• 제목/요약/키워드: Monte-Carlo simulations

검색결과 677건 처리시간 0.03초

A cosmic ray muons tomography system with triangular bar plastic scintillator detectors and improved 3D image reconstruction algorithm: A simulation study

  • Yanwei Zhao;Xujia Luo;Kemian Qin;Guorui Liu;Daiyuan Chen;R.S. Augusto;Weixiong Zhang;Xiaogang Luo;Chunxian Liu;Juntao Liu;Zhiyi Liu
    • Nuclear Engineering and Technology
    • /
    • 제55권2호
    • /
    • pp.681-689
    • /
    • 2023
  • Purpose: Muons are characterized by a strong penetrating ability and can travel through thousands of meters of rock, making them ideal to image large volumes and substances typically impenetrable to, for example, electrons and photons. The feasibility of 3D image reconstruction and material identification based on a cosmic ray muons tomography (MT) system with triangular bar plastic scintillator detectors has been verified in this paper. Our prototype shows potential application value and the authors wish to apply this prototype system to 3D imaging. In addition, an MT experiment with the same detector system is also in progress. Methods: A simulation based on GEANT4 was developed to study cosmic ray muons' physical processes and motion trails. The yield and transportation of optical photons scintillated in each triangular bar of the detector system were reproduced. An image reconstruction algorithm and correction method based on muon scattering, which differs from the conventional PoCA algorithm, has been developed based on simulation data and verified by experimental data. Results: According to the simulation result, the detector system's position resolution is below 1 ~ mm in simulation and 2 mm in the experiment. A relatively legible 3D image of lead bricks in size of 20 cm × 5 cm × 10 cm used our inversion algorithm can be presented below 1× 104 effective events, which takes 16 h of acquisition time experimentally. Conclusion: The proposed method is a potential candidate to monitor the cosmic ray MT accurately. Monte Carlo simulations have been performed to discuss the application of the detector and the simulation results have indicated that the detector can be used in cosmic ray MT. The cosmic ray MT experiment is currently underway. Furthermore, the proposal also has the potential to scan the earth, buildings, and other structures of interest including for instance computerized imaging in an archaeological framework.

붕괴모드 조합 예측법에 의한 PSC사장교의 위험도평가 (Probabilistic Risk Assessment of a Cable-Stayed Bridge Based on the Prediction Method for the Combination of Failure Modes)

  • 박미연;조효남;조태준
    • 대한토목학회논문집
    • /
    • 제26권4A호
    • /
    • pp.647-657
    • /
    • 2006
  • 허용응력설계법과 극한한계 상태 설계법에 근거한 케이블과 보강형을 갖는 PSC 사장교의 예를 통해서 통계학적 확률분포를 고려한 확률론적인 위험성을 평가하였다. 사용성 한계상태 및 극한 한계상태에서의 케이블요소의 파괴확률과 거더의 최대 정모멘트. 부모멘트 발생단면, 그리고 최대전단력의 작용단면에서 각각의 요소 파괴 확률을 설계변수의 응답면에서 검토하였다. 응답면 기법(RSM)은 복잡한 다자유도 구조물에서 MCS를 사용하여 얻을 수 없는 상대적으로 매우 작은 파괴 확률값을 얻기 위해 사용이 가능할 뿐만 아니라, FOSM으로 쉽게 얻을 수 없는 한계상태방정식의 미분형태에도 성공적으로 적용이 가능 하다. 케이블과 보강형으로 구성된 병렬저항구조를 시스템 해석을 위해 각각 직렬구조로 연결하여 전체구조물의 체계신뢰성을 평가하고, 제안된 붕괴모드조합 예측값과 비교분석하였다. 제안된 붕괴모드의 조합에 의한 파괴확률검토는 조건부 파괴에 대한 동일한 발생확률을 구하며, 순열방법보다 개선된 시간비용과 효율성을 제공하며, 상하한계파괴확률을 구하는 체계 신뢰성해석에서 검토되지 않는 요소파괴의 조합에 의한 시스템의 위험성 검토를 제공한다.

