• Title/Summary/Keyword: Monte Carlo 계산

Search Result 514, Processing Time 0.022 seconds

Structure and Thermodynamic Properties of Simple Coulomb Liquids Using Perturbation Theory (섭동론에 의한 간단한 쿨롱 액체의 구조 및 열역학적 성질)

  • Shin Dong Young;Lee Jae Weon;Ree T.;Ree Francis H.
    • Journal of the Korean Chemical Society
    • /
    • v.35 no.4
    • /
    • pp.308-315
    • /
    • 1991
  • The structure and thermodynamic properties of body centered cubic structure of simple Coulombic liquids are computed from the perturbation theory for one-component plasma. A comparison of perturbation theory (PT) and Monte Carlo (MC) simulation shows excellent agreement. The hardsphere perturbation theory is applicable to a long-range attractive system, such as the one-component plasma. A comparison of the radial distribution function (g(r)) and the structure factor (S(q)) for PT data and MC data shows agreement. Thus the perturbation theory is an applicable method to explain the structure and thermodynamic properties of Coulomb liquids.

  • PDF

A Study on the Comparison of HPGe Detector Response Data for Low Energy Photons Using MCNP, EGS, and ITS Codes (MCNP, EGS, ITS코드를 이용한 고순도 게르마늄 검출기의 저에너지 광자에 대한 반응 비교연구)

  • Kim, Soon-Young;Kim, Jong-Kyung;Kim, Jong-Oh;Kim, Bong-Hwan
    • Journal of Radiation Protection and Research
    • /
    • v.21 no.2
    • /
    • pp.125-129
    • /
    • 1996
  • The energy response of HPGe detector for low energy Photons was determined by using three Monte Carlo codes. MCNP4A. EGS4, and CYLTRAN in ITS3. In this study. bare HPGe detector$(100 mm^2{\times}10mm)$ was used and a pencil beam was incident perpendicularly on the center of the detector surface. The photopeak efficiency, $K_{\alpha}$ and $K_{\beta}$ escape fractions were calculated as a function of incident X-ray energies ranging from 12 to 60 keV in 2-keV increments. Since the Compton. elastic. ana penetration fraction were negligible in this energy range. they were ignored in the calculation. Although MCNP. EGS, and CYLTRAN codes calculated slightly different energy response of HPGe detector for low energy Photons, it appears that the three Monte Carlo codes can Predict the low energy Photon scattering Processes accurately. The MCNP results, which are generally known as to be less accurate at low energy ranges than the EGS and ITS results. are comparable to the results of EGS and ITS and are applicable to the calculation of the low energy response data of a detector.

  • PDF

Development of Computer Code for Simulation of Multicomponent Aerosol Dynamics -Uncertainty and Sensitivity Analysis- (다성분 에어로졸계의 동특성 묘사를 위한 전산 코드의 개발 -불확실성 및 민감도 해석-)

  • Na, Jang-Hwan;Lee, Byong-Whi
    • Nuclear Engineering and Technology
    • /
    • v.19 no.2
    • /
    • pp.85-98
    • /
    • 1987
  • To analyze the aerosol dynamics in severe accidents of LMFBR, a new computer code entitled MCAD (Multicomponent Aerosol Dynamics) has been developed. The code can treat two component aerosol system using relative collision probability of each particles as sequences of accident scenarios. Coagulation and removal mechanisms incorporating Brownian diffusion and gravitational sedimentation are included in this model. In order to see the effect of particle geometry, the code makes use of the concept of density correction factor and shape factors. The code is verified using the experimental result of NSPP-300 series and compared to other code. At present, it fits the result of experiment well and agrees to the existing code. The input variables included are very uncertain. Hence, it requires uncertainty and sensitivity analysis as a supplement to code development. In this analysis, 14 variables are selected to analyze. The input variables are compounded by experimental design method and Latin hypercube sampling. Their results are applied to Response surface method to see the degree of regression. The stepwise regression method gives an insight to which variables are significant as time elapse and their reasonable ranges. Using Monte Carlo Method to the regression model of LHS, the confidence level of the results of MCAD and their variables is improved.

  • PDF

Dose Distribution Study for Quantitative Evaluation when using Radioisotope (99mTc, 18F) Sources (방사성 동위원소 (99mTc, 18F) 선원 사용 시 인체 내부피폭의 정량적 평가를 위한 선량분포 연구)

  • Ji, Young-Sik;Lee, Dong-Yeon;Yang, Hyun-Gyung
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.5
    • /
    • pp.603-609
    • /
    • 2022
  • The dose distribution in the human body was evaluated and analyzed through dosimetry data using water phantom, ionization chamber and simulated by Monte Carlo simulation for 99mTc and 18F sources, which are frequently used in the nuclear medicine in this study. As a result of this study, it was found that the dose decreased exponentially as the distance from the radioisotope increased, and it particularly showed a tendency to decrease sharply when the radioisotope was separated by 5 cm. It means that a large amount of dose is delivered to an organ located within 4 cm of source's movement path when a source uptake in the human body. Numerically, it was formed in the rage of 0.16 to 2.16 pC/min for 99mTc and 0.49 to 9.29 pC/min for 18F. In addition, the energy transfer coefficient calculated using the result was found to be similar to the measured value and the simulation value in the range of 0.240 to 0.260. Especially, when the measured data and the simulation value were compared, there was a difference is within 2%, so the reliability of the data was secured. In this study, the distribution of radiation generated from a source was calculated to quantitatively evaluate the internal dose by radioisotopes. It presented reliable results through comparative analysis of the measurement value and simulation value. Above all, it has a great significance to the point that it was presented by directly measuring the distribution of radiation in the human body.

