• Title/Summary/Keyword: Monte-Carlo 시뮬레이션

Search Result 786, Processing Time 0.025 seconds

Monte Carlo Studies on an Amorphous Silicon (a-Si:H) Digital X-Ray Imaging Device (무정형 실리콘(a-Si : H) 디지털 X-선 영상기기의 개발을 위한 Monte Carlo 컴퓨터 모의실험연구)

  • 이형구;신경섭
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.3
    • /
    • pp.225-232
    • /
    • 1998
  • Results of Monte Carlo simulations on amorphous silicon based x-ray imaging arrays are described. In order to investigate the characteristics of amorphous silicon x-ray imaging devices and to provide the optimum design parameter, Monte Carlo simulations were performed. Monte Carlo simulation codes for our purpose were developed and various combinations of x-ray peak voltages, aluminum filter thicknesses, CsI(TI) thicknesses, and amorphous silicon photodiode pixel sizes were tested in connection with detection efficiency and spatial resolution of the amorphous silicon based x-ray imager. With usual Csl(TI) thickness of 300${\mu}{\textrm}{m}$-500${\mu}{\textrm}{m}$, detection efficiency was in the range of 70%-95% and energy absorption efficiency was in the range of 40%-70% for 60kVp-120kVp x-ray. From the simulations it was found that amorphous silicon pixel size and Csl(TI) thickness were the most important parameters which determine the resolution of the imager. By use of our simulation results we could provide proper combinations of Csl(TI) thicknesses and pixels sizes for optimum sensitivity and resolution.

  • PDF

Grand-Canonical Monte Carlo 시뮬레이션을 이용한 고분자 전해질 다이오드의 메커니즘 연구

  • Lee, Dong-Hyeok;Jang, Rak-U
    • Proceeding of EDISON Challenge
    • /
    • 2016.03a
    • /
    • pp.80-85
    • /
    • 2016
  • 본 연구에서는 Grand-Canonical Monte Carlo 시뮬레이션(GCMC)을 이용하여 서로 반대의 전하를 띤 고분자 전해질의 정전기적 특징을 이해하고, 고분자 전해질 다이오드의 메커니즘을 연구하였다. 고분자 전해질과 서로 반대의 전하를 띤 이온들의 모델은 전하를 띤 free-jointed hard chain과 hard sphere을 이용하였다. 본 연구진은 위와 같은 시뮬레이션을 통해, 평형 상태일 때의 고분자 전해질과 이온의 분포를 연구하였으며, 이 시스템에 전압을 걸어줌에 따라 이온의 이동 모습을 관찰하였다. 또한 전압의 효과와 더불어 고분자 전해질의 농도와 이온들의 크기 변화에 대해서도 연구를 진행하였다.

  • PDF

Interference Analysis based on the Monte-Carlo Method (Monte-Carlo 기반의 간섭분석에 관한 연구)

  • Kim, Seong-Kweon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.3 no.2
    • /
    • pp.58-64
    • /
    • 2008
  • In this paper, we proposed the methodology of interference analysis based on monte-carlo method for effective use of Industrial, Scientific, Medical (ISM) band. The interference scenario is divided according to the distance and density. The simulation of interference analysis evaluates the interference probability according to distribution density of Interfering Transmitters (It) in the Secure Interference Area (SIA). The SIA is gained from the Interference Efficiency Range that satisfied to Interference Permissible Range of Victim Receiver (Vr). Simulation result that apply the proposed interference scenario to the WLAN and bluetooth, Interference Permissible Range was 60~400m. And the WLAN was acceptable within interference permissible range to six bluetooth that exist in the SIA. In the same condition, when applied Listen Before Talk (LBT) based on Cognitive Radio (CR) to the bluetooth using Frequency Hopping (FH), interference probability was decreased sharply. The Spectrum Engineering Advanced Monte Carlo Analysis Tool (SEAMCAT) that has been developed based on the monte-carlo method by European Radio-communications Office (ERO) were used to the interference simulation.

  • PDF

The Comparison Analysis of an Estimators of Nonlinear Regression Model using Monte Carlo Simulation (몬테칼로 시뮬레이션을 이용한 비선형회귀추정량들의 비교 분석)

  • 김태수;이영해
    • Journal of the Korea Society for Simulation
    • /
    • v.9 no.3
    • /
    • pp.43-51
    • /
    • 2000
  • In regression model, we estimate the unknown parameters by using various methods. There are the least squares method which is the most general, the least absolute deviation method, the regression quantile method and the asymmetric least squares method. In this paper, we will compare each others with two cases: firstly the theoretical comparison in the asymptotic sense and then the practical comparison using Monte Carlo simulation for a small sample size.

