• Title/Summary/Keyword: Monitoring unit efficiency

Search Result 59, Processing Time 0.029 seconds

FPGA-based Centralized Controller for Multiple PV Generators Tied to the DC Bus

  • Ahmed, Ashraf;Ganeshkumar, Pradeep;Park, Joung-Hu;Lee, Hojin
    • Journal of Power Electronics
    • /
    • v.14 no.4
    • /
    • pp.733-741
    • /
    • 2014
  • The integration of photovoltaic (PV) energy sources into DC grid has gained considerable attention because of its enhanced conversion efficiency with reduced number of power conversion stages. During the integration process, a local control unit is normally included with every power conversion stage of the PV source to accomplish the process of maximum power point tracking. A centralized monitoring and supervisory control unit is required for monitoring, power management, and protection of the entire system. Therefore, we propose a field-programmable gate array (FPGA) based centralized control unit that integrates all local controllers with the centralized monitoring unit. The main focus of this study is on the process of integrating many local control units into a single central unit. In this paper, we present design and optimization procedures for the hardware implementation of FPGA architecture. Furthermore, we propose a transient analysis and control design methodology with consideration of the nonlinear characteristics of the PV source. Hardware experiment results verify the efficiency of the central control unit and controller design.

IEC61850 Process Bus Based Distributed Power Quality Monitoring (IEC61850 프로세서 버스 기반 분산형 전력품질감시)

  • Park, Jong-Chan;Kim, Byung-Jin
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.56 no.1
    • /
    • pp.13-18
    • /
    • 2007
  • In this paper, authors deal with an application of power quality monitoring using the Sampled Value which is described in the IEC61850 International Standard for substation communication. Firstly, while Merging Unit is designed as a process level device transmitting sensor data, the practical problems such as time delay compensation and optical fiber communication are issued. Secondly, the Sampled Value message which is proper to a power quality monitoring system is presented. Because the power quality monitoring system requests non time critical service comparing to protection and control applications, the Sampled Value service message structure is introduced to improve efficiency. At last, the power quality monitoring server having various power quality analysis functions is suggested to verify the performance of Merging Unit. With the diverse experiments, it is proved that the process bus distributed solution is flexible and economic for the power quality monitoring.

The Study of Distributed Disturbance Recording System (분산형 사고파형저장 시스템에 대한 연구)

  • Park, Jong-Chan;Lee, Se-In
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.1
    • /
    • pp.30-35
    • /
    • 2008
  • In this paper, the application of power Quality monitoring based on Sampled Value(SV) which is introduced in the IEC61850 International Standard for substation communication are discussed. Firstly, while Merging Unit(MU) is designed as a process level device transmitting sensor data, the practical problems such as time delay compensation and optical fiber communication are encountered. Secondly, the Sampled Value message which is proper to a power quality monitoring system is presented. Because the power quality monitoring system requests less time-critical service compared to protection and control applications, the Sampled Value service message structure is introduced to improve efficiency. Lastly, the power quality monitoring server having various power quality analysis functions is suggested to verify the performance of Merging Unit With the diverse experiments, it is proved that the process bus distributed solution is flexible and economic for the power quality monitoring.

Implementation of Performance Monitoring System for Thermal Power Plant in SIEMENS DCS (SIEMENS DCS 환경에서 화력발전소 성능감시 시스템 구현)

  • 김승민;문태선;조창호
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.37-37
    • /
    • 2000
  • This paper introduces the Performance Monitoring System(PMS) in a thermal power plant. The purpose of the PMS is to offer the operator current performance information of plant which could be an index of plant status or information to improve plant efficiency. The PMS of Bukcheju thermal power plant unit #2&3 is implemented under the SIEMENS DCS which supplies about 150 function blocks for performance calculation and all measured signals. The performance of unit, boiler, turbines, feedwater heaters, condenser, airpreheaters, feedwater pumps will be monitored and updated for every 5 minutes in PMS of Bukcheju TPP.

  • PDF

A Design and Implementation of Industrial Fluid Monitoring System (산업공정상의 유체 유동 모니터링 시스템 설계 및 구현)

  • Lee, Won-Joo;Lee, Sang-Jun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.15 no.4
    • /
    • pp.99-106
    • /
    • 2010
  • In this paper, we propose an industrial fluid monitoring system which performs the flow control function and monitors fluid pressure transmitted from MFC(Mass Flow Controller) unit. This system consists of MFC unit, channel device, and monitoring management software. MFC unit transmits the measured data of the fluid pressure to the channel device which would provide the input/output interface between management software, monitoring and MFC unit. The monitoring and management software control and analyze by monitoring real time measurements of fluid pressure from each channel of MFC unit. This software can process 20 channels and 0.1 monitoring cycle which gives 200 data measurement per second (i.e., 720,000 data/hour). At this time, the storage space increases in proportion to the rise of input data. This growth of data and storage space makes loss of data access efficiency. Therefore, it demands the implementation by sensing scheme of change scope and data, which can effectively manage the data.

Development and Evaluation of Multi-string Power Balancing System for Solar Streetlight (태양광 가로등용 멀티스트링 파워 밸런싱 시스템의 개발 및 평가)

  • Yun, Jung-Hyun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.12
    • /
    • pp.1021-1027
    • /
    • 2012
  • In this paper, multi-string power balancing system for streetlight was developed. Accordingly, the components of the system was developed, unit converters, MPPT control unit, a bank of Li-ion battery and controls the charging and discharging. Loss by improving the efficiency of the system through the parallel operation of the unit converter output will be reduced. And by improving the efficiency of the system through the unit converter parallel operation, output losses will be reduced. Charging and discharging efficiency of the device used in a typical solar streetlight is calculated based on the maximum power input. Because of the variation of the input power has a weakness. In this paper, flexible to changes in the input, and a system was developed to minimize the cost per watt. Measure the performance of the unit module from the system, the result was more than 91%. And the charging capacity 12 V/105 Ah, module power 180 W, respectively. Should expect to be able to improve performance through continuous monitoring in the future.