Massive Parallel Processing Algorithm for Semiconductor Process Simulation (반도체 공정 시뮬레이션을 위한 초고속 병렬 연산 알고리즘)

  • 이제희;반용찬;원태영
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.3
    • /
    • pp.48-58
    • /
    • 1999
  • In this paper, a new parallel computation method, which fully utilize the parallel processors both in mesh generation and FEM calculation for 2D/3D process simulation, is presented. High performance parallel FEM and parallel linear algebra solving technique was showed that excessive computational requirement of memory size and CPU time for the three-dimensional simulation could be treated successively. Our parallelized numerical solver successfully interpreted the transient enhanced diffusion (TED) phenomena of dopant diffusion and irregular shape of R-LOCOS within 15 minutes. Monte Carlo technique requires excessive computational requirement of CPU time. Therefore high performance parallel solving technique were employed to our cascade sputter simulation. The simulation results of Our sputter simulator allowed the calculation time of 520 sec and speedup of 25 using 30 processors. We found the optimized number of ion injection of our MC sputter simulation is 30,000.

  • PDF

Development of the EGS4 Control Code to Calculate the Dose Distributions in a Strong Magnetic Field (자기장이 인가된 물팬텀 속의 전자선 선량분포 계산을 위한 EGS4 제어코드의 개발과 응용)

  • 정동혁;오영기;신교철;김진기;김기환;김정기;이강규;문성록;김성규
    • Progress in Medical Physics
    • /
    • v.14 no.1
    • /
    • pp.1-7
    • /
    • 2003
  • In this work we developed a EGS4 control code to calculate the dose distributions for high energy electron beams in water phantom applied longitudinal magnetic field. We reviewed the electron's motion in magnetic field and delivered equations for direction changs of the electron by the external magnetic field. The mathematical results are inserted into the EGS4 code system to account for the presence of external magnetic fields in phantom. The electron pencil beam paths of 6 MeV in water phantom are calculated for magnetic fields of 1-3 T and the dose distributions for a field of 1.0 cm in diameter are calculated for magnetic fields of 0.6-1 T using the code. From the results of path calculations we found that the lateral ranges of the electrons are reduced in the magnetic field of 3 T. For a field of 1 cm diameter and a magnetic field of 1 T, the small dose enhancement near the range of the electrons on the depth dose and the penumbra reduction of 0.15 cm on the beam profile are observed. We discussed and evaluated the results from the theoretical concepts.

  • PDF

Assessment of Neutron Skyshine Dose in a Cargo Inspection Facility Using High Energy X-ray (고에너지 X-ray를 이용한 화물검색시설에서의 중성자 Skyshine 방사선량률 평가)

  • Cho, Young-Ho
    • Journal of the Korean Society of Radiology
    • /
    • v.2 no.3
    • /
    • pp.27-31
    • /
    • 2008
  • The radiation protection measures for the photoneutrons are one of the most important issue of radiation safety in high energy X-ray facilities. When the photoneutrons are released from the facility, the general public as well as occupational workers are exposed to unexpected radiations by neutron skyshine effect. In this study, the photoneutron inventory are calculated using monte carlo mothed, and the neutron skyshine dose rate is assessed using the inventory. A 9MeV X-ray cargo inspection facility is considered as a reference facility.

  • PDF

An MPI-CUDA Implementation for Parallel Scalability on Multi-GPU Clusters (멀티-GPU 기반 MPI-CUDA 병렬 성능 확장성)

  • Yi, Hong-Suk;Lee, Seung-Min
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2012.06a
    • /
    • pp.13-15
    • /
    • 2012
  • 매우 빠른 GPU의 성능과 저가의 개발 비용으로, 최신 GPU는 대용량 계산과학 분야에 꼭 필수적인 자원으로 등장하였다. 이 논문에서는 멀티-GPU 클러스터 시스템에서 GPU 컴퓨팅 기술을 적용한 대용량 Monte Carlo 알고리즘을 개발하였다. MPI와 CUDA를 동시에 적용한 결과 8개 GPU까지 병렬 확장성을 얻을 수 있었다. 병렬 성능 확장성 분석 결과, 멀티-GPU 클러스터에서는 GPU 사이의 데이터 통신이 전체 프로그램 성능 향상을 결정하는 매우 중요한 요인임을 보였다.

Soft Error Rate Simulator for DRAM (DRAM 소프트 에러율 시뮬레이터)

  • Shin, Hyung-Soon
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.2
    • /
    • pp.55-61
    • /
    • 1999
  • A soft error rate (SER) simulator for DRAM was developed. In comparison to the other SER simulator using device simulator or Monte Carlo simulator, the proposed simulator substantially reduced the CPU time using an analytical model for the alpha-particle-induced charge collection. By analysing the soft error modes in DRAM, the bit-bar mode was identified as the main cause of soft error. Using the new SER simulator, SER of 256M DRAM was investigated and it was found that the storage capacitance had a 5fF margin.

  • PDF

Small sample tests for two-way contingency tables (2원 분할표의 소표본 검증법)

  • 허명회
    • The Korean Journal of Applied Statistics
    • /
    • v.10 no.2
    • /
    • pp.339-352
    • /
    • 1997
  • Chi-square test based on large sample theory is inappropriate for testing the row homogeneity in two-way contingency table with several sparse cells. For that case, exact testing methods has been developed in the literature and implemented in StatXact(1991). However, considerable computing time is inevitable for moderate size tables. So, Monte Carlo approximation is recommended frequently. In this study, we propose a simple algorithm for generating two-way random tables with fixed row and column margins for small sample chi-square test. Also, we develop “Turkey-type” method for multiple between-row comparisons.

  • PDF