  • PDF

Monte Carlo simulation of the estimators for nonlinear regression model (비선형 회귀모형 추정량들의 몬데칼로 시뮬레이션에 의한 비교)

  • 김태수;이영해
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 2000.11a
    • /
    • pp.6-10
    • /
    • 2000
  • In regression model we estimate the unknown parameters using various methods. There are the least squares method which is the most general, the least absolute deviation, the regression quantile and the asymmetric least squares method. In this paper, we will compare each others with two case: to begin with the theoretical comparison in the asymptotic sense, and then the practical comparison using Monte Carlo simulation for a small sample size.

  • PDF

Monte Carlo Simulation for the Measurement of Entrance Skin Dose on Newborn and Infants (영·유아의 입사피부선량 측정을 위한 몬테카를로 시뮬레이션)

  • Kim, Sang-Tae
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.6
    • /
    • pp.346-352
    • /
    • 2012
  • Radiation dose estimation on the newborn and infants during radiation examinations, unlike for the adults, is not actively being progressed. Therefore, as an index to present exposure dose during radiation examinations on newborn and infants, entrance skin dose was measured, and the result was compared with results of monte carlo simulation to raise reproducibility of entrance skin dose measurement, and it was proved that various geometry implementation was possible. The resulting values through monte carlo simulation was estimated using normalization factors for entrance skin dose to calibrate radiation dose and then normalized to a unit X ray radiation field size. Average entrance skin dose per one time exposure was $78.41{\mu}Gy$ and the percentage error between measurement by dosimeter and by monte carlo simulation was found to be -4.77%. Entrance skin dose assessment by monte carlo simulation provides possible alternative method in difficult entrance skin dose estimation for the newborn and infants who visit hospital for actual diagnosis.

A Methodology on Treating Uncertainty of LCI Data using Monte Carlo Simulation (몬테카를로 시뮬레이션을 이용한 LCI data 불활실성 처리 방법론)

  • Park Ji-Hyung;Seo Kwang-Kyu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.12
    • /
    • pp.109-118
    • /
    • 2004
  • Life cycle assessment (LCA) usually involves some uncertainty. These uncertainties are generally divided in two categories such lack of data and data inaccuracy in life cycle inventory (LCI). This paper explo.es a methodology on dealing with uncertainty due to lack of data in LCI. In order to treat uncertainty of LCI data, a model for data uncertainty is proposed. The model works with probabilistic curves as inputs and with Monte Carlo Simulation techniques to propagate uncertainty. The probabilistic curves were derived from the results of survey in expert network and Monte Carlo Simulation was performed using the derived probabilistic curves. The results of Monte Carlo Simulation were verified by statistical test. The proposed approach should serve as a guide to improve data quality and deal with uncertainty of LCI data in LCA projects.

Analysis of Electron Transport in InAlAs/InGaAs HBT by Hybride Monte Carlo Simulation (Hybrid Monte Carlo 시뮬레이션에 의한 InAlAs/InGaAs HBT의 전자전송 해석)

  • 송정근;황성범;이경락
    • Electrical & Electronic Materials
    • /
    • v.10 no.9
    • /
    • pp.922-929
    • /
    • 1997
  • As the size of semiconductor devices shrinks in the horizontal as well as vertical dimension it is difficult to estimate the transport-velocity of electron because they drift in non-equilibrium with a few scattering. In this paper HYbrid Monte Carlo simulator which employs the drift-diffusion model for hole-transport and Monte Carlo model for electron-transport in order to reduce the simulation time and increase the accuracy as well has been developed and applied to analyze the electron-transport in InAlAs/InGaAs HBT which is attractive for an ultra high speed active device in high speed optical fiber transmission systems in terms of the velocity and energy distribution as well as cutoff frequency.

  • PDF

Tolerance Allocation Method for IR Optics Fabrication Using Monte-Carlo Simulation Based on Measured Reflective Eccentricity (편심측정 결과가 반영된 몬테카를로 시뮬레이션을 이용한 적외선 광학계 조립정렬 공차 할당 기법)

  • Yoo, Jae-Eun
    • Korean Journal of Optics and Photonics
    • /
    • v.22 no.4
    • /
    • pp.161-169
    • /
    • 2011
  • In this paper, a tolerance allocation method using Monte-Carlo simulation with measured reflective eccentricity for high-sensitive IR optics is proposed. During optics fabrication and alignment, reflective eccentricity was measured using an optical centration measurement instrument. A Monte-Carlo simulation was performed using measured eccentricity data, and it gives statistical estimated performance of the optics after fabrication. The validity of the proposed tolerance allocation method was verified comparing the estimated MTF result with the measured MTF result of the fabricated optics.