• Title/Summary/Keyword: Moon pool

Search Result 102, Processing Time 0.028 seconds

Evaluation of Gas Metal Arc Welding Characteristics according to Contact Tip Materials (GMA용접에서 콘택트 팁 재질에 따른 용접특성 평가)

  • Kim, Dong Yoon;Hwang, In Sung;Kim, Dong Cheol;Kang, Moon Jin
    • Journal of Welding and Joining
    • /
    • v.32 no.6
    • /
    • pp.35-40
    • /
    • 2014
  • The contact tip for gas metal arc welding has important functions to transmit the welding current to the wire and to guide the wire to molten pool. If the contact tip is damaged, it is a cause of lowering the welding productivity due to removal of welding defects and replacement of contact tip. In case of the use of a contact tip for a long time the arc is unstable because the processed hole in the contact tip center is larger, and the variation of aiming position of the welding wire causes a seam tracking error. In this study, gas metal arc welding experiments using contact tip of three different materials were performed. The contact tips with Cu-P, Cu-Cr, and Cu-ODS were used at the experiments, and the welding characteristics by each contact tip were evaluated. After welding contact tip appearance, welding spatter adhesion amount of the nozzle, and weld bead appearance were evaluated. The welding current and welding voltage were measured to verify arc stability during arc welding.

posVibEditor: Authoring Tool for Designing Vibrotactile Patterns in Mobile Devices (posVibEditor: 모바일 기기에서 진동촉감 패턴의 디자인 저작 도구)

  • Ryu, Jong-Hyun;Choi, Seung-Moon
    • 한국HCI학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.256-261
    • /
    • 2008
  • We developed an authoring tool for designing vibrotactile patterns quickly and easily by using the drag-and-drop paradigm in mobile devices. Designed vibrotactile patterns are registered into a data pool in the XML format, improving the reusability and extensibility of vibrotactile patterns. A multi-channel timeline interface is also incorporated to provide time-synchronized pattern editing for multiple vibration patterns (for multiple vibration actuators). In addition, an internal vibration player is embedded in the authoring tool in order to evaluate the patterns on the spot. A transform function for perceptually transparent vibration rendering can also be set in the editor. Although the authoring tool was developed for mobile devices, it can be used for other applications such as haptic interaction m virtual reality.

  • PDF

EXPERIMENTAL STUDY ON MEASUREMENT OF EMISSIVITY FOR ANALYSIS OF SNU-RCCS

  • CHO YUN-JE;KIM MOON OH;PARK GOON-CHERL
    • Nuclear Engineering and Technology
    • /
    • v.38 no.1
    • /
    • pp.99-108
    • /
    • 2006
  • SNU-RCCS is a water pool type RCCS (Reactor Cavity Cooling System) developed for VHTR (Very High Temperature Reactor) application by SNU (Seoul National University). Since radiation heat transfer is the major process of passive heat removal in a RCCS, it is important to determine the precise emissivity of the reactor vessel. Review studies have used a constant emissivity in the passive heat removal analysis, even though the emissivity depends on many factors such as temperature, surface roughness, oxidation level, wavelength, direction, atmosphere conditions, etc. Therefore, information on the emissivity of a given material in a real RCCS is essential in order to properly analyze the radiation heat transfer in a VHTR. The objectives of this study are to develop a method for compensation of the factors affecting the emissivity measurement using an infrared thermometer and to estimate the true emissivity from the measured emissivity via the developed method, especially in the SNU-RCCS environment. From this viewpoint, we investigated factors such as the attenuation effect of the window, filling gas, and the effect of background radiation on the emissivity measurements. The emissivity of the vessel surface of the SNU-RCCS facility was then measured using a sight tube. The background radiation was subsequently removed from the measured emissivity by solving a simultaneous equation. Finally, the calculated emissivity was compared with the measured emissivity in a separate emissivity measurement device, yielding good agreement with the emissivity increase with vessel temperature in a range of 0.82 to 0.88.

Application of Parallel PSO Algorithm based on PC Cluster System for Solving Optimal Power Flow Problem (PC 클러스터 시스템 기반 병렬 PSO 알고리즘의 최적조류계산 적용)

