• 제목/요약/키워드: Monte-Carlo and Calibration

검색결과 79건 처리시간 0.032초

A hidden Markov model for long term drought forecasting in South Korea

  • Chen, Si;Shin, Ji-Yae;Kim, Tae-Woong
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2015년도 학술발표회
    • /
    • pp.225-225
    • /
    • 2015
  • Drought events usually evolve slowly in time and their impacts generally span a long period of time. This indicates that the sequence of drought is not completely random. The Hidden Markov Model (HMM) is a probabilistic model used to represent dependences between invisible hidden states which finally result in observations. Drought characteristics are dependent on the underlying generating mechanism, which can be well modelled by the HMM. This study employed a HMM with Gaussian emissions to fit the Standardized Precipitation Index (SPI) series and make multi-step prediction to check the drought characteristics in the future. To estimate the parameters of the HMM, we employed a Bayesian model computed via Markov Chain Monte Carlo (MCMC). Since the true number of hidden states is unknown, we fit the model with varying number of hidden states and used reversible jump to allow for transdimensional moves between models with different numbers of states. We applied the HMM to several stations SPI data in South Korea. The monthly SPI data from January 1973 to December 2012 was divided into two parts, the first 30-year SPI data (January 1973 to December 2002) was used for model calibration and the last 10-year SPI data (January 2003 to December 2012) for model validation. All the SPI data was preprocessed through the wavelet denoising and applied as the visible output in the HMM. Different lead time (T= 1, 3, 6, 12 months) forecasting performances were compared with conventional forecasting techniques (e.g., ANN and ARMA). Based on statistical evaluation performance, the HMM exhibited significant preferable results compared to conventional models with much larger forecasting skill score (about 0.3-0.6) and lower Root Mean Square Error (RMSE) values (about 0.5-0.9).

  • PDF

On-orbit test simulation for field angle dependent response measurement of the Amon-Ra energy channel instrument

  • 성세현;김석환;류동옥;홍진석
    • 천문학회보
    • /
    • 제37권2호
    • /
    • pp.211.1-211.1
    • /
    • 2012
  • The on-orbit test simulation for predicting the instrument directional responsivity was conducted by the Monte Carlo based integrated ray tracing (IRT) computation technique and analytic flux-to-signal conversion algorithms. For the on-orbit test simulation, the Sun model consists of the Lambertian scattering sphere and emitting spheroid rays, the Amon-Ra instrument is a two-channel including a broadband scanning radiometer (energy channel) and an imager with ${\pm}2^{\circ}$ FOV (visible channel). The solar radiation produced by the Sun model is directed to the instrument viewing port and traced through the dual channel optical train. The instrument model is rotated on its rotation axis and this gives a slow scan of the Sun model over the full field of view. The direction of the incident lights are fed with scanned images obtained from the visible channel instrument. The instrument responsivity was computed by the ratio of the incident radiation input to the instrument output. In the radiometric simulation, especially, measured BRDF of the 3D CPC was used for scattering effects on radiometry. With diamond turned 3D CPC inner surface, the anisotropic surface scattering model from the measured data was applied to ray tracing computation. The technical details of the on-orbit test simulation are presented together with field-of-view calibration plan.

  • PDF

기준점에서의 물 흡수선량을 이용한 Ir-192 선원의 공기커마 세기 계산을 위한 알고리즘 개발 (The Development of Air-kerma Strength Calculation Algorithm in Terms of the Absorbed Dose to Water for HDR Ir-192 Source)

