• Title/Summary/Keyword: Monochromator

Search Result 85, Processing Time 0.029 seconds

A Simple Laboratory Monochromator Controller (실험실용 간이 분광기 구동장치)

  • Sung, Hakje;Kim, Taesam
    • Analytical Science and Technology
    • /
    • v.6 no.3
    • /
    • pp.345-348
    • /
    • 1993
  • A monchromator controller has been built to drive directly by a personal computer. This controller gives better conveniency and accuracy on spectroscopic experiment when a monochromator has deficient driver. This controller consists with simple electronic circuit and control program. The original spectroscopic precision is retained by using stepper motor. The rate changing method is adopted for short slew time. And the scanning is synchronized with spectrum recording device. Because the controller includes electronic counting ciruit, other program can be executed on personal computer during monochromator scanning.

  • PDF

Optical design of soft X-ray region monochromator (Soft X-ray 영역 단색화 장치의 광학적 설계에 관한 연구)

  • 성면창;최원국;황정남;정광호;김영식
    • Korean Journal of Optics and Photonics
    • /
    • v.3 no.2
    • /
    • pp.86-91
    • /
    • 1992
  • We describe the design of a soft X-ray grating monochromator for synchrotron radiation in the photon energy range 300~1200eV. We investigate the optimum condition in optical parameters of CEM (cylindrical element monochromator), whose performance is well known by Dragon beam line installed recently at Brookhaven National Laboratory by C. T. Chen, fitting the parameter of PLS (Pohang Light Source) storage ring construction.

  • PDF

A study on precision drive mechanism for monochromator grating (단색 분광기 회절격자의 정밀 구동 기구에 관한 연구)

  • Kim, D.S.;Park, K.B.;Kwak, Y.K.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.11
    • /
    • pp.42-49
    • /
    • 1997
  • The extent of absorption and transmitance of the light that passes through some material is changed as the wavelength of the light varies, and which makdes it possible to estimate characteristics of the material. Spectrometer is a measurement system that can analyze the characteristics of material by using this principle. Its application field is so wide that it can be applied to all the arease that are concerned with analyzing materials : biological, environmental, medical and chemical area etc. This study is focused on developing precision sine drive mechanism for grating monochromator which is the most important part of the spectrometers. It is designed to be simple in struicture. It is achieved to derive basic principles to manipu- late precision sine drive mechanism : it should be aligned with a condition that .beta. , the angle between grat- ing normal and grating rod should be the same as .gamma. , the one between moving nut's normal and sliding guide. And also, it's found that the mis-alignments of the grating and mirrors are not the main factor in guaranteeing the linearity of sine drive mechanism. Performance evaluation is achieved by a standard sample by comparing experimental results with standard values. It results in wavelength accuracy of .+-. 0.5nm and resolution of 1nm. Conclusively, it can be verified that the sine drive mechanism developed in this study is not only simple in structure, but also stable and excellent in performanes.

  • PDF

Design Spectrophotometer for Blocking the $2^{nd}$ diffracted Light (2차 회절광 차단을 위한 분광 광도계 설계)

  • 홍영주;곽윤근;김수현
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.875-880
    • /
    • 2004
  • Stray light is the light except the light of the analytic wavelength and the source of measurement error of absorbance. Some experimental results showed that diffractive grating is the major factor of stray light in spectrophotometer. Through the ray tracing with the software tool, classified the paths of the diffractive light from grating and found the range of wavelength which reach the exit slit. The quantity of the stray light(0.025%) is more than the minimum limit of stray light(0.01%) of the single monochromator. A novel optical layout design method, which prevent the reflected rays entering the diffractive grating is proposed.

  • PDF

Optic Characteristics Comparison and Analysis of SMD Type Y/G/W HB LED (SMD형 Y/G/W HB LED의 광특성 비교분식)

  • 황명근;허창수;서유진
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.4
    • /
    • pp.15-21
    • /
    • 2004
  • The optical characteristics; luminous flux, correlated color temperature, and CIE -chromaticity coordinate etc., of HB LED(high brightness light emitting diode) of yellow/green/white SMD(surface mounted device) type were tested with integrating sphere photometer and monochromator, and the results were comparatively evaluated And, for the white LED, color rendering indices were considered to analyze.

