• 제목/요약/키워드: Monotonic load

검색결과 233건 처리시간 0.019초

극저온 상태에서 AC4C-T6 의 가공 경화 모델 결정에 관한 연구 (Cyclic Stress-strain Hardening Model of AC4C-T6 Alloy at Cryogenic Temperature)

  • 이재범;김경수;이장현;유미지;정준모
    • 대한조선학회논문집
    • /
    • 제46권5호
    • /
    • pp.498-509
    • /
    • 2009
  • Present study is concerned with the simulation of plasticity models for the cyclic stressstrain behavior of aluminum alloy AC4C-T6 that can be used for primary materials of LNG cargo pump. Material model of cyclic hardening and plasticity for aluminum alloy AC4C-T6 was investigated through experiments and numerical simulations. Monotonic tensile and cyclic tension-compression test under symmetric load cycles was performed at both room temperature and cryogenic temperature of $-165^{\circ}C$. Based on the experimental data plastic hardening models were evaluated for isotropic/kinematic/combined hardening. FEA (Finite Element Analysis) models which describe the cyclic stress-strain relationship were evaluated for the simulation of plasticity. An appropriate hardening model is proposed comparing the results of FEA with those of experiments.

AE법에 의한 유한 폭 CFRP 판재의 파괴특성 (Fracture Characteristics of Finite-Width CFRP Plates by Acoustic Emission)

  • 박성완;이장규
    • 한국공작기계학회논문집
    • /
    • 제16권3호
    • /
    • pp.125-132
    • /
    • 2007
  • The purpose of present paper is to investigate a fracture characteristics of the finite-width single-edge-notch(SEN) carbon fiber/epoxy reinforced plastics(CFRP) plates by using an acoustic emission(AE). Uni-directionally oriented 10 plies CFRPs specimen which had different notch length were prepared for monotonic tensile test. Matrix cracking appeared over whole testing process and fiber breaking appeared later on mainly Load distribution factor of the matrix confirmed that increased according as increases of plate width ratio. The amplitude distribution of AE signal from a specimens is an aid to the determination of the different fracture mechanism such as matrix cracking, disbonding, interfacial delamination, fiber pull-out, fiber breaking, and etc. In the result of AE amplitude distribution analysis, matrix cracking, fiber disbonding or interfacial delamination, and fiber pull-out or fiber breaking signal correspond to <65dB, <75dB, and <90dB respectively, Also, changes of the slope of cumulative AE energy represented crazing phenomena or degradation of materials.

Ultra-low cycle fatigue tests of Class 1 H-shaped steel beams under cyclic pure bending

  • Zhao, Xianzhong;Tian, Yafeng;Jia, Liang-Jiu;Zhang, Tao
    • Steel and Composite Structures
    • /
    • 제26권4호
    • /
    • pp.439-452
    • /
    • 2018
  • This paper presents experimental and numerical study on buckling behaviors and hysteretic performance of Class 1 H-shaped steel beam subjected to cyclic pure bending within the scope of ultra-low cycle fatigue (ULCF). A loading device was designed to achieve the pure bending loading condition and 4 H-shaped specimens with a small width-to-thickness ratio were tested under 4 different loading histories. The emphasis of this work is on the impacts induced by local buckling and subsequent ductile fracture. The experimental and numerical results indicate that the specimen failure is mainly induced by elasto-plastic local buckling, and is closely correlated with the plastic straining history. Compared with monotonic loading, the elasto-plastic local buckling can occur at a much smaller displacement amplitude due to a number of preceding plastic reversals with relative small strain amplitudes, which is mainly correlated with decreasing tangent modulus of the material under cyclic straining. Ductile fracture is found to be a secondary factor leading to deterioration of the load-carrying capacity. In addition, a new ULCF life evaluation method is proposed for the specimens using the concept of energy decomposition, where the cumulative plastic energy is classified into two categories as isotropic hardening and kinematic hardening correlated. A linear correlation between the two energies is found and formulated, which compares well with the experimental results.