  • 허현도;김우철;노준규;이석;이상훈;조삼주;신동오;최진호;권수일;김성훈
    • 한국의학물리학회지:의학물리
    • /
    • 제17권4호
    • /
    • pp.232-237
    • /
    • 2006
  • 본 연구의 목적은 Ir-192 선원의 검교정을 겉보기 방사능(apparent activity)을 이용하지 않고 물속 기준점에서 흡수선량을 측정함으로써 공기커마 세기(air-kerma strength, Sk)를 계산하고자 알고리즘을 개발하였다. 연구를 위하여 근접치료용 다목적 팬톰(multi purpose brachytherapy Phantom, MPBP)을 제작하였다. 물 흡수선량 측정은 고선량률 근접치료기(micro-Selectron, Nucletron, Netherlands)에 장착된 Ir-192 선원(Mallinckrodt Medical B.V., Netherlands)을 대상으로 측정하였다. 물 흡수선량은 몬테칼로 계산방법으로 계산된 이온전리함(TM30013, PTW, Germany)의 물 흡수선량 교정인자($N_{D.W.Q}$)를 이용하여 결정하였다. 물 흡수선량은 한 개의 선원에 대하여 4 cm에서 7 cm까지 측정하였다. 측정된 값은 전산화 치료계획 장치에서(plato BPS, ver 13.2, Nucletron, Netherlands) 계산된 값과 비교하였다. 공기커마 세기(Sk)는 기준점 5 cm되는 곳에서 3개의 Ir 선원에 대하여 구하였다. 계산된 공기커마 세기는 선원제조사에서 제공된 값과 비교하였다. 몬테칼로 계산방법으로 계산된 이온전리함의 물 흡수선량 교정인자는 5.28 cGy/nC이었다. 한 개 선원에서 측정한 물 흡수선량 값은 -2.16%에서 -0.84%까지 상대오차를 나타내었다. 공기커마 세기는 제조사에서 제공된 값과 비교하여 -0.6%에서 +1.8% 제조사 권고치 ${\pm}5%$ 이내로 잘 일치하였다. 본 연구에서 개발한 알고리즘은 기준점에서의 물 흡수선량을 정확히 결정함으로써 선원의 공기커마 세기를 구할 수 있었다. 이러한 물 흡수선량을 통한 Ir-192 선원의 검교정 방법들은 미국의학물리학회(AAPM) 보고서 TG-43에서 권고한 흡수선량 계산 알고리즘에 바로 적용할 수 있는 것으로 사료된다.

  • PDF

비감속 $^{252}Cf$ 중성자선원에 대한 비등방성교정인자 및 선량당량환산인자 (Anisotropy and Dose Equivalents Conversion Factors for the Unmoderated $^{252}Cf$ Source)

  • 정덕연;장시영;윤석철;김종수
    • Journal of Radiation Protection and Research
    • /
    • 제18권2호
    • /
    • pp.71-79
    • /
    • 1993
  • 중성자 측정장비 교정을 위한 표준중성자장을 제작하기 위하여 순수멕스월분포(kt=1.42MeV)로부터 $^{252}Cf$ 자발핵분열 중성자선원의 밀봉이 교정인자에 미치는 영향을 고찰하였다. SR-Cf-100과 SR-Cf-1273 밀봉모형을 실제 제작조건으로 하여 MCNP 코드를 사용하여 몬테카를로 모의를 수행하여, 비등방성교정인자와 선속밀도-대-선량당량 환산인자를 산정하였고, 다른 연구결과와 비교하였다. 결과로서, $FI({\theta}=90^{\circ})$는 1.061(통계오차 : ${\pm}0.2%$), $H/{\Phi}$$333.9(pSv\;cm^2)$ (통계오차 : ${\pm}0.5%$)인 것으로 산정되었다. 이 환산인자$(H/{\Phi})$의 값은 ISO 8529의 권고보다 1.8%가 작은 것인데, 이것은 한국원자력연구소의 비감속 $^{252}Cf$중성자선원의 스펙트럼이 ISO의 것보다 약간 더 연화하다는 물리적 의미를 갖는다.

  • PDF

Detection of Water Cloud Microphysical Properties Using Multi-scattering Polarization Lidar

  • Xie, Jiaming;Huang, Xingyou;Bu, Lingbing;Zhang, Hengheng;Mustafa, Farhan;Chu, Chenxi
    • Current Optics and Photonics
    • /
    • 제4권3호
    • /
    • pp.174-185
    • /
    • 2020
  • Multiscattering occurs when a laser transmits into dense atmosphere targets (e.g. fogs, smoke or clouds), which can cause depolarization effects even though the scattering particles are spherical. In addition, multiscattering effects have additional information about microphysical properties of scatterers. Thus, multiscattering can be utilized to study the microphysical properties of the liquid water cloud. In this paper, a Monte Carlo method was used to simulate multi-scattering transmission properties of Lidar signals in the cloud. The results showed the slope of the degree of linear polarization (SLDLP) can be used to invert the extinction coefficient, and then the cloud effective size (CES) and the liquid water content (LWC) may be easily obtained by using the extinction coefficient and saturation of the degree of linear polarization (SADLP). Based on calculation results, a microphysical properties inversion method for a liquid cloud was presented. An innovative multiscattering polarization Lidar (MSPL) system was constructed to measure the LWC and CES of the liquid cloud, and a new method based on the polarization splitting ratio of the Polarization Beam Splitter (PBS) was developed to calibrate the polarization channels of MSPL. By analyzing the typical observation data of MSPL observation in the northern suburbs of Nanjing, China, the LWC and CES of the liquid water cloud were obtained. Comparisons between the results from the MSPL, MODIS and the Microwave radar data showed that, the microphysical properties of liquid cloud could be retrieved by combining our MSPL and the inversion method.