  • Kim, Jong-Yul;Moon, Kyoung-Jun;Lee, Haw-Seok;Park, June-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.10
    • /
    • pp.1699-1708
    • /
    • 2007
  • The optimal power flow(OPF) problem was introduced by Carpentier in 1962 as a network constrained economic dispatch problem. Since then, the OPF problem has been intensively studied and widely used in power system operation and planning. In these days, OPF is becoming more and more important in the deregulation environment of power pool and there is an urgent need of faster solution technique for on-line application. To solve OPF problem, many heuristic optimization methods have been developed, such as Genetic Algorithm(GA), Evolutionary Programming(EP), Evolution Strategies(ES), and Particle Swarm Optimization(PSO). Especially, PSO algorithm is a newly proposed population based heuristic optimization algorithm which was inspired by the social behaviors of animals. However, population based heuristic optimization methods require higher computing time to find optimal point. This shortcoming is overcome by a straightforward parallel processing of PSO algorithm. The developed parallel PSO algorithm is implemented on a PC cluster system with 6 Intel Pentium IV 2GHz processors. The proposed approach has been tested on the IEEE 30-bus system. The results showed that computing time of parallelized PSO algorithm can be reduced by parallel processing without losing the quality of solution.

The Effects of Age and Information Processing Style on Abilities of Young Children to Understand Spatial Coordinates (유아의 정보처리양식과 연령이 공간좌표인식능력에 미치는 영향)

  • Oh, Mee-Hyeong
    • Journal of the Korean Home Economics Association
    • /
    • v.46 no.9
    • /
    • pp.125-135
    • /
    • 2008
  • The purpose of this study was to examine the effects of young children's age and information processing style in understanding spatial coordinates. For sampling the subjects of this study, Korean version K-ABC Intelligence Test(Moon, Soo-Back, 1997)was conducted with 165 children aged 5-6 who were attending I and G kindergarten in D city. From this pool 30 children who possessed sequential processing style and 30 children who possessed simultaneous processing style were sampled. In order to analyze the understanding of spatial coordinates, a test tool was formulated according to methodology of Blades & Spencer(1989) which was modified. Acquired data was subjected to descriptive and comparative statistical analysis. The following conclusions were arrived at: Firstly, there was significant difference between 5-year-olds and 6-year-olds in understanding spatial coordinates. The 6-year-old group got statistically higher grades than the 5-year-old group in locating a point on the coordinate plane and reading the coordinate numbers. Secondly, there was significant difference between children's information processing style in understanding spatial coordinate. Children with high simultaneous-low sequential processing showed higher performance in locating a point on the coordinate plane and reading coordinate numbers than children with high sequential-low simultaneous processing. Thirdly, after verifying statistical significance of interactivity between young children's age and children's processing strength, there was significant interactive effects in both tasks.

LOW DISSIPATION OF EXCITATION ENERGY IN THE PHOTOSYNTHETIC MACHINERY OF CHILLING-SENSITIVE PLANTS DURING LOWTEMPERATURE PHOTOINHIBITION

  • Moon, Byoung Yong;Lee, Shin Bum;Gong, Yong-Gun;Kang, In-Soon
    • Journal of Photoscience
    • /
    • v.5 no.2
    • /
    • pp.53-61
    • /
    • 1998
  • Using a squash plant, a chilling-sensitive species, and a spinach plant, a chilling-resistant one, effects of chilling temperature on the photosynthetic machinery were studied in terms of chlorophyll fluorescence. When thylakoid membranes were isolated and subjected to incubation at different temperatures, spinach showed stable photosystem II activity at the low temperature side, in contrast to squash which showed quite severe inactivation at low temperature. When parameters of chlorophyll fluorescence were examined, chilling in darkness did not affect either Fv/Fm or photochemical and non-photochemical quenching, in both types of plants. However, chilling of squash plants under irradiance of medium intensity caused a specific decrease in Fv/Fm accompanied by a decline in energy-dependent quenching. Contrastingly, photosystem li of spinach plants were not much affected by light-chilling. When the pool size of zeaxanthin was examined after exposure to high light at different temperatures, squash plants was shown to have a much lower content of antheraxanthin + zeaxanthin, as compared to spinach plants, during low-temperature photoinhibition. These results suggest that chilling-sensitive plants have low capacity to dissipate excitation energy nonradiatively, when they are exposed to low-temperature photoinhibition, and, as a consequence, more vulnerable to photoinhibitory, damage to the photosynthetic apparatus.

  • PDF

Control of molten pool by physical force of bead former in TIG welding of overhead and inclined-up position (위보기 및 경사상진자세의 TIG용접에서 비드성형기의 물리적 힘에 의한 용융지 제어)

