction between vegetation indices.

Vertical Profiles of CO2 Concentrations and CO2 Storage in Temperate Forest in Korea (한국 활엽수림의 이산화탄소 농도의 연직구조와 저류항)

  • Thakuri, Bindu Malla;Kang, Minseok;Chun, Jung Hwa;Kim, Joon
    • Proceedings of The Korean Society of Agricultural and Forest Meteorology Conference
    • /
    • 2013.11a
    • /
    • pp.23-24
    • /
    • 2013
  • Micrometeorological fluxes measured over a tall forest in a complex terrain are difficult to interpret. $CO_2$ storage often makes significant contributions to net ecosystem exchange of $CO_2$ (NEE) in early morning and during nighttime due to calm and stable conditions. We measured the above-canopy $CO_2$ flux along with its concentration profiles at eight levels within and above the canopy to evaluate $CO_2$ storage term. Our question is whether or not the $CO_2$ storage term can be estimated accurately from a single level measurement of $CO_2$ concentration in a complex terrain. Our objectives are (1) to document vertical profiles of $CO_2$ concentration and (2) to compare the diurnal and seasonal variations of $CO_2$ storages estimated from single and multi-level $CO_2$ concentration data. Seasonally averaged Diurnal variations of $CO_2$ concentration ranged from 398 to 455 ppm near the forest floor at 0.1 m whereas they ranged from 364 to 395 ppm at 40 m in the atmosphere. The diurnal variation of vertical profiles of $CO_2$ concentration shows very interesting features with season. At all eight levels, diurnal variation of $CO_2$ concentration showed little change in winter. In spring, the diurnal variations of $CO_2$ concentration at 8 levels showed three distinct groups of layers with height: the first layer: 0.1m (near surface), second layer: 1.0 m and 4.0m (below canopy) and the third layer: 7.4m to 40.7 m (near canopy and above). In summer, these three groups of layers were further separated with larger variations whereas such distinction became smaller in fall. The diurnal variation of $CO_2$ concentration in the first three layers near surface always showed higher concentration with larger variability. Typically, $CO_2$ concentration showed peaks in early morning and in the evening. After the evening peak, $CO_2$ concentration gradually increased except for those near the surface (i.e., 0.1, 1.0 and 4.0 m) where the concentrations actually decreased. We suspect that this could be attributed to the drainage flow of $CO_2$ along the hill slope from the headwater to downstream, which is not taken into account for net ecosystem $CO_2$ exchange. In comparison to the results of other studies, the distinct and different vertical structures of $CO_2$ concentrations observed at our site may be due to complex terrain and weak turbulent mixing under calm conditions at the site. The annual mean of diurnal variation of $CO_2$ storage flux from single level ranged from -0.6 to $0.9{\mu}mol\;m^{-2}s^{-1}$ and from multi-level from -1.2 to $1.0{\mu}\;{\mu}mol\;m^{-2}s^{-1}$. When compared against the results from the multi-level concentrations, the storage flux estimated from a single-level concentration was generally adequate except for specific hours near sunrise and sunset. Further details and their implication will be discussed in the presentation.

  • PDF

Winter Indoor Thermal Environment Status of Nursery Rooms in Workplace Daycare Centers in Jeju Island (제주지역 직장어린이집 보육실의 겨울철 실내온열환경 실태)

  • Kim, Bong-Ae;Ko, Youn-Suk
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.33 no.12
    • /
    • pp.81-90
    • /
    • 2017
  • This study was conducted to investigate the thermal environment status of nursery rooms in workplace daycare centers in Jeju and propose measures to improve their indoor physical thermal environment. For this purpose, measurements were performed in the winter indoor physical environment of 51 nursery rooms in 11 workplace daycare centers and a psychological evaluation survey on the thermal environment of nursery rooms was conducted for 70 nursery teachers. The investigation was carried out over 11 days in January 2017. The results are as follow. The average indoor temperature of the nursery rooms was $21.3^{\circ}C$($18.7-23.8^{\circ}C$) and the indoor temperatures of 47 nursery rooms (92.9%) were higher than the environmental hygiene management standard for domestic school facilities ($18-20^{\circ}C$). The average relative humidity was 33.9% (16.4-56.0%), and 37 nursery rooms (86.3%) showed a lower average relative humidity than the standard (40-70%). The average absolute humidity was $9.1g/m^3$ ($4.7-13.6g/m^3$), which was lower than the standard for preventing influenza ($10g/m^3$). When the indoor temperature and humidity of the nursery rooms were compared with international standards, it was found that 85% or more of the 51 nursery rooms maintained appropriate indoor temperatures, but 40-50% of the nursery rooms maintained a low humidity condition. Therefore, they need to pay attention to maintaining the appropriate humidity of the nursery room to keep the children healthy. The average indoor temperature of the nursery rooms showed a weak negative correlation with the average relative humidity. The indoor temperature had a significant effect on the relative humidity: a higher indoor temperature resulted in lower relative humidity. Regarding the fluctuations in the average indoor temperature of the nursery rooms during the day, in daycare centers that used floor heating, the indoor temperature gradually increased form the morning to the afternoon and tended to decrease during lunch time and the morning and afternoon snack times, due to ventilation. The daycare centers that used both floor heating and ceiling-type air conditioners showed a higher indoor temperature and greater fluctuations in temperature compared to the daycare centers that used floor heating only. In the survey results, the average value of the whole body thermal sensation was 3.0 (neutral): 32 respondents (62.7%) answered, "Neutral", Which was the largest number, followed by 21 respondents (30%) who answered, "Slightly hot" and 17 respondents (24.2%) who answered, "Slightly cold." Twenty-nine respondents answered, "Slightly dry," which was the largest number, followed by 28 respondents (54.9%) who answered, "Neutral" and 10 respondents (19.6%) who answered, "Dry." The total number of respondents who answered, "Slightly dry" or "Dry" was large at 39 (56.4%), which suggests the need for indoor environment management to prevent a low-humidity environment. To summarize the above results about the thermal environment of nursery rooms, as the indoor temperature increased, the relative humidity decreased. This suggests the effect of room temperature on the indoor relative humidity; however, frequent ventilations also greatly decrease the relative humidity. Therefore, the ventilation method and the usage of air conditioning systems need to be re-examined.