환경 방사능 처리기술에서의 Compton suppression 및 Unsuppression system을 이용한 토양시료의 MDA 측정 (Measurement of MDA of Soil Samples Using Unsuppression System and Compton Suppression of Environmental Radioactivity in Processing Technology)

  • 강수만;임인철;이재승;장은성;이미현;권경태;김창태
    • 한국방사선학회논문지
    • /
    • 제8권6호
    • /
    • pp.293-299
    • /
    • 2014
  • Compton suppression 장치는 Compton 산란 반응을 이용하여, 스펙트럼의 Compton continuum 부분을 억제함으로써 Compton continuum 영역 내에서의 감마선 피크들의 분석을 보다 명확하게 할 수 있게 해주는 장치이다. 표층토양 시료에서 검출된 인공 방사능인 $^{137}Cs$과 자연 방사능인 $^{40}K$핵종의 방사능 농도 값들에 대한 방사능 계수치가 백그라운드를 상회하는 측정값이 발생되거나, 불필요한 방해피크나 비해석 대상 피크에 대하여 검출된 표준선원의 방사능 농도 값들의 실측치에 대한 background를 비억제 스펙트럼(Compton Unsuppression)과 억제 스펙트럼(Compton suppression)을 적용시켜 측정 에너지에 대한 교정을 알고자 점선원인 $^{137}Cs$을 거리별에 따라 측정하여, 몬테칼로 시뮬레이션과 비교 분석함으로서 효율적인 검출 능력을 얻고자 함이며, Compton 억제 인자를 보면 거리가 멀어짐에 따라 CSF 값이 클수록 더 많은 Compton suppression가 이루어졌음을 알 수 있고, $^{137}Cs$을 이용한 컴프턴 비억제 모드와 억제모드로 측정된 스펙트럼에서 컴프턴 연속에 의한 백그라운드가 감소함을 알 수 있었다.

Correction of Prompt Gamma Distribution for Improving Accuracy of Beam Range Determination in Inhomogeneous Phantom

  • Park, Jong Hoon;Kim, Sung Hun;Ku, Youngmo;Lee, Hyun Su;Kim, Young-su;Kim, Chan Hyeong;Shin, Dong Ho;Lee, Se Byeong;Jeong, Jong Hwi
    • 한국의학물리학회지:의학물리
    • /
    • 제28권4호
    • /
    • pp.207-217
    • /
    • 2017
  • For effective patient treatment in proton therapy, it is therefore important to accurately measure the beam range. For measuring beam range, various researchers determine the beam range by measuring the prompt gammas generated during nuclear reactions of protons with materials. However, the accuracy of the beam range determination can be lowered in heterogeneous phantoms, because of the differences with respect to the prompt gamma production depending on the properties of the material. In this research, to improve the beam range determination in a heterogeneous phantom, we derived a formula to correct the prompt-gamma distribution using the ratio of the prompt gamma production, stopping power, and density obtained for each material. Then, the prompt-gamma distributions were acquired by a multi-slit prompt-gamma camera on various kinds of heterogeneous phantoms using a Geant4 Monte Carlo simulation, and the deduced formula was applied to the prompt-gamma distributions. For the case involving the phantom having bone-equivalent material in the soft tissue-equivalent material, it was confirmed that compared to the actual range, the determined ranges were relatively accurate both before and after correction. In the case of a phantom having the lung-equivalent material in the soft tissue-equivalent material, although the maximum error before correction was 18.7 mm, the difference was very large. However, when the correction method was applied, the accuracy was significantly improved by a maximum error of 4.1 mm. Moreover, for a phantom that was constructed based on CT data, after applying the calibration method, the beam range could be generally determined within an error of 2.5 mm. Simulation results confirmed the potential to determine the beam range with high accuracy in heterogeneous phantoms by applying the proposed correction method. In future, these methods will be verified by performing experiments using a therapeutic proton beam.