Fabrication of reflectometer for vacuum ultraviolet spectral characteristic measurements of optical component (광학부품의 진공자외선특성 측정용 분광반사율계 제작)

  • 신동주;김현종;이인원
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.4
    • /
    • pp.325-330
    • /
    • 2004
  • We fabricated a vacuum ultraviolet spectre-reflectometer which consists of a deuterium light source, a vacuum monochromator, and a sample chamber and detector module. The operation was performed in the ultraviolet spectral ranges between 115 nm and 330 nm at the vacuum pressure of 3.0 ${\times}$ 10$^{-4}$ Pa. The wavelength of the vacuum monochromator was calibrated with the line spectrum of a low pressure Mercury lamp of 253.652 nm and 184.95 nm wavelengths, and its resolution was 0.012 nm, and the precision of wavelength was $\pm$ 0.03 nm. With this reflectometer and a deuterium lamp, we measured the spectral regular transmittance and reflectance of materials(MgF$_2$, CaF$_2$, BaF$_2$, SiO$_2$, Sapphire) used as optical components over the spectral range between 115 nm and 230 nm.

Apparatus and method for analysing spectral response of a CCD optical sensor using an infrared imaging technique (적외선 영상기법에 의한 CCD 센서의 스펙트럼 응답 특성 분석 기법)

  • Kang Seong-Jun;Na Cheol-Hun;Park Soon-Young
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.43 no.3 s.309
    • /
    • pp.25-30
    • /
    • 2006
  • An infrared imaging method is proposed in which direct measurement of the spectral response of CCD sensors can be achieved through digital image processing. This method allows for a simple and economic method to detect the spectral sensitivity of commercialized CCD sensors. The key components of the apparatus are a monochromator, CCD-sample supporter and a personal computer equipped with a digital image processing systems. Tentative experimentation conducted on the commercialized CCD camera has resulted in a fairly consistent agreement with the theoretical model.

Modeling of neutron diffractometry facility of Tehran Research Reactor using Vitess 3.3a and MCNPX codes

  • Gholamzadeh, Z.;Bavarnegin, E.;Rachti, M.Lamehi;Mirvakili, S.M.;Dastjerdi, M.H.Choopan;Ghods, H.;Jozvaziri, A.;Hosseini, M.
    • Nuclear Engineering and Technology
    • /
    • v.50 no.1
    • /
    • pp.151-158
    • /
    • 2018
  • The neutron powder diffractometer (NPD) is used to study a variety of technologically important and scientifically driven materials such as superconductors, multiferroics, catalysts, alloys, ceramics, cements, colossal magnetoresistance perovskites, magnets, thermoelectrics, zeolites, pharmaceuticals, etc. Monte Carlo-based codes are powerful tools to evaluate the neutronic behavior of the NPD. In the present study, MCNPX 2.6.0 and Vitess 3.3a codes were applied to simulate NPD facilities, which could be equipped with different optic devices such as pyrolytic graphite or neutron chopper. So, the Monte Carlo-based codes were used to simulate the NPD facility of the 5 MW Tehran Research Reactor. The simulation results were compared to the experimental data. The theoretical results showed good conformity to experimental data, which indicates acceptable performance of the Vitess 3.3a code in the neutron optic section of calculations. Another extracted result of this work shows that application of neutron chopper instead of monochromator could be efficient to keep neutron flux intensity higher than $10^6n/s/cm^2$ at sample position.

Automatic Alignment of a Collimating Mirror by Using Phase Image Correlatio (위상 이미지 상관기법을 이용한 시준거울의 자동정렬)

  • Kim, Hyun-Suk;Tserendolgor, D.;Kim, Dae-Suk;Lee, Hyung-Chul;Kim, Soo-Hyun
    • Korean Journal of Optics and Photonics
    • /
    • v.22 no.1
    • /
    • pp.30-34
    • /
    • 2011
  • A novel alignment method that can be used for aligning the collimating mirror employed in a monochromator is described. In most of the spectrometer industry, the alignment of optical components such as a focusing mirror, a grating and a collimating mirror has been performed manually so far. In this paper, we use a matchedfilter based image correlation technique for measuring the accurate image position which is used for aligning the collimating mirror. The experimental results show that with the proposed scheme automatic alignment can be completed within 10 seconds.

Studies on the Photo-electrochemical Properties of Ti$O_{2-x}$ Thin Films (Ti$O_{2-x}$ 박막의 광-전기화학적 성질에 관한 연구)

  • Q Won Choi;Chu Hyun Choe;Ki Hyung Chjo;Yong Kook Choi
    • Journal of the Korean Chemical Society
    • /
    • v.29 no.6
    • /
    • pp.582-591
    • /
    • 1985
  • The thin films of Ti$O_{2-x}$, were prepared by vapor oxidation and Ti$O_2$ single crystal was reduced by heating in argon atmosphere. The photo-electrochemical properties of these samples were studied. When the photocurrent was scanned in 1M NaOH electrolyte solution, several peaks were observed in the vicinity of 320nm in the UV-region and in the vicinity of 520nm, 620nm, and 740nm in the visible-region. Contrary to the previous suppositions, those peaks were produced by the second-order lines from the grating monochromator.

  • PDF