P-Δ 효과를 고려한 기둥항복형 강구조 골조의 안정성 (Stability of Steel Frames with Weak Column-Strong Beam Considering P-Δ effect)

  • 김희동;이명재
    • 한국강구조학회 논문집
    • /
    • 제15권4호통권65호
    • /
    • pp.457-466
    • /
    • 2003
  • 본 연구의 목적은 실험적 방법을 통하여 P-${\Delta}$ 효과를 고려한 기둥항복형 강구조 골조의 안정성을 고찰하는데 있다. 이를 위하여 3개의 1층 1스팬 기둥항복형 강구조 비가새 골조에 대한 가력실험을 실시하였다. 실험의 변수로는 기둥의 강성과 축력비를 적용하였다. 실험결과 기둥의 강성 감소는 P-${\Delta}$효과를 증가시켜 골조의 안정성에 큰 영향을 미치는 것으로 나타났으며, 특히 보항복형 골조와 비교하여 최대내력 도달 이후의 내력자하 현상이 다소 급격하게 나타났다. 이것은 기둥의 강성이 낮은 기둥항복형 골조의 경우 P-${\Delta}$효과의 영향이 골조의 안정성에 미치는 영향이 증가되어 나타난 현상으로 사료된다.

탄소성 파괴역학 모델에 근거한 초고강도 섬유보강 콘크리트 I 형보의 비선형 유한요소해석 (Nonlinear Finite Element Analysis of UHPFRC I-Beam on the Basis of an Elastic-Plastic Fracture Model)

  • 한상묵;궈이홍
    • 한국전산구조공학회논문집
    • /
    • 제22권3호
    • /
    • pp.199-209
    • /
    • 2009
  • 본 논문은 단조하중을 받는 초고강도 섬유보강 콘크리트 I형보의 파괴거동에 대한 3차원 유한요소해석을 수행하였다. 보통 또는 고강도 콘크리트의 구성방정식과 달리 초고강도 섬유보강 콘크리트의 재료적 특성을 나타내기 위해 인장변형률 경화관계를 고려한 탄소성 파괴역학 모델을 제안하였다. 인장영역에서는 인장경화 변형률을 고려한 다차원적 균열기준을 정의하였고, 압축영역에서는 associated flow rule을 고려한 Drucker-Prager기준을 채택하여 해석을 수행하였다. UHPFRCI형보의 지간, 프리스트레스 하중 및 단면의 영향에 관한 수치해석 결과를 실험 거동와 비교한 결과 정확한 해석 결과를 보여주었다.

An experimental study of connections between I-beams and concrete filled steel tubular columns

  • De Nardin, Silvana;El Debs, Ana Lucia H.C.
    • Steel and Composite Structures
    • /
    • 제4권4호
    • /
    • pp.303-315
    • /
    • 2004
  • Frame composed of concrete-filled steel tubular columns and I-shaped steel beam has been researched in order to development reasonable connection details. The present paper describes the results of an experimental program in four different connection details. The connection details considered include through-bolt between I-shaped steel beams and concrete-filled steel tubular columns and two details of welded connections. One of the welded connection details is stiffened by angles welded in the interior of the profile wall at the beam flange level. The specimens were tested in a cruciform loading arrangement with variable monotonic loading on the beams and constant compressive load on the column. For through-bolt details, the contribution of friction and bearing were investigated by embedding some of the bolts in the concrete. The results of the tests show that through-bolt connection details are very ductility and the bearing is not important to the behavior of these moment connections. The angles welded in the interior of the profile wall increase the strength and stiffness of the welded connection detail. In addition, the behavior curves of these connections are compared and some interesting conclusions are drawn. The results are summarized for the strength and stiffness of each connection.

Debonding monitoring of CFRP strengthened RC beams using active sensing and infrared imaging