Material Discrimination Using X-Ray and Neutron

  • Jaehyun Lee;Jinhyung Park;Jae Yeon Park;Moonsik Chae;Jungho Mun;Jong Hyun Jung
    • Journal of Radiation Protection and Research
    • /
    • 제48권4호
    • /
    • pp.167-174
    • /
    • 2023
  • Background: A nondestructive test is commonly used to inspect the surface defects and internal structure of an object without any physical damage. X-rays generated from an electron accelerator or a tube are one of the methods used for nondestructive testing. The high penetration of X-rays through materials with low atomic numbers makes it difficult to discriminate between these materials using X-ray imaging. The interaction characteristics of neutrons with materials can supplement the limitations of X-ray imaging in material discrimination. Materials and Methods: The radiation image acquisition process for air-cargo security inspection equipment using X-rays and neutrons was simulated using a GEometry ANd Tracking (Geant4) simulation toolkit. Radiation images of phantoms composed of 13 materials were obtained, and the R-value, representing the attenuation ratio of neutrons and gamma rays in a material, was calculated from these images. Results and Discussion: The R-values were calculated from the simulated X-ray and neutron images for each phantom and compared with those obtained in the experiments. The R-values obtained from the experiments were higher than those obtained from the simulations. The difference can be due to the following two causes. The first reason is that there are various facilities or equipment in the experimental environment that scatter neutrons, unlike the simulation. The other is the difference in the neutron signal processing. In the simulation, the neutron signal is the sum of the number of neutrons entering the detector. However, in the experiment, the neutron signal was obtained by superimposing the intensities of the neutron signals. Neutron detectors also detect gamma rays, and the neutron signal cannot be clearly distinguished in the process of separating the two types of radiation. Despite these differences, the two results showed similar trends and the viability of using simulation-based radiation images, particularly in the field of security screening. With further research, the simulation-based radiation images can replace ones from experiments and be used in the related fields. Conclusion: The Korea Atomic Energy Research Institute has developed air-cargo security inspection equipment using neutrons and X-rays. Using this equipment, radiation images and R-values for various materials were obtained. The equipment was reconstructed, and the R-values were obtained for 13 materials using the Geant4 simulation toolkit. The R-values calculated by experiment and simulation show similar trends. Therefore, we confirmed the feasibility of using the simulation-based radiation image.

GPU Based Feature Profile Simulation for Deep Contact Hole Etching in Fluorocarbon Plasma

  • Im, Yeon-Ho;Chang, Won-Seok;Choi, Kwang-Sung;Yu, Dong-Hun;Cho, Deog-Gyun;Yook, Yeong-Geun;Chun, Poo-Reum;Lee, Se-A;Kim, Jin-Tae;Kwon, Deuk-Chul;Yoon, Jung-Sik;Kim3, Dae-Woong;You, Shin-Jae
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제43회 하계 정기 학술대회 초록집
    • /
    • pp.80-81
    • /
    • 2012
  • Recently, one of the critical issues in the etching processes of the nanoscale devices is to achieve ultra-high aspect ratio contact (UHARC) profile without anomalous behaviors such as sidewall bowing, and twisting profile. To achieve this goal, the fluorocarbon plasmas with major advantage of the sidewall passivation have been used commonly with numerous additives to obtain the ideal etch profiles. However, they still suffer from formidable challenges such as tight limits of sidewall bowing and controlling the randomly distorted features in nanoscale etching profile. Furthermore, the absence of the available plasma simulation tools has made it difficult to develop revolutionary technologies to overcome these process limitations, including novel plasma chemistries, and plasma sources. As an effort to address these issues, we performed a fluorocarbon surface kinetic modeling based on the experimental plasma diagnostic data for silicon dioxide etching process under inductively coupled C4F6/Ar/O2 plasmas. For this work, the SiO2 etch rates were investigated with bulk plasma diagnostics tools such as Langmuir probe, cutoff probe and Quadruple Mass Spectrometer (QMS). The surface chemistries of the etched samples were measured by X-ray Photoelectron Spectrometer. To measure plasma parameters, the self-cleaned RF Langmuir probe was used for polymer deposition environment on the probe tip and double-checked by the cutoff probe which was known to be a precise plasma diagnostic tool for the electron density measurement. In addition, neutral and ion fluxes from bulk plasma were monitored with appearance methods using QMS signal. Based on these experimental data, we proposed a phenomenological, and realistic two-layer surface reaction model of SiO2 etch process under the overlying polymer passivation layer, considering material balance of deposition and etching through steady-state fluorocarbon layer. The predicted surface reaction modeling results showed good agreement with the experimental data. With the above studies of plasma surface reaction, we have developed a 3D topography simulator using the multi-layer level set algorithm and new memory saving technique, which is suitable in 3D UHARC etch simulation. Ballistic transports of neutral and ion species inside feature profile was considered by deterministic and Monte Carlo methods, respectively. In case of ultra-high aspect ratio contact hole etching, it is already well-known that the huge computational burden is required for realistic consideration of these ballistic transports. To address this issue, the related computational codes were efficiently parallelized for GPU (Graphic Processing Unit) computing, so that the total computation time could be improved more than few hundred times compared to the serial version. Finally, the 3D topography simulator was integrated with ballistic transport module and etch reaction model. Realistic etch-profile simulations with consideration of the sidewall polymer passivation layer were demonstrated.