Searching for Rotationable Vegetables for Paratylenchus projectus in Lettuce Greenhouse (해바라기침선충(Paratylenchus projectus) 피해 경감을 위한 윤작작물 탐색)

  • Kwon, Giyoon;Seo, Jongmin;Park, Sohee;Kang, Heonil;Park, Namsook;Choi, Insoo
    • Research in Plant Disease
    • /
    • v.26 no.4
    • /
    • pp.272-278
    • /
    • 2020
  • The severe lettuce damage caused by Paratylenchus projectus was first reported in 2019 in Korea. To find high-value rotation crops for the control of P. projectus, nine vegetables, Brassica juncea (leaf mustard), B. rapa subsp. nipposinica (kyona), B. oleracea var. italica (broccoli), B. rapa subsp. chinensis (bok choy), B. oleracea var. viridis (kale), B. oleracea var. gongylodes (kohlrabi), Cichorium endivia (endive), C. intybus (chicory), Ipomoea aquatica (morning glory) were planted in d-10-cm clay pots in greenhouse. The growth of vegetables was compared between inoculated with 3,000 P. projectus per 100 ㎤ of soil and non-inoculated. Treatments were replicated 10 times. After 100 days, the reduction of fresh top weight was 30.4% in C. intybus, 35.1% in I. aquatica, 36.9% in B. oleracea var. acephala, 40.5% in C. endivia, 42.1% in B. rapa, 47.5% in B. rapa subsp. nipposinica, 50.4% in B. oleracea var. gonglodes, 56.3% in B. oleracea var. italica, and 66.0% in B. juncea. Nematode multiplication rates (Pf/Pi) were lower in I. aquatica (0.64) and C. endivia (1.1), but higher in B. oleracea var. gongylodes (2.54). Considering these results, I. aquatica is suitable for the rotation crop with lettuce until better rotation crops developed.

Characteristics of Cooling Effect Depending on Operation of Forced Ventilation Systems in a Single-span Plastic Greenhouse (강제환기장치 사용에 따른 단동 플라스틱 온실 기온 강하 특성)

  • Kim, Seong-Heon;Kim, Hyung-Kweon;Kwon, Jin-Kyung;Lee, Si-Young
    • Journal of Bio-Environment Control
    • /
    • v.31 no.3
    • /
    • pp.143-151
    • /
    • 2022
  • This study was carried out to investigate quantitative characteristics of the cooling effect in a single-span arch greenhouse with roll-up side vents depending on operation of circulation and exhaust fans during ventilation, in order to suggest a practical strategy regarding installation or operation of forced ventilation systems. The examination was conducted under 3 different ventilation conditions (side vents only, side vents + circulation fans, and side vents + circulation fans + exhaust fans). In each condition, variations of internal and external air temperatures and exogenous environmental factors were recorded during ventilation, and the cooling effects were investigated by comparing the normalized temperature difference (NTD) of each ventilation condition. In the morning time (11:00-12:00), a temporary peak in the temperature difference was observed at the beginning of ventilation regardless of ventilation methods. The time taken to the maximum NTD was decreased from 340 s to 110s, and the NTD was dropped from 1.158 to 1.037 as the more forced ventilation systems were operated. The more operations caused the passing time over specific NTD values reduced by 60% as the time was reduced from 1,030 s to 550 s at NTD = 0.8, 1,610 s to 915 s at NTD = 0.6, and 2,315 s to 1,360 s at NTD = 0.4. The temporary peak in NTD was not observed in the afternoon time (14:00-15:00) but it was dropped as quickly as the ventilation started. Also the more operations resulted in the passing time over specific NTD values reduced by 70% as the time was reduced from 560 s to 345 s at NTD = 0.8, from 825 s to 540 s at NTD = 0.6, and from 1,145 s to 810 s at NTD = 0.4. Conclusively, the intervention of the forced ventilation system is recommended in the morning time or in high thermal conditions to achieve more effective and economical ventilation.