  • Ha, Jong-Moon;Ham, Hyo-Sik;Im, Sung-Bin;Seo, Ji-Suk;Cho, Sang-Myung
    • Proceedings of the KWS Conference
    • /
    • 2009.11a
    • /
    • pp.23-23
    • /
    • 2009
  • 우수한 용접부 품질 때문에 TIG를 이용한 오비탈 용접은 파이프 용접에 널리 사용되고 있다. 하지만 루트갭이 없고 루트페이스가 큰 맞대기 오비탈 용접의 위보기 및 경사상진자세에서는 오목한 이면비드가 형성되기 쉽지만, 이러한 문제를 극복하기 위한 연구는 희박한 실정이다. 본 연구에서는 위보기 및 경사상진자세에서 볼록한 이면비드의 형성을 연구하기위해서 용융지의 제어 방법을 적극적으로 검토하였다. 4mm 두께의 SS400 시편을 위보기 및 경사상진자세에서 각각 Bead-on-plate 용접하고, 이 때 비드성형기의 사용에 따른 비드 형상 변화를 관찰하였다. 텅스텐 전극과 비드 성형기간의 거리(Tip To Former Distance, 이하 TTFD)를 4.5mm에서 7.5mm로 1mm단위로 변경시켜 실험하였으며, TTFD가 증가할수록 위보기 및 경사상진자세에서 이면비드 높이가 감소하였으며 표면비드의 처짐이 증가하였다.

  • PDF

Hybrid Welding Process for Sheet Metal and Narrow Gap Fill Pass (하이브리드 용접방식을 이용한 박판 및 후판용접공정)

  • Choi, Hae-Woon;Shin, Hyun-Myung;Im, Moon-Hyuk
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.11
    • /
    • pp.978-983
    • /
    • 2008
  • An application of innovative laser+GMA hybrid welding process is presented for reducing bead humping defects in high speed welding and increasing side wall fusion in narrow groove welding without torch or wire oscillation. In this hybrid process, the laser heat input is applied adjacent to the weld pool at a relatively low power density to produce a wider, flatter weld bead. In bead on plate in sheet metal gauges, the hybrid process was able to produce hump-free welds from 70ipm (${\sim}1780mm/min$) to over 150ipm (${\sim}3810mm/min$) of the travel speed compared to the un-assisted GMAW process. A square-butt joint in 15mm A572 Gr50 steel welds was investigated. A square butt joint with a gap of 3.2mm was filled with 6 passes. Liquid Nitrogen calorimetry and innovative $CO_2$ laser reflective optics were also developed to demonstrate the concept of hybrid welding.

Influence of the adjacent periodontium and inter-implant distance on bone resorption around non-submerged implants;A retrospective clinical and radiographic study (인접 치주조직과 임플란트간 거리가 임플란트 주변 골흡수에 미치는 영향;임상 및 방사선사진 검사에 의한 후향적 연구)

  • Chang, Moon-Taek
    • Journal of Periodontal and Implant Science
    • /
    • v.34 no.3
    • /
    • pp.535-541
    • /
    • 2004
  • The aims of the present study are firstly to investigate the amount of bone loss around non-submerged implants placed in the posterior region and secondly to investigate the relationship between inter-implant and implant-tooth distance and peri-implant bone loss. Thirty-one subjects with 60 implants were selected consecutively from the implant patient pool at the department of Chonbuk National University Hospital. To be included in the study subject, the implant should have been functioned more than 6 months after loading. Inter-implant and implant-tooth distance, distance between implant shoulder and the first bone contact with the implant(DIB) were measured from the scanning image of the radiograph of each implant. The result showed that; 1. inter-implant distance has a statistically significant relationship with DIB in Pearson correlation analysis. 2. the DIB at the implant facing surface of the implant was greater than that of tooth facing surface of the implant. Within limitation of this study, it is suggested to place an implant not too closely to adjacent implants, and the presence of a tooth adjacent to an implant may keep the level of tooth-facing surface of the implant. Further studies with a prospective design are needed to elucidate the relationship between bone changes and various dimensions around implants.

Experimental study of wave energy extraction by a dual-buoy heaving system

  • Kim, J.;Koh, H.J.;Cho, I.H.;Kim, M.H.;Kweon, H.M.
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.9 no.1
    • /
    • pp.25-34
    • /
    • 2017
  • The concentric dual-buoy Wave Energy Converter (WEC), which consists of external buoy (hallow-cylinder) with toroidal appendage and cylindrical internal buoy within the moon-pool is suggested in this research and its performance in various wave conditions is studied. The Linear Electric Generator (LEG), consisting of a permanent magnet and coils, is used as a direct Power Take-Off (PTO) system. To maximize the electrical energy extracted from the PTO system, the relative heave motions between the dual buoys must be highly amplified by the multiple resonance phenomena of dual-buoy and internal-fluid motions. The high-performance range can be widened by distributing those natural frequencies with respect to the peak frequency of the wave spectrum. The performance of the newly developed dual-buoy WEC was measured throughout the systematic 1:5.95-model test in regular and irregular waves conducted in a wave tank at Seoul National University. The model-test results are also validated by an independently developed numerical method.