Optimal selection of fish assemblage survey method through comparing the result (어류군집 조사 결과 비교를 통한 최적의 방법 선택)

  • Jae-Young KIM;Sang-Min EOM;Byeong-Mo GIM;Tae Seob CHOI
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.60 no.2
    • /
    • pp.128-141
    • /
    • 2024
  • Fish resource surveys were conducted near Jeju Island in June, August and October 2021 using an underwater camera monitoring system, fish pots, and SCUBA diving methods. The efficiency of the methods used to survey fish resources was compared using the number of individuals compared to area per unit time (inds/m3/h) and the number of species compared to area per unit time (spp./m3/h). As a result of comparing the number of individuals compared to the area per unit time (inds/m3/h), the order was underwater camera 214.69, SCUBA diving 124.62, and fish pots 0.57 inds/m3/h. The number of species compared to area per unit time (spp./m3/h) is in the following order: SCUBA diving 0.85, underwater camera 0.38, and fish pots 0.01 spp./m3/h. The fish resource monitoring method using underwater cameras was found to be more efficient in individual counts, and the SCUBA diving method was found to be more efficient in species counts. When considering cost and survey efficiency, the fish resource survey method using underwater cameras was judged to be more effective. The results of this study are expected to be widely used in estimating the population density of fish, which is the core of future fisheries resource surveys.

An Analysis on the Deployment Methods for Smart Monitoring Systems (스마트 모니터링 시스템의 배치 방식 분석)

  • Heo, No-Jeong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.10 no.6
    • /
    • pp.55-62
    • /
    • 2010
  • Monitoring systems are able to report certain events at region of interest(ROI) and to take an appropriate action. From industrial product line full of robots to fire detection, intrusion detection, smart grid application, environmental pollution alarm system, monitoring system has widely used in diverse industry sector. Recently, due to advance of wireless communication technology and availability of low cost sensors, intelligent and/or smart monitoring systems such as sensor networks has been developed. Several deployment methods are introduced to meet various monitoring needs and deployment performance criteria are also summarized to be used to identify weak point and be useful at designing monitoring systems. Both efficiency during deployment and usefulness after the deployment should be assessed. Efficiency factors during deployment are elapsed time, energy required, deployment cost, safety, sensor node failure rate, scalability. Usefulness factors after deployment are ROI coverage, connectivity, uniformity, target density similarity, energy consumption rate per unit time and so on.

Assessing the Unit Load Reduction Equation of Drainage Outlet Raising Management in Paddy Fields (논 물꼬관리 기법 적용에 따른 원단위 삭감부하량 산정식 평가)

  • Kim, Dong-Hyeon;Oh, Heung-Keun;Jang, Taeil;Ham, Jong-Hwa
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.65 no.2
    • /
    • pp.35-45
    • /
    • 2023
  • The DOR (Drainage outlet raising) in the paddy field has been suggested as one of the most important best management practices for the TMDL (Total maximum daily load) management in the technical guidelines by the NIER (National institute of environmental research). However, this method is underestimated and is not well adopted by local governments for the TMDL. The purpose of this study is to evaluate the unit load reduction equation according to the application of DOR in order to expand this equation. The original equation in the guideline was derived using the HSPF (Hydrological Simulation Program-Fortran) model for 1 year in Changnyeong. We analyzed the reduction effect of the original equation application by collecting additional long-term monitoring data from the Buan, Icheon, Iksan, and Jeonju. When comparing the reduction loads between the original equation and monitoring results, the evaluation results of the original equation were 11% of the monitoring analysis results, which was underestimated. This means that the original equation needs to be improved. For assessing the equation, the HSPF Paddy-RCH model was established according to the NI ER guideline and evaluated for applicability. The performance results of the model showed a reasonable range by the statistical criteria. Modified equations 1 and 2 were proposed based on the monitoring and modeling results. Modified equation 1 was the method of modifying the original equation's main factors, and modified equation 2 was the method of applying the non-point pollution reduction efficiency according to the rainfall class using the long-term modeling results. At the level of 58.6~64.6% of monitoring data, the difference between them could be further reduced compared to the original equation. The suggested approach will be more reasonable and practicable for decision-makers and will contribute to the TMDL management plans.

Performance monitoring results of large-scale PV system (중대규모 계통연계형 PV시스템의 성능결과)

  • So, Jung-Hun;Yu, Gwon-Jong;Jung, Young-Seok;Yu, Byung-Gyu;Hwan, Hye-Mi;Choi, Ju-Yeop
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.1165-1166
    • /
    • 2006
  • This paper presents performance monitoring results of large scale photovoltaic (PV) system supported by general dissemination & regional energy program in korea government polices for new and renewable energy resources. 80kW PV system and monitoring system is constructed and monitored PV system performance to observe the overall effect of environmental conditions on their operation characteristics. The PV system performance has been evaluated and analyzed for component perspective (PV array and power conditioning unit) and global perspective (system efficiency, capacity factor, and electrical power energy and power quality etc.) for six month monitoring periods.

  • PDF