• Title/Summary/Keyword: Monte Carlo simulation code

Search Result 276, Processing Time 0.025 seconds

Monte Carlo Simulation Codes for Nuclear Medicine Imaging (핵의학 영상연구를 위한 몬테칼로 모사코드)

  • Chung, Yang Hyun;Beak, Cheal-Ha;Lee, Seung-Jae
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.2
    • /
    • pp.127-136
    • /
    • 2008
  • Monte Carlo simulation methods are especially useful in studying a variety of problems difficult to calculate by experimental or analytical approaches. Nowadays, they are extensively applied to simulate nuclear medicine instrumentations such as single photon emission computed tomography (SPECT) and positron emission tomography (PET) for assisting system design and optimizing imaging and processing protocols. The goal of this paper is to address the practical issues, a potential user of Monte Carlo simulations for nuclear medicine can encounter, to help them to choose a code. This review introduces the different types of Monte Carlo codes currently available for nuclear medicine, comments main features and properties for a code to be proper for a given purpose, and discusses current research trends in Monte Carlo codes.

Geant 4 Monte Carlo simulation for I-125 brachytherapy

  • Jie Liu;M.E. Medhat;A.M.M. Elsayed
    • Nuclear Engineering and Technology
    • /
    • v.56 no.7
    • /
    • pp.2516-2523
    • /
    • 2024
  • This study aims to validate the dosimetric characteristics of Low Dose Rate (LDR) I-125 source Geant4-based Monte Carlo code. According to the recommendation of the American Association of Physicists in Medicine (AAPM) task group report (TG-43), the dosimetric parameters of a new brachytherapy source should be verified either experimentally or theoretically before clinical procedures. The simulation studies are very important since this procedure delivers a high dose of radiation to the tumor with only a minimal dose affecting the surrounding tissues. GEANT4 Monte Carlo simulation toolkit associated brachytherapy example was modified, adapted and several updated techniques have been developed to facilitate and smooth radiotherapy techniques. The great concordance of the current study results with the consensus data and with the results of other MC based studies is promising. It implies that Geant4-based Monte Carlo simulation has the potential to be used as a reliable and standard simulation code in the field of brachytherapy for verification and treatment planning purposes.

Development of Electron Beam Monte Carlo Simulation and Analysis of SEM Imaging Characteristics (전자빔 몬테 카를로 시물레이션 프로그램 개발 및 전자현미경 이미징 특성 분석)

  • Kim, Heung-Bae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.5
    • /
    • pp.554-562
    • /
    • 2012
  • Processing of Scanning electron microscope imaging has been analyzed in both secondary electron (SE) imaging and backscattered electron (BSE) image. Because of unique characteristics of both secondary electron and backscattered electron image, mechanism of imaging process and image quality are quite different each other. For the sake of characterize imaging process, Monte Carlo simulation code have been developed. It simulates electron penetration and depth profile in certain material. In addition, secondary electron and backscattered electron generation process as well as their spatial distribution and energy characteristics can be simulated. Geometries that has fundamental feature have been imaged using the developed Monte Carlo code. Two, SE and BSE images generation process will be discussed. BSE imaging process can be readily used to discriminate in both material and geometry by simply changing position and direction of BSE detector. The developed MC code could be useful to design BSE detector and their position. Furthermore, surface reconstruction technique is possibly developed at the further research efforts. Basics of Monte Carlo simulation method will be discussed as well as characteristics of SE and BSE images.

Probabilistic determination of initial cable forces of cable-stayed bridges under dead loads

  • Cheng, Jin;Xiao, Ru-Cheng;Jiang, Jian-Jing
    • Structural Engineering and Mechanics
    • /
    • v.17 no.2
    • /
    • pp.267-279
    • /
    • 2004
  • This paper presents an improved Monte Carlo simulation for the probabilistic determination of initial cable forces of cable-stayed bridges under dead loads using the response surfaces method. A response surface (i.e. a quadratic response surface without cross-terms) is used to approximate structural response. The use of the response surface eliminates the need to perform a deterministic analysis in each simulation loop. In addition, use of the response surface requires fewer simulation loops than conventional Monte Carlo simulation. Thereby, the computation time is saved significantly. The statistics (e.g. mean value, standard deviation) of the structural response are calculated through conventional Monte Carlo simulation method. By using Monte Carlo simulation, it is possible to use the existing deterministic finite element code without modifying it. Probabilistic analysis of a truss demonstrates the proposed method' efficiency and accuracy; probabilistic determination of initial cable forces of a cable-stayed bridge under dead loads verifies the method's applicability.

MONTE-CARLO SIMULATION OF THE DUST SCATTERING (먼지 산란의 몬테카를로 시뮬레이션)

  • Seon, Kwang-Il
    • Publications of The Korean Astronomical Society
    • /
    • v.24 no.1
    • /
    • pp.43-51
    • /
    • 2009
  • We present a Monte-Carlo simulation code, which solves the problem of dust-scattering in interstellar dust clouds with arbitrary light source distribution and dust density structure, and calculate the surface brightness distribution. The method is very flexible and can be applied to radiative transfer problems occurring not only in a single dust cloud, but also in extragalactic dust environment. We compare, for performance test, the result of Monte-Carlo simulation with the well-known analytic approximation for a spherically symmetric homogeneous cloud. We find that the Code approximation gives a very accurate result.