고감도 MOSFET 선량계 방사선학적 특성 연구 (Radiological Characterization of the High-sensitivity MOSFET Dosimeter)

  • 조성구;김찬형
    • 한국의학물리학회지:의학물리
    • /
    • 제15권4호
    • /
    • pp.215-219
    • /
    • 2004
  • MOSFET 선량계는 기존의 선량계들에 비해 여러 가지 장점이 있기 때문에 최근에 방사선 치료뿐만 아니라 방사선 진단 등 기타 여러 분야에서 선량검증을 위해 시도되고 있다. 하지만 이렇게 사용되기 위해서는 중ㆍ저에너지 범위의 광자선에 대한 MOSFET 선량계의 방사선학적 특성파악이 선행되어야 한다. 본 연구에서는 고감도 MOSFET 선량계의 여러가지 방사선학적 특성을 자세하게 연구할 수 있는 3차원 몬테칼로 전산모사 모델을 개발하였다. 고감도 MOSFET 선량계의 검출부위는 매우 얇아서 MCNP에서 기본적으로 제공하는 Tally를 사용하면 검출부위에 흡수된 에너지를 정확하게 결정할 수 없으므로 검출부위에 주어진 에너지를 전자들의 트랙들로부터 직접 계산하는 방법을 채택하였다. 개발된 모델은 에너지 의존도, 전자 기여도, 깊이 의존도 등의 MOSFET 선량계의 방사선학적 특성을 연구하기 위해 사용되었다. 에너지 의존도는 15 keV에서 6 MeV 에너지 범위에서 정량화하였는데 약 40 keV에서 최대 6.6으로 나타났다. 본 연구에서는 PTRAC 파일과 Sabrina 코드를 이용하여 MOSFET 선량계 각 부분에서의 전자 기여도를 조사하였다. 깊이 의존도는 신체 내 평균 깊이를 15 cm로 가정할 때 0.662 MeV의 경우는 교정인자 1.16 그리고 1.25 MeV의 경우는 교정인자 1.11을 사용하여 깊이 의존도에 의한 오차를 줄일 수 있다.

  • PDF

에너지 변조 필터를 이용한 이중 에너지 콘빔 CT의 선량 평가 (Evaluation of Radiation Dose for Dual Energy CBCT Using Multi-Grid Device)

  • 주은빈;안소현;조삼주;금기창;이레나
    • 한국의학물리학회지:의학물리
    • /
    • 제27권1호
    • /
    • pp.31-36
    • /
    • 2016
  • 본 연구에서는 이중에너지 영상을 획득하는 방법으로, 구리판을 이용한 에너지 변조 필터를 사용하였을 때의 선량을 계산 및 측정하였고, 기존의 다른 방법들과 선량을 비교하였다. 몬테칼로 전산모사를 이용하여 에너지 변조 필터에 의한 선량 변화를 평가하기 위하여 MCNPX를 사용하였다. 두경부, 흉부, 복부 촬영에 주로 사용되는 관전압인 80, 120 kVp에 대한 스펙트럼을 SPEC78 프로그램으로 생성하여 선원을 모사하였고, 구리 물질로 이루어진 에너지 변조 필터(밀도: $8.96g/cm^3$)는 두께를 0.5 mm부터 2.0 mm까지 0.5 mm 간격으로 변화시켜가면서 선원으로부터 20.0 cm 거리에 X-선 창을 절반만 가리도록 모델링 하였다. 몬테칼로 전산모사 값과 실제 선량 값을 비교하기 위해서는 교정 상수가 필요하므로, Gafchromic EBT3 필름에 알고 있는 선량을 조사한 후 판독하여 선량 교정 곡선을 획득하였다. 실험과 동일한 조건으로 MCNPX의 f6 tally로 획득한 결과값과 측정값 간의 선량 환산 인자는 $7.2*10^4cGy/output$으로 구해졌으며, 관전압 80 kVp과 관전류 6 mA의 조건으로 콘빔 CT 촬영 시, 평균 10.1 cGy (표준편차 2.7 cGy) 조사됨을 알 수 있었다. 에너지 변조 필터에 기반한 이중 에너지 영상 획득 기술을 적용한 본 연구에서는 이중 에너지 콘빔 CT 시스템의 선량이 단일 에너지 CT 시스템의 선량보다 33~40% 감소함을 알 수 있다. 또한, 에너지 변조 필터에서 발생한 산란선에 의한 선량 증가 효과는 거의 없었다. 따라서, 인체 내 물질 분별력이 우수하여 임상에 널리 응용되었던 기존 이중 에너지 CT 시스템의 상대적으로 피폭선량이 높다는 단점을 효과적으로 개선할 수 있다.