  • PDF

전립선암에 대한 양성자치료에서 금마커에 의한 방사선 선량분포의 영향 (Dosimetric Influence of Implanted Gold Markers in Proton Therapy for Prostate Cancer)

  • 곽정원;신정욱;김진성;박성용;신동호;윤명근;박소아;김동욱;임영경;이세병
    • 한국의학물리학회지:의학물리
    • /
    • 제21권3호
    • /
    • pp.291-297
    • /
    • 2010
  • 본 연구에서는 양성자 치료에서 치료부위에 금 마커를 삽입하였을 때 양성자 빔의 선량과 그 분포에 미치는 영향을 평가하였다. 1.2 mm 직경에 3 mm 길이의 원통형 금 마커가 사용되었고 양성자 빔의 여러 위치에서 각각의 선량에 미치는 영향을 조사하였다. 3차원 moving 팬텀과 유효 반경이 0.5 mm인 정위적 방사선 치료용 다이로드 검출기를 이용하여 금마커의 방사선 선량으로의 영향을 결정하였다. Gafchromic film을 이용한 필름에 의한 선량 평가도 시행하였다. 그리고 선량-체적관계 히스토그램을 통한 분석을 위하여 GEANT4 전산 모의 도구 모음을 이용한 전산모의를 실시하였다. 마커의 움직임에 대한 영향성을 평가하기 위하여 직장 풍선을 적용하고 금 마커를 삽입한 10명의 환자에 대한 MV 영상을 이용하였다. 하나의 금 마커에 의하여 처방선량의 95% 이하가 들어간 체적은 0.15 cc로 작지만 그 체적은 치료부위 안쪽에 위치하고 평행이동에 대하여 발려져서 없어지지 않았다. 금 마커의 위치와 양성자 빔의 상태에 따라서 선량분포에 각각 다른 영향을 미치고 이는 임상치료에서 충분히 고려되어야 할 것으로 사료된다.

평균 유선선량 측정방법의 표준화 및 유방 두께, 실질양상과의 상관관계 분석 (Standardization of the Method of Measuring Average Glandular Dose (AGD) and Evaluation of the Breast Composition and Thickness for AGD)