6MV Photon Beam Commissioning in Varian 2300C/D with BEAM/EGS4 Monte Carlo Code

  • Kim, Sangroh;Jason W. Sohn;Cho, Byung-Chul;Suh, Tae-Suk;Choe, Bo-Yong;Lee, Hyoung-Koo
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.113-115
    • /
    • 2002
  • The Monte Carlo simulation method is a numerical solution to a problem that models objects interacting with other objects or their environment based upon simple object-object or object-environment relationships. In spite of its great accuracy, It was turned away because of long calculation time to simulate a model. But, it is used to simulate a linear accelerator frequently with the advance of computer technology. To simulate linear accelerator in Monte Carlo simulations, there are many parameters needed to input to Monte Carlo code. These data can be supported by a linear accelerator manufacturer. Although the model of a linear accelerator is the same, a different characteristic property can be found. Thus, we performed a commissioning process of 6MV photon beam in Varian 2300C/D model with BEAM/EGS4 Monte Carlo code. The head geometry data were put into BEAM/EGS4 data. The mean energy and energy spread of the electron beam incident on the target were varied to match Monte Carlo simulations to measurements. TLDs (thermoluminescent dosimeter) and radiochromic films were employed to measure the absorbed dose in a water phantom. Beam profile was obtained in 40cm${\times}$40cm field size and Depth dose was in 10cm${\times}$10cm. At first, we compared the depth dose between measurements and Monte Carlo simulations varying the mean energy of an incident electron beam. Then, we compared the beam profile with adjusting the beam radius of the incident electron beam in Monte Carlo simulation. The results were found that the optimal mean energy was 6MV and beam radius of 0.1mm was well matched to measurements.

  • PDF

Three-dimensional monte carlo modeling and simulation of ion implantation process: an efficient virtual trajectory split approach (3차원 몬테 카를로 이온 주입 공정 모델링 및 시뮬레이션: 효율적인 가상 궤적 발생 알고리듬)

  • 손명식;황호정
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.3
    • /
    • pp.28-38
    • /
    • 1998
  • In our paper is reported a new 3D(dimensional) trajectory split approach with greatly improved efficiency for the Monte Carlo simulation of the 3D profiles of implanted ionand point defect concentrations in single-crystal silicon. This approach has been successfully implemented in our TRICSI Monte Carlo code. Combined with the previously developed model for damage accumalation in our TRICSI code, this model allows phasically based dynamic simulation of 3D profiles over an subsequent process simulation such as diffusion modeling and simulation. A typical time saving of over 10 timeshas been achieved for 3D simulation. Our method ensures much better region aground the implanted area. For 1-D simulation, the optimized condition for trajectory split has set to 3,000 pseudoparticles with 2 split branches.

  • PDF

Monte Carlo Simulation of Thermionic Low Pressure Discharge Plasma (저압 열전자 방전 플라즈마의 Monte Carlo 시뮬레이션)

  • Koh, Wook Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.12
    • /
    • pp.1880-1885
    • /
    • 2012
  • Nonlinear dynamical behaviors in thermionic low pressure discharge are investigated using a particle-in-cell(PIC) simulation. An electrostatic PIC code is developed to model the plasma discharge system including the kinetic effects. The elastic collision, excitation collision, ionization collision, and electron-ion recombination collision are considered in this code. The generated electrons and ions are traced to analyze physical characteristics of the plasma. The simulation results show that the nonlinear oscillation structures are observed for cold plasma in the system and the similar structures are observed for warm plasma with a shift in values of the bifurcation parameter. The detailed oscillation process can be subdivided into three distinct mode; anode-glow, temperature-limited, and double-layer modes.

IMPROVED POD METHODOLOGY USING MONTE CARLO SIMULATION

  • Park, Ik-Keun;Yoon, Jong-Hak;Ro, Sing-Nam;Seo, Seong-Won;Namkoong, Chai-Kwan
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.04a
    • /
    • pp.73-78
    • /
    • 2003
  • Ultrasonic measurement is one of important technologies in the lift-time maintenance of nuclear poler plant. Ultrasonic inspection system is consisted of the operator, equipment and procedure. The reliability of ultrasonic inspection system is affected by its ability. The performance demonstration round robin was conducted to quantify the capability of ultrasonic inspection for in-service. The small number of teams who employed procedures that met or exceeded ASME Sec. XI Code requirements detected the piping of nuclear power plant with various cracks to evaluate the capability of detection and sizing. In this paper, the statistical reliability assessment of ultrasonic nondestructive inspection data using Monte Carlo simulation is presented. The results of the probability of detection (POD) analysis using Monte Carlo simulation are compared to these of logistic probability model. In these results, Monte Carlo simulation was found to be very useful to the reliability assessment f3r the small hit/miss data sets.

  • PDF