  • Sohn, Hoon;Kim, Seung Dae;In, Chi Won;Cronin, Kelly E.;Harries, Kent
    • Smart Structures and Systems
    • /
    • 제4권4호
    • /
    • pp.391-406
    • /
    • 2008
  • This study attempts to develop a real-time debonding monitoring system for carbon fiber-reinforced polymer (CFRP) strengthened structures by continuously inspecting the bonding condition between the CFRP layer and the host structure. The uniqueness of this study is in developing a new concept and theoretical framework of nondestructive testing (NDT), in which debonding is detected without relying on previously-obtained baseline data. The proposed reference-free damage diagnosis is achieved based on the concept of time reversal acoustics (TRA). In TRA, an input signal at an excitation point can be reconstructed if the response signal measured at another point is reemitted to the original excitation point after being reversed in the time domain. Examining the deviation of the reconstructed signal from the known initial input signal allows instantaneous identification of damage without requiring a baseline signal representing the undamaged state for comparison. The concept of TRA has been extended to guided wave propagations within the CFRP-strengthened reinforced concrete (RC) beams to improve the detectibility of local debonding. Monotonic and fatigue load tests of large-scale CFRP-strengthened RC beams are conducted to demonstrate the potential of the proposed reference-free debonding monitoring system. Comparisons with an electro-mechanical impedance method and an inferred imaging technique are provided as well.

Strengthening of hollow brick infill walls with expanded steel plates

  • Cumhur, Alper;Altundal, Adil;Aykac, Sabahattin;Aykac, Bengi
    • Earthquakes and Structures
    • /
    • 제11권5호
    • /
    • pp.887-904
    • /
    • 2016
  • An efficient, economical and practical strengthening method for hollow brick infill walls was proposed and investigated in the present study, experimentally and numerically. This method aims at increasing the overall lateral strength and stiffness of the structure by increasing the contribution of the infill walls and providing the non-bearing components of the structure with the capability of absorbing earthquake-induced energy to minimize structural damage during seismic excitations. A total of eleven full-scale infill walls strengthened with expanded mild steel plates were tested under diagonal monotonic loading to simulate the loading condition of the non-bearing walls during an earthquake. The contact surface between the plates and the wall was increased with the help of plaster. Thickness of the plates bonded to both faces of the wall and the spacing of the bolts were adopted as test parameters. The experiments indicated that the plates were able to carry a major portion of the tensile stresses induced by the diagonal loads and provided the walls walls with a considerable confining effect. The composite action attained by the plates and the wall until yielding of the bolts increased the load capacities, rigidities, ductilities and energy-absorption capacities of the walls, considerably.

단조하중을 받는 철골구조물의 접합부 연성도에 관한 연구 (A Study on Connection Ductility of Steel Structures Subjected to Monotonic Loading)

  • 강석봉;김진형
    • 한국강구조학회 논문집
    • /
    • 제12권4호통권47호
    • /
    • pp.375-385
    • /
    • 2000
  • 6층 비가새 및 20층 가새 철골구조물에서 기하 비선형, 재료 비선형, 접합부 비선형을 고려할 때 극한 횡하중에 대해 요구되는 접합부 연성도를 파악하였다. 재료 비선형을 고려하기 위하여 단면 모멘트-곡률 관계는 Fiber 모델을 이용하고 부재 강성행렬은 유연도 선형분포 해석모델을 이용하여 유도하였다. 강접합부를 반강접합부로 대체한 6층 구조물의 접합부 연성도는 강접합부인 경우 보다 적었고 20층 구조물에서 요구되는 반강접합부 연성도는 전단접합부의 경우와 거의 같고 강접합부는 전단접합부나 반강접합부에 비하여 큰 연성도가 필요하였다.

  • PDF

Cyclic behavior of extended end-plate connections with European steel shapes

  • Akgonen, Aliriza I.;Yorgun, Cavidan;Vatansever, Cuneyt
    • Steel and Composite Structures
    • /
    • 제19권5호
    • /
    • pp.1185-1201
    • /
    • 2015
  • The aim of this experimental research is to investigate the conformity of the four-bolt unstiffened moment end-plate connections consisting of European steel sections which do not meet the limitations specified for beam flange width and overall beam depth in ANSI/AISC 358-10 to the requirements of seismic application. However, the connections are satisfactory with the limitations required by Turkish Earthquake Code. For this purpose, four test specimens were designed and cyclic load was applied to three specimens while one was tested under monotonic loading to provide data for the calibration of the analytical models. The moment-rotation hysteresis loops and the failure modes for all test specimens are presented. A full three-dimensional finite element model is also developed for each test specimen for use to predict their behavior and to provide a tool for generating subsequent extensive parametric studies. The test results show that all specimens performed well in terms of rotation capacity and strength. Finite element models are found to be capable of approximating the cyclic behavior of the extended end-plate connection specimens.