  • 박혜숙;김희중;이창래;조효민;유아람
    • 한국의학물리학회지:의학물리
    • /
    • 제20권1호
    • /
    • pp.21-29
    • /
    • 2009
  • 유방암은 우리나라 여성에게 발생하는 암 중에서 발병률이 높은 암이다. 따라서 유방자가진단, 임상적 검사, 유방 X선촬영 등과 같은 유방암 초기 검출검사는 중요하다. 이들 중 유방 X선촬영은 무자각증상 시기에 유방암 초기 검출을 위해 40대 이상의 여성들에게 매년마다 시행하기를 권고하고 있다. 그러나 유방의 유선조직은 방사선 민감성 조직이다. 이에 유방 X선촬영장치의 평가 중 평균 유선선량 측정은 매우 중요한 부분이 된다. 평균 유선선량의 직접측정은 어렵기 때문에 incident air kerma 측정, 적절한 변환계수 등을 적용하여 계산하게 된다. 따라서 본 연구의 첫 번째 목적은 평균 유선선량의 측정 방법의 표준화이다. 두 번째는 몬테칼로 시뮬레이션을 이용하여 평균 유선선량과 유방 실질양상 및 두께와 의 상관관계를 분석하고자 했다. 본 연구 결과, IAEA 가이드라인(CoP)에 따라 평균 유선선량 측정방법을 제시하였다. 전반적으로 우리나라는 유방촬영 시 받는 평균 유선선량이 식품의약품안전청 및 한국의료영상품질관리원에서 제시하는 3mGy 이하로 측정되었다. 측정된 평균 유선선량과 시뮬레이션된 평균 유선선량은 각각 1.7과 1.6 mGy로 큰 차이를 보이지 않았다. 시뮬레이션된 평균 유선선량은 주로 유방의 유선조직의 비율에 따라 의존한다. 유방의 glandularity 증가에 따라 낮은 에너지의 광자의 흡수가 증가하여 평균 유선선량도 증가하였다. 또한 유방의 두께가 두꺼울수록 평균 유선선량은 증가하였다. 결과적으로, 본 연구는 유방촬영의 진단 참고준위 확립을 위한 기초자료로 활용될 것이다.

  • PDF

부가필터를 적용한 디지털 흉부단층합성검사에서 환자 체형에 따른 화질 평가와 선량감소 효과 (Effect of Patient Size on Image Quality and Dose Reduction after Added Filtration in Digital Chest Tomosynthesis)

  • 복근성;김상현
    • 한국방사선학회논문지
    • /
    • 제12권1호
    • /
    • pp.23-30
    • /
    • 2018
  • 흉부 단층 합성검사(Chest Digital Tomosynthesis, DTS)시 환자 체형에 따른 0.3 mm 구리 필터의 적용 및 AEC의 감도 변화에 의한 유효선량감소 효과와 폐 결절 검출능력을 평가하여 선량 최적화 조건을 평가하고자 한다. 8개의 인공 결절을 인체 팬텀 폐 영역내에 삽입하고 0.3 mm 구리 필터 적용 유무, 감도 변화에 따라 팬텀의 DTS 영상을 각각 획득하였다. 환자 체형에 따른 비교를 위해 팬텀 사이즈를 세 그룹으로 분류하여 small size에서는 결절이 삽입된 인체 팬텀을 단독으로 사용하였고 Average size에서는 한 개의 PMMA를, Large size에서는 두 개의 PMMA를 인체팬텀 후방에 밀착하여 위치시켰다. 유효선량은 몬테카를로 시뮬레이션을 이용하여 계산 되었고 영상의 화질평가를 위해서 CNR과 SNR 측정을 통한 정량 평가와 인공 결절 검출 수를 통한 검출민감도로 정성평가를 시행하였다. 모든 데이터는 통계학적으로 분석하였다. 유효 선량은 Small size일 때 $26{\mu}Sv$, Average size $70{\mu}Sv$, Large size $133{\mu}Sv$ 감소하였다. 유효선량은 0.3mm 구리 필터의 적용 여부에 따라 유의한 차이가 있었다(p<0.05). 정량적 화질 평가에서는 0.3mmCu필터 사용 시 CNR과 SNR 모두 통계적으로 유의한 차이는 없었다(p>0.05). 또한 정성적 화질평가에서도 결절 검출 민감도는 팬텀 사이즈별 전체 그룹에서 통계적으로 유의한 차이가 없었다(p>0.05). DTS에서 0.3 mmCu필터의 사용은 폐 결절 검출에서 진단적 가치를 유지하면서 환자 피폭선량 감소효과를 얻을 수 있다. 또한 실험에서 Large size 그룹의 경우 유효선량 감소 정도가 두드러진 점으로 보아 실제 체형이 큰 환자의 경우 0.3 mm Cu필터 사용은 더 높은 유효선량 감소 효과를 기대 할 수 있을 것